Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-32840

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-16 Apr, 2025 | 17:38
Updated At-17 Apr, 2025 | 14:18
Rejected At-
Credits

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:16 Apr, 2025 | 17:38
Updated At:17 Apr, 2025 | 14:18
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Affected Products
Vendor
Siemens AGSiemens
Product
TeleControl Server Basic
Default Status
unknown
Versions
Affected
  • From 0 before V3.1.2.2 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-89CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Type: CWE
CWE ID: CWE-89
Description: CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/html/ssa-443402.html
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-443402.html
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:16 Apr, 2025 | 18:16
Updated At:19 Aug, 2025 | 15:22

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Siemens AG
siemens
>>telecontrol_server_basic>>Versions before 3.1.2.2(exclusive)
cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-89Primaryproductcert@siemens.com
CWE ID: CWE-89
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/html/ssa-443402.htmlproductcert@siemens.com
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-443402.html
Source: productcert@siemens.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1909Records found

CVE-2025-32827
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ActivateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32856
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32850
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32871
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'MigrateDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-27941
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.29% / 78.86%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-06 Feb, 2025 | 18:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected client systems do not properly sanitize input data before sending it to the SQL server. An attacker could use this vulnerability to compromise the whole database.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOWruggedcom_crossbow
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32832
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32862
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32859
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32843
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-30002
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25909)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-29905
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'RestoreFromBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-37197
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.72% / 71.64%
||
7 Day CHG~0.00%
Published-11 Jan, 2022 | 11:27
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS is vulnerable to SQL injections. This could allow an attacker to execute arbitrary SQL statements.

Action-Not Available
Vendor-Siemens AG
Product-comosCOMOS V10.3COMOS V10.2COMOS V10.4
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32864
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32835
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariableArchivingBuffering' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32870
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetTraces' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32828
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32865
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateLog' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32858
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-31343
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25920)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-27463
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.57% / 67.61%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 18:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.3). The audit log form of affected applications is vulnerable to SQL injection. This could allow authenticated remote attackers to execute arbitrary SQL queries on the server database.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOW
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-27411
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.57% / 67.61%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-27 Feb, 2025 | 21:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an authenticated remote attackers to execute arbitrary SQL queries on the server database and escalate privileges.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOW
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-33729
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.32% / 79.07%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker that is able to import firmware containers to an affected system could execute arbitrary commands in the local database.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-4845
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.80%
||
7 Day CHG~0.00%
Published-26 Jun, 2018 | 18:00
Updated-16 Sep, 2024 | 18:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.

Action-Not Available
Vendor-Siemens AG
Product-rapidlab_1200_firmwarerapidpoint_500_firmwarerapidpoint_500rapidpoint_400_firmwarerapidlab_1200rapidpoint_400RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems, RAPIDLab 1200 Series, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 400 systems
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-269
Improper Privilege Management
CVE-2021-45033
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.24%
||
7 Day CHG~0.00%
Published-11 Jan, 2022 | 11:27
Updated-04 Aug, 2024 | 04:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device.

Action-Not Available
Vendor-Siemens AG
Product-cp-8000_master_module_with_i\/o_-25\/\+70cp-8000_master_module_with_i\/o_-25\/\+70_firmwarecp-8000_master_module_with_i\/o_-40\/\+70_firmwarecp-8022_master_module_with_gprs_firmwarecp-8021_master_modulecp-8022_master_module_with_gprscp-8000_master_module_with_i\/o_-40\/\+70cp-8021_master_module_firmwareCP-8022 MASTER MODULE WITH GPRSCP-8021 MASTER MODULECP-8000 MASTER MODULE WITH I/O -25/+70°CCP-8000 MASTER MODULE WITH I/O -40/+70°C
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2021-45960
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.37% / 58.26%
||
7 Day CHG-0.01%
Published-01 Jan, 2022 | 18:47
Updated-05 May, 2025 | 17:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Expat (aka libexpat) before 2.4.3, a left shift by 29 (or more) places in the storeAtts function in xmlparse.c can lead to realloc misbehavior (e.g., allocating too few bytes, or only freeing memory).

Action-Not Available
Vendor-libexpat_projectn/aSiemens AGTenable, Inc.NetApp, Inc.Debian GNU/Linux
Product-nessusactive_iq_unified_managerdebian_linuxsolidfire_\&_hci_management_nodelibexpatsinema_remote_connect_serveroncommand_workflow_automationhci_baseboard_management_controllern/a
CWE ID-CWE-682
Incorrect Calculation
CVE-2021-40360
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.31% / 53.92%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7SIMATIC WinCC V15 and earlierSIMATIC WinCC V17SIMATIC PCS 7 V9.1SIMATIC PCS 7 V9.0SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC WinCC V16SIMATIC PCS 7 V8.2
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2021-37174
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.56% / 67.16%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices have a privilege escalation vulnerability, if exploited, an attacker could gain root user access.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_rx1511ruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx1512_firmwareRUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-250
Execution with Unnecessary Privileges
CVE-2025-40737
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.11% / 30.78%
||
7 Day CHG+0.01%
Published-08 Jul, 2025 | 10:34
Updated-21 Aug, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application does not properly validate file paths when extracting uploaded ZIP files. This could allow an attacker to write arbitrary files to restricted locations and potentially execute code with elevated privileges (ZDI-CAN-26571).

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-31888
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.72% / 81.63%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)

Action-Not Available
Vendor-Siemens AG
Product-talon_tc_compactdesigo_pxm20-edesigo_pxc22.1-e.dapogee_pxc_compactdesigo_pxc001-e.d_firmwareapogee_modular_equiment_controller_firmwaredesigo_pxc12-e.dapogee_pxc_compact_firmwaredesigo_pxc200-e.d_firmwareapogee_modular_equiment_controllerdesigo_pxc100-e.dapogee_modular_building_controllerdesigo_pxc001-e.dapogee_pxc_modular_firmwaretalon_tc_modular_firmwaretalon_tc_modulardesigo_pxc22.1-e.d_firmwaredesigo_pxc50-e.dapogee_modular_building_controller_firmwaredesigo_pxc12-e.d_firmwaredesigo_pxc22-e.ddesigo_pxc22-e.d_firmwaredesigo_pxc00-u_firmwarenucleus_readystart_v3desigo_pxc00-e.ddesigo_pxc100-e.d_firmwaredesigo_pxc200-e.ddesigo_pxc00-e.d_firmwaredesigo_pxc50-e.d_firmwarenucleus_netdesigo_pxc64-utalon_tc_compact_firmwaredesigo_pxc36.1-e.d_firmwaredesigo_pxc64-u_firmwaredesigo_pxc128-udesigo_pxc00-uapogee_pxc_modulardesigo_pxm20-e_firmwaredesigo_pxc36.1-e.ddesigo_pxc128-u_firmwarenucleus_source_codeTALON TC Compact (BACnet)Desigo PXC64-UDesigo PXC00-UNucleus Source CodeAPOGEE PXC Compact (BACnet)APOGEE MEC (PPC) (P2 Ethernet)Nucleus NETDesigo PXC001-E.DDesigo PXC100-E.DDesigo PXC12-E.DAPOGEE MBC (PPC) (BACnet)Desigo PXC22.1-E.DTALON TC Modular (BACnet)Nucleus ReadyStart V3APOGEE MEC (PPC) (BACnet)Desigo PXC00-E.DAPOGEE MBC (PPC) (P2 Ethernet)Desigo PXC50-E.DAPOGEE PXC Compact (P2 Ethernet)Desigo PXC36.1-E.DAPOGEE PXC Modular (P2 Ethernet)Desigo PXC22-E.DDesigo PXC200-E.DDesigo PXM20-EAPOGEE PXC Modular (BACnet)Desigo PXC128-U
CWE ID-CWE-170
Improper Null Termination
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-27392
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.24% / 47.65%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server.

Action-Not Available
Vendor-Siemens AG
Product-siveillance_video_open_network_bridgeSiveillance Video Open Network Bridge
CWE ID-CWE-321
Use of Hard-coded Cryptographic Key
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2022-43545
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.9||CRITICAL
EPSS-1.14% / 77.48%
||
7 Day CHG~0.00%
Published-08 Nov, 2022 | 00:00
Updated-03 Aug, 2024 | 13:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the RecordType-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.

Action-Not Available
Vendor-Siemens AG
Product-7kg9501-0aa01-2aa1_firmware7kg9501-0aa01-2aa17kg9501-0aa31-2aa17kg9501-0aa31-2aa1_firmwareSICAM P850POWER METER SICAM Q100SICAM P855
CWE ID-CWE-20
Improper Input Validation
CVE-2022-43439
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.9||CRITICAL
EPSS-0.93% / 75.12%
||
7 Day CHG~0.00%
Published-08 Nov, 2022 | 00:00
Updated-03 Aug, 2024 | 13:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the Language-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.

Action-Not Available
Vendor-Siemens AG
Product-7kg9501-0aa01-2aa1_firmware7kg9501-0aa01-2aa17kg9501-0aa31-2aa17kg9501-0aa31-2aa1_firmwareSICAM P850POWER METER SICAM Q100SICAM P855
CWE ID-CWE-20
Improper Input Validation
CVE-2020-25240
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.34% / 55.77%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integrity and gain information from logs and templates of the service.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-863
Incorrect Authorization
CVE-2024-41976
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.6||HIGH
EPSS-0.75% / 72.22%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 07:54
Updated-23 Aug, 2024 | 18:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.1). Affected devices do not properly validate input in specific VPN configuration fields. This could allow an authenticated remote attacker to execute arbitrary code on the device.

Action-Not Available
Vendor-Siemens AG
Product-scalance_mum856-1_\(eu\)ruggedcom_rm1224_lte\(4g\)_nam_firmwarescalance_mum856-1_\(b1\)_firmwarescalance_m874-2_firmwarescalance_m874-3scalance_m876-4_\(eu\)ruggedcom_rm1224_lte\(4g\)_euscalance_mum856-1_\(b1\)scalance_m812-1_\(annex_a\)scalance_m812-1_\(annex_b\)scalance_m876-4_\(nam\)scalance_m804pb_firmwarescalance_s615_lan-routerscalance_m874-3_firmwarescalance_m876-3_firmwarescalance_mum853-1_\(b1\)scalance_mum853-1_\(eu\)scalance_s615_eec_lan-routerscalance_s615_lan-router_firmwareruggedcom_rm1224_lte\(4g\)_namscalance_m876-3_\(rok\)_firmwarescalance_m874-3_3g-router_\(cn\)_firmwarescalance_mum853-1_\(b1\)_firmwarescalance_mum856-1_\(cn\)scalance_mum856-1_\(a1\)_firmwarescalance_mum856-1_\(a1\)scalance_mum856-1_\(row\)scalance_m876-3_\(rok\)scalance_mum856-1_\(eu\)_firmwarescalance_mum856-1_\(cn\)_firmwarescalance_m876-3scalance_m876-4_\(eu\)_firmwarescalance_m816-1_\(annex_b\)scalance_m876-4scalance_m876-4_firmwarescalance_mum853-1_\(a1\)_firmwarescalance_s615_eec_lan-router_firmwarescalance_m812-1_\(annex_a\)_firmwarescalance_m874-2scalance_mum856-1_\(row\)_firmwarescalance_m876-4_\(nam\)_firmwarescalance_m804pbscalance_m874-3_3g-router_\(cn\)scalance_m816-1_\(annex_b\)_firmwarescalance_m812-1_\(annex_b\)_firmwarescalance_m816-1_\(annex_a\)_firmwarescalance_mum853-1_\(eu\)_firmwarescalance_m826-2_shdsl-router_firmwarescalance_mum853-1_\(a1\)ruggedcom_rm1224_lte\(4g\)_eu_firmwarescalance_m816-1_\(annex_a\)scalance_m826-2_shdsl-routerSCALANCE M874-3 3G-Router (CN)SCALANCE M874-3SCALANCE M816-1 ADSL-Router familySCALANCE MUM856-1 (B1)SCALANCE M876-3 (ROK)SCALANCE MUM856-1 (A1)SCALANCE M804PBSCALANCE MUM856-1 (EU)SCALANCE MUM853-1 (B1)SCALANCE MUM853-1 (EU)SCALANCE S615 EEC LAN-RouterSCALANCE M874-2SCALANCE M876-4RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE M876-3SCALANCE M826-2 SHDSL-RouterSCALANCE MUM856-1 (CN)SCALANCE MUM856-1 (RoW)RUGGEDCOM RM1224 LTE(4G) EUSCALANCE M812-1 ADSL-Router familySCALANCE M876-4 (EU)SCALANCE MUM853-1 (A1)SCALANCE M876-4 (NAM)SCALANCE S615 LAN-Routerscalance_m812-1_adsl-routerscalance_mum856-1_\(eu\)scalance_m876-3scalance_m816-1_adsl-routerscalance_m876-4scalance_m874-3scalance_mum856-1_\(b1\)scalance_m876-4_\(eu\)ruggedcom_rm1224_lte\(4g\)_euscalance_m876-4_\(nam\)scalance_s615_lan-routerscalance_m874-2scalance_m804pbscalance_m874-3_3g-router_\(cn\)scalance_mum853-1_\(b1\)scalance_mum853-1_\(eu\)scalance_s615_eec_lan-routerscalance_mum853-1_\(a1\)ruggedcom_rm1224_lte\(4g\)_namscalance_mum856-1_\(cn\)scalance_mum856-1_\(row\)scalance_mum856-1_\(a1\)scalance_m826-2_shdsl-routerscalance_m876-3_\(rok\)
CWE ID-CWE-20
Improper Input Validation
CVE-2023-44374
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.1||HIGH
EPSS-0.19% / 40.75%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 11:04
Updated-14 Jan, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices allow to change the password, but insufficiently check which password is to be changed. With this an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user, which could allow to escalate privileges.

Action-Not Available
Vendor-Siemens AG
Product-6gk5216-0ha00-2as6_firmware6gk5213-3bf00-2ab26gk5216-0ba00-2tb26gk5204-2aa00-2gf26gk5205-3bd00-2ab2_firmware6gk5213-3bd00-2ab2_firmware6gk5206-2rs00-2ac2_firmware6gk5224-4gs00-2fc26gk5328-4fs00-3ar36gk5213-3bd00-2tb26gk5206-2bs00-2fc26gk5205-3bb00-2ab26gk5206-2rs00-2ac26gk5206-2bs00-2fc2_firmware6gk5328-4fs00-2rr36gk5208-0ba00-2tb26gk5208-0ha00-2as6_firmware6gk5208-0ha00-2ts6_firmware6gk5205-3bb00-2ab2_firmware6gk5216-0ba00-2fc2_firmware6gk5224-4gs00-2tc26gk5206-2bb00-2ac26gk5206-2gs00-2tc26gk5326-2qs00-3ar3_firmware6gk5213-3bf00-2tb2_firmware6gk5216-3rs00-5ac2_firmware6gk5216-0ua00-5es66gk5206-2bd00-2ac26gk5216-4gs00-2tc2_firmware6gk5328-4ss00-2ar36gk5216-4bs00-2ac26gk5208-0ha00-2as66gk5213-3bb00-2ab26gk5213-3bb00-2ab2_firmware6gk5208-0ba00-2ac26gk5216-4bs00-2ac2_firmware6gk5208-0ba00-2fc26gk5216-0ba00-2ac2_firmware6gk5328-4fs00-3ar3_firmware6gk5204-0ba00-2gf2_firmware6gk5208-0ra00-5ac26gk5216-0ha00-2es66gk5216-0ha00-2es6_firmware6gk5224-4gs00-2tc2_firmware6gk5216-0ba00-2fc26gk5216-0ua00-5es6_firmware6gk5213-3bd00-2ab26ag1208-0ba00-7ac2_firmware6ag1206-2bs00-7ac26gk5208-0ra00-2ac2_firmware6gk5216-4gs00-2tc26ag1206-2bs00-7ac2_firmware6gk5224-4gs00-2fc2_firmware6gk5324-0ba00-2ar3_firmware6gk5206-2gs00-2ac26gk5208-0ha00-2ts66gk5326-2qs00-3ar36ag1206-2bb00-7ac2_firmware6ag1216-4bs00-7ac26gk5208-0ba00-2ab2_firmware6gk5206-2bd00-2ac2_firmware6gk5204-0ba00-2yf2_firmware6gk5206-2bs00-2ac26gk5328-4ss00-3ar36gk5208-0ga00-2tc2_firmware6gk5208-0ba00-2fc2_firmware6gk5205-3bf00-2tb26gk5206-2rs00-5ac26gk5205-3bd00-2tb26gk5328-4ss00-3ar3_firmware6gk5224-4gs00-2ac2_firmware6gk5324-0ba00-3ar3_firmware6gk5328-4fs00-3rr36gk5216-0ba00-2ab2_firmware6gk5328-4ss00-2ar3_firmware6gk5205-3bb00-2tb2_firmware6gk5216-0ba00-2ab26gk5216-4gs00-2fc26gk5213-3bd00-2tb2_firmware6gk5216-4gs00-2ac26gk5216-3rs00-5ac26gk5216-3rs00-2ac26gk5208-0ga00-2ac2_firmware6gk5205-3bf00-2ab26gk5208-0ga00-2ac26gk5224-4gs00-2ac26gk5206-2gs00-2tc2_firmware6gk5206-2gs00-2ac2_firmware6gk5208-0ga00-2fc2_firmware6gk5206-2rs00-5fc26gk5208-0ba00-2ac2_firmware6gk5326-2qs00-3rr36gk5328-4fs00-2ar3_firmware6gk5326-2qs00-3rr3_firmware6gk5208-0ra00-5ac2_firmware6gk5204-2aa00-2yf2_firmware6gk5204-2aa00-2yf26gk5216-0ha00-2ts66gk5205-3bf00-2ab2_firmware6gk5216-4gs00-2ac2_firmware6gk5206-2rs00-5ac2_firmware6gk5216-3rs00-2ac2_firmware6gk5208-0ba00-2tb2_firmware6gk5216-0ha00-2as66gk5204-0ba00-2yf26gk5208-0ua00-5es6_firmware6gk5204-2aa00-2gf2_firmware6gk5208-0ua00-5es66gk5213-3bb00-2tb26gk5216-0ba00-2tb2_firmware6gk5206-2bs00-2ac2_firmware6gk5208-0ga00-2tc26gk5206-2gs00-2fc2_firmware6gk5204-0ba00-2gf26gk5206-2bb00-2ac2_firmware6ag1206-2bb00-7ac26gk5213-3bb00-2tb2_firmware6gk5208-0ha00-2es66gk5205-3bf00-2tb2_firmware6gk5206-2rs00-5fc2_firmware6gk5216-4gs00-2fc2_firmware6gk5324-0ba00-3ar36gk5205-3bd00-2tb2_firmware6gk5328-4fs00-2ar36gk5216-0ba00-2ac26gk5206-2gs00-2fc26ag1208-0ba00-7ac26gk5328-4fs00-2rr3_firmware6ag1216-4bs00-7ac2_firmware6gk5224-0ba00-2ac2_firmware6gk5208-0ga00-2fc26gk5213-3bf00-2ab2_firmware6gk5208-0ra00-2ac26gk5328-4fs00-3rr3_firmware6gk5208-0ba00-2ab26gk5205-3bd00-2ab26gk5324-0ba00-2ar36gk5216-0ha00-2ts6_firmware6gk5213-3bf00-2tb26gk5224-0ba00-2ac26gk5208-0ha00-2es6_firmware6gk5205-3bb00-2tb2SCALANCE S615 LAN-RouterSCALANCE WAM766-1 (ME)SCALANCE WAM766-1SCALANCE WUM766-1SCALANCE WUB762-1 iFeaturesSCALANCE M812-1 ADSL-RouterSCALANCE WUM766-1 (ME)SCALANCE M816-1 ADSL-RouterSCALANCE M876-4 (EU)SCALANCE WUB762-1RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE M874-2SCALANCE WAM763-1SCALANCE M804PBSCALANCE WAM766-1 EEC (ME)SCALANCE WAM766-1 EECSCALANCE WUM763-1 (US)SCALANCE WAM766-1 EEC (US)SCALANCE WUM763-1SCALANCE WUM766-1 (USA)SCALANCE WAM763-1 (US)SCALANCE MUM853-1 (EU)RUGGEDCOM RM1224 LTE(4G) EUSCALANCE M826-2 SHDSL-RouterSCALANCE MUM856-1 (RoW)SCALANCE M876-4SCALANCE WAB762-1SCALANCE M876-3 (ROK)SCALANCE WAM763-1 (ME)SCALANCE MUM856-1 (EU)SCALANCE WAM766-1 (US)SCALANCE M874-3SCALANCE S615 EEC LAN-RouterSCALANCE M876-4 (NAM)
CWE ID-CWE-567
Unsynchronized Access to Shared Data in a Multithreaded Context
CVE-2023-40731
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.7||MEDIUM
EPSS-0.16% / 37.00%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-27 Feb, 2025 | 20:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application allows users to upload arbitrary file types. This could allow an attacker to upload malicious files, that could potentially lead to code tampering.

Action-Not Available
Vendor-Siemens AG
Product-qms_automotiveQMS Automotive
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-40726
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.14% / 34.76%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-27 Feb, 2025 | 20:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application server responds with sensitive information about the server. This could allow an attacker to directly access the database.

Action-Not Available
Vendor-Siemens AG
Product-qms_automotiveQMS Automotive
CWE ID-CWE-550
Server-generated Error Message Containing Sensitive Information
CVE-2024-41939
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.22% / 44.64%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 07:54
Updated-13 Aug, 2024 | 14:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and elevate their privileges on the application.

Action-Not Available
Vendor-Siemens AG
Product-SINEC NMSsinec_nms
CWE ID-CWE-863
Incorrect Authorization
CVE-2024-39865
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-8.05% / 91.76%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-27 Aug, 2025 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows users to upload encrypted backup files. As part of this backup, files can be restored without correctly checking the path of the restored file. This could allow an attacker with access to the backup encryption key to upload malicious files, that could potentially lead to remote code execution.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2024-39570
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-1.92% / 82.61%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-27 Aug, 2025 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. This could allow an authenticated attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-39866
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.21% / 43.07%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-27 Aug, 2025 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with administrative privileges.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-267
Privilege Defined With Unsafe Actions
CVE-2024-39571
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-1.15% / 77.58%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-27 Aug, 2025 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading SNMP configurations. This could allow an attacker with the right to modify the SNMP configuration to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-18288
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-7.74% / 91.56%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with valid authentication at the RMI interface could be able to gain remote code execution through an unsecured file upload. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-10918
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.38% / 58.62%
||
7 Day CHG~0.00%
Published-14 May, 2019 | 19:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7simatic_wincc_runtime_professionalsimatic_wincc_\(tia_portal\)SIMATIC WinCC Runtime Professional V13SIMATIC WinCC (TIA Portal) V14SIMATIC WinCC (TIA Portal) V13SIMATIC WinCC Runtime Professional V14SIMATIC PCS 7 V8.2SIMATIC WinCC V7.3SIMATIC PCS 7 V9.0SIMATIC WinCC (TIA Portal) V15SIMATIC PCS 7 V8.1SIMATIC WinCC Runtime Professional V15SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC PCS 7 V8.0 and earlierSIMATIC WinCC V7.2 and earlier
CWE ID-CWE-749
Exposed Dangerous Method or Function
CVE-2023-28829
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-3.9||LOW
EPSS-0.07% / 22.56%
||
7 Day CHG~0.00%
Published-13 Jun, 2023 | 08:17
Updated-03 Jan, 2025 | 01:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.

Action-Not Available
Vendor-Siemens AG
Product-simatic_net_pc_softwaresinaut_st7scsimatic_pcs_7simatic_winccSIMATIC NET PC Software V14SIMATIC NET PC Software V15SIMATIC WinCCSIMATIC PCS 7 V9.0SINAUT Software ST7scSIMATIC PCS 7 V9.1SIMATIC PCS 7 V8.2
CWE ID-CWE-477
Use of Obsolete Function
CVE-2023-27310
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.6||MEDIUM
EPSS-0.25% / 48.30%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:31
Updated-27 Feb, 2025 | 19:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). The client query handler of the affected application fails to check for proper permissions when assigning groups to user accounts. This could allow an authenticated remote attacker to assign administrative groups to otherwise non-privileged user accounts.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOW
CWE ID-CWE-862
Missing Authorization
CVE-2025-40738
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.11% / 30.78%
||
7 Day CHG+0.01%
Published-08 Jul, 2025 | 10:34
Updated-21 Aug, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application does not properly validate file paths when extracting uploaded ZIP files. This could allow an attacker to write arbitrary files to restricted locations and potentially execute code with elevated privileges (ZDI-CAN-26572).

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-25910
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-10||CRITICAL
EPSS-0.44% / 62.43%
||
7 Day CHG~0.00%
Published-13 Jun, 2023 | 08:17
Updated-02 Aug, 2024 | 11:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server.

Action-Not Available
Vendor-Siemens AG
Product-simatic_step_7simatic_pcs_7simatic_s7-pmSIMATIC PCS 7SIMATIC S7-PMSIMATIC STEP 7 V5
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2020-25239
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.34% / 55.77%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-863
Incorrect Authorization
CVE-2017-6458
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-5.22% / 89.56%
||
7 Day CHG~0.00%
Published-27 Mar, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in the ctl_put* functions in NTP before 4.2.8p10 and 4.3.x before 4.3.94 allow remote authenticated users to have unspecified impact via a long variable.

Action-Not Available
Vendor-ntpn/aApple Inc.Siemens AGHewlett Packard Enterprise (HPE)
Product-mac_os_xhpux-ntpntpsimatic_net_cp_443-1_opc_uasimatic_net_cp_443-1_opc_ua_firmwaren/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 38
  • 39
  • Next
Details not found