Canon IJ Network Tool/Ver.4.7.5 and earlier (supported OS: OS X 10.9.5-macOS 13),IJ Network Tool/Ver.4.7.3 and earlier (supported OS: OS X 10.7.5-OS X 10.8) allows an attacker to acquire sensitive information on the Wi-Fi connection setup of the printer from the software.
An issue was discovered on goTenna v1 devices with app 5.5.3 and firmware 0.25.5. By default, the GID is the user's phone number unless they specifically opt out. A phone number is very sensitive information because it can be tied back to individuals. The app does not encrypt the GID in messages.
Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.
BEC Technologies Multiple Routers Insufficiently Protected Credentials Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of BEC Technologies routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within /cgi-bin/tools_usermanage.asp. The issue results from transmitting a list of users and their credentials to be handled on the client side. An attacker can leverage this vulnerability to disclose transported credentials, leading to further compromise. Was ZDI-CAN-25895.
A cleartext transmission of sensitive information vulnerability has been reported to affect QNAP operating systems. If exploited, the vulnerability possibly allows local network clients to read the contents of unexpected sensitive data via unspecified vectors. We have already fixed the vulnerability in the following versions: QTS 5.0.1.2425 build 20230609 and later QTS 5.1.0.2444 build 20230629 and later QuTS hero h5.1.0.2424 build 20230609 and later
A vulnerability in the Autonomic Networking feature of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, adjacent attacker to reset the Autonomic Control Plane (ACP) of an affected system and view ACP packets that are transferred in clear text within an affected system, an Information Disclosure Vulnerability. More Information: CSCvd51214. Known Affected Releases: Denali-16.2.1 Denali-16.3.1.
rhn-proxy: may transmit credentials over clear-text when accessing RHN Satellite
This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP. Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
The goTenna Pro App does not encrypt callsigns in messages. It is recommended to not use sensitive information in callsigns when using this and previous versions of the app and update your app to the current app version which uses AES-256 encryption for callsigns in encrypted operation.
A protocol flaw vulnerability exists in the Xiaomi Mi Connect Service APP. The vulnerability is caused by the validation logic is flawed and can be exploited by attackers to leak sensitive user information.
NVIDIA DGX H100 BMC contains a vulnerability in IPMI, where an attacker may cause insufficient protection of credentials. A successful exploit of this vulnerability may lead to information disclosure.
An issue was discovered on goTenna Mesh devices with app 5.5.3 and firmware 1.1.12. By default, a GID is the user's phone number unless they specifically opt out. A phone number is very sensitive information because it can be tied back to individuals. The app does not encrypt the GID in messages.
The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, there is a Trend Controls Inter-Controller (IC) protocol cleartext transmission of credentials issue. The affected components are characterized as: Inter-Controller (IC) protocol (57612/UDP). The potential impact is: Compromise of credentials. Several Trend Controls building automation controllers utilize the Inter-Controller (IC) protocol in for information exchange and automation purposes. This protocol offers authentication in the form of a 4-digit PIN in order to protect access to sensitive operations like strategy uploads and downloads as well as optional 0-30 character username and password protection for web page access protection. Both the PIN and usernames and passwords are transmitted in cleartext, allowing an attacker with passive interception capabilities to obtain these credentials. Credentials are transmitted in cleartext. An attacker who obtains Trend IC credentials can carry out sensitive engineering actions such as manipulating controller strategy or configuration settings. If the credentials in question are (re)used for other applications, their compromise could potentially facilitate lateral movement.
IBM QRadar SIEM 7.3 and 7.4 uses less secure methods for protecting data in transit between hosts when encrypt host connections is not enabled as well as data at rest. IBM X-Force ID: 192539.
u'Specifically timed and handcrafted traffic can cause internal errors in a WLAN device that lead to improper layer 2 Wi-Fi encryption with a consequent possibility of information disclosure over the air for a discrete set of traffic' in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Voice & Music, Snapdragon Wearables, Snapdragon Wired Infrastructure and Networking in APQ8053, IPQ4019, IPQ8064, MSM8909W, MSM8996AU, QCA9531, QCN5502, QCS405, SDX20, SM6150, SM7150
Improper usage of insecure protocol (i.e. HTTP) in SogouSDK of Chinese Samsung Keyboard prior to versions 5.3.70.1 in Android 11, 5.4.60.49, 5.4.85.5, 5.5.00.58 in Android 12, and 5.6.00.52, 5.6.10.42, 5.7.00.45 in Android 13 allows adjacent attackers to access keystroke data using Man-in-the-Middle attack.
In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, an information disclosure vulnerability in the communication protocol of the insulin pump and its AnyDana-i and AnyDana-A mobile applications allows unauthenticated attackers to extract the pump’s keypad lock PIN via Bluetooth Low Energy.
There is no check to see if slot 0 is being uploaded from the device to the host. When using encrypted images this means the unencrypted firmware can be retrieved easily.
Jenkins Active Directory Plugin 2.25 and earlier does not encrypt the transmission of data between the Jenkins controller and Active Directory servers in most configurations.
Incorrect access control in TP-Link Tapo before v3.1.315 allows attackers to access user credentials in plaintext.
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.
The Infinite Design application 3.4.12 for Android sends a username and password via TCP without any encryption during login, as demonstrated by sniffing of a public Wi-Fi network.
SITEL CAP/PRX firmware version 5.2.01 allows an attacker with access to the local network of the device to obtain the authentication passwords by analysing the network traffic.
IBM QRadar SIEM 7.5 transmits sensitive or security-critical data in cleartext in a communication channel that could be obtained by an unauthorized actor using man in the middle techniques.
UPNP Service listening on port 5555 in Genexis Platinum 4410 Router V2.1 (P4410-V2–1.34H) has an action 'X_GetAccess' which leaks the credentials of 'admin', provided that the attacker is network adjacent.
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.
Nordic Semiconductor Android BLE Library through 2.2.1 and DFU Library through 1.10.4 for Android (as used by nRF Connect and other applications) can engage in unencrypted communication while showing the user that the communication is purportedly encrypted. The problem is in bond creation (e.g., internalCreateBond in BleManagerHandler).