A missing authentication for critical function in Fortinet FortiProxy versions 7.6.0 through 7.6.1, FortiSwitchManager version 7.2.5, and FortiOS versions 7.4.4 through 7.4.6 and version 7.6.0 may allow an attacker with knowledge of an existing admin account to access the device as a valid admin via an authentication bypass.
HGiga PowerStation has a vulnerability of Information Leakage. An unauthenticated remote attacker can exploit this vulnerability to obtain the administrator's credential. This credential can then be used to login PowerStation or Secure Shell to achieve remote code execution.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.
A lack of authentication vulnerability exists in the HTTP API functionality of GoCast 1.1.3. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an unauthenticated HTTP request to trigger this vulnerability.
The KUKA SystemSoftware V/KSS in versions prior to 8.6.5 is prone to improper access control as an unauthorized attacker can directly read and write robot configurations when access control is not available or not enabled (default).
Rubygems.org is the Ruby community's gem hosting service. Rubygems.org users with MFA enabled would normally be protected from account takeover in the case of email account takeover. However, a workaround on the forgotten password form allows an attacker to bypass the MFA requirement and takeover the account. This vulnerability has been patched in commit 0b3272a.
Missing Authentication for Critical Function in SICK FX0-GENT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
The Flexi Classic and Flexi Soft Gateways SICK UE410-EN3 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN1 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN3S04 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN4 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK FX0-GENT00000 FLEXISOFT EIP GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GMOD00000 FLEXISOFT MOD GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GPNT00000 FLEXISOFT PNET GATEW. with serial number <=2311xxxx with Firmware <=V2.12.0, SICK FX0-GENT00030 FLEXISOFT EIP GATEW.V2 with serial number <=2311xxxx all Firmware versions, SICK FX0-GPNT00030 FLEXISOFT PNET GATEW.V2 with serial number <=2311xxxx all Firmware versions and SICK FX0-GMOD00010 FLEXISOFT MOD GW with serial number <=2311xxxx with Firmware <=V2.11.0 all have Telnet enabled by factory default. No password is set in the default configuration.
A vulnerability in the Contact Center Express (CCX) Editor application of Cisco Unified CCX could allow an unauthenticated, remote attacker to bypass authentication and obtain administrative permissions pertaining to script creation and execution. This vulnerability is due to improper authentication mechanisms in the communication between the CCX Editor and an affected Unified CCX server. An attacker could exploit this vulnerability by redirecting the authentication flow to a malicious server and tricking the CCX Editor into believing the authentication was successful. A successful exploit could allow the attacker to create and execute arbitrary scripts on the underlying operating system of an affected Unified CCX server, as an internal non-root user account.
Missing Authentication for Critical Function in SICK FX0-GPNT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). The supported version that is affected is 12.2.1.3.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Multiple vulnerabilities in Cisco Nexus Dashboard could allow an unauthenticated, remote attacker to execute arbitrary commands, read or upload container image files, or perform a cross-site request forgery attack. For more information about these vulnerabilities, see the Details section of this advisory.
A vulnerability has been identified in Desigo PXC00-E.D V4.10 (All versions < V4.10.111), Desigo PXC00-E.D V5.00 (All versions < V5.0.171), Desigo PXC00-E.D V5.10 (All versions < V5.10.69), Desigo PXC00-E.D V6.00 (All versions < V6.0.204), Desigo PXC00/64/128-U V4.10 (All versions < V4.10.111 only with web module), Desigo PXC00/64/128-U V5.00 (All versions < V5.0.171 only with web module), Desigo PXC00/64/128-U V5.10 (All versions < V5.10.69 only with web module), Desigo PXC00/64/128-U V6.00 (All versions < V6.0.204 only with web module), Desigo PXC001-E.D V4.10 (All versions < V4.10.111), Desigo PXC001-E.D V5.00 (All versions < V5.0.171), Desigo PXC001-E.D V5.10 (All versions < V5.10.69), Desigo PXC001-E.D V6.00 (All versions < V6.0.204), Desigo PXC100-E.D V4.10 (All versions < V4.10.111), Desigo PXC100-E.D V5.00 (All versions < V5.0.171), Desigo PXC100-E.D V5.10 (All versions < V5.10.69), Desigo PXC100-E.D V6.00 (All versions < V6.0.204), Desigo PXC12-E.D V4.10 (All versions < V4.10.111), Desigo PXC12-E.D V5.00 (All versions < V5.0.171), Desigo PXC12-E.D V5.10 (All versions < V5.10.69), Desigo PXC12-E.D V6.00 (All versions < V6.0.204), Desigo PXC200-E.D V4.10 (All versions < V4.10.111), Desigo PXC200-E.D V5.00 (All versions < V5.0.171), Desigo PXC200-E.D V5.10 (All versions < V5.10.69), Desigo PXC200-E.D V6.00 (All versions < V6.0.204), Desigo PXC22-E.D V4.10 (All versions < V4.10.111), Desigo PXC22-E.D V5.00 (All versions < V5.0.171), Desigo PXC22-E.D V5.10 (All versions < V5.10.69), Desigo PXC22-E.D V6.00 (All versions < V6.0.204), Desigo PXC22.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC22.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC22.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC22.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC36.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC36.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC36.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC36.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC50-E.D V4.10 (All versions < V4.10.111), Desigo PXC50-E.D V5.00 (All versions < V5.0.171), Desigo PXC50-E.D V5.10 (All versions < V5.10.69), Desigo PXC50-E.D V6.00 (All versions < V6.0.204), Desigo PXM20-E V4.10 (All versions < V4.10.111), Desigo PXM20-E V5.00 (All versions < V5.0.171), Desigo PXM20-E V5.10 (All versions < V5.10.69), Desigo PXM20-E V6.00 (All versions < V6.0.204). A remote attacker with network access to the device could potentially upload a new firmware image to the devices without prior authentication.
Multiple vulnerabilities in Cisco Nexus Dashboard could allow an unauthenticated, remote attacker to execute arbitrary commands, read or upload container image files, or perform a cross-site request forgery attack. For more information about these vulnerabilities, see the Details section of this advisory.
Vulnerability in the Oracle Hospitality Simphony product of Oracle Food and Beverage Applications (component: Simphony Enterprise Server). Supported versions that are affected are 19.1.0-19.5.4. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Hospitality Simphony. Successful attacks of this vulnerability can result in takeover of Oracle Hospitality Simphony. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A vulnerability classified as critical was found in SourceCodester Online Pizza Ordering System 1.0. Affected by this vulnerability is the function delete_category of the file ajax.php of the component POST Parameter Handler. The manipulation leads to missing authentication. The attack can be launched remotely. The associated identifier of this vulnerability is VDB-221455.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.
Multiple vulnerabilities in Cisco Nexus Dashboard could allow an unauthenticated, remote attacker to execute arbitrary commands, read or upload container image files, or perform a cross-site request forgery attack. For more information about these vulnerabilities, see the Details section of this advisory.
An unauthenticated remote attacker can gain full access on the affected devices as they are shipped without a password by default and setting one is not enforced.
The Dingtian DT-R0 Series is vulnerable to an exploit that allows attackers to bypass login requirements by directly navigating to the main page.
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.
The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device.
An issue discovered in Shenzhen Zhiboton Electronics ZBT WE1626 Router v 21.06.18 allows attackers to escalate privileges via WGET command to the Network Diagnosis endpoint.
An issue was discovered in BACKCLICK Professional 5.9.63. User authentication for accessing the CORBA back-end services can be bypassed.
An issue was discovered in BACKCLICK Professional 5.9.63. Due to exposed CORBA management services, arbitrary system commands can be executed on the server.
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. A cfm UDP service listening on port 65002 allows remote, unauthenticated exfiltration of administrative credentials.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
A missing authentication for critical function vulnerability [CWE-306] in FortiPresence infrastructure server before version 1.2.1 allows a remote, unauthenticated attacker to access the Redis and MongoDB instances via crafted authentication requests.
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.
SMS-based GPS commands can be executed by MiCODUS MV720 GPS tracker without authentication.
Vulnerability in the Oracle Web Applications Desktop Integrator product of Oracle E-Business Suite (component: Upload). Supported versions that are affected are 12.2.3-12.2.11. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Web Applications Desktop Integrator. Successful attacks of this vulnerability can result in takeover of Oracle Web Applications Desktop Integrator. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.
An authentication bypass issue was discovered in Dasan Switch DS2924 web based interface, firmware versions 1.01.18 and 1.02.00, allowing attackers to gain escalated privileges via storing crafted cookies in the web browser.
Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to bypass authentication, related to the MySnapCam web service.
An issue was discovered in OpServices OpMon 9.3.2 that allows Remote Code Execution .
A remote unauthenticated arbitrary code execution vulnerability was discovered in Aruba Airwave Software version(s): Prior to 1.3.2.
The ClearPass Policy Manager web interface is affected by a vulnerability that leads to authentication bypass. Upon successful bypass an attacker could then execute an exploit that would allow to remote command execution in the underlying operating system. Resolution: Fixed in 6.7.13-HF, 6.8.5-HF, 6.8.6, 6.9.1 and higher.
SAP Business Objects Business Intelligence Platform (Live Data Connect), versions 1.0, 2.0, 2.1, 2.2, 2.3, allows an attacker to logon on the Central Management Console without password in case of the BIPRWS application server was not protected with some specific certificate, leading to Missing Authentication Check.
The Civi - Job Board & Freelance Marketplace WordPress Theme plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 2.1.4. This is due to a lack of user validation before changing a password. This makes it possible for unauthenticated attackers to change the password of arbitrary users, including administrators, if the attacker knows the username of the victim.
A ZTE product is impacted by the improper access control vulnerability. Due to lack of an authentication protection mechanism in the program, attackers could use this vulnerability to gain access right through brute-force attacks. This affects: <ZXONE 19700 SNPE><ZXONE8700V1.40R2B13_SNPE>
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
MILLENSYS Vision Tools Workspace 6.5.0.2585 exposes a sensitive configuration endpoint (/MILLENSYS/settings) that is accessible without authentication. This page leaks plaintext database credentials, file share paths, internal license server configuration, and software update parameters. An unauthenticated attacker can retrieve this information by accessing the endpoint directly, potentially leading to full system compromise. The vulnerability is due to missing access controls on a privileged administrative function.
A vulnerability exists allowing attackers, when present in the same network segment as ClearPass' management interface, to make changes to certain databases in ClearPass by crafting HTTP packets. As a result of this attack, a possible complete cluster compromise might occur. Resolution: Fixed in 6.7.13, 6.8.4, 6.9.0 and higher.
An issue was discovered on Libre Wireless LS9 LS1.5/p7040 devices. There is a Authentication Bypass in the Web Interface. This interface does not properly restrict access to internal functionality. Despite presenting a password login page on first access, authentication is not required to access privileged functionality. As such, it's possible to directly access APIs that should not be exposed to an unauthenticated user.
The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface.
Delta Electronics DIAView has multiple vulnerabilities.