Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2026-2944

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-22 Feb, 2026 | 11:02
Updated At-22 Feb, 2026 | 11:02
Rejected At-
Credits

Tosei Online Store Management System ネット店舗管理システム HTTP POST Request monitor.php system os command injection

A security flaw has been discovered in Tosei Online Store Management System ネット店舗管理システム 1.01. Affected is the function system of the file /cgi-bin/monitor.php of the component HTTP POST Request Handler. Performing a manipulation of the argument DevId results in os command injection. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:22 Feb, 2026 | 11:02
Updated At:22 Feb, 2026 | 11:02
Rejected At:
▼CVE Numbering Authority (CNA)
Tosei Online Store Management System ネット店舗管理システム HTTP POST Request monitor.php system os command injection

A security flaw has been discovered in Tosei Online Store Management System ネット店舗管理システム 1.01. Affected is the function system of the file /cgi-bin/monitor.php of the component HTTP POST Request Handler. Performing a manipulation of the argument DevId results in os command injection. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

Affected Products
Vendor
Tosei
Product
Online Store Management System ネット店舗管理システム
Modules
  • HTTP POST Request Handler
Versions
Affected
  • 1.01
Problem Types
TypeCWE IDDescription
CWECWE-78OS Command Injection
CWECWE-77Command Injection
Type: CWE
CWE ID: CWE-78
Description: OS Command Injection
Type: CWE
CWE ID: CWE-77
Description: Command Injection
Metrics
VersionBase scoreBase severityVector
4.06.9MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
3.17.3HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
3.07.3HIGH
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
2.07.5N/A
AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 6.9
Base severity: MEDIUM
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 7.3
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
Version: 3.0
Base score: 7.3
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
Version: 2.0
Base score: 7.5
Base severity: N/A
Vector:
AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
CW.Wong (VulDB User)
Timeline
EventDate
Advisory disclosed2026-02-21 00:00:00
VulDB entry created2026-02-21 01:00:00
VulDB entry last update2026-02-21 18:35:54
Event: Advisory disclosed
Date: 2026-02-21 00:00:00
Event: VulDB entry created
Date: 2026-02-21 01:00:00
Event: VulDB entry last update
Date: 2026-02-21 18:35:54
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.347314
vdb-entry
technical-description
https://vuldb.com/?ctiid.347314
signature
permissions-required
https://vuldb.com/?submit.754579
third-party-advisory
https://github.com/CVE-Hunter-Leo/CVE/issues/9
exploit
issue-tracking
Hyperlink: https://vuldb.com/?id.347314
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.347314
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.754579
Resource:
third-party-advisory
Hyperlink: https://github.com/CVE-Hunter-Leo/CVE/issues/9
Resource:
exploit
issue-tracking
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:22 Feb, 2026 | 11:16
Updated At:23 Feb, 2026 | 18:13

A security flaw has been discovered in Tosei Online Store Management System ネット店舗管理システム 1.01. Affected is the function system of the file /cgi-bin/monitor.php of the component HTTP POST Request Handler. Performing a manipulation of the argument DevId results in os command injection. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.06.9MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.17.3HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Secondary2.07.5HIGH
AV:N/AC:L/Au:N/C:P/I:P/A:P
Type: Secondary
Version: 4.0
Base score: 6.9
Base severity: MEDIUM
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 7.3
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Type: Secondary
Version: 2.0
Base score: 7.5
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:P/I:P/A:P
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-77Primarycna@vuldb.com
CWE-78Primarycna@vuldb.com
CWE ID: CWE-77
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-78
Type: Primary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/CVE-Hunter-Leo/CVE/issues/9cna@vuldb.com
N/A
https://vuldb.com/?ctiid.347314cna@vuldb.com
N/A
https://vuldb.com/?id.347314cna@vuldb.com
N/A
https://vuldb.com/?submit.754579cna@vuldb.com
N/A
Hyperlink: https://github.com/CVE-Hunter-Leo/CVE/issues/9
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?ctiid.347314
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?id.347314
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?submit.754579
Source: cna@vuldb.com
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

653Records found

CVE-2025-15257
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.37% / 58.42%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 17:02
Updated-20 Jan, 2026 | 19:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Edimax BR-6208AC Web-based Configuration formRoute command injection

A security flaw has been discovered in Edimax BR-6208AC 1.02/1.03. Affected by this vulnerability is the function formRoute of the file /gogorm/formRoute of the component Web-based Configuration Interface. The manipulation of the argument strIp/strMask/strGateway results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be exploited. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-Edimax Technology Company Ltd.
Product-br-6208ac_firmwarebr-6208acBR-6208AC
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-6288
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-18.59% / 95.12%
||
7 Day CHG~0.00%
Published-22 Sep, 2021 | 16:38
Updated-04 Aug, 2024 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Edgecore ECS2020 Firmware 1.0.0.0 devices allow Unauthenticated Command Injection via the command1 HTTP header to the /EXCU_SHELL URI.

Action-Not Available
Vendor-edge-coren/a
Product-ecs2020_firmwareecs2020n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-15256
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.50% / 65.67%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 16:32
Updated-13 Jan, 2026 | 21:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Edimax BR-6208AC Web-based Configuration formStaDrvSetup command injection

A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manipulation of the argument rootAPmac leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-Edimax Technology Company Ltd.
Product-br-6208ac_firmwarebr-6208acBR-6208AC
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-42885
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-9.52% / 92.68%
||
7 Day CHG~0.00%
Published-03 Jun, 2022 | 10:50
Updated-04 Aug, 2024 | 03:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK EX1200T V4.1.2cu.5215 contains a remote command injection vulnerability in function setDeviceMac of the file global.so which can control deviceName to attack.

Action-Not Available
Vendor-n/aTOTOLINK
Product-ex1200t_firmwareex1200tn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-1448
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-1.74% / 82.19%
||
7 Day CHG~0.00%
Published-19 Feb, 2025 | 01:31
Updated-19 Feb, 2025 | 14:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Synway SMG Gateway Management Software 9-12ping.php command injection

A vulnerability was found in Synway SMG Gateway Management Software up to 20250204. It has been rated as critical. This issue affects some unknown processing of the file 9-12ping.php. The manipulation of the argument retry leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Synway
Product-SMG Gateway Management Software
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-13069
Matching Score-4
Assigner-QNAP Systems, Inc.
ShareView Details
Matching Score-4
Assigner-QNAP Systems, Inc.
CVSS Score-9.8||CRITICAL
EPSS-5.73% / 90.27%
||
7 Day CHG~0.00%
Published-06 Oct, 2017 | 18:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

QNAP discovered a number of command injection vulnerabilities found in Music Station versions 4.8.6 (for QTS 4.2.x), 5.0.7 (for QTS 4.3.x), and earlier. If exploited, these vulnerabilities may allow a remote attacker to run arbitrary commands on the NAS.

Action-Not Available
Vendor-n/aQNAP Systems, Inc.
Product-music_stationn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-27476
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||CRITICAL
EPSS-0.03% / 9.60%
||
7 Day CHG~0.00%
Published-23 Mar, 2022 | 19:46
Updated-16 Apr, 2025 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation FactoryTalk AssetCentre OS Command Injection

A vulnerability exists in the SaveConfigFile function of the RACompare Service, which may allow for OS command injection. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-factorytalk_assetcentreFactoryTalk AssetCentre
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-13071
Matching Score-4
Assigner-QNAP Systems, Inc.
ShareView Details
Matching Score-4
Assigner-QNAP Systems, Inc.
CVSS Score-9.8||CRITICAL
EPSS-0.91% / 75.48%
||
7 Day CHG~0.00%
Published-22 Nov, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

QNAP has already patched this vulnerability. This security concern allows a remote attacker to run arbitrary commands on the QNAP Video Station 5.1.3 (for QTS 4.3.3), 5.2.0 (for QTS 4.3.4), and earlier.

Action-Not Available
Vendor-QNAP Systems, Inc.
Product-qtsvideo_stationVideo Station
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11045
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.35% / 56.91%
||
7 Day CHG-0.86%
Published-26 Sep, 2025 | 20:32
Updated-29 Sep, 2025 | 19:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WAYOS LQ_04/LQ_05/LQ_06/LQ_07/LQ_09 usb_paswd.asp command injection

A vulnerability was identified in WAYOS LQ_04, LQ_05, LQ_06, LQ_07 and LQ_09 22.03.17. This affects an unknown function of the file /usb_paswd.asp. The manipulation of the argument Name leads to command injection. The attack can be initiated remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-WAYOS
Product-LQ_04LQ_05LQ_07LQ_06LQ_09
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10323
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.21% / 43.69%
||
7 Day CHG+0.07%
Published-12 Sep, 2025 | 19:02
Updated-02 Oct, 2025 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN578W2 wizard_rep.shtml sub_409184 command injection

A vulnerability was found in Wavlink WL-WN578W2 221110. The impacted element is the function sub_409184 of the file /wizard_rep.shtml. The manipulation of the argument sel_EncrypTyp results in command injection. The attack may be performed from remote. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn578w2_firmwarewl-wn578w2WL-WN578W2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10358
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.24% / 47.24%
||
7 Day CHG+0.06%
Published-13 Sep, 2025 | 08:02
Updated-02 Oct, 2025 | 20:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN578W2 wireless.cgi sub_404850 os command injection

A security vulnerability has been detected in Wavlink WL-WN578W2 221110. This affects the function sub_404850 of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn578w2_firmwarewl-wn578w2WL-WN578W2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-10123
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.19% / 40.96%
||
7 Day CHG+0.05%
Published-09 Sep, 2025 | 02:32
Updated-24 Sep, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_static_leases sub_415028 command injection

A vulnerability was determined in D-Link DIR-823X up to 250416. Affected by this vulnerability is the function sub_415028 of the file /goform/set_static_leases. Executing manipulation of the argument Hostname can lead to command injection. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823xdir-823x_firmwareDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-11588
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-6.67% / 91.04%
||
7 Day CHG~0.00%
Published-24 Jul, 2017 | 00:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On Cisco DDR2200 ADSL2+ Residential Gateway DDR2200B-NA-AnnexA-FCC-V00.00.03.45.4E and DDR2201v1 ADSL2+ Residential Gateway DDR2201v1-NA-AnnexA-FCC-V00.00.03.28.3 devices, there is remote command execution via shell metacharacters in the pingAddr parameter to the waitPingqry.cgi URI. The command output is visible at /PingMsg.cmd.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-residential_gateway_firmwareresidential_gatewayn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-0328
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.56% / 67.68%
||
7 Day CHG-0.69%
Published-09 Jan, 2025 | 04:31
Updated-09 Jan, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
KaiYuanTong ECT Platform HTTP POST Request runCode.php command injection

A vulnerability, which was classified as critical, has been found in KaiYuanTong ECT Platform up to 2.0.0. Affected by this issue is some unknown functionality of the file /public/server/runCode.php of the component HTTP POST Request Handler. The manipulation of the argument code leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-KaiYuanTong
Product-ECT Platform
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-11366
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-41.51% / 97.32%
||
7 Day CHG~0.00%
Published-21 Aug, 2017 | 01:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

components/filemanager/class.filemanager.php in Codiad before 2.8.4 is vulnerable to remote command execution because shell commands can be embedded in parameter values, as demonstrated by search_file_type.

Action-Not Available
Vendor-codiadn/a
Product-codiadn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-9916
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-83.57% / 99.26%
||
7 Day CHG-0.48%
Published-13 Oct, 2024 | 19:00
Updated-16 Oct, 2024 | 22:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
HuangDou UTCMS cli.php os command injection

A vulnerability, which was classified as critical, has been found in HuangDou UTCMS V9. Affected by this issue is some unknown functionality of the file app/modules/ut-cac/admin/cli.php. The manipulation of the argument o leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-usualtoolHuangDouhuangdou
Product-usualtoolcmsUTCMSutcms
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-1000219
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.34% / 87.06%
||
7 Day CHG~0.00%
Published-17 Nov, 2017 | 00:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

npm/KyleRoss windows-cpu all versions vulnerable to command injection resulting in code execution as Node.js user

Action-Not Available
Vendor-windows-cpu_projectn/a
Product-windows-cpun/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-1000487
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-7.80% / 91.80%
||
7 Day CHG~0.00%
Published-03 Jan, 2018 | 20:00
Updated-10 Oct, 2024 | 19:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Plexus-utils before 3.0.16 is vulnerable to command injection because it does not correctly process the contents of double quoted strings.

Action-Not Available
Vendor-codehaus-plexusn/aDebian GNU/Linux
Product-debian_linuxplexus-utilsn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-1000009
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-11.10% / 93.31%
||
7 Day CHG~0.00%
Published-13 Jul, 2017 | 20:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Akeneo PIM CE and EE <1.6.6, <1.5.15, <1.4.28 are vulnerable to shell injection in the mass edition, resulting in remote execution.

Action-Not Available
Vendor-akeneon/a
Product-product_information_managementn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-1000220
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-11.82% / 93.57%
||
7 Day CHG~0.00%
Published-17 Nov, 2017 | 01:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

soyuka/pidusage <=1.1.4 is vulnerable to command injection in the module resulting in arbitrary command execution

Action-Not Available
Vendor-pidusage_projectn/a
Product-pidusagen/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-0915
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-1.16% / 78.25%
||
7 Day CHG~0.00%
Published-21 Mar, 2018 | 20:00
Updated-05 Aug, 2024 | 13:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Gitlab Community Edition version 10.2.4 is vulnerable to a lack of input validation in the GitlabProjectsImportService resulting in remote code execution.

Action-Not Available
Vendor-Debian GNU/LinuxGitLab Inc.
Product-debian_linuxgitlabGitLab Community and Enterprise Editions
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-20
Improper Input Validation
CVE-2024-7066
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-2.11% / 83.83%
||
7 Day CHG~0.00%
Published-24 Jul, 2024 | 11:00
Updated-26 Aug, 2024 | 15:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
F-logic DataCube3 HTTP POST Request config_time_sync.php os command injection

A vulnerability was found in F-logic DataCube3 1.0. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /admin/config_time_sync.php of the component HTTP POST Request Handler. The manipulation of the argument ntp_server leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272347.

Action-Not Available
Vendor-f-logicF-logicf-logic
Product-datacube3datacube3_firmwareDataCube3datacube3
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-28033
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-7.3||HIGH
EPSS-0.56% / 67.87%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 09:34
Updated-02 Aug, 2024 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

OS command injection vulnerability exists in WebProxy 1.7.8 and 1.7.9, which may allow a remote unauthenticated attacker to execute an arbitrary OS command with the privilege of the running web server. Note that the developer was unreachable, therefore, users should consider stop using WebProxy 1.7.8 and 1.7.9.

Action-Not Available
Vendor-LunarNight Laboratoryln-lab
Product-WebProxywebproxy
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-28138
Matching Score-4
Assigner-SEC Consult Vulnerability Lab
ShareView Details
Matching Score-4
Assigner-SEC Consult Vulnerability Lab
CVSS Score-7.3||HIGH
EPSS-0.78% / 73.30%
||
7 Day CHG~0.00%
Published-10 Dec, 2024 | 07:35
Updated-03 Nov, 2025 | 22:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
OS Command Injection

An unauthenticated attacker with network access to the affected device's web interface can execute any system command via the "msg_events.php" script as the www-data user. The HTTP GET parameter "data" is not properly sanitized.

Action-Not Available
Vendor-Image Access GmbH
Product-Scan2Net
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-3412
Matching Score-4
Assigner-ZTE Corporation
ShareView Details
Matching Score-4
Assigner-ZTE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.97% / 76.33%
||
7 Day CHG~0.00%
Published-11 Jun, 2019 | 19:20
Updated-04 Aug, 2024 | 19:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

All versions up to BD_R218V2.4 of ZTE MF920 product are impacted by command execution vulnerability. Due to some interfaces do not adequately verify parameters, an attacker can execute arbitrary commands through specific interfaces.

Action-Not Available
Vendor-ZTE Corporation
Product-mf920_firmwaremf920ZTE MF920
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7646
Matching Score-4
Assigner-Snyk
ShareView Details
Matching Score-4
Assigner-Snyk
CVSS Score-9.8||CRITICAL
EPSS-0.18% / 40.04%
||
7 Day CHG~0.00%
Published-07 May, 2020 | 16:34
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

curlrequest through 1.0.1 allows reading any file by populating the file parameter with user input.

Action-Not Available
Vendor-curlrequest_projectn/a
Product-curlrequestcurlrequest
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-27886
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.11% / 88.38%
||
7 Day CHG~0.00%
Published-01 Mar, 2021 | 23:40
Updated-03 Aug, 2024 | 21:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

rakibtg Docker Dashboard before 2021-02-28 allows command injection in backend/utilities/terminal.js via shell metacharacters in the command parameter of an API request. NOTE: this is NOT a Docker, Inc. product.

Action-Not Available
Vendor-docker_dashboard_projectn/a
Product-docker_dashboardn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2005-2773
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-89.46% / 99.54%
||
7 Day CHG~0.00%
Published-02 Sep, 2005 | 04:00
Updated-22 Oct, 2025 | 01:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-04-15||Apply updates per vendor instructions.

HP OpenView Network Node Manager 6.2 through 7.50 allows remote attackers to execute arbitrary commands via shell metacharacters in the (1) node parameter to connectedNodes.ovpl, (2) cdpView.ovpl, (3) freeIPaddrs.ovpl, and (4) ecscmg.ovpl.

Action-Not Available
Vendor-n/aHP Inc.
Product-openview_network_node_managern/aOpenView Network Node Manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-27185
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-14.46% / 94.29%
||
7 Day CHG~0.00%
Published-10 Feb, 2021 | 21:04
Updated-03 Aug, 2024 | 20:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The samba-client package before 4.0.0 for Node.js allows command injection because of the use of process.exec.

Action-Not Available
Vendor-samba-client_projectn/a
Product-samba-clientn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-27447
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||CRITICAL
EPSS-1.46% / 80.56%
||
7 Day CHG~0.00%
Published-21 Dec, 2021 | 17:55
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Mesa Labs AmegaView command injection

Mesa Labs AmegaView version 3.0 is vulnerable to a command injection, which may allow an attacker to remotely execute arbitrary code.

Action-Not Available
Vendor-mesalabsMesa Labs
Product-amegaviewAmegaView
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2005-2793
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-2.94% / 86.17%
||
7 Day CHG~0.00%
Published-02 Sep, 2005 | 04:00
Updated-03 Apr, 2025 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

PHP remote file inclusion vulnerability in welcome.php in phpLDAPadmin 0.9.6 and 0.9.7 allows remote attackers to execute arbitrary PHP code via the custom_welcome_page parameter.

Action-Not Available
Vendor-phpldapadmin_projectn/a
Product-phpldapadminn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-9835
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.91% / 88.04%
||
7 Day CHG~0.00%
Published-05 Dec, 2016 | 08:09
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory traversal vulnerability in file "jcss.php" in Zikula 1.3.x before 1.3.11 and 1.4.x before 1.4.4 on Windows allows a remote attacker to launch a PHP object injection by uploading a serialized file.

Action-Not Available
Vendor-zikulan/a
Product-zikula_application_frameworkn/a
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-25998
Matching Score-4
Assigner-CERT@VDE
ShareView Details
Matching Score-4
Assigner-CERT@VDE
CVSS Score-7.3||HIGH
EPSS-0.51% / 65.86%
||
7 Day CHG~0.00%
Published-12 Mar, 2024 | 08:11
Updated-24 Jan, 2025 | 07:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
PHOENIX CONTACT: Command injection in the OCPP Service

An unauthenticated remote attacker can perform a command injection in the OCPP Service with limited privileges due to improper input validation.

Action-Not Available
Vendor-Phoenix Contact GmbH & Co. KG
Product-charx_sec-3000_firmwarecharx_sec-3000charx_sec-3150_firmwarecharx_sec-3150charx_sec-3050charx_sec-3100_firmwarecharx_sec-3050_firmwarecharx_sec-3100CHARX SEC-3000CHARX SEC-3050CHARX SEC-3150CHARX SEC-3100charx_sec_3100charx_sec_3150charx_sec_3050charx_sec_3000
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-2642
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.3||HIGH
EPSS-0.43% / 62.03%
||
7 Day CHG~0.00%
Published-19 Mar, 2024 | 21:31
Updated-21 Aug, 2025 | 15:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Ruijie RG-NBS2009G-P EXCU_SHELL command injection

A vulnerability was found in Ruijie RG-NBS2009G-P up to 20240305. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /EXCU_SHELL. The manipulation of the argument Command1 leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257281 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Ruijie Networks Co., Ltd.
Product-rg-nbs2009g-p_firmwarerg-nbs2009g-pRG-NBS2009G-Prg-nbs2009g-p_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-21488
Matching Score-4
Assigner-Snyk
ShareView Details
Matching Score-4
Assigner-Snyk
CVSS Score-7.3||HIGH
EPSS-2.20% / 84.12%
||
7 Day CHG+0.51%
Published-30 Jan, 2024 | 05:00
Updated-17 Jun, 2025 | 21:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Versions of the package network before 0.7.0 are vulnerable to Arbitrary Command Injection due to use of the child_process exec function without input sanitization. If (attacker-controlled) user input is given to the mac_address_for function of the package, it is possible for the attacker to execute arbitrary commands on the operating system that this package is being run on.

Action-Not Available
Vendor-forkhqn/a
Product-networknetwork
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-6558
Matching Score-4
Assigner-CERT/CC
ShareView Details
Matching Score-4
Assigner-CERT/CC
CVSS Score-9.8||CRITICAL
EPSS-4.04% / 88.26%
||
7 Day CHG~0.00%
Published-13 Jul, 2018 | 20:00
Updated-06 Aug, 2024 | 01:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
The ASUS RP-AC52 access point, firmware version 1.0.1.1s and possibly earlier, is vulnerable to command injection

A command injection vulnerability exists in apply.cgi on the ASUS RP-AC52 access point, firmware version 1.0.1.1s and possibly earlier, web interface specifically in the action_script parameter. The action_script parameter specifies a script to be executed if the action_mode parameter does not contain a valid state. If the input provided by action_script does not match one of the hard coded options, then it will be executed as the argument of either a system() or an eval() call allowing arbitrary commands to be executed.

Action-Not Available
Vendor-ASUS (ASUSTeK Computer Inc.)
Product-rp-n12_firmwareea-n66rp-n53rp-n14_firmwarerp-n14rp-ac56rp-ac52_firmwareea-n66_firmwarerp-ac52rp-n53_firmwarerp-n12wmp-n12rp-ac56_firmwarewmp-n12_firmwareRP-AC52 Access Point
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9935
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-1.05% / 77.21%
||
7 Day CHG~0.00%
Published-03 Sep, 2025 | 23:02
Updated-29 Sep, 2025 | 18:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N600R cstecgi.cgi sub_4159F8 command injection

A vulnerability was determined in TOTOLINK N600R 4.3.0cu.7866_B20220506. This vulnerability affects the function sub_4159F8 of the file /web_cste/cgi-bin/cstecgi.cgi. Executing manipulation can lead to command injection. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-TOTOLINK
Product-n600r_firmwaren600rN600R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-6655
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-9.8||CRITICAL
EPSS-4.68% / 89.12%
||
7 Day CHG~0.00%
Published-13 Jun, 2017 | 06:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Cloud Foundry Foundation Cloud Foundry release versions prior to v245 and cf-mysql-release versions prior to v31. A command injection vulnerability was discovered in a common script used by many Cloud Foundry components. A malicious user may exploit numerous vectors to execute arbitrary commands on servers running Cloud Foundry.

Action-Not Available
Vendor-n/aCloud Foundry
Product-cf-mysql-releasecf-releaseCloud Foundry
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-26541
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-12.89% / 93.90%
||
7 Day CHG~0.00%
Published-08 Feb, 2021 | 16:16
Updated-03 Aug, 2024 | 20:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The gitlog function in src/index.ts in gitlog before 4.0.4 has a command injection vulnerability.

Action-Not Available
Vendor-gitlog_projectn/a
Product-gitlogn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-3725
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-9.8||CRITICAL
EPSS-5.90% / 90.42%
||
7 Day CHG~0.00%
Published-15 May, 2019 | 15:45
Updated-16 Sep, 2024 | 19:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection vulnerability

RSA Netwitness Platform versions prior to 11.2.1.1 and RSA Security Analytics versions prior to 10.6.6.1 are vulnerable to a Command Injection vulnerability due to missing input validation in the product. A remote unauthenticated malicious user could exploit this vulnerability to execute arbitrary commands on the server.

Action-Not Available
Vendor-RSA Security LLC
Product-security_analyticsnetwitnessRSA Netwitness PlatformRSA Security Analytics
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-34597
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-5.91% / 90.42%
||
7 Day CHG~0.00%
Published-06 Jul, 2022 | 17:00
Updated-03 Aug, 2024 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX1806 v1.0.0.1 was discovered to contain a command injection vulnerability via the function WanParameterSetting.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1806ax1806_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-12987
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-78.36% / 99.00%
||
7 Day CHG-1.16%
Published-27 Dec, 2024 | 16:00
Updated-30 Oct, 2025 | 19:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2025-06-05||Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
DrayTek Vigor2960/Vigor300B Web Management Interface apmcfgupload os command injection

A vulnerability, which was classified as critical, was found in DrayTek Vigor2960 and Vigor300B 1.5.1.4. Affected is an unknown function of the file /cgi-bin/mainfunction.cgi/apmcfgupload of the component Web Management Interface. The manipulation of the argument session leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.5.1.5 is able to address this issue. It is recommended to upgrade the affected component.

Action-Not Available
Vendor-DrayTek Corp.
Product-vigor300bvigor300b_firmwarevigor2960_firmwarevigor2960Vigor300BVigor2960Vigor Routers
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-28908
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-33.29% / 96.80%
||
7 Day CHG~0.00%
Published-24 May, 2021 | 12:44
Updated-04 Aug, 2024 | 16:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command Injection in Nagios Fusion 4.1.8 and earlier allows for Privilege Escalation to nagios.

Action-Not Available
Vendor-n/aNagios Enterprises, LLC
Product-fusionn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-1115
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.3||HIGH
EPSS-0.48% / 64.42%
||
7 Day CHG~0.00%
Published-31 Jan, 2024 | 20:00
Updated-29 May, 2025 | 15:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
openBI Setting.php dlfile os command injection

A vulnerability was found in openBI up to 1.0.8 and classified as critical. This issue affects the function dlfile of the file /application/websocket/controller/Setting.php. The manipulation of the argument phpPath leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252473 was assigned to this vulnerability.

Action-Not Available
Vendor-openbin/a
Product-openbiopenBI
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2016-5065
Matching Score-4
Assigner-CERT/CC
ShareView Details
Matching Score-4
Assigner-CERT/CC
CVSS Score-9.8||CRITICAL
EPSS-0.66% / 70.69%
||
7 Day CHG~0.00%
Published-10 Apr, 2017 | 03:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Sierra Wireless GX 440 devices with ALEOS firmware 4.3.2 allow Embedded_Ace_Set_Task.cgi command injection.

Action-Not Available
Vendor-sierrawirelessn/a
Product-aleos_firmwaregx_440Sierra Wireless GX 440 devices with ALEOS firmware 4.3.2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-20488
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-5.09% / 89.61%
||
7 Day CHG~0.00%
Published-02 Mar, 2020 | 15:06
Updated-05 Aug, 2024 | 02:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on NETGEAR WNR1000V4 1.1.0.54 devices. Multiple actions within the web management interface (setup.cgi) are vulnerable to command injection, allowing remote attackers to execute arbitrary commands, as demonstrated by shell metacharacters in the sysDNSHost parameter.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wnr1000_firmwarewnr1000n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-0295
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.3||HIGH
EPSS-2.07% / 83.67%
||
7 Day CHG~0.00%
Published-08 Jan, 2024 | 03:31
Updated-16 Jun, 2025 | 18:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Totolink LR1200GB cstecgi.cgi setWanCfg os command injection

A vulnerability, which was classified as critical, was found in Totolink LR1200GB 9.1.0u.6619_B20230130. This affects the function setWanCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-249861 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-lr1200gb_firmwarelr1200gbLR1200GB
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-19872
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.65% / 70.38%
||
7 Day CHG~0.00%
Published-27 Nov, 2020 | 14:08
Updated-05 Aug, 2024 | 02:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. The AprolLoader could be used to inject and execute arbitrary unintended commands via an unspecified attack scenario, a different vulnerability than CVE-2019-16364.

Action-Not Available
Vendor-n/aB&R Industrial Automation GmbH
Product-industrial_automation_aproln/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-0298
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.3||HIGH
EPSS-2.07% / 83.67%
||
7 Day CHG~0.00%
Published-08 Jan, 2024 | 05:00
Updated-03 Jun, 2025 | 14:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Totolink N200RE cstecgi.cgi setDiagnosisCfg os command injection

A vulnerability was found in Totolink N200RE 9.3.5u.6139_B20201216. It has been classified as critical. Affected is the function setDiagnosisCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-249864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-n200re_firmwaren200reN200RE
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-0294
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.3||HIGH
EPSS-2.07% / 83.67%
||
7 Day CHG~0.00%
Published-08 Jan, 2024 | 03:00
Updated-17 Jun, 2025 | 20:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Totolink LR1200GB cstecgi.cgi setUssd os command injection

A vulnerability, which was classified as critical, has been found in Totolink LR1200GB 9.1.0u.6619_B20230130. Affected by this issue is the function setUssd of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ussd leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-249860. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-lr1200gb_firmwarelr1200gbLR1200GB
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • ...
  • 5
  • 6
  • 7
  • ...
  • 13
  • 14
  • Next
Details not found