Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status.
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
An issue was discovered in Veritas NetBackup Flex Scale through 3.0 and Access Appliance through 8.0.100. Unauthenticated remote command execution can occur via the management portal.
The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.
Telepad allows remote unauthenticated users to send instructions to the server to execute arbitrary code without any previous authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
PC Keyboard allows remote unauthenticated users to send instructions to the server to execute arbitrary code without any previous authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device.
An issue discovered in Shenzhen Zhiboton Electronics ZBT WE1626 Router v 21.06.18 allows attackers to escalate privileges via WGET command to the Network Diagnosis endpoint.
KubeView through 0.1.31 allows attackers to obtain control of a Kubernetes cluster because api/scrape/kube-system does not require authentication, and retrieves certificate files that can be used for authentication as kube-admin. NOTE: the vendor's position is that KubeView was a "fun side project and a learning exercise," and not "very secure."
authentik is an open-source identity provider. Versions prior to 2022.11.2 and 2022.10.2 are vulnerable to unauthorized user creation and potential account takeover. With the default flows, unauthenticated users can create new accounts in authentik. If a flow exists that allows for email-verified password recovery, this can be used to overwrite the email address of admin accounts and take over their accounts. authentik 2022.11.2 and 2022.10.2 fix this issue. As a workaround, a policy can be created and bound to the `default-user-settings-flow flow` with the contents `return request.user.is_authenticated`.
The default configuration of Lazy Mouse does not require a password, allowing remote unauthenticated users to execute arbitrary code with no prior authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
In the default configuration of Apache SOAP, an RPCRouterServlet is available without authentication. This gives an attacker the possibility to invoke methods on the classpath that meet certain criteria. Depending on what classes are available on the classpath this might even lead to arbitrary remote code execution. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
An issue was discovered in BACKCLICK Professional 5.9.63. Due to an exposed internal communications interface, it is possible to execute arbitrary system commands on the server.
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication.
An issue was discovered in BACKCLICK Professional 5.9.63. Due to exposed CORBA management services, arbitrary system commands can be executed on the server.
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
Rifatron 5brid DVR contains an unauthenticated vulnerability in the animate.cgi script that allows unauthorized access to live video streams. Attackers can exploit the Mobile Web Viewer module by specifying channel numbers to retrieve sequential video snapshots without authentication.
iSeeQ Hybrid DVR WH-H4 1.03R contains an unauthenticated vulnerability in the get_jpeg script that allows unauthorized access to live video streams. Attackers can retrieve video snapshots from specific camera channels by sending requests to the /cgi-bin/get_jpeg endpoint without authentication.
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Multiple W&T products of the ComServer Series are prone to an authentication bypass. An unathenticated remote attacker, can log in without knowledge of the password by crafting a modified HTTP GET Request.
Anviz access control devices allow remote attackers to issue commands without a password.
A missing authentication for critical function vulnerability [CWE-306] in FortiPresence infrastructure server before version 1.2.1 allows a remote, unauthenticated attacker to access the Redis and MongoDB instances via crafted authentication requests.
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.
Missing Authorization vulnerability in ThemeHunk Advance WordPress Search Plugin.This issue affects Advance WordPress Search Plugin: from n/a through 1.2.1.
An arbitrary code execution vulnerability exists in Arris SURFboard SGB6950AC2 devices. An unauthenticated attacker can exploit this vulnerability to achieve code execution as root.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of BMC Track-It! 20.21.2.109. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authorization of HTTP requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of the service account. Was ZDI-CAN-16709.
Authentication Bypass vulnerability in miniOrange OAuth 2.0 client for SSO plugin <= 1.11.3 at WordPress.
Web page which "wizardpwd.asp" ALLNET Router model WR0500AC is prone to Authorization bypass vulnerability – the password, located at "admin" allows changing the http[s]://wizardpwd.asp/cgi-bin. Does not validate the user's identity and can be accessed publicly.
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
Because the web management interface for Unified Intents' Unified Remote solution does not itself require authentication, a remote, unauthenticated attacker can change or disable authentication requirements for the Unified Remote protocol, and leverage this now-unauthenticated access to run code of the attacker's choosing.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the Script Parser AddOn through 1.8 installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi script, which executes TCL script content from an HTTP POST request.
An authentication bypass vulnerability exists which allows an unauthenticated attacker to control administrator backup functions, leading to compromise of passwords, secrets, and application session tokens stored by the Unified PAM.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.
There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the HM-Print AddOn through 1.2a installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi and exec1.cgi scripts, which execute TCL script content from an HTTP POST request.
The Civi - Job Board & Freelance Marketplace WordPress Theme plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 2.1.4. This is due to a lack of user validation before changing a password. This makes it possible for unauthenticated attackers to change the password of arbitrary users, including administrators, if the attacker knows the username of the victim.
In Progress MOVEit Transfer 11.1 before 11.1.3, a vulnerability has been found that could allow an attacker to sign in without full credentials via the SSH (SFTP) interface. The vulnerability affects only certain SSH (SFTP) configurations, and is applicable only if the MySQL database is being used.
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
A vulnerability was found in SourceCodester Company Website CMS 1.0. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /dashboard/settings. The manipulation leads to improper authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-206161 was assigned to this vulnerability.
Password recovery vulnerability in SICK SIM1000 FX Partnumber 1097816 and 1097817 with firmware version <1.6.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.6.0 as soon as possible (available in SICK Support Portal).
The querier component in Grafana Enterprise Logs 1.1.x through 1.3.x before 1.4.0 does not require authentication when X-Scope-OrgID is used. Versions 1.2.1, 1.3.1, and 1.4.0 contain the bugfix. This affects -auth.type=enterprise in microservices mode
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The HTTP service (default port 5401/tcp) of the SiVMS/SiNVR Video Server contains an authentication bypass vulnerability, even when properly configured with enforced authentication. A remote attacker with network access to the Video Server could exploit this vulnerability to read the SiVMS/SiNVR users database, including the passwords of all users in obfuscated cleartext.
Password recovery vulnerability in SICK SIM4000 (PPC) Partnumber 1078787 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.10.1 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM4000. A fix is planned but not yet scheduled.
Systematic IRIS WebForms 5.4 and its functionalities can be accessed and used without any form of authentication.
The RSA Identity Governance and Lifecycle and RSA Via Lifecycle and Governance products prior to 7.1.1 P03 contain an Improper Authentication vulnerability. A Java JMX agent running on the remote host is configured with plain text password authentication. An unauthenticated remote attacker can connect to the JMX agent and monitor and manage the Java application.
An issue was discovered on D-Link DAP-1360 revision F devices. Remote attackers can start a telnet service without authorization via an undocumented HTTP request. Although this is the primary vulnerability, the impact depends on the firmware version. Versions 609EU through 613EUbeta were tested. Versions through 6.12b01 have weak root credentials, allowing an attacker to gain remote root access. After 6.12b01, the root credentials were changed but the telnet service can still be started without authorization.
Access to the Advantech iView versions prior to v5.7.03.6112 configuration are missing authentication, which may allow an unauthorized attacker to change the configuration and obtain code execution.
AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity.