Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.
IBM Data Risk Manager 2.0.1, 2.0.2, 2.0.3, 2.0.4, 2.0.5, and 2.0.6 could allow a remote attacker to bypass security restrictions when configured with SAML authentication. By sending a specially crafted HTTP request, an attacker could exploit this vulnerability to bypass the authentication process and gain full administrative access to the system. IBM X-Force ID: 180532.
[Calendar01], [Calendar02], [PKOBO-News01], [PKOBO-vote01], [Telop01], [Gallery01], [CalendarForm01], and [Link01] [Calendar01] free edition ver1.0.0, [Calendar02] free edition ver1.0.0, [PKOBO-News01] free edition ver1.0.3 and earlier, [PKOBO-vote01] free edition ver1.0.1 and earlier, [Telop01] free edition ver1.0.0, [Gallery01] free edition ver1.0.3 and earlier, [CalendarForm01] free edition ver1.0.3 and earlier, and [Link01] free edition ver1.0.0 allows remote attackers to bypass authentication and log in to the product with administrative privileges via unspecified vectors.
Open Access Management (OpenAM) is an access management solution that includes Authentication, SSO, Authorization, Federation, Entitlements and Web Services Security. OpenAM up to version 14.7.2 does not properly validate the signature of SAML responses received as part of the SAMLv1.x Single Sign-On process. Attackers can use this fact to impersonate any OpenAM user, including the administrator, by sending a specially crafted SAML response to the SAMLPOSTProfileServlet servlet. This problem has been patched in OpenAM 14.7.3-SNAPSHOT and later. User unable to upgrade should comment servlet `SAMLPOSTProfileServlet` from their pom file. See the linked GHSA for details.
A security flaw has been discovered in Apeman ID71 218.53.203.117. This vulnerability affects unknown code of the file /system/www/system.ini. The manipulation results in hard-coded credentials. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
IBM InfoSphere Data Replication 11.4 and IBM InfoSphere Change Data Capture for z/OS 10.2.1, under certain configurations, could allow a user to bypass authentication mechanisms using an empty password string. IBM X-Force ID: 189834
Authentication vulnerability found in Etcd-io v.3.4.10 allows remote attackers to escalate privileges via the debug function.
SpotCam Co., Ltd. SpotCam FHD 2 has a vulnerability of using hard-coded uBoot credentials. An remote attacker can exploit this vulnerability to access the system to perform arbitrary system operations or disrupt service.
On the D-Link DIR-615 before v20.12PTb04, once authenticated, this device identifies the user based on the IP address of his machine. By spoofing the IP address belonging to the victim's host, an attacker might be able to take over the administrative session without being prompted for authentication credentials. An attacker can get the victim's and router's IP addresses by simply sniffing the network traffic. Moreover, if the victim has web access enabled on his router and is accessing the web interface from a different network that is behind the NAT/Proxy, an attacker can sniff the network traffic to know the public IP address of the victim's router and take over his session as he won't be prompted for credentials.
SpotCam Co., Ltd. SpotCam FHD 2’s hidden Telnet function has a vulnerability of using hard-coded Telnet credentials. An remote unauthenticated attacker can exploit this vulnerability to access the system to perform arbitrary system operations or disrupt service.
A use of hard-coded cryptographic key in Fortinet FortiSwitch version 7.4.0 and 7.2.0 through 7.2.5 and 7.0.0 through 7.0.7 and 6.4.0 through 6.4.13 and 6.2.0 through 6.2.7 and 6.0.0 through 6.0.7 allows attacker to execute unauthorized code or commands via crafted requests.
NETGEAR ProSAFE Network Management System MyHandlerInterceptor Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of NETGEAR ProSAFE Network Management System. Authentication is not required to exploit this vulnerability. The specific flaw exists within the MyHandlerInterceptor class. The issue results from improper implementation of the authentication mechanism. An attacker can leverage this vulnerability to bypass authentication on the system. . Was ZDI-CAN-19718.
i-doit pro 25 and below and I-doit open 25 and below are configured with insecure default administrator credentials, and there is no warning or prompt to ask users to change the default password and account name. Unauthenticated attackers can exploit this vulnerability to obtain Administrator privileges, resulting in them being able to perform arbitrary system operations or cause a Denial of Service (DoS).
Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by hard coded credentials. A hardcoded credential exist in /etc/tomcat8/tomcat-user.xml, which allows attackers to gain authorized access and control the tomcat completely on port 8000 in the tomcat manger page.
Logsign Unified SecOps Platform Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Logsign Unified SecOps Platform. Authentication is not required to exploit this vulnerability. The specific flaw exists within the web service, which listens on TCP port 443 by default. The issue results from the lack of proper implementation of the authentication algorithm. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-25336.
In maccms v10, an attacker can log in through /index.php/user/login in the "col" and "openid" parameters to gain privileges.
IBM Security Verify Access 10.7 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 181395.
IBM Verify Gateway (IVG) 1.0.0 and 1.0.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 179266.
Hardcoded admin token in SoundBar apps in Linkplay SDK 1.00 allows remote attackers to gain admin privilege access in linkplay antifactory
The initial admin account setup wizard on Lexmark devices allow unauthenticated access to the “out of service erase” feature.
Dell EMC Networking S4100 and S5200 Series Switches manufactured prior to February 2020 contain a hardcoded credential vulnerability. A remote unauthenticated malicious user could exploit this vulnerability and gain administrative privileges.
Multiple NEC products (Express5800/T110j, Express5800/T110j-S, Express5800/T110j (2nd-Gen), Express5800/T110j-S (2nd-Gen), iStorage NS100Ti, and Express5800/GT110j) where Baseboard Management Controller (BMC) firmware Rev1.09 and earlier is applied allows remote attackers to bypass authentication and then obtain/modify BMC setting information, obtain monitoring information, or reboot/shut down the vulnerable product via unspecified vectors.
CAMS for HIS CENTUM CS 3000 (includes CENTUM CS 3000 Small) R3.08.10 to R3.09.50, CENTUM VP (includes CENTUM VP Small, Basic) R4.01.00 to R6.07.00, B/M9000CS R5.04.01 to R5.05.01, and B/M9000 VP R6.01.01 to R8.03.01 allows a remote unauthenticated attacker to bypass authentication and send altered communication packets via unspecified vectors.
Rakuten Casa version AP_F_V1_4_1 or AP_F_V2_0_0 uses a hard-coded credential which may allow a remote unauthenticated attacker to log in with the root privilege and perform an arbitrary operation.
Zoho ManageEngine PAM360 before build 5303 allows attackers to modify a few aspects of application state because of a filter bypass in which authentication is not required.
AVTECH AVN801 DVR has a security bypass via the administration login captcha
IBM Cognos Controller 10.4.0, 10.4.1, and 10.4.2 could allow a remote attacker to bypass security restrictions, caused by improper validation of authentication cookies. IBM X-Force ID: 190847.
JBL soundbar multibeam 5.1 - CWE-798: Use of Hard-coded Credentials
Rundeck is an open source automation service with a web console, command line tools and a WebAPI. Rundeck community and rundeck-enterprise docker images contained a pre-generated SSH keypair. If the id_rsa.pub public key of the keypair was copied to authorized_keys files on remote host, those hosts would allow access to anyone with the exposed private credentials. This misconfiguration only impacts Rundeck Docker instances of PagerDuty® Process Automation On Prem (formerly Rundeck) version 4.0 and earlier, not Debian, RPM or .WAR. Additionally, the id_rsa.pub file would have to be copied from the Docker image filesystem contents without overwriting it and used to configure SSH access on a host. A patch on Rundeck's `main` branch has removed the pre-generated SSH key pair, but it does not remove exposed keys that have been configured. To patch, users must run a script on hosts in their environment to search for exposed keys and rotate them. Two workarounds are available: Do not use any pre-existing public key file from the rundeck docker images to allow SSH access by adding it to authorized_keys files and, if you have copied the public key file included in the docker image, remove it from any authorized_keys files.
IBM Security Guardium 11.3 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 186697.
An improper authentication vulnerability has been reported to affect QNAP device running Photo Station. If exploited, this vulnerability allows attackers to compromise the security of the system. We have already fixed this vulnerability in the following versions of Photo Station: Photo Station 6.0.20 ( 2022/02/15 ) and later Photo Station 5.7.16 ( 2022/02/11 ) and later Photo Station 5.4.13 ( 2022/02/11 ) and later
An Authentication Bypass vulnerability exists in Gitea before 1.5.0, which could let a malicious user gain privileges. If captured, the TOTP code for the 2FA can be submitted correctly more than once.
IBM Data Risk Manager 2.0.1, 2.0.2, 2.0.3, 2.0.4, 2.0.5, and 2.0.6 contains a default password for an IDRM administrative account. A remote attacker could exploit this vulnerability to login and execute arbitrary code on the system with root privileges. IBM X-Force ID: 180534.
An authentication bypass vulnerability exists in the web interface /action/factory* functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted HTTP header can lead to authentication bypass. An attacker can send an HTTP request to trigger this vulnerability.
IBM Connect:Direct for UNIX 6.1.0, 6.0.0, 4.3.0, and 4.2.0 can allow a local or remote user to obtain an authenticated CLI session due to improper authentication methods. IBM X-Force ID: 188516.
IBM Spectrum Protect Plus 10.1.0 thorugh 10.1.6 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 190454.
In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentials to gain SuperUser access to the device.
Zoho ManageEngine Access Manager Plus before 4203 allows anyone to view a few data elements (e.g., access control details) and modify a few aspects of the application state.
EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system.
IBM Spectrum Protect Plus 10.1.0 through 10.1.5 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 175066.
Zoho ManageEngine ServiceDesk Plus MSP before 10.5 Build 10534 is vulnerable to unauthenticated remote code execution due to a filter bypass in which authentication is not required.
DVR firmware in TAT-76 and TAT-77 series of products, provided by TONNET, contain misconfigured authentication mechanism. Attackers can crack the default password and gain access to the system.
CasaOS is an open-source Personal Cloud system. Unauthenticated attackers can craft arbitrary JWTs and access features that usually require authentication and execute arbitrary commands as `root` on CasaOS instances. This problem was addressed by improving the validation of JWTs in commit `705bf1f`. This patch is part of CasaOS 0.4.4. Users should upgrade to CasaOS 0.4.4. If they can't, they should temporarily restrict access to CasaOS to untrusted users, for instance by not exposing it publicly.
A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions < V1.6.284.0). Affected applications insufficiently limit the access to the internal user authentication service. This could allow an unauthenticated remote attacker to trigger several actions on behalf of valid user accounts.
A vulnerability was found in SourceCodester Company Website CMS 1.0. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /dashboard/settings. The manipulation leads to improper authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-206161 was assigned to this vulnerability.
An issue was discovered in phpABook 0.9 Intermediate. On the login page, if one sets a userInfo cookie with the value of admin+1+en (user+perms+lang), one can login as any user without a password.
IBM Spectrum Protect Plus 10.1.0 through 10.1.5 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174975.
The login REST API in ProLion CryptoSpike 3.0.15P2 (when LDAP or Active Directory is used as the users store) allows a remote blocked user to login and obtain an authentication token by specifying a username with different uppercase/lowercase character combination.
An improper authentication vulnerability has been reported to affect QNAP device running Video Station. If exploited, this vulnerability allows attackers to compromise the security of the system. We have already fixed this vulnerability in the following versions of Video Station: Video Station 5.5.9 and later Video Station 5.3.13 and later Video Station 5.1.8 and later
IBM SiteProtector Appliance 3.1.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174142.