Cloud Mobility for Dell EMC Storage, 1.3.0.XXX contains a RCE vulnerability. A non-privileged user could potentially exploit this vulnerability, leading to achieving a root shell. This is a critical issue; so Dell recommends customers to upgrade at the earliest opportunity.
Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur.
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a Hard-coded Password Vulnerability. An attacker, with the knowledge of the hard-coded credentials, could potentially exploit this vulnerability to login to the system to gain admin privileges.
PowerPath Management Appliance with versions 3.3 & 3.2* contains a Hardcoded Cryptographic Keys vulnerability. Authenticated admin users can exploit the issue that leads to view and modifying sensitive information stored in the application.
Dell Enterprise SONiC OS, 4.0.0, 4.0.1, contain a cryptographic key vulnerability in SSH. An unauthenticated remote attacker could potentially exploit this vulnerability, leading to unauthorized access to communication.
The Dell Wyse Password Encoder in ThinLinux2 versions prior to 2.1.0.01 contain a Hard-coded Cryptographic Key vulnerability. An unauthenticated remote attacker could reverse engineer the cryptographic system used in the Dell Wyse Password Encoder to discover the hard coded private key and decrypt locally stored cipher text.
Dell SupportAssist for Home PCs (version 3.11.4 and prior) and SupportAssist for Business PCs (version 3.2.0 and prior) contain cryptographic weakness vulnerability. An authenticated non-admin user could potentially exploit the issue and obtain sensitive information.
A hard-coded password vulnerability was discovered in vApp Manager which is embedded in Dell EMC Unisphere for VMAX, Dell EMC Solutions Enabler, Dell EMC VASA Virtual Appliances, and Dell EMC VMAX Embedded Management (eManagement): Dell EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.18, Dell EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.21, Dell EMC VASA Virtual Appliance versions prior to 8.4.0.514, and Dell EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier). They contain an undocumented default account (smc) with a hard-coded password that may be used with certain web servlets. A remote attacker with the knowledge of the hard-coded password and the message format may use vulnerable servlets to gain unauthorized access to the system. Note: This account cannot be used to log in via the web user interface.
Dell EMC SupportAssist Enterprise version 1.1 creates a local Windows user account named "OMEAdapterUser" with a default password as part of the installation process. This unnecessary user account also remains even after an upgrade from v1.1 to v1.2. Access to the management console can be achieved by someone with knowledge of the default password. If SupportAssist Enterprise is installed on a server running OpenManage Essentials (OME), the OmeAdapterUser user account is added as a member of the OmeAdministrators group for the OME. An unauthorized person with knowledge of the default password and access to the OME web console could potentially use this account to gain access to the affected installation of OME with OmeAdministrators privileges. This is fixed in version 1.2.1.
Dell EMC PowerScale OneFS 8.1.x - 9.1.x contain hard coded credentials. This allows a local user with knowledge of the credentials to login as the admin user to the backend ethernet switch of a PowerScale cluster. The attacker can exploit this vulnerability to take the switch offline.
Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) for SCCM and SCVMM versions prior to 7.2.1 contain a hard-coded cryptographic key vulnerability. A remote unauthenticated attacker may exploit this vulnerability to gain access to the appliance data for remotely managed devices.
Dell ELab-Navigator, version 3.1.9 contains a hard-coded credential vulnerability. A local attacker could potentially exploit this vulnerability, leading to unauthorized access to sensitive data. Successful exploitation may result in the compromise of confidential user information.
The SMI-S service in Dell Storage Manager versions earlier than 16.3.20 (aka 2016 R3.20) is protected using a hard-coded password. A remote user with the knowledge of the password might potentially disable the SMI-S service via HTTP requests, affecting storage management and monitoring functionality via the SMI-S interface. This issue, aka DSM-30415, only affects a Windows installation of the Data Collector (not applicable to the virtual appliance).
Integrated Data Protection Appliance versions 2.0, 2.1, and 2.2 contain undocumented accounts named 'support' and 'admin' that are protected with default passwords. These accounts have limited privileges and can access certain system files only. A malicious user with the knowledge of the default passwords may potentially log in to the system and gain read and write access to certain system files.
Dell PowerStore, version(s) 4.0.0.0, contain(s) an Use of Hard-coded Credentials vulnerability in the PowerStore image file. A low privileged attacker with remote access, with the knowledge of the hard-coded credentials, could potentially exploit this vulnerability to gain unauthorized access based on the hardcoded account's privileges.
Dell EMC Networking OS10 versions prior to 10.4.3 contain a cryptographic key vulnerability due to an underlying application using undocumented, pre-installed X.509v3 key/certificate pairs. An unauthenticated remote attacker with the knowledge of the default keys may potentially be able to intercept communications or operate the system with elevated privileges.
Dell PowerScale InsightIQ, version 5.0, contain a Use of hard coded Credentials vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.
Dell SmartFabric OS10 Software, version(s) 10.5.5.4 through 10.5.5.10 and 10.5.6.x, contain(s) an Use of Hard-coded Password vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Client-side request forgery and Information disclosure.
Dell PowerScale OneFS versions 8.2.x through 9.8.0.x contain a use of hard coded credentials vulnerability. An adjacent network unauthenticated attacker could potentially exploit this vulnerability, leading to information disclosure of network traffic and denial of service.
Mutiny 7.2.0-10788 suffers from Hardcoded root password.
Certain NETGEAR devices are affected by a hardcoded password. This affects D3600 before 1.0.0.76 and D6000 before 1.0.0.76.
BB-ESWGP506-2SFP-T versions 1.01.09 and prior is vulnerable due to the use of hard-coded credentials, which may allow an attacker to gain unauthorized access and permit the execution of arbitrary code on the BB-ESWGP506-2SFP-T (versions 1.01.01 and prior).
Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key.
FreeSWITCH 1.6.10 through 1.10.1 has a default password in event_socket.conf.xml.
In Veritas NetBackup OpsCenter, a hard-coded credential exists that could be used to exploit the underlying VxSS subsystem. This affects 8.x through 8.3.0.2, 9.x through 9.0.0.1, 9.1.x through 9.1.0.1, and 10.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software before version 20240417.001 (from that version vulnerability is fixed).
Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi.
A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability.
Gessler GmbH WEB-MASTER has a restoration account that uses weak hard coded credentials and if exploited could allow an attacker control over the web management of the device.
atbox.htm on D-Link DSL-2770L devices allows remote unauthenticated attackers to discover admin credentials.
Hardcoded manufacturer credentials and an OS command injection vulnerability in the /cgi-bin/mft/ directory on ABUS TVIP TVIP20050 LM.1.6.18, TVIP10051 LM.1.6.18, TVIP11050 MG.1.6.03.05, TVIP20550 LM.1.6.18, TVIP10050 LM.1.6.18, TVIP11550 MG.1.6.03, TVIP21050 MG.1.6.03, and TVIP51550 MG.1.6.03 cameras allow remote attackers to execute code as root.
Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.
A vulnerability in the Cisco Small Business Switches software could allow an unauthenticated, remote attacker to bypass the user authentication mechanism of an affected device. The vulnerability exists because under specific circumstances, the affected software enables a privileged user account without notifying administrators of the system. An attacker could exploit this vulnerability by using this account to log in to an affected device and execute commands with full admin rights. Cisco has not released software updates that address this vulnerability. This advisory will be updated with fixed software information once fixed software becomes available. There is a workaround to address this vulnerability.
Weintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.
A CWE-798 “Use of Hard-coded Credentials” vulnerability in the MariaDB database of the web application allows a remote unauthenticated attacker to access the database service and all included data with the same privileges of the web application. This issue affects: AiLux imx6 bundle below version imx6_1.0.7-2.
Dairy Farm Shop Management System v1.0 was discovered to contain hardcoded credentials in the source code which allows attackers access to the control panel if compromised.
Online Course Registration v1.0 was discovered to contain hardcoded credentials in the source code which allows attackers access to the control panel if compromised.
libnx_apl.so on Nexans FTTO GigaSwitch before 6.02N and 7.x before 7.02 implements a Backdoor Account for SSH logins on port 50200 or 50201.
OMICARD EDM has a hard-coded machine key. An unauthenticated remote attacker can use the machine key to send serialized payload to the server to execute arbitrary code, manipulate system data and disrupt service.
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.
IBM Storage Fusion HCI 2.1.0 through 2.6.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 275671.
Echelon SmartServer 2.2 with i.LON Vision 2.2 stores cleartext credentials in a file, which could allow an attacker to obtain cleartext usernames and passwords of the SmartServer. If the attacker obtains the file, then the credentials could be used to control the web user interface and file transfer protocol (FTP) server.
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
A vulnerability was determined in yeqifu carRental up to 3fabb7eae93d209426638863980301d6f99866b3. Affected by this vulnerability is an unknown functionality of the file /carRental_war/druid/login.html of the component Druid. Executing manipulation can lead to hard-coded credentials. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. This product operates on a rolling release basis, ensuring continuous delivery. Consequently, there are no version details for either affected or updated releases.
The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_service) only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default.
Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
The Motorola ACE1000 RTU through 2022-05-02 uses ECB encryption unsafely. It can communicate with an XRT LAN-to-radio gateway by means of an embedded client. Credentials for accessing this gateway are stored after being encrypted with the Tiny Encryption Algorithm (TEA) in ECB mode using a hardcoded key. Similarly, the ACE1000 RTU can route MDLC traffic over Extended Command and Management Protocol (XCMP) and Network Layer (XNL) networks via the MDLC driver. Authentication to the XNL port is protected by TEA in ECB mode using a hardcoded key.