A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function RP_setBasicAuto of the file /goform/RP_setBasicAuto. The manipulation of the argument staticIp/staticNetmask leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in D-Link DIR‑818L up to 1.05B01. This issue affects the function getenv of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function setDeviceName of the file /goform/setDeviceName. The manipulation of the argument DeviceName leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in TOTOLINK N350R 1.2.3-B20130826. This vulnerability affects unknown code of the file /boafrm/formSysCmd. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected is the function ipv6cmd of the file /goform/setIpv6. The manipulation of the argument Ipv6PriDns/Ipv6SecDns/Ipv6StaticGateway/LanIpv6Addr/LanPrefixLen/pppoeUser/pppoePass/pppoeIdleTime/pppoeRedialPeriod/Ipv6in4_PrefixLen/LocalIpv6/RemoteIpv4/LanIPv6_Prefix/LanPrefixLen/ipv6to4Relay/ipv6rdRelay/tunrd_PrefixLen/wan_UseLinkLocal/Ipv6StaticIp/Ipv6PrefixLen leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in TOTOLINK X15 1.0.0-B20230714.1105. It has been classified as critical. Affected is an unknown function of the file /boafrm/formMapDelDevice of the component HTTP POST Request Handler. The manipulation of the argument macstr leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function sub_3517C of the file /goform/setWan. The manipulation of the argument Hostname leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
DrayTek Vigor3900 1.5.1.3 allows attackers to inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the doCertificate function.
A vulnerability classified as critical has been found in D-Link DIR‑817L up to 1.04B01. This affects the function lxmldbc_system of the file ssdpcgi. The manipulation leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in TOTOLINK T6 4.1.5cu.748_B20211015. It has been declared as critical. This vulnerability affects the function setTracerouteCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument command leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by an command injection vulnerability in the device name input field, which can be triggered by authenticated users via a crafted POST request.
A vulnerability was found in TOTOLINK T6 4.1.5cu.748_B20211015. It has been classified as critical. This affects the function setDiagnosisCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ip leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in Tenda O3V2 1.0.0.12(3880). This issue affects the function fromTraceroutGet of the file /goform/getTraceroute of the component httpd. The manipulation of the argument dest leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Xuxueli xxl-job up to 3.1.1 and classified as critical. Affected by this vulnerability is the function commandJobHandler of the file src\main\java\com\xxl\job\executor\service\jobhandler\SampleXxlJob.java. The manipulation leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in D-Link DIR-816L up to 2.06B01 and classified as critical. Affected by this vulnerability is the function lxmldbc_system of the file /htdocs/cgibin of the component Environment Variable Handler. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
An issue was discovered in Geomatika IsiGeo Web 6.0. It allows remote authenticated users to execute commands.
A vulnerability was found in D-Link DIR-645 up to 1.05B01 and classified as critical. This issue affects the function ssdpcgi_main of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability, which was classified as critical, was found in Netgear D6400 1.0.0.114. This affects an unknown part of the file diag.cgi. The manipulation of the argument host_name leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early and confirmed the existence of the vulnerability. They reacted very quickly, professional and kind. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability classified as critical was found in TOTOLINK T6 4.1.5cu.748. This vulnerability affects the function ckeckKeepAlive of the file wireless.so of the component MQTT Packet Handler. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability in the web UI of Cisco IOS XE Software could allow an authenticated, remote attacker to inject and execute arbitrary commands with administrative privileges on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of user-supplied input to the web UI. An attacker could exploit this vulnerability by submitting crafted input to the web UI. A successful exploit could allow an attacker to execute arbitrary commands with administrative privileges on an affected device.
A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. This affects an unknown part of the component Web Management Interface. The manipulation of the argument ecn-up leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227649 was assigned to this vulnerability.
A vulnerability was found in Belkin F9K1122 1.00.33. It has been classified as critical. This affects the function mp of the file /goform/mp of the component webs. The manipulation of the argument command leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component Web Management Interface. The manipulation of the argument name leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227653 was assigned to this vulnerability.
A vulnerability, which was classified as critical, was found in D-Link DI-7300G+ and DI-8200G 17.12.20A1/19.12.25A1. This affects an unknown part of the file msp_info.htm. The manipulation of the argument flag/cmd/iface leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Command injection in homemng.htm in Juplink RX4-1500 versions V1.0.2, V1.0.3, V1.0.4, and V1.0.5 allows remote authenticated attackers to execute commands via specially crafted requests to the vulnerable endpoint.
A vulnerability classified as critical has been found in D-Link DI-7300G+ 19.12.25A1. Affected is an unknown function of the file wget_test.asp. The manipulation of the argument url leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
An OS command injection vulnerability exists in the daretools binary functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability.
A vulnerability was found in Belkin F9K1122 1.00.33 and classified as critical. Affected by this issue is the function formBSSetSitesurvey of the file /goform/formBSSetSitesurvey of the component webs. The manipulation of the argument wan_ipaddr/wan_netmask/wan_gateway/wl_ssid is directly passed by the attacker/so we can control the wan_ipaddr/wan_netmask/wan_gateway/wl_ssid leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue in Yealink T21P_E2 Phone 52.84.0.15 allows a remote normal privileged attacker to execute arbitrary code via a crafted request the ping function of the diagnostic component.
Cacti is an open source performance and fault management framework. Prior to 1.2.29, there is an input-validation flaw in the SNMP device configuration functionality. An authenticated Cacti user can supply crafted SNMP community strings containing control characters (including newlines) that are accepted, stored verbatim in the database, and later embedded into backend SNMP operations. In environments where downstream SNMP tooling or wrappers interpret newline-separated tokens as command boundaries, this can lead to unintended command execution with the privileges of the Cacti process. This vulnerability is fixed in 1.2.29.
This vulnerability allows authenticated attackers to execute commands via the hostname of the device.
Coolify is an open-source and self-hostable tool for managing servers, applications, and databases. In Coolify versions up to and including v4.0.0-beta.434, a command injection vulnerability exists in the git source input fields of a resource, allowing a low privileged user (member) to execute system commands as root on the Coolify instance. As of time of publication, it is unclear if a patch is available.
NetModule NSRW web administration interface executes an OS command constructed with unsanitized user input. A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges. This issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.
An issue in Intermesh BV GroupOffice vulnerable before v.25.0.47 and 6.8.136 allows a remote attacker to execute arbitrary code via the dbToApi() and eval() in the FunctionField.php
A vulnerability classified as critical was found in Wifi-soft UniBox Controller up to 20250506. Affected by this vulnerability is an unknown functionality of the file /authentication/logout.php. The manipulation of the argument mac_address leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Wifi-soft UniBox Controller up to 20250506. This affects an unknown part of the file /billing/pms_check.php. The manipulation of the argument ipaddress leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in Wifi-soft UniBox Controller up to 20250506. Affected by this issue is some unknown functionality of the file /billing/test_accesscodelogin.php. The manipulation of the argument Password leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
AVTECH SECURITY Corporation DGM1104 FullImg-1015-1004-1006-1003 was discovered to contain an authenticated command injection vulnerability in the NetFailDetectD binary. This vulnerability allows attackers to execute arbitrary commands via a crafted input.
A vulnerability has been found in Tenda CP3 11.10.00.2311090948 and classified as critical. Affected by this vulnerability is the function sub_F3C8C of the file apollo. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
AVTECH SECURITY Corporation DGM1104 FullImg-1015-1004-1006-1003 was discovered to contain an authenticated command injection vulnerability in the Machine.cgi endpoint. This vulnerability allows attackers to execute arbitrary commands via a crafted input.
A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
Improper neutralization of special elements used in a command ('command injection') in SQL Server allows an authorized attacker to elevate privileges over a network.
A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been rated as critical. Affected by this issue is the function verifyFacebookLike of the file /goform/verifyFacebookLike. The manipulation of the argument uid/accessToken leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in D-Link DI-500WF-WT up to 20250511 and classified as critical. Affected by this vulnerability is the function sub_456DE8 of the file /msp_info.htm?flag=cmd of the component /usr/sbin/jhttpd. The manipulation of the argument cmd leads to command injection. The attack can be launched remotely.
A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. Affected by this vulnerability is the function WPS of the file /goform/WPS. The manipulation of the argument PIN leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function NTP of the file /goform/NTP. The manipulation of the argument manual_year_select/manual_month_select/manual_day_select/manual_hour_select/manual_min_select/manual_sec_select leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Dell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 9.2.3.x contain a command execution vulnerability. A low privileged remote attacker could potentially exploit this vulnerability, leading to execute arbitrary commands on the underlying system.
A vulnerability was found in Teledyne FLIR AX8 up to 1.46.16. This vulnerability affects the function setDataTime of the file \usr\www\application\models\settingsregional.php. Performing manipulation of the argument year/month/day/hour/minute results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. Upgrading to version 1.49.16 is able to resolve this issue. Upgrading the affected component is recommended. The vendor points out: "FLIR AX8 internal web site has been refactored to be able to handle the reported vulnerabilities."
OPNsense before 25.1.8 contains an authenticated command injection vulnerability in its Bridge Interface Edit endpoint (interfaces_bridge_edit.php). The span POST parameter is concatenated into a system-level command without proper sanitization or escaping, allowing an administrator to inject arbitrary shell operators and payloads. Successful exploitation results in remote code execution with the privileges of the web service (typically root), potentially leading to full system compromise or lateral movement. This vulnerability arises from inadequate input validation and improper handling of user-supplied data in backend command invocations.