Telesquare SDT-CW3B1 1.1.0 is affected by an OS command injection vulnerability that allows a remote attacker to execute OS commands without any authentication.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function upgrade_filter. This vulnerability allows attackers to execute arbitrary commands via the path and time parameters.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function httpd_debug.asp. This vulnerability allows attackers to execute arbitrary commands via the time parameter.
Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetUSBShareInfo. This vulnerability allows attackers to execute arbitrary commands via the usbOrdinaryUserName parameter.
TOTOLINK X5000R v9.1.0u.6118_B20201102 was discovered to contain a command injection vulnerability in the function NTPSyncWithHost. This vulnerability allows attackers to execute arbitrary commands via the parameter host_time.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetWLanACLSettings. This vulnerability allows attackers to execute arbitrary commands via the wl(0).(0)_maclist parameter.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetStationSettings. This vulnerability allows attackers to execute arbitrary commands via the station_access_enable parameter.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetStaticRouteSettings. This vulnerability allows attackers to execute arbitrary commands via the staticroute_list parameter.
A vulnerability was determined in Sangfor Operation and Maintenance Security Management System 3.0. Impacted is an unknown function of the file /fort/portal_login of the component Frontend. This manipulation of the argument loginUrl causes command injection. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. Upgrading to version 3.0.11 and 3.0.12 is recommended to address this issue. It is advisable to upgrade the affected component.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function ChgSambaUserSettings. This vulnerability allows attackers to execute arbitrary commands via the samba_name parameter.
Input passed to the Pdf() function is shell escaped and passed to child_process.exec() during PDF rendering. However, the shell escape does not properly encode all special characters, namely, semicolon and curly braces. This can be abused to achieve command execution. This problem affects nodepdf 1.3.0.
Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by unauthenticated command injection. The url parameter of the function module downloadAndUpdate is vulnerable to an command Injection. Unfiltered user input is used to generate code which then gets executed when downloading new firmware.
An issue was discovered in D-Link DIR-806 devices. There is a command injection in function hnap_main, which calls system() without checking the parameter that can be controlled by user, and finally allows remote attackers to execute arbitrary shell commands with a special HTTP header.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects XR300 before 1.0.3.68, R7000P before 1.3.3.140, and R6900P before 1.3.3.140.
BeyondTrust Remote Support (RS) and certain older versions of Privileged Remote Access (PRA) contain a critical pre-authentication remote code execution vulnerability. By sending specially crafted requests, an unauthenticated remote attacker may be able to execute operating system commands in the context of the site user.
The iSherlock developed by HGiga has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 3.2.18.2, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects R7800 before 1.0.2.74, R9000 before 1.0.5.2, and XR500 before 2.3.2.66.
BibTeX-ruby before 5.1.0 allows shell command injection due to unsanitized user input being passed directly to the built-in Ruby Kernel.open method through BibTeX.open.
In GenieACS 1.2.x before 1.2.8, the UI interface API is vulnerable to unauthenticated OS command injection via the ping host argument (lib/ui/api.ts and lib/ping.ts). The vulnerability arises from insufficient input validation combined with a missing authorization check.
The SonicWall Secure Remote Access server (version 8.1.0.2-14sv) is vulnerable to a Remote Command Injection vulnerability in its web administrative interface. This vulnerability occurs in the 'extensionsettings' CGI (/cgi-bin/extensionsettings) component responsible for handling some of the server's internal configurations. The CGI application doesn't properly escape the information it's passed when processing a particular multi-part form request involving scripts. The filename of the 'scriptname' variable is read in unsanitized before a call to system() is performed - allowing for remote command injection. Exploitation of this vulnerability yields shell access to the remote machine under the nobody user account. This is SonicWall Issue ID 181195.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function wget_test.asp. This vulnerability allows attackers to execute arbitrary commands via the url parameter.
totolink a3100r V5.9c.4577 is vulnerable to os command injection. The backend of a page is executing the "ping" command, and the input field does not adequately filter special symbols. This can lead to command injection attacks.
Remote Code Execution (RCE) vulnerability exists in D-Link Router DIR-846 DIR846A1_FW100A43.bin and DIR846enFW100A53DLA-Retail.bin. Malicious users can use this vulnerability to use "\ " or backticks to bypass the shell metacharacters in the ssid0 or ssid1 parameters to execute arbitrary commands.This vulnerability is due to the fact that CVE-2019-17509 is not fully patched and can be bypassed by using line breaks or backticks on its basis.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, R7000 before 1.0.11.110, R7100LG before 1.0.0.72, R7900 before 1.0.4.30, R8000 before 1.0.4.62, XR300 before 1.0.3.56, R7000P before 1.3.2.132, R8500 before 1.0.2.144, R6900P before 1.3.2.132, and R8300 before 1.0.2.144.
The Metro Development Server, which is opened by the React Native Community CLI, binds to external interfaces by default. The server exposes an endpoint that is vulnerable to OS command injection. This allows unauthenticated network attackers to send a POST request to the server and run arbitrary executables. On Windows, the attackers can also execute arbitrary shell commands with fully controlled arguments.
Remote Command Execution (RCE) vulnerability exists in HNAP1/control/SetWizardConfig.php in D-Link Router DIR-846 DIR846A1_FW100A43.bin and DIR846enFW100A53DLA-Retail.bin. Malicoius users can use this vulnerability to use "\ " or backticks in the shell metacharacters in the ssid0 or ssid1 parameters to cause arbitrary command execution. Since CVE-2019-17510 vulnerability has not been patched and improved www/hnap1/control/setwizardconfig.php, can also use line breaks and backquotes to bypass.
NETGEAR DGN1000 before 1.1.00.48 is vulnerable to an authentication bypass vulnerability. A remote and unauthenticated attacker can execute arbitrary operating system commands as root by sending crafted HTTP requests to the setup.cgi endpoint. This vulnerability has been observed to be exploited in the wild since at least 2017 and specifically by the Shadowserver Foundation on 2025-02-06 UTC.
A vulnerability, which was classified as critical, was found in DrayTek Vigor2960 and Vigor300B 1.5.1.4. Affected is an unknown function of the file /cgi-bin/mainfunction.cgi/apmcfgupload of the component Web Management Interface. The manipulation of the argument session leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.5.1.5 is able to address this issue. It is recommended to upgrade the affected component.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58.
A vulnerability has been found in D-Link DI-7001 MINI 19.09.19A1/24.04.18B1. The affected element is an unknown function of the file /msp_info.htm. Such manipulation of the argument cmd leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.134, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, LBR1020 before 2.6.3.58, LBR20 before 2.6.3.50, R7800 before 1.0.2.80, R8900 before 1.0.5.26, R9000 before 1.0.5.26, RBS50Y before 2.7.3.22, WNR2000v5 before 1.0.0.76, XR700 before 1.0.1.36, EX6150v2 before 1.0.1.98, EX7300 before 1.0.2.158, EX7320 before 1.0.0.134, RAX10 before 1.0.2.88, RAX120 before 1.2.0.16, RAX70 before 1.0.2.88, EX6100v2 before 1.0.1.98, EX6400 before 1.0.2.158, EX7300v2 before 1.0.0.134, R6700AX before 1.0.2.88, RAX120v2 before 1.2.0.16, RAX78 before 1.0.2.88, EX6410 before 1.0.0.134, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR350 before 4.3.4.7, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, EX6420 before 1.0.0.134, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS350 before 4.3.4.7, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, EX6400v2 before 1.0.0.134, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK352 before 4.3.4.7, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.
TOTOLINK X5000R v9.1.0u.6118_B20201102 was discovered to contain a command injection vulnerability in the function UploadFirmwareFile. This vulnerability allows attackers to execute arbitrary commands via the parameter FileName.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetWLanApcliSettings. This vulnerability allows attackers to execute arbitrary commands via the ApCliKeyStr parameter.
A flaw was found in Exim versions 4.87 to 4.91 (inclusive). Improper validation of recipient address in deliver_message() function in /src/deliver.c may lead to remote command execution.
Vivotek FD8136 devices allow Remote Command Injection, related to BusyBox and wget. NOTE: the vendor sent a clarification on 2019-09-17 explaining that, although this CVE was first populated in July 2019, it is a historical vulnerability that does not apply to any current or recent Vivotek hardware or firmware
TOTOLINK A720R v4.1.5cu.470_B20200911 was discovered to contain a command injection vulnerability in the "Main" function. This vulnerability allows attackers to execute arbitrary commands via the QUERY_STRING parameter.
D-Link device DIR_882 DIR_882_FW1.30B06_Hotfix_02 was discovered to contain a command injection vulnerability in the LocalIPAddress parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.
The management web interface in Palo Alto Networks PAN-OS before 5.0.18, 6.0.x before 6.0.13, 6.1.x before 6.1.10, and 7.0.x before 7.0.5 allows remote attackers to execute arbitrary OS commands via an unspecified API call.
A vulnerability was detected in D-Link DAP-2695 2.00RC131. This affects the function fwupdater_main of the file rgbin of the component Firmware Update Handler. Performing manipulation results in os command injection. The attack may be initiated remotely. This vulnerability only affects products that are no longer supported by the maintainer.
rpi through 0.0.3 allows execution of arbritary commands. The variable pinNumbver in function GPIO within src/lib/gpio.js is used as part of the arguement of exec function without any sanitization.
All versions of the package check-branches are vulnerable to Command Injection check-branches is a command-line tool that is interacted with locally, or via CI, to confirm no conflicts exist in git branches. However, the library follows these conventions which can be abused: 1. It trusts branch names as they are (plain text) 2. It spawns git commands by concatenating user input Since a branch name is potentially a user input - as users can create branches remotely via pull requests, or simply due to privileged access to a repository - it can effectively be abused to run any command.
A vulnerability has been found in wonderwhy-er DesktopCommanderMCP up to 0.2.13. The affected element is the function extractBaseCommand of the file src/command-manager.ts of the component Absolute Path Handler. Such manipulation leads to os command injection. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. The vendor explains: "The usual use case is that AI is asked to do something, picks commands itself, and typically uses simple command names without absolute paths. It's curious why a user would ask the model to bypass restrictions this way. (...) This could potentially be a problem, but we are yet to hear reports of this being an issue in actual workflows. We'll leave this issue open for situations where people may report this as a problem for the long term."
lib/cmd.js in the node-windows package before 1.0.0-beta.6 for Node.js allows command injection via the PID parameter.
A weakness has been identified in D-Link DI-7001 MINI 24.04.18B1. Impacted is an unknown function of the file /upgrade_filter.asp. This manipulation of the argument path causes os command injection. The attack may be initiated remotely. The exploit has been made available to the public and could be exploited.
php-shellcommand versions before 1.6.1 have a command injection vulnerability. Successful exploitation could lead to arbitrary code execution.
mySCADA myPRO: Versions 8.20.0 and prior has a feature to send emails, which may allow an attacker to inject arbitrary operating system commands through a specific parameter.
serial-number through 1.3.0 allows execution of arbritary commands. The "cmdPrefix" argument in serialNumber function is used by the "exec" function without any validation.
On D-Link DIR-818LW Rev.A 2.05.B03 and DIR-860L Rev.B 2.03.B03 devices, unauthenticated remote OS command execution can occur in the soap.cgi service of the cgibin binary via an "&&" substring in the service parameter. NOTE: this issue exists because of an incomplete fix for CVE-2018-6530.