A heap-based buffer overflow vulnerability exists in the GGUF library gguf_fread_str functionality of llama.cpp Commit 18c2e17. A specially crafted .gguf file can lead to code execution. An attacker can provide a malicious file to trigger this vulnerability.
A heap-based buffer overflow vulnerability exists in the GGUF library header.n_kv functionality of llama.cpp Commit 18c2e17. A specially crafted .gguf file can lead to code execution. An attacker can provide a malicious file to trigger this vulnerability.
A heap-based buffer overflow vulnerability exists in the GGUF library info->ne functionality of llama.cpp Commit 18c2e17. A specially crafted .gguf file can lead to code execution. An attacker can provide a malicious file to trigger this vulnerability.
A heap-based buffer overflow vulnerability exists in the GGUF library header.n_tensors functionality of llama.cpp Commit 18c2e17. A specially crafted .gguf file can lead to code execution. An attacker can provide a malicious file to trigger this vulnerability.
A heap-based buffer overflow vulnerability exists in the GGUF library GGUF_TYPE_ARRAY/GGUF_TYPE_STRING parsing functionality of llama.cpp Commit 18c2e17. A specially crafted .gguf file can lead to code execution. An attacker can provide a malicious file to trigger this vulnerability.
llama.cpp provides LLM inference in C/C++. The unsafe `data` pointer member in the `rpc_tensor` structure can cause arbitrary address reading. This vulnerability is fixed in b3561.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter.
Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.1 allows a remote, unauthenticated attacker to execute arbitrary code via a crafted IOCTL 70603 RPC message.
Potential buffer overflow vulnerability in the Zephyr CAN bus subsystem
Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the time parameter in the sysTimeInfoSet function.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
TOTOLINK CP300+ V5.2cu.7594_B20200910 was discovered to contain a stack overflow via the pingIp parameter in the function setDiagnosisCfg.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function.
Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the rebootTime parameter in the sysScheduleRebootSet function.
TOTOLINK X5000R V9.1.0u.6118_B20201102 and TOTOLINK A7000R V9.1.0u.6115_B20201022 was discovered to contain a stack overflow via the File parameter in the function UploadCustomModule.
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the bandwidth parameter in the wifiRadioSetIndoor function.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so's PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint.
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to cause a denial of service (network-communications outage) via a crafted packet.
Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.
Call to the scrypt_enc() function in HHVM can lead to heap corruption by using specifically crafted parameters (N, r and p). This happens if the parameters are configurable by an attacker for instance by providing the output of scrypt_enc() in a context where Hack/PHP code would attempt to verify it by re-running scrypt_enc() with the same parameters. This could result in information disclosure, memory being overwriten or crashes of the HHVM process. This issue affects versions 4.3.0, 4.4.0, 4.5.0, 4.6.0, 4.7.0, 4.8.0, versions 3.30.5 and below, and all versions in the 4.0, 4.1, and 4.2 series.
TOTOLINK CP300+ <=V5.2cu.7594_B20200910 was discovered to contain a stack overflow via the File parameter in the function UploadCustomModule.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter.
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (setDoublePppoeConfig->guest_ip_check(overflow arg: mask) modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeUrlFilter.
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
An unauthenticated attacker can trigger a stack based buffer overflow in the DP Service (TCP port 3500). This vulnerability has been resolved in firmware version 2.800.0000000.8.R.20241111.
Two heap-based buffer overflow vulnerabilities exist in the httpd manage_post functionality of Yifan YF325 v1.0_20221108. A specially crafted network request can lead to a heap buffer overflow. An attacker can send a network request to trigger these vulnerabilities.This integer overflow result is used as argument for the malloc function.
Two heap-based buffer overflow vulnerabilities exist in the httpd manage_post functionality of Yifan YF325 v1.0_20221108. A specially crafted network request can lead to a heap buffer overflow. An attacker can send a network request to trigger these vulnerabilities.This integer overflow result is used as argument for the realloc function.
Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function fromSetLocalVlanInfo.
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to cause a denial of service (process outage) via a crafted packet.
A buffer overflow vulnerability in WhatsApp VOIP stack allowed remote code execution via specially crafted series of RTCP packets sent to a target phone number. The issue affects WhatsApp for Android prior to v2.19.134, WhatsApp Business for Android prior to v2.19.44, WhatsApp for iOS prior to v2.19.51, WhatsApp Business for iOS prior to v2.19.51, WhatsApp for Windows Phone prior to v2.18.348, and WhatsApp for Tizen prior to v2.18.15.
In MicroHttpServer (aka Micro HTTP Server) through 4398570, _ReadStaticFiles in lib/middleware.c allows a stack-based buffer overflow and potentially remote code execution via a long URI.
libcurl versions from 7.36.0 to before 7.64.0 are vulnerable to a stack-based buffer overflow. The function creating an outgoing NTLM type-3 header (`lib/vauth/ntlm.c:Curl_auth_create_ntlm_type3_message()`), generates the request HTTP header contents based on previously received data. The check that exists to prevent the local buffer from getting overflowed is implemented wrongly (using unsigned math) and as such it does not prevent the overflow from happening. This output data can grow larger than the local buffer if very large 'nt response' data is extracted from a previous NTLMv2 header provided by the malicious or broken HTTP server. Such a 'large value' needs to be around 1000 bytes or more. The actual payload data copied to the target buffer comes from the NTLMv2 type-2 response header.
Advantech WebAccess before 8.4.3 allows unauthenticated remote attackers to execute arbitrary code or cause a denial of service (memory corruption) due to a stack-based buffer overflow when handling IOCTL 70533 RPC messages.
Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formSetAutoPing.
Two heap-based buffer overflow vulnerabilities exist in the gwcfg_cgi_set_manage_post_data functionality of Yifan YF325 v1.0_20221108. A specially crafted network request can lead to a heap buffer overflow. An attacker can send a network request to trigger these vulnerabilities.This integer overflow result is used as argument for the realloc function.
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function localMsg.
Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'list' parameter at /goform/SetVirtualServerCfg.
Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the function set_device_name.
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formRebootMeshNode.
Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'list' parameter at /goform/SetStaticRouteCfg.
Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'deviceList' parameter at /goform/setMacFilterCfg.