DVP-12SE11T - Denial of Service Vulnerability
Delta Electronics DVP15MC11T lacks proper validation of the modbus/tcp packets and can lead to denial of service.
A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an 'ICS Restart!' message, CEBC.exe restarts the system.
A vulnerability has been found in Delta Electronics DVP32ES2 PLC 1.48 and classified as critical. This vulnerability affects unknown code of the component Password Transmission Handler. The manipulation leads to denial of service. The exploit has been disclosed to the public and may be used. VDB-241582 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Delta Industrial Automation CNCSoft ScreenEditor Versions 1.01.28 (with ScreenEditor Version 1.01.2) and prior are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.
Delta Industrial Automation CNCSoft ScreenEditor, v1.00.96 and prior. An out-of-bounds read overflow can be exploited when a valid user opens a specially crafted, malicious input file due to the lack of validation.
Out-of-bounds Read vulnerability in Delta Electronics DOPSoft.This issue affects DOPSoft: All Versions.
Delta Electronics ISPSoft version 3.0.5 and prior allow an attacker, by opening a crafted file, to cause the application to read past the boundary allocated to a stack object, which could allow execution of code under the context of the application.
Delta Electronics Delta Industrial Automation PMSoft v2.11 or prior has an out-of-bounds read vulnerability that can be executed when processing project files, which may allow an attacker to read confidential information.
ASDA-Soft: Version 5.4.1.0 and prior does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to crash due to lacking user input validation for processing project files. Which may allow an attacker to gain remote code execution with administrator privileges if exploited.
Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to disclose information.
Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior is vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Delta Industrial Automation CNCSoft ScreenEditor, Versions 1.01.23 and prior. Multiple out-of-bounds read vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read information.
Delta Electronics TPEditor Versions 1.97 and prior. An out-of-bounds read may be exploited by processing specially crafted project files. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
Delta Industrial Automation DOPSoft, Version 4.00.08.15 and prior. Multiple out-of-bounds read vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read information and/or crash the application.
Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.84 and prior. An out-of-bounds read vulnerability may cause the software to crash due to lacking user input validation for processing project files.
In Delta Industrial Automation DOPSoft, Version 4.00.06.15 and prior, processing a specially crafted project file may trigger multiple out-of-bounds read vulnerabilities, which may allow information disclosure, remote code execution, or crash of the application.
Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.
Delta Electronics CNCSoft (Version 1.01.30) and prior) is vulnerable to an out-of-bounds read while processing a specific project file, which may allow an attacker to disclose information.
Delta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple out-of-bounds read vulnerabilities may cause information disclosure due to lacking user input validation for processing project files.
Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple out-of-bounds read vulnerabilities may be exploited, allowing information disclosure due to a lack of user input validation for processing specially crafted project files.
Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior performs read operations on a memory buffer where the position can be determined by a value read from a .dpa file. This may cause improper restriction of operations within the bounds of the memory buffer, allow remote code execution, alter the intended control flow, allow reading of sensitive information, or cause the application to crash.
An issue was discovered in Oniguruma 6.x before 6.9.4_rc2. In the function gb18030_mbc_enc_len in file gb18030.c, a UChar pointer is dereferenced without checking if it passed the end of the matched string. This leads to a heap-based buffer over-read.
typed_ast 1.3.0 and 1.3.1 has a handle_keywordonly_args out-of-bounds read. An attacker with the ability to cause a Python interpreter to parse Python source (but not necessarily execute it) may be able to crash the interpreter process. This could be a concern, for example, in a web-based service that parses (but does not execute) Python code. (This issue also affected certain Python 3.8.0-alpha prereleases.)
MediaTek microchips, as used in NETGEAR devices through 2021-11-11 and other devices, mishandle the WPS (Wi-Fi Protected Setup) protocol. (Affected Chipsets MT7603E, MT7610, MT7612, MT7613, MT7615, MT7620, MT7622, MT7628, MT7629, MT7915; Affected Software Versions 7.4.0.0; Out-of-bounds read).
An issue was discovered in Oniguruma 6.x before 6.9.4_rc2. In the function fetch_interval_quantifier (formerly known as fetch_range_quantifier) in regparse.c, PFETCH is called without checking PEND. This leads to a heap-based buffer over-read.
Oniguruma through 6.9.3, as used in PHP 7.3.x and other products, has a heap-based buffer over-read in str_lower_case_match in regexec.c.
There is a Out-of-bounds Read vulnerability in Huawei Smartphone.Successful exploitation of this vulnerability may lead to process crash.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, and CVE-2019-18306. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
ClamAV versions prior to 0.101.2 are susceptible to a denial of service (DoS) vulnerability. An out-of-bounds heap read condition may occur when scanning PE files. An example is Windows EXE and DLL files that have been packed using Aspack as a result of inadequate bound-checking.
Onigmo through 6.2.0 has an out-of-bounds read in parse_char_class because of missing codepoint validation in regenc.c.
RDesktop version 1.8.4 contains multiple out-of-bound access read vulnerabilities in its code, which results in a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. These issues have been fixed in version 1.8.5
In libexpat before 2.2.8, crafted XML input could fool the parser into changing from DTD parsing to document parsing too early; a consecutive call to XML_GetCurrentLineNumber (or XML_GetCurrentColumnNumber) then resulted in a heap-based buffer over-read.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
In mpg123 1.25.0, there is a heap-based buffer over-read in the convert_latin1 function in libmpg123/id3.c. A crafted input will lead to a remote denial of service attack.
An issue was discovered in the simd-json crate before 0.1.15 for Rust. There is an out-of-bounds read and an incorrect crossing of a page boundary.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
JSON is a JSON implementation for Ruby. Starting in version 2.10.0 and prior to version 2.10.2, a specially crafted document could cause an out of bound read, most likely resulting in a crash. Versions prior to 2.10.0 are not vulnerable. Version 2.10.2 fixes the problem. No known workarounds are available.
mq_parse_http in mongoose.c in Mongoose 6.15 has a heap-based buffer over-read.
Transient DOS while handling beacon frames with invalid IE header length.
An out-of-bounds read vulnerability exists in the PORT command parameter extraction functionality of Weston Embedded uC-FTPs v 1.98.00. A specially-crafted set of network packets can lead to denial of service. An attacker can send packets to trigger this vulnerability.This vulnerability occurs when no IP address argument is provided to the `PORT` command.
In Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the NetScaler file parser could crash. This was addressed in wiretap/netscaler.c by improving data validation.
The power consumption module has an out-of-bounds read vulnerability. Successful exploitation of this vulnerability may affect system availability.
In Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the SRVLOC dissector could crash. This was addressed in epan/dissectors/packet-srvloc.c by preventing a heap-based buffer under-read.
CRLF injection vulnerability in Network Center in Synology Router Manager (SRM) before 1.2.3-8017-2 allows remote attackers to cause a denial of service (out-of-bounds read and application crash) via crafted network traffic.