Palo Alto Networks PAN-OS contains an out-of-bounds write vulnerability in the User-ID Authentication Portal (aka Captive Portal) service that can allow an unauthenticated attacker to execute arbitrary code with root privileges on the PA-Series and VM-Series firewalls by sending specially crafted packets.
Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable. Until the vendor releases an official fix, the following workaround should be implemented: - Restrict User-ID Authentication Portal access to only trusted zones. - Disable User-ID Authentication Portal if not required. 5/13/2026: Palo Alto has released a variety of patches. If these are relevant to your environment, please apply the designate
A vulnerability has been identified in SICAM PAS/PQS (All versions < V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected component does not correctly validate the root path on folder related operations, allowing to modify files and folders outside the intended root directory. This could allow an unauthenticated remote attacker to execute file operations of files outside of the specified root folder. Chained with CVE-2022-43513 this could allow Remote Code Execution.
A vulnerability has been identified in Siveillance Video Mobile Server V2022 R2 (All versions < V22.2a (80)). The mobile server component of affected applications improperly handles the log in for Active Directory accounts that are part of Administrators group. This could allow an unauthenticated remote attacker to access the application without a valid account.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted packets to 1099/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP1). The affected application is vulnerable to SQL injection. This could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database.
A vulnerability has been identified in Location Intelligence Perpetual Large (9DE5110-8CA13-1AX0) (All versions < V4.3), Location Intelligence Perpetual Medium (9DE5110-8CA12-1AX0) (All versions < V4.3), Location Intelligence Perpetual Non-Prod (9DE5110-8CA10-1AX0) (All versions < V4.3), Location Intelligence Perpetual Small (9DE5110-8CA11-1AX0) (All versions < V4.3), Location Intelligence SUS Large (9DE5110-8CA13-1BX0) (All versions < V4.3), Location Intelligence SUS Medium (9DE5110-8CA12-1BX0) (All versions < V4.3), Location Intelligence SUS Non-Prod (9DE5110-8CA10-1BX0) (All versions < V4.3), Location Intelligence SUS Small (9DE5110-8CA11-1BX0) (All versions < V4.3). Affected products use a hard-coded secret value for the computation of a Keyed-Hash Message Authentication Code. This could allow an unauthenticated remote attacker to gain full administrative access to the application.
A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.
A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions < IP8), Cerberus PRO EN Fire Panel FC72x IP6 (All versions < IP6 SR3), Cerberus PRO EN Fire Panel FC72x IP7 (All versions < IP7 SR5), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions < V3.0.6602), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.0.5016), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions < V3.2.6601), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.2.5015), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions < MP8), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions < MP6 SR3), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions < MP7 SR5), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions < V3.0.6602), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.0.5016), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions < V3.2.6601), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.2.5015), Sinteso Mobile (All versions < V3.0.0). The network communication library in affected systems does not validate the length of certain X.509 certificate attributes which might result in a stack-based buffer overflow. This could allow an unauthenticated remote attacker to execute code on the underlying operating system with root privileges.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout.
A vulnerability has been identified in TeleControl Server Basic V3.1 (All versions >= V3.1.2.2 < V3.1.2.3). The affected application contains an information disclosure vulnerability. This could allow an unauthenticated remote attacker to obtain password hashes of users and to login to and perform authenticated operations of the database service.
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.
A vulnerability has been identified in SICAM P850 (7KG8500-0AA00-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA00-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-2AA0) (All versions < V3.10), SICAM T (All versions < V3.0). Affected devices do not properly validate the parameter of a specific GET request. This could allow an unauthenticated attacker to set the device to a denial of service state or to control the program counter and, thus, execute arbitrary code on the device.
An authentication bypass in Palo Alto Networks PAN-OS software enables an unauthenticated attacker with network access to the management web interface to gain PAN-OS administrator privileges to perform administrative actions, tamper with the configuration, or exploit other authenticated privilege escalation vulnerabilities like CVE-2024-9474 https://security.paloaltonetworks.com/CVE-2024-9474 . The risk of this issue is greatly reduced if you secure access to the management web interface by restricting access to only trusted internal IP addresses according to our recommended best practice deployment guidelines https://live.paloaltonetworks.com/t5/community-blogs/tips-amp-tricks-how-to-secure-the-management-access-of-your-palo/ba-p/464431 . This issue is applicable only to PAN-OS 10.2, PAN-OS 11.0, PAN-OS 11.1, and PAN-OS 11.2 software. Cloud NGFW and Prisma Access are not impacted by this vulnerability.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'VerifyUser' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25914)
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device.
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0). Affected versions of the module insufficiently protect from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled.
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.15), Teamcenter V13.0 (All versions < V13.0.0.10), Teamcenter V13.1 (All versions < V13.1.0.10), Teamcenter V13.2 (All versions < V13.2.0.9), Teamcenter V13.3 (All versions < V13.3.0.5), Teamcenter V14.0 (All versions < V14.0.0.2). File Server Cache service in Teamcenter consist of a functionality that is vulnerable to command injection. This could potentially allow an attacker to perform remote code execution.
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges.
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges.
A vulnerability has been identified in Cerberus DMS (All versions), Desigo CC (All versions), Desigo CC Compact (All versions), SIMATIC WinCC OA V3.16 (All versions in default configuration), SIMATIC WinCC OA V3.17 (All versions in non-default configuration), SIMATIC WinCC OA V3.18 (All versions in non-default configuration). Affected applications use client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a file upload server that is vulnerable to command injection. An attacker could use this to achieve arbitrary code execution.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution.
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
A buffer overflow vulnerability in PAN-OS allows an unauthenticated attacker to disrupt system processes and potentially execute arbitrary code with root privileges by sending a malicious request to the Captive Portal or Multi-Factor Authentication interface. This issue impacts: All versions of PAN-OS 8.0; PAN-OS 8.1 versions earlier than PAN-OS 8.1.15; PAN-OS 9.0 versions earlier than PAN-OS 9.0.9; PAN-OS 9.1 versions earlier than PAN-OS 9.1.3.
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.
Palo Alto Networks PAN-OS before 6.1.19, 7.0.x before 7.0.19, 7.1.x before 7.1.14, and 8.0.x before 8.0.6 allows remote attackers to execute arbitrary code via vectors involving the management interface.
A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions >= V3.3.0 < V3.5.1), Mendix Forgot Password Appstore module (Mendix 7 compatible) (All versions < V3.2.2). Initial passwords are generated in an insecure manner. This could allow an unauthenticated remote attacker to efficiently brute force passwords in specific situations.
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected products do not properly validate the certificate of the configured UMC server. This could allow an attacker to intercept credentials that are sent to the UMC server as well as to manipulate responses, potentially allowing an attacker to escalate privileges.
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.
An off-by-one heap-based buffer overflow was found in the __vsyslog_internal function of the glibc library. This function is called by the syslog and vsyslog functions. This issue occurs when these functions are called with a message bigger than INT_MAX bytes, leading to an incorrect calculation of the buffer size to store the message, resulting in an application crash. This issue affects glibc 2.37 and newer.
A heap-based buffer overflow was found in the __vsyslog_internal function of the glibc library. This function is called by the syslog and vsyslog functions. This issue occurs when the openlog function was not called, or called with the ident argument set to NULL, and the program name (the basename of argv[0]) is bigger than 1024 bytes, resulting in an application crash or local privilege escalation. This issue affects glibc 2.36 and newer.
A heap out-of-bounds write vulnerability in the Linux kernel's Performance Events system component can be exploited to achieve local privilege escalation. A perf_event's read_size can overflow, leading to an heap out-of-bounds increment or write in perf_read_group(). We recommend upgrading past commit 382c27f4ed28f803b1f1473ac2d8db0afc795a1b.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound write buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
Issue summary: The POLY1305 MAC (message authentication code) implementation contains a bug that might corrupt the internal state of applications running on PowerPC CPU based platforms if the CPU provides vector instructions. Impact summary: If an attacker can influence whether the POLY1305 MAC algorithm is used, the application state might be corrupted with various application dependent consequences. The POLY1305 MAC (message authentication code) implementation in OpenSSL for PowerPC CPUs restores the contents of vector registers in a different order than they are saved. Thus the contents of some of these vector registers are corrupted when returning to the caller. The vulnerable code is used only on newer PowerPC processors supporting the PowerISA 2.07 instructions. The consequences of this kind of internal application state corruption can be various - from no consequences, if the calling application does not depend on the contents of non-volatile XMM registers at all, to the worst consequences, where the attacker could get complete control of the application process. However unless the compiler uses the vector registers for storing pointers, the most likely consequence, if any, would be an incorrect result of some application dependent calculations or a crash leading to a denial of service. The POLY1305 MAC algorithm is most frequently used as part of the CHACHA20-POLY1305 AEAD (authenticated encryption with associated data) algorithm. The most common usage of this AEAD cipher is with TLS protocol versions 1.2 and 1.3. If this cipher is enabled on the server a malicious client can influence whether this AEAD cipher is used. This implies that TLS server applications using OpenSSL can be potentially impacted. However we are currently not aware of any concrete application that would be affected by this issue therefore we consider this a Low severity security issue.
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), SICORE Base system (All versions < V26.10.0). The affected application contains an out-of-bounds write vulnerability while parsing specially crafted XML inputs. This could allow an unauthenticated attacker to exploit this issue by sending a malicious XML request, which may cause the service to crash, resulting in a denial-of-service condition.
A vulnerability has been identified in SICAM SIAPP SDK (All versions < V2.1.7). An out-of-bounds write vulnerability exists in SICAM SIAPP SDK. This could allow an attacker to write data beyond the intended buffer, potentially leading to denial of service, or arbitrary code execution.
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted .NEU files. This could allow an attacker to leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-15307)
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain a stack overflow vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15592)
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds write vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap (All versions < V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.260), Parasolid V35.1 (All versions < V35.1.246), Parasolid V36.0 (All versions < V36.0.156), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21266)
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.