An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the accounts ineaadmin and mitsadmin are able to escalate privileges to root without supplying a password due to insecure entries in /etc/sudoers on the RTU.)
A Use of Hard-coded Credentials vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge could allow an attacker to disclose sensitive information and take over accounts.
Denver SHC-150 Smart Wifi Camera contains a hardcoded telnet credential vulnerability that allows unauthenticated attackers to access a Linux shell. Attackers can connect to port 23 using the default credential to execute arbitrary commands on the camera's operating system.
International Datacasting Corporation (IDC) SFX Series SuperFlex Satellite Receiver contains undocumented, hardcoded/insecure credentials for the `xd` user account. A remote unauthenticated attacker can log in via FTP using these credentials. Because the `xd` user has write permissions to their home directory where root-executed binaries and symlinks (such as those invoked by `xdstartstop`) are stored, the attacker can overwrite these files or manipulate symlinks to achieve arbitrary code execution as the root user.
International Datacasting Corporation (IDC) SFX Series SuperFlex(SFX2100) SatelliteReceiver contains hardcoded and insecure credentials for the `admin` account. A remote unauthenticated attacker can use these undocumented credentials to access the satellite system directly via the Telnet service, leading to potential system compromise.
Log files uploaded during troubleshooting by the Harmony SASE agent may have been accessible to unauthorized parties.
Cypress Solutions CTM-200/CTM-ONE 1.3.6 contains hard-coded credentials vulnerability in Linux distribution that exposes root access. Attackers can exploit the static 'Chameleon' password to gain remote root access via Telnet or SSH on affected devices.
Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by hard coded credentials. A hardcoded credential exist in /etc/tomcat8/tomcat-user.xml, which allows attackers to gain authorized access and control the tomcat completely on port 8000 in the tomcat manger page.
A vulnerability has been found in Beetel 777VR1 up to 01.00.09. The impacted element is an unknown function of the component Web Management Interface. The manipulation leads to hard-coded credentials. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. It is advisable to modify the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way.
Root user password is hardcoded into the device and cannot be changed in the user interface.
SDMC NE6037 cable modem routers running firmware 7.1.6.0.25 and 7.1.6.1.9_B9 contain a hardcoded password vulnerability in the web management interface recovery endpoints (mgmt.php, npcmd.php) that allows unauthenticated attackers to gain root access by submitting the hardcoded credential to the recovery endpoint via HTTP. Attackers can leverage this hardcoded password to enable filtered SSH and Telnet services on the device, resulting in unauthenticated root-level remote access to the underlying system.
An issue was discovered in Kaseya Unitrends Backup Appliance before 10.5.5. The SNMP daemon was configured with a weak default community.
Snap One WattBox 800 and 820 series firmware versions prior to 2.10.0.0 contain undisclosed diagnostic HTTP endpoints that require only the device MAC address and service tag for authentication, both of which are printed in plaintext on the physical device label. Attackers with access to the device label or documentation containing these values can authenticate to the several endpoints and execute arbitrary commands as root on the device.
The database account and password are hardcoded, allowing login with the account to manipulate the database in MagicInfo9 Server.This issue affects MagicINFO 9 Server: less than 21.1090.1.
An authentication bypass issue in FormaLMS <= 2.4.4 allows an attacker to bypass the authentication mechanism and obtain a valid access to the platform.
The iRM-IEI Remote Management developed by IEI Integration Corp has a Hardcoded Credentials vulnerability, allowing unauthenticated remote attackers to exploit hard-coded credentials to gain administrative privileges on the database.
ECOA BAS controller is vulnerable to hard-coded credentials within its Linux distribution image, thus remote attackers can obtain administrator’s privilege without logging in.
Multisuns EasyLog web+ has a vulnerability of using hard-coded credentials. An remote attacker can exploit this vulnerability to access the system to perform arbitrary system operations or disrupt service.
Natus NeuroWorks and SleepWorks before 8.4 GMA3 utilize a default password of xltek for the Microsoft SQL Server service sa account, allowing a threat actor to perform remote code execution, data exfiltration, or other nefarious actions such as tampering with data or destroying/disrupting MSSQL services.
A vulnerability in the key-based SSH authentication mechanism of Cisco Policy Suite could allow an unauthenticated, remote attacker to log in to an affected system as the root user. This vulnerability is due to the re-use of static SSH keys across installations. An attacker could exploit this vulnerability by extracting a key from a system under their control. A successful exploit could allow the attacker to log in to an affected system as the root user.
In the DES implementation, the affected product versions use a default key for encryption. Successful exploitation allows an attacker to obtain sensitive information and gain access to the network elements that are managed by the affected products versions. This issue affects * FOXMAN-UN product: FOXMAN-UN R16A, FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C; * UNEM product: UNEM R16A, UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C. List of CPEs: * cpe:2.3:a:hitachienergy:foxman-un:R16A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R16A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
An authentication bypass vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. A specially-crafted HTTP request can lead to unauthorized access. An attacker can send an HTTP request to trigger this vulnerability.
A vulnerability was determined in linlinjava litemall up to 1.8.0. Affected by this issue is some unknown functionality of the file litemall-wx-api/src/main/java/org/linlinjava/litemall/wx/util/JwtHelper.java of the component JSON Web Token Handler. The manipulation of the argument SECRET with the input X-Litemall-Token leads to hard-coded credentials. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
The vulnerability allows a remote attacker to authenticate to the SSH service with root privileges through a hidden hard-coded account.
A vulnerability in Antminer Monitor 0.50.0 exists because of backdoor or misconfiguration inside a settings file in flask server. Settings file has a predefined secret string, which would be randomly generated, however it is static.
A Hardcoded JWT Secret Key in metadata.py in AdaptiveScale LXDUI through 2.1.3 allows attackers to gain admin access to the host system.
Clinic Image System developed by Changing contains hard-coded Credentials, allowing unauthenticated remote attackers to log into the system using administrator credentials embedded in the source code.
D-Link DVG-3104MS version 1.0.2.0.3, 1.0.2.0.4, and 1.0.2.0.4E contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file. As weak passwords have been used, the plaintext passwords can be recovered from the hash values. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
D-Link DVX-2000MS contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file. As weak passwords have been used, the plaintext passwords can be recovered from the hash values.
A hard-coded password vulnerability exists in the telnetd functionality of LevelOne WBR-6013 RER4_A_v3411b_2T2R_LEV_09_170623. A set of specially crafted network packets can lead to arbitrary command execution.
IBM Spectrum Virtualize 8.2, 8.3, and 8.4 could allow an attacker to allow unauthorized access due to the reuse of support generated credentials. IBM X-Force ID: 212609.
D-Link DSR-500N version 1.02 contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file.If an attacker succeeds in recovering the cleartext password of the identified hash value, he will be able to log in via SSH or Telnet and thus gain access to the underlying embedded Linux operating system on the device. Fixed in version 2.12/2. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
Use of Hard-coded Credentials vulnerability in Microchip Time Provider 4100 allows Malicious Manual Software Update.This issue affects Time Provider 4100: before 2.5.0.
Tigo Energy's Cloud Connect Advanced (CCA) device contains hard-coded credentials that allow unauthorized users to gain administrative access. This vulnerability enables attackers to escalate privileges and take full control of the device, potentially modifying system settings, disrupting solar energy production, and interfering with safety mechanisms.
Jalios JCMS 10 allows attackers to access any part of the website and the WebDAV server with administrative privileges via a backdoor account, by using any username and the hardcoded dev password.
The firmware in KAON CG3000TC and CG3000T routers contains hard-coded credentials in clear text (shared across all routers of this model) that an unauthenticated remote attacker could use to execute commands with root privileges. This vulnerability has been fixed in firmware version: 1.00.67 for CG3000TC and 1.00.27 for CG3000T.
ShineLan-X contains a set of credentials for an FTP server was found within the firmware, allowing testers to establish an insecure FTP connection with the server. This may allow an attacker to replace legitimate files being deployed to devices with their own malicious versions, since the firmware signature verification is not enforced.
A vulnerability in Cisco Integrated Management Controller (IMC) Supervisor, Cisco UCS Director, and Cisco UCS Director Express for Big Data could allow an unauthenticated, remote attacker to log in to the CLI of an affected system by using the SCP User account (scpuser), which has default user credentials. The vulnerability is due to the presence of a documented default account with an undocumented default password and incorrect permission settings for that account. Changing the default password for this account is not enforced during the installation of the product. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to execute arbitrary commands with the privileges of the scpuser account. This includes full read and write access to the system's database.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / aisadmin credentials for an ISP.
Use of Hard-coded Credentials vulnerability in Utarit Informatics Services Inc. SoliClub allows Authentication Abuse. This issue affects SoliClub: before 5.3.7.
NetMan 204 contains a hard-coded backdoor account with the username and password 'eurek' that grants administrative access. A remote, unauthenticated attacker can authenticate through the cgi-bin/login.cgi endpoint (for example /cgi-bin/login.cgi?username=eurek&password=eurek, which due to lax parameter validation can be shortened to /cgi-bin/login.cgi?username=eurek%20eurek) to obtain administrator privileges, allowing them to alter device configuration, enable the telnet/SSH services, and reset local user credentials.
Hard-coded login credentials were found in HPE Networking Instant On Access Points, allowing anyone with knowledge of it to bypass normal device authentication. Successful exploitation could allow a remote attacker to gain administrative access to the system.
FUXA v1.2.7 contains a hard-coded credential vulnerability in server/api/jwt-helper.js. The application uses a hard-coded secret key to sign and verify JWT Tokens. This allows remote attackers to forge valid admin tokens and bypass authentication to gain full administrative access.
The Premium Age Verification / Restriction for WordPress plugin for WordPress is vulnerable to arbitrary file read and write due to the existence of an insufficiently protected remote support functionality in remote_tunnel.php in all versions up to, and including, 3.0.2. This makes it possible for unauthenticated attackers to read from or write to arbitrary files on the affected site's server which may make the exposure of sensitive information or remote code execution possible.
RustFS is a distributed object storage system built in Rust. In versions prior to 1.0.0-alpha.78, RustFS implements gRPC authentication using a hardcoded static token `"rustfs rpc"` that is publicly exposed in the source code repository, hardcoded on both client and server sides, non-configurable with no mechanism for token rotation, and universally valid across all RustFS deployments. Any attacker with network access to the gRPC port can authenticate using this publicly known token and execute privileged operations including data destruction, policy manipulation, and cluster configuration changes. Version 1.0.0-alpha.78 contains a fix for the issue.
A vulnerability in the Cisco Common Services Platform Collector (CSPC) could allow an unauthenticated, remote attacker to access an affected device by using an account that has a default, static password. This account does not have administrator privileges. The vulnerability exists because the affected software has a user account with a default, static password. An attacker could exploit this vulnerability by remotely connecting to the affected system using this account. A successful exploit could allow the attacker to log in to the CSPC using the default account. For Cisco CSPC 2.7.x, Cisco fixed this vulnerability in Release 2.7.4.6. For Cisco CSPC 2.8.x, Cisco fixed this vulnerability in Release 2.8.1.2.
Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters.
TX9 Automatic Food Dispenser v3.2.57 devices allow access to a shell as root/superuser, a related issue to CVE-2019-16734. To connect, the telnet service is used on port 23 with the default password of 059AnkJ for the root account. The user can then download the filesystem through preinstalled BusyBox utilities (e.g., tar and nc).
In Ruckus Network Director (RND) < 4.5.0.54, the OVA appliance contains hardcoded credentials for the ruckus PostgreSQL database user. In the default configuration, the PostgreSQL service is accessible over the network on TCP port 5432. An attacker can use the hardcoded credentials to authenticate remotely, gaining superuser access to the database. This allows creation of administrative users for the web interface, extraction of password hashes, and execution of arbitrary OS commands.