A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ActivateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'MigrateDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected client systems do not properly sanitize input data before sending it to the SQL server. An attacker could use this vulnerability to compromise the whole database.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25909)
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'RestoreFromBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS is vulnerable to SQL injections. This could allow an attacker to execute arbitrary SQL statements.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariableArchivingBuffering' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetTraces' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateLog' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25920)
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.3). The audit log form of affected applications is vulnerable to SQL injection. This could allow authenticated remote attackers to execute arbitrary SQL queries on the server database.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an authenticated remote attackers to execute arbitrary SQL queries on the server database and escalate privileges.
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker that is able to import firmware containers to an affected system could execute arbitrary commands in the local database.
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device.
In Expat (aka libexpat) before 2.4.3, a left shift by 29 (or more) places in the storeAtts function in xmlparse.c can lead to realloc misbehavior (e.g., allocating too few bytes, or only freeing memory).
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices have a privilege escalation vulnerability, if exploited, an attacker could gain root user access.
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application does not properly validate file paths when extracting uploaded ZIP files. This could allow an attacker to write arbitrary files to restricted locations and potentially execute code with elevated privileges (ZDI-CAN-26571).
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)
A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server.
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the RecordType-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the Language-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integrity and gain information from logs and templates of the service.
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.1). Affected devices do not properly validate input in specific VPN configuration fields. This could allow an authenticated remote attacker to execute arbitrary code on the device.
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices allow to change the password, but insufficiently check which password is to be changed. With this an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user, which could allow to escalate privileges.
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application allows users to upload arbitrary file types. This could allow an attacker to upload malicious files, that could potentially lead to code tampering.
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application server responds with sensitive information about the server. This could allow an attacker to directly access the database.
A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and elevate their privileges on the application.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows users to upload encrypted backup files. As part of this backup, files can be restored without correctly checking the path of the restored file. This could allow an attacker with access to the backup encryption key to upload malicious files, that could potentially lead to remote code execution.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. This could allow an authenticated attacker to execute arbitrary code with root privileges.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with administrative privileges.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading SNMP configurations. This could allow an attacker with the right to modify the SNMP configuration to execute arbitrary code with root privileges.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with valid authentication at the RMI interface could be able to gain remote code execution through an unsecured file upload. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). The client query handler of the affected application fails to check for proper permissions when assigning groups to user accounts. This could allow an authenticated remote attacker to assign administrative groups to otherwise non-privileged user accounts.
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application does not properly validate file paths when extracting uploaded ZIP files. This could allow an attacker to write arbitrary files to restricted locations and potentially execute code with elevated privileges (ZDI-CAN-26572).
A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights.
Multiple buffer overflows in the ctl_put* functions in NTP before 4.2.8p10 and 4.3.x before 4.3.94 allow remote authenticated users to have unspecified impact via a long variable.