The Blackmagic ATEM Mini Pro 2.7 exposes sensitive device and stream configuration information via an unauthenticated Telnet service on port 9990. Upon connection, the attacker can access a protocol preamble that leaks the video mode, routing configuration, input/output labels, device model, and even internal identifiers such as the unique ID. This can be used for reconnaissance and planning further attacks.
The Blackmagic Web Presenter HD firmware version 3.3 exposes sensitive information via an unauthenticated Telnet service on port 9977. When connected, the service reveals extensive device configuration data including: - Model, version, and unique identifiers - Network settings including IP, MAC, DNS - Current stream platform, stream key, and streaming URL - Audio/video configuration This data can be used to hijack live streams or perform network reconnaissance.
When parsing a file that is submitted to the DPDecoder service as a job, the R3D SDK will mistakenly skip over the assignment of a property containing an object referring to a UUID that was parsed from a frame within the video container. Upon destruction of the object that owns it, the uninitialized member will be dereferenced and then destroyed using the object’s virtual destructor. Due to the object property being uninitialized, this can result in dereferencing an arbitrary pointer for the object’s virtual method table, which can result in code execution under the context of the application.
When parsing a file that is submitted to the DPDecoder service as a job, the service will use the combination of decoding parameters that were submitted with the job along with fields that were parsed for the submitted video by the R3D SDK to calculate the size of a heap buffer. Due to an integer overflow with regards to this calculation, this can result in an undersized heap buffer being allocated. When this heap buffer is written to, a heap-based buffer overflow will occur. This can result in code execution under the context of the application.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/menu/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to edit user group permissions via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/menu/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to edit user permissions via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/guest-mode/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to enable passwordless guest mode via crafted HTTP requests.
An attacker could modify or disable settings, disrupt fuel monitoring and supply chain operations, leading to disabling of ATG monitoring. This would result in potential safety hazards in fuel storage and transportation.
Affected versions of Smartstore have a missing WebApi Authentication attribute. This vulnerability affects Smartstore shops in version 4.0.0 & 4.0.1 which have installed and activated the Web API plugin. Users of Smartstore 4.0.0 and 4.0.1 must merge their repository with 4.0.x or overwrite the file SmartStore.Web.Framework in the */bin* directory of the deployed shop with this file. As a workaround without updating uninstall the Web API plugin to close this vulnerability.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
ONTAP Select Deploy administration utility versions 2.12 & 2.12.1 ship with an HTTP service bound to the network allowing unauthenticated remote attackers to perform administrative actions.
ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
Certain functionality within GMOD Apollo does not require authentication when passed with an administrative username
xlockmore 5.13 allows potential xlock bypass when FVWM switches to the same virtual desktop as a new Gaim window.
xlockmore 5.13 and 5.22 segfaults when using libpam-opensc and returns the underlying xsession. This allows unauthorized users access to the X session.
The querier component in Grafana Enterprise Logs 1.1.x through 1.3.x before 1.4.0 does not require authentication when X-Scope-OrgID is used. Versions 1.2.1, 1.3.1, and 1.4.0 contain the bugfix. This affects -auth.type=enterprise in microservices mode
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
Lack of access control in Nakivo Backup & Replication Transporter version 9.4.0.r43656 allows remote users to access unencrypted backup repositories and the Nakivo Controller configuration via a network accessible transporter service. It is also possible to create or delete backup repositories.
A missing authentication for critical function in Fortinet FortiProxy versions 7.6.0 through 7.6.1, FortiSwitchManager version 7.2.5, and FortiOS versions 7.4.4 through 7.4.6 and version 7.6.0 may allow an attacker with knowledge of an existing admin account to access the device as a valid admin via an authentication bypass.
Vulnerability in the JD Edwards EnterpriseOne Tools product of Oracle JD Edwards (component: Monitoring and Diagnostics SEC). Supported versions that are affected are Prior to 9.2.9.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise JD Edwards EnterpriseOne Tools. Successful attacks of this vulnerability can result in takeover of JD Edwards EnterpriseOne Tools. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
It was found that default configuration of Heketi does not require any authentication potentially exposing the management interface to misuse. This isue only affects heketi as shipped with Openshift Container Platform 3.11.
Memu Play 6.0.7 contains an insecure file permissions vulnerability that allows low-privilege users to escalate privileges by replacing the MemuService.exe executable. Attackers can rename and overwrite MemuService.exe in the installation directory with a malicious executable, which executes with system-level privileges when the service restarts after a computer reboot.
iSeeQ Hybrid DVR WH-H4 1.03R contains an unauthenticated vulnerability in the get_jpeg script that allows unauthorized access to live video streams. Attackers can retrieve video snapshots from specific camera channels by sending requests to the /cgi-bin/get_jpeg endpoint without authentication.
vBulletin before 5.5.6pl1, 5.6.0 before 5.6.0pl1, and 5.6.1 before 5.6.1pl1 has incorrect access control.
The Web portal of the WiFi module of VPNCrypt M10 2.6.5 allows unauthenticated users to send HTTP POST request to several critical Administrative functions such as, changing credentials of the Administrator account or connect the product to a rogue access point.
If Apache TomEE is configured to use the embedded ActiveMQ broker, and the broker URI includes the useJMX=true parameter, a JMX port is opened on TCP port 1099, which does not include authentication. This affects Apache TomEE 8.0.0-M1 - 8.0.1, Apache TomEE 7.1.0 - 7.1.2, Apache TomEE 7.0.0-M1 - 7.0.7, Apache TomEE 1.0.0 - 1.7.5.
Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to bypass authentication, related to the MySnapCam web service.
Missing Authentication for Critical Function vulnerability in Centreon Infra Monitoring centreon-awie (Awie import module) allows Accessing Functionality Not Properly Constrained by ACLs. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.3, from 24.04.0 before 24.04.3.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port 9999 by default. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-10493.
The CE21 Suite plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 2.2.0. This is due to hardcoded encryption key in the 'ce21_authentication_phrase' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email.
A vulnerability was found in SourceCodester Company Website CMS 1.0. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /dashboard/settings. The manipulation leads to improper authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-206161 was assigned to this vulnerability.
Slican NCP/IPL/IPM/IPU devices are vulnerable to PHP Function Injection. An unauthenticated remote attacker is able to execute arbitrary PHP commands by sending specially crafted requests to /webcti/session_ajax.php endpoint. This issue was fixed in version 1.24.0190 (Slican NCP) and 6.61.0010 (Slican IPL/IPM/IPU).
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain XML messages to a specific port without proper authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to read and modify the affected product’s configuration.
WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction.
CVE-2024-10386 IMPACT An authentication vulnerability exists in the affected product. The vulnerability could allow a threat actor with network access to send crafted messages to the device, potentially resulting in database manipulation.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the HM-Print AddOn through 1.2a installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi and exec1.cgi scripts, which execute TCL script content from an HTTP POST request.
The Really Simple Security (Free, Pro, and Pro Multisite) plugins for WordPress are vulnerable to authentication bypass in versions 9.0.0 to 9.1.1.1. This is due to improper user check error handling in the two-factor REST API actions with the 'check_login_and_get_user' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, when the "Two-Factor Authentication" setting is enabled (disabled by default).
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
GitBucket 4.23.1 contains an unauthenticated remote code execution vulnerability that allows attackers to execute arbitrary commands by exploiting weak secret token generation and insecure file upload functionality. Attackers can brute-force the Blowfish encryption key, upload a malicious JAR plugin via the git-lfs endpoint, and execute system commands through an exposed exploit endpoint.
WordPress Plugin Peugeot Music 1.0 contains an arbitrary file upload vulnerability that allows unauthenticated attackers to upload malicious files by sending POST requests to the upload.php endpoint. Attackers can upload files with arbitrary extensions by manipulating the 'name' parameter to execute code from the uploads directory.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.
The RSA Identity Governance and Lifecycle and RSA Via Lifecycle and Governance products prior to 7.1.1 P03 contain an Improper Authentication vulnerability. A Java JMX agent running on the remote host is configured with plain text password authentication. An unauthenticated remote attacker can connect to the JMX agent and monitor and manage the Java application.
Missing Authentication, Files or Directories Accessible to External Parties, Use of Hard-coded Credentials vulnerability in Talya Informatics Elektraweb allows Authentication Bypass.This issue affects Elektraweb: before v17.0.68.
The InWave Jobs plugin for WordPress is vulnerable to privilege escalation via password reset in all versions up to, and including, 3.5.1. This is due to the plugin not properly validating a user's identity prior to updating their password. This makes it possible for unauthenticated attackers to change arbitrary user's passwords, including administrators, and leverage that to gain access to their account.
Password recovery vulnerability in SICK SIM4000 (PPC) Partnumber 1078787 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.10.1 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM4000. A fix is planned but not yet scheduled.
Vvveb before version 1.0.8.2 contains a hard-coded credentials vulnerability in its docker-compose-apache.yaml configuration that allows unauthenticated attackers to access the bundled phpMyAdmin container with pre-configured database credentials. Attackers can connect to the phpMyAdmin port to gain unrestricted read and write access to the entire Vvveb database, including administrator password hashes, customer personally identifiable information, and order data, enabling account takeover and data manipulation.
All versions of the package django-mdeditor are vulnerable to Missing Authentication for Critical Function in the image upload endpoint. An attacker can upload malicious files and achieve arbitrary code execution since this endpoint lacks authentication protection and proper sanitisation of file names.
The Dingtian DT-R0 Series is vulnerable to an exploit that allows attackers to bypass login requirements by directly navigating to the main page.