The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
Advantech R-SeeNet versions 2.4.22 is installed with a hidden root-level user that is not available in the users list. This hidden user has a password that cannot be changed by users.
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.
Arbitrary code execution vlnerability in Operation bridge Manager, Application Performance Management and Operations Bridge (containerized) vulnerability in Micro Focus products products Operation Bridge Manager, Operation Bridge (containerized) and Application Performance Management. The vulneravility affects: 1.) Operation Bridge Manager versions 2020.05, 2019.11, 2019.05, 2018.11, 2018.05, 10.63,10.62, 10.61, 10.60, 10.12, 10.11, 10.10 and all earlier versions. 2.) Operations Bridge (containerized) 2020.05, 2019.08, 2019.05, 2018.11, 2018.08, 2018.05. 2018.02 and 2017.11. 3.) Application Performance Management versions 9,51, 9.50 and 9.40 with uCMDB 10.33 CUP 3. The vulnerability could allow Arbitrary code execution.
An Authorization Bypass vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to access the OBR host as a non-admin user
The Jitsi Meet (aka docker-jitsi-meet) stack on Docker before stable-4384-1 uses default passwords (such as passw0rd) for system accounts.
An issue was discovered on NETGEAR Orbi Tri-Band Business WiFi Add-on Satellite (SRS60) AC3000 V2.5.1.106, Outdoor Satellite (RBS50Y) V2.5.1.106, and Pro Tri-Band Business WiFi Router (SRR60) AC3000 V2.5.1.106. The root account has the same password as the Web-admin component. Thus, by exploiting CVE-2020-11551, it is possible to achieve remote code execution with root privileges on the embedded Linux system.
An issue was discovered in Programi Bilanc build 007 release 014 31.01.2020 and possibly below. During the installation, it sets up administrative access by default with the account admin and password 0000. After the installation, users/admins are not prompted to change this password.
Certain models of D-Link wireless routers contain an undisclosed factory testing backdoor. Unauthenticated attackers on the local area network can force the device to enable Telnet service by accessing a specific URL and can log in by using the administrator credentials obtained from analyzing the firmware.
An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account.
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.
An issue was discovered in Kaseya Unitrends Backup Appliance before 10.5.5. The SNMP daemon was configured with a weak default community.
A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.
Because of hard-coded SSH keys for the root user in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series, Kami7B, an attacker may remotely log in through SSH.
An authentication bypass issue in FormaLMS <= 2.4.4 allows an attacker to bypass the authentication mechanism and obtain a valid access to the platform.
Use of Hard-coded Credentials in EntoneWebEngine in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series and Kami7B allows remote attackers to retrieve and modify the device settings.
This vulnerability allows network-adjacent attackers execute arbitrary code on affected installations of TP-Link Archer A7 Firmware Ver: 190726 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the tdpServer service, which listens on UDP port 20002 by default. This issue results from the use of hard-coded encryption key. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-9652.
In the DES implementation, the affected product versions use a default key for encryption. Successful exploitation allows an attacker to obtain sensitive information and gain access to the network elements that are managed by the affected products versions. This issue affects * FOXMAN-UN product: FOXMAN-UN R16A, FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C; * UNEM product: UNEM R16A, UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C. List of CPEs: * cpe:2.3:a:hitachienergy:foxman-un:R16A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R16A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
The default credentials for the setup HSQL database (HSQLDB) for FileCatalyst Workflow are published in a vendor knowledgebase article. Misuse of these credentials could lead to a compromise of confidentiality, integrity, or availability of the software. The HSQLDB is only included to facilitate installation, has been deprecated, and is not intended for production use per vendor guides. However, users who have not configured FileCatalyst Workflow to use an alternative database per recommendations are vulnerable to attack from any source that can reach the HSQLDB.
Use of Hard-coded Credentials vulnerability in TNB Mobile Solutions Cockpit Software allows Read Sensitive Strings Within an Executable.This issue affects Cockpit Software: before v2.13.
PlaciPy is a placement management system designed for educational institutions. In version 1.0.0, the application uses a hard-coded, static default password for all newly created student accounts. This results in mass account takeover, allowing any attacker to log in as any student once the password is known.
The MyCar Controls of AutoMobility Distribution Inc., mobile application contains hard-coded admin credentials. A remote unauthenticated attacker may be able to send commands to and retrieve data from a target MyCar unit. This may allow the attacker to learn the location of a target, or gain unauthorized physical access to a vehicle. This issue affects AutoMobility MyCar versions prior to 3.4.24 on iOS and versions prior to 4.1.2 on Android. This issue has additionally been fixed in Carlink, Link, Visions MyCar, and MyCar Kia.
D-Link DVX-2000MS contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file. As weak passwords have been used, the plaintext passwords can be recovered from the hash values.
3DP-MANAGER is an inbound generator for 3x-ui. In version 2.0.1 and prior, the application automatically creates an administrative account with known default credentials (admin/admin) upon the first initialization. Attackers with network access to the application's login interface can gain full administrative control, managing VPN tunnels and system settings. This issue will be patched in version 2.0.2.
D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices have a hardcoded password of wrgac25_dlink.2013gui_dir850l for the Alphanetworks account upon device reset, which allows remote attackers to obtain root access via a TELNET session.
D-Link DVG-3104MS version 1.0.2.0.3, 1.0.2.0.4, and 1.0.2.0.4E contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file. As weak passwords have been used, the plaintext passwords can be recovered from the hash values. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
newbee-mall includes pre-seeded administrator accounts in its database initialization script. These accounts are provisioned with a predictable default password. Deployments that initialize or reset the database using the provided schema and fail to change the default administrative credentials may allow unauthenticated attackers to log in as an administrator and gain full administrative control of the application.
Linear eMerge E3-Series devices have Hard-coded Credentials.
Gradio is an open-source Python library to build machine learning and data science demos and web applications. Versions prior to 3.13.1 contain Use of Hard-coded Credentials. When using Gradio's share links (i.e. creating a Gradio app and then setting `share=True`), a private SSH key is sent to any user that connects to the Gradio machine, which means that a user could access other users' shared Gradio demos. From there, other exploits are possible depending on the level of access/exposure the Gradio app provides. This issue is patched in version 3.13.1, however, users are recommended to update to 3.19.1 or later where the FRP solution has been properly tested.
The database account and password are hardcoded, allowing login with the account to manipulate the database in MagicInfo9 Server.This issue affects MagicINFO 9 Server: less than 21.1090.1.
D-Link DIR-615 before v20.12PTb04 has a second admin account with a 0x1 BACKDOOR value, which might allow remote attackers to obtain access via a TELNET connection.
MaLion for Windows and Mac versions 3.2.1 to 5.2.1 uses a hardcoded cryptographic key which may allow an attacker to alter the connection settings of Terminal Agent and spoof the Relay Service.
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device.
Glory RBG-100 recycler systems using the ISPK-08 software component contain hard-coded operating system credentials that allow remote authentication to the underlying Linux system. Multiple local user accounts, including accounts with administrative privileges, were found to have fixed, embedded passwords. An attacker with network access to exposed services such as SSH may authenticate using these credentials and gain unauthorized access to the system. Successful exploitation allows remote access with elevated privileges and may result in full system compromise.
Files present on firmware images could allow an attacker to gain unauthorized access as a root user using hard-coded credentials.
The Telnet service of Rubetek cameras RV-3406, RV-3409, and RV-3411 cameras (firmware versions v342, v339) could allow an remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password. The Telnet service cannot be disabled and this password cannot be changed via standard functionality.
An issue was discovered on FiberHome HG6245D devices through RP2613. A hardcoded GEPON password for root is defined inside /etc/init.d/system-config.sh.
Hard-coded FTP credentials (r:r) are included in the Foscam C1 running firmware 1.9.1.12. Knowledge of these credentials would allow remote access to any cameras found on the internet that do not have port 50021 blocked by an intermediate device.
TL-WR845N(UN)_V4_200909 and TL-WR845N(UN)_V4_190219 was discovered to contain a hardcoded password for the root account which can be obtained by analyzing downloaded firmware or via a brute force attack through physical access to the router.
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
An exploitable Use of Hard-coded Credentials vulnerability exists in the Moxa AWK-3131A Wireless Access Point running firmware 1.1. The device operating system contains an undocumented, privileged (root) account with hard-coded credentials, giving attackers full control of affected devices.
An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP.
The trove service user in (1) Openstack deployment (aka crowbar-openstack) and (2) Trove Barclamp (aka barclamp-trove and crowbar-barclamp-trove) in the Crowbar Framework has a default password, which makes it easier for remote attackers to obtain access via unspecified vectors.
Clinic Image System developed by Changing contains hard-coded Credentials, allowing unauthenticated remote attackers to log into the system using administrator credentials embedded in the source code.
ui/pref/ProxyPrefView.java in weasis-core in Weasis 4.5.1 has a hardcoded key for symmetric encryption of proxy credentials.
MinMax CMS from MinMax Digital Technology contains a hidden administrator account with a fixed password that cannot be removed or disabled from the management interface. Remote attackers who obtain this account can bypass IP access control restrictions and log in to the backend system without being recorded in the system logs.
PrismX MX100 AP controller developed by BROWAN COMMUNICATIONS has a Use of Hard-coded Credentials vulnerability, allowing unauthenticated remote attackers to log in to the database using hardcoded database credentials stored in the firmware.
Baicells Nova 227, Nova 233, and Nova 243 LTE TDD eNodeB devices with firmware through RTS/RTD 3.7.11.3 have hardcoded credentials that are easily discovered and can be used by remote attackers to authenticate via ssh. (The credentials are stored in the firmware, encrypted by the crypt function.)