An issue was discovered in the Responsive Poll through 1.3.4 for Wordpress. It allows an unauthenticated user to manipulate polls, e.g., delete, clone, or view a hidden poll. This is due to the usage of the callback wp_ajax_nopriv function in Includes/Total-Soft-Poll-Ajax.php for sensitive operations.
vBulletin before 5.5.6pl1, 5.6.0 before 5.6.0pl1, and 5.6.1 before 5.6.1pl1 has incorrect access control.
A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset.
The Really Simple Security (Free, Pro, and Pro Multisite) plugins for WordPress are vulnerable to authentication bypass in versions 9.0.0 to 9.1.1.1. This is due to improper user check error handling in the two-factor REST API actions with the 'check_login_and_get_user' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, when the "Two-Factor Authentication" setting is enabled (disabled by default).
The CE21 Suite plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 2.2.0. This is due to hardcoded encryption key in the 'ce21_authentication_phrase' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email.
The administrative web interface of mySCADA myPRO Manager can be accessed without authentication which could allow an unauthorized attacker to retrieve sensitive information and upload files without the associated password.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
Authentication Bypass Using an Alternate Path or Channel vulnerability in Acnoo Acnoo Flutter API allows Authentication Bypass.This issue affects Acnoo Flutter API: from n/a through 1.0.5.
An authentication bypass in Palo Alto Networks PAN-OS software enables an unauthenticated attacker with network access to the management web interface to gain PAN-OS administrator privileges to perform administrative actions, tamper with the configuration, or exploit other authenticated privilege escalation vulnerabilities like CVE-2024-9474 https://security.paloaltonetworks.com/CVE-2024-9474 . The risk of this issue is greatly reduced if you secure access to the management web interface by restricting access to only trusted internal IP addresses according to our recommended best practice deployment guidelines https://live.paloaltonetworks.com/t5/community-blogs/tips-amp-tricks-how-to-secure-the-management-access-of-your-palo/ba-p/464431 . This issue is applicable only to PAN-OS 10.2, PAN-OS 11.0, PAN-OS 11.1, and PAN-OS 11.2 software. Cloud NGFW and Prisma Access are not impacted by this vulnerability.
Screen SFT DAB 600/C firmware 1.9.3 contains an authentication bypass vulnerability that allows attackers to change the admin password without requiring the current credentials. Attackers can exploit the userManager.cgx API endpoint by sending a crafted POST request with a new MD5-hashed password to directly modify the admin account's authentication.
ASUS Armoury Crate has a vulnerability in arbitrary file write and allows remote attackers to access or modify arbitrary files by sending specific HTTP requests without permission.
Screen SFT DAB 600/C Firmware 1.9.3 contains a session management vulnerability that allows attackers to bypass authentication controls by exploiting IP address session binding. Attackers can reuse the same IP address and issue unauthorized requests to the userManager API to remove user accounts without proper authentication.
SOUND4 IMPACT/FIRST/PULSE/Eco v2.x contains an unauthenticated vulnerability in the /usr/cgi-bin/restorefactory.cgi endpoint that allows remote attackers to reset device configuration. Attackers can send a POST request to the endpoint with specific data to trigger a factory reset and bypass authentication, gaining full system control.
MiniDVBLinux 5.4 contains an authentication bypass vulnerability that allows remote attackers to change the root password without authentication. Attackers can send crafted POST requests to the system setup endpoint with modified SYSTEM_PASSWORD parameters to reset root credentials.
Screen SFT DAB 600/C firmware 1.9.3 contains a session management vulnerability that allows attackers to bypass authentication controls by exploiting IP address session binding. Attackers can reuse the same IP address and issue unauthorized requests to the userManager API to change user passwords without proper authentication.
Missing authentication for critical function in Visual Studio Code extension for Arduino allows an unauthenticated attacker to perform remote code execution through network attack vector.
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. A cfm UDP service listening on port 65002 allows remote, unauthenticated exfiltration of administrative credentials.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.
An issue was discovered in OpServices OpMon 9.3.2 that allows Remote Code Execution .
A ZTE product is impacted by the improper access control vulnerability. Due to lack of an authentication protection mechanism in the program, attackers could use this vulnerability to gain access right through brute-force attacks. This affects: <ZXONE 19700 SNPE><ZXONE8700V1.40R2B13_SNPE>
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
SAP Business Objects Business Intelligence Platform (Live Data Connect), versions 1.0, 2.0, 2.1, 2.2, 2.3, allows an attacker to logon on the Central Management Console without password in case of the BIPRWS application server was not protected with some specific certificate, leading to Missing Authentication Check.
An authentication bypass vulnerability on Genexis Platinum-4410 v2.1 P4410-V2 1.28 devices allows attackers to obtain cleartext credentials from the HTML source code of the cgi-bin/index2.asp URI.
SAP Solution Manager (User Experience Monitoring), version- 7.2, due to Missing Authentication Check does not perform any authentication for a service resulting in complete compromise of all SMDAgents connected to the Solution Manager.
IBM Security Identity Governance and Intelligence 5.2.6 does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. IBM X-Force ID: 192209.
Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur.
Under certain conditions, vmdir that ships with VMware vCenter Server, as part of an embedded or external Platform Services Controller (PSC), does not correctly implement access controls.
The Wordable plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 3.1.1. This is due to the use of a user supplied hashing algorithm passed to the hash_hmac() function and the use of a loose comparison on the hash which allows an attacker to trick the function into thinking it has a valid hash. This makes it possible for unauthenticated attackers to gain administrator privileges.
Selea CarPlateServer 4.0.1.6 contains a remote program execution vulnerability that allows attackers to execute arbitrary Windows binaries by manipulating the NO_LIST_EXE_PATH configuration parameter. Attackers can bypass authentication through the /cps/ endpoint and modify server configuration, including changing admin passwords and executing system commands.
Instantel Micromate lacks authentication on a configuration port which could allow an attacker to execute commands if connected.
A vulnerability in the REST API of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to access the back-end database of an affected system. The vulnerability exists because the affected software does not properly authenticate REST API calls. An attacker could exploit this vulnerability by obtaining a cross-site request forgery (CSRF) token and then using the token with REST API requests. A successful exploit could allow the attacker to access the back-end database of the affected device and read, alter, or drop information.
The official memcached docker images before 1.5.11-alpine (Alpine specific) contain a blank password for a root user. System using the memcached docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
The official composer docker images before 1.8.3 contain a blank password for a root user. System using the composer docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
The official haproxy docker images before 1.8.18-alpine (Alpine specific) contain a blank password for a root user. System using the haproxy docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. Attackers can discover cleartext web-server credentials via certain /opt/lighttpd/web/cgi/ requests.
Unrestricted access to the log downloader functionality in EPSON EPS TSE Server 8 (21.0.11) allows an unauthenticated attacker to remotely retrieve administrative hashed credentials via the maintenance/troubleshoot.php?download=1 URI.
upgrademysqlstatus in databases/views.py in CyberPanel (aka Cyber Panel) before 5b08cd6 allows remote attackers to bypass authentication and execute arbitrary commands via /dataBases/upgrademysqlstatus by bypassing secMiddleware (which is only for a POST request) and using shell metacharacters in the statusfile property, as exploited in the wild in October 2024 by PSAUX. Versions through 2.3.6 and (unpatched) 2.3.7 are affected.
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allow Authentication Bypass in its administrative web interface.
Statistical Database System developed by Gotac has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents with high-level privileges.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port.
An issue was discovered in Electerm 1.3.22, allows attackers to execute arbitrary code via unverified request to electerms service.
OMNTEC Proteus Tank Monitoring OEL8000III Series could allow an attacker to perform administrative actions without proper authentication.
CouchDB version 3.0.0 shipped with a new configuration setting that governs access control to the entire database server called `require_valid_user_except_for_up`. It was meant as an extension to the long standing setting `require_valid_user`, which in turn requires that any and all requests to CouchDB will have to be made with valid credentials, effectively forbidding any anonymous requests. The new `require_valid_user_except_for_up` is an off-by-default setting that was meant to allow requiring valid credentials for all endpoints except for the `/_up` endpoint. However, the implementation of this made an error that lead to not enforcing credentials on any endpoint, when enabled. CouchDB versions 3.0.1[1] and 3.1.0[2] fix this issue.
Lack of access control in Nakivo Backup & Replication Transporter version 9.4.0.r43656 allows remote users to access unencrypted backup repositories and the Nakivo Controller configuration via a network accessible transporter service. It is also possible to create or delete backup repositories.
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
Missing authentication for a critical function in Palo Alto Networks Expedition can lead to an Expedition admin account takeover for attackers with network access to Expedition. Note: Expedition is a tool aiding in configuration migration, tuning, and enrichment. Configuration secrets, credentials, and other data imported into Expedition is at risk due to this issue.
GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute arbitrary commands and send a request to a specific URL that could cause the device to become unresponsive. The unauthenticated attacker may change the password of the 'configuration' user account, allowing the attacker to modify the configuration of the device via the web interface using the new password. This vulnerability may also allow an unauthenticated attacker to bypass the authentication required to configure the device and reboot the system.
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) allows unauthenticated device administration.
If Apache TomEE is configured to use the embedded ActiveMQ broker, and the broker URI includes the useJMX=true parameter, a JMX port is opened on TCP port 1099, which does not include authentication. This affects Apache TomEE 8.0.0-M1 - 8.0.1, Apache TomEE 7.1.0 - 7.1.2, Apache TomEE 7.0.0-M1 - 7.0.7, Apache TomEE 1.0.0 - 1.7.5.
WebAccess/NMS (versions prior to 3.0.2) allows an unauthenticated remote user to create a new admin account.