133Vulnerabilities found

CVE-2021-35533
Assigner-Hitachi Energy
ShareView Details
Assigner-Hitachi Energy
CVSS Score-7.5||HIGH
EPSS-0.55% / 67.61%
||
7 Day CHG~0.00%
Published-26 Nov, 2021 | 16:37
Updated-16 Sep, 2024 | 21:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Specially Crafted IEC 60870-5-104 Packet Vulnerability in RTU500 series

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions).

Action-Not Available
Vendor-Hitachi Energy Ltd.
Product-rtu500_firmwarertu500RTU500 series
CWE ID-CWE-20
Improper Input Validation
CVE-2021-35534
Assigner-Hitachi Energy
ShareView Details
Assigner-Hitachi Energy
CVSS Score-7.2||HIGH
EPSS-0.20% / 42.34%
||
7 Day CHG~0.00%
Published-18 Nov, 2021 | 16:35
Updated-16 Sep, 2024 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Insufficient Security Control Vulnerability

Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited this vulnerability, of which the product does not sufficiently restrict access to an internal database tables, could allow anybody with user credentials to bypass security controls that is enforced by the product. Consequently, exploitation may lead to unauthorized modifications on data/firmware, and/or to permanently disabling the product. This issue affects: Hitachi Energy Relion 670 Series 2.0 all revisions; 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.5. Hitachi Energy Relion 670/650 Series 2.1 all revisions. 2.2.0 all revisions; 2.2.4 all revisions; Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions; 2.2.5 versions prior to 2.2.5.2. Hitachi Energy Relion 650 1.0 all revisions. 1.1 all revisions; 1.2 all revisions; 1.3 versions prior to 1.3.0.8; Hitachi Energy GMS600 1.3.0; 1.3.0.1; 1.2.0. Hitachi Energy PWC600 1.0.1 version 1.0.1.4 and prior versions; 1.1.0 version 1.1.0.1 and prior versions.

Action-Not Available
Vendor-Hitachi Energy Ltd.
Product-gms600relion_670_firmwaregms600_firmwarerelion_670relion_650relion_650_firmwarerelion_sam600-io_firmwarerelion_sam600-iopwc600pwc600_firmwareRelion 670/650/SAM600-IORelion 650GMS600Relion 670 SeriesRelion 670/650 SeriesPWC600
CWE ID-CWE-274
Improper Handling of Insufficient Privileges
CWE ID-CWE-269
Improper Privilege Management
CVE-2021-35535
Assigner-Hitachi Energy
ShareView Details
Assigner-Hitachi Energy
CVSS Score-8.1||HIGH
EPSS-0.26% / 49.43%
||
7 Day CHG~0.00%
Published-18 Nov, 2021 | 15:53
Updated-16 Sep, 2024 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Insufficient Security Control Vulnerability

Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions.

Action-Not Available
Vendor-Hitachi Energy Ltd.
Product-relion_670_firmwarerelion_670relion_650relion_650_firmwarerelion_sam600-io_firmwarerelion_sam600-ioRelion 670/650 SeriesRelion 670/650/SAM600-IORelion 670 Series
CWE ID-CWE-1188
Initialization of a Resource with an Insecure Default
CVE-2021-35528
Assigner-Hitachi Energy
ShareView Details
Assigner-Hitachi Energy
CVSS Score-7.2||HIGH
EPSS-0.04% / 12.74%
||
7 Day CHG~0.00%
Published-17 Nov, 2021 | 17:55
Updated-16 Sep, 2024 | 16:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authentication Bypass Vulnerability Vulnerability in Retail Operations Product and Counterparty Settlement and Billing (CSB)

Improper Access Control vulnerability in the application authentication and authorization of Hitachi Energy Retail Operations, Counterparty Settlement and Billing (CSB) allows an attacker to execute a modified signed Java Applet JAR file. A successful exploitation may lead to data extraction or modification of data inside the application. This issue affects: Hitachi Energy Retail Operations 5.7.3 and prior versions. Hitachi Energy Counterparty Settlement and Billing (CSB) 5.7.3 prior versions.

Action-Not Available
Vendor-Hitachi Energy Ltd.
Product-retail_operationscounterparty_settlements_and_billingRetail OperationsCounterparty Settlement and Billing (CSB)
CWE ID-CWE-284
Improper Access Control
CVE-2021-22278
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-6.7||MEDIUM
EPSS-0.02% / 4.49%
||
7 Day CHG~0.00%
Published-28 Oct, 2021 | 12:45
Updated-16 Sep, 2024 | 18:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Certificate verification vulnerability in Update Manager of PCM600 Engineering Tool

A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-update_managerpcm600PCM600PCM600 Update Manager
CWE ID-CWE-295
Improper Certificate Validation
CVE-2021-35526
Assigner-Hitachi Energy
ShareView Details
Assigner-Hitachi Energy
CVSS Score-6.3||MEDIUM
EPSS-0.01% / 0.81%
||
7 Day CHG~0.00%
Published-08 Sep, 2021 | 15:10
Updated-16 Sep, 2024 | 19:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Storage of Sensitive Information Vulnerability in Hitachi ABB Power Grids System Data Manager – SDM600 Product

Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager – SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager – SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257).

Action-Not Available
Vendor-Hitachi Energy Ltd.Hitachi, Ltd.
Product-sdm600_firmwaresdm600System Data Manager – SDM600
CWE ID-CWE-312
Cleartext Storage of Sensitive Information
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-35529
Assigner-Hitachi Energy
ShareView Details
Assigner-Hitachi Energy
CVSS Score-7.7||HIGH
EPSS-0.29% / 52.40%
||
7 Day CHG~0.00%
Published-20 Aug, 2021 | 17:35
Updated-17 Sep, 2024 | 02:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Password in Memory Vulnerability in Retail Operations Product and Counterparty Settlement and Billing (CSB)

Insufficiently Protected Credentials vulnerability in client environment of Hitachi ABB Power Grids Retail Operations and Counterparty Settlement Billing (CSB) allows an attacker or unauthorized user to access database credentials, shut down the product and access or alter. This issue affects: Hitachi ABB Power Grids Retail Operations version 5.7.2 and prior versions. Hitachi ABB Power Grids Counterparty Settlement Billing (CSB) version 5.7.2 and prior versions.

Action-Not Available
Vendor-Hitachi Energy Ltd.Hitachi, Ltd.
Product-retail_operationscounterparty_settlement_and_billingRetail OperationsCounterparty Settlement and Billing (CSB)
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2021-35527
Assigner-Hitachi Energy
ShareView Details
Assigner-Hitachi Energy
CVSS Score-7.5||HIGH
EPSS-0.28% / 50.68%
||
7 Day CHG~0.00%
Published-14 Jul, 2021 | 13:15
Updated-16 Sep, 2024 | 23:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Password Autocomplete Vulnerability in Hitachi ABB Power Grids eSOMS Application

Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions.

Action-Not Available
Vendor-Hitachi Energy Ltd.Hitachi, Ltd.
Product-esomseSOMS
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2021-26845
Assigner-MITRE Corporation
ShareView Details
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.28% / 50.68%
||
7 Day CHG~0.00%
Published-14 Jun, 2021 | 21:25
Updated-16 Sep, 2024 | 18:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
eSOMS Report Function Vulnerability

Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report is discovered. This issue affects: Hitachi ABB Power Grids eSOMS 6.0 versions prior to 6.0.4.2.2; 6.1 versions prior to 6.1.4; 6.3 versions prior to 6.3.

Action-Not Available
Vendor-n/aHitachi Energy Ltd.
Product-esomsn/a
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-27196
Assigner-MITRE Corporation
ShareView Details
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-1.04% / 77.19%
||
7 Day CHG~0.00%
Published-14 Jun, 2021 | 21:20
Updated-17 Sep, 2024 | 03:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Specially Crafted IEC 61850 Protocol Sequence Vulnerability

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.0.7. Hitachi ABB Power Grids REB500 7.3; 7.4; 7.5; 7.6; 8.2; 8.3. Hitachi ABB Power Grids RTU500 Series 7.x version 7.x and prior versions; 8.x version 8.x and prior versions; 9.x version 9.x and prior versions; 10.x version 10.x and prior versions; 11.x version 11.x and prior versions; 12.x version 12.x and prior versions. Hitachi ABB Power Grids FOX615 (TEGO1) R1D02 version R1D02 and prior versions. Hitachi ABB Power Grids MSM 2.1.0 versions prior to 2.1.0. Hitachi ABB Power Grids GMS600 1.3.0 version 1.3.0 and prior versions. Hitachi ABB Power Grids PWC600 1.0 versions prior to 1.0.1.4; 1.1 versions prior to 1.1.0.1.

Action-Not Available
Vendor-n/aHitachi Energy Ltd.
Product-rtu500_firmwaregms600relion_670_firmwarerelion_650_firmwarepwc600rtu500reb500pwc600_firmwaremodular_switchgear_monitoringgms600_firmwarerelion_670relion_650reb500_firmwarerelion_sam600-io_firmwarefox615_tego1relion_sam600-iofox615_tego1_firmwaremodular_switchgear_monitoring_firmwaren/a
CWE ID-CWE-20
Improper Input Validation
CVE-2019-5620
Assigner-Rapid7, Inc.
ShareView Details
Assigner-Rapid7, Inc.
CVSS Score-9.8||CRITICAL
EPSS-79.33% / 99.05%
||
7 Day CHG~0.00%
Published-29 Apr, 2020 | 22:15
Updated-17 Sep, 2024 | 03:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB MicroSCADA Pro SYS600 Missing Authentication for Critical Function

ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.

Action-Not Available
Vendor-Hitachi Energy Ltd.Microsoft CorporationABB
Product-microscada_pro_sys600windows_7windows_xpMicroSCADA Pro SYS600
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-19002
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-6.3||MEDIUM
EPSS-0.28% / 50.79%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:50
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB eSOMS X-XSS-Protection not enabled

For ABB eSOMS versions 4.0 to 6.0.2, the X-XSS-Protection HTTP response header is not set in responses from the web server. For older web browser not supporting Content Security Policy, this might increase the risk of Cross Site Scripting.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CWE ID-CWE-16
Not Available
CVE-2019-19001
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-6.5||MEDIUM
EPSS-0.38% / 58.94%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:49
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
eSOMS X-FrameOption

For ABB eSOMS versions 4.0 to 6.0.2, the X-Frame-Options header is not configured in HTTP response. This can potentially allow 'ClickJacking' attacks where an attacker can frame parts of the application on a malicious web site, revealing sensitive user information such as authentication credentials.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-16
Not Available
CWE ID-CWE-1021
Improper Restriction of Rendered UI Layers or Frames
CVE-2019-19000
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-6.5||MEDIUM
EPSS-0.21% / 43.39%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:49
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
eSOMS Cachecontrol (Pragma) HTTP Header

For ABB eSOMS 4.0 to 6.0.3, the Cache-Control and Pragma HTTP header(s) have not been properly configured within the application response. This can potentially allow browsers and proxies to cache sensitive information.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-16
Not Available
CWE ID-CWE-202
Exposure of Sensitive Information Through Data Queries
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-19097
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-5.9||MEDIUM
EPSS-0.15% / 35.62%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:48
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB eSOMS: SSL medium strength Cipher Suites

ABB eSOMS versions 4.0 to 6.0.3 accept connections using medium strength ciphers. If a connection is enabled using such a cipher, an attacker might be able to eavesdrop and/or intercept the connection.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-326
Inadequate Encryption Strength
CWE ID-CWE-16
Not Available
CVE-2019-19096
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-6.1||MEDIUM
EPSS-0.05% / 15.36%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:48
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB eSOMS: REDIS clear text credentials

The Redis data structure component used in ABB eSOMS versions 6.0 to 6.0.2 stores credentials in clear text. If an attacker has file system access, this can potentially compromise the credentials' confidentiality.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-257
Storing Passwords in a Recoverable Format
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2019-19095
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-5.4||MEDIUM
EPSS-0.30% / 53.16%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:47
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB eSOMS: Stored XSS vulnerability

Lack of adequate input/output validation for ABB eSOMS versions 4.0 to 6.0.2 might allow an attacker to attack such as stored cross-site scripting by storing malicious content in the database.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2019-19094
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-7.6||HIGH
EPSS-0.35% / 57.04%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:47
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB eSOMS: SQL injection vulnerability

Lack of input checks for SQL queries in ABB eSOMS versions 3.9 to 6.0.3 might allow an attacker SQL injection attacks against the backend database.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-19093
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-6.5||MEDIUM
EPSS-0.19% / 40.35%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:47
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB eSOMS: Password complexity issue

eSOMS versions 4.0 to 6.0.3 do not enforce password complexity settings, potentially resulting in lower access security due to insecure user passwords.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-521
Weak Password Requirements
CVE-2019-19092
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-3.5||LOW
EPSS-0.20% / 41.99%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:47
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB eSOMS: Viewstate without MAC Signature

ABB eSOMS versions 4.0 to 6.0.3 use ASP.NET Viewstate without Message Authentication Code (MAC). Alterations to Viewstate might thus not be noticed.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-16
Not Available
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-19091
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-4.3||MEDIUM
EPSS-0.23% / 45.30%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:46
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB eSOMS: HTTP response information leakage

For ABB eSOMS versions 4.0 to 6.0.3, HTTPS responses contain comments with sensitive information about the application. An attacker might use this detail information to specifically craft the attack.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-16
Not Available
CWE ID-CWE-202
Exposure of Sensitive Information Through Data Queries
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-19090
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-3.5||LOW
EPSS-0.16% / 37.11%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:46
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB eSOMS: Secure Flag not set

For ABB eSOMS versions 4.0 to 6.0.2, the Secure Flag is not set in the HTTP response header. Unencrypted connections might access the cookie information, thus making it susceptible to eavesdropping.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-16
Not Available
CWE ID-CWE-311
Missing Encryption of Sensitive Data
CVE-2019-19089
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-6.1||MEDIUM
EPSS-0.37% / 58.43%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:46
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
eSOMS: X-Content-Type-Options Header Missing

For ABB eSOMS versions 4.0 to 6.0.3, the X-Content-Type-Options Header is missing in the HTTP response, potentially causing the response body to be interpreted and displayed as different content type other than declared. A possible attack scenario would be unauthorized code execution via text interpreted as JavaScript.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-16
Not Available
CWE ID-CWE-436
Interpretation Conflict
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2019-19003
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-5.3||MEDIUM
EPSS-0.37% / 58.45%
||
7 Day CHG~0.00%
Published-02 Apr, 2020 | 19:46
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB eSOMS: HTTPOnly flag not set

For ABB eSOMS versions 4.0 to 6.0.2, the HTTPOnly flag is not set. This can allow Javascript to access the cookie contents, which in turn might enable Cross Site Scripting.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-esomseSOMS
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CWE ID-CWE-16
Not Available
CVE-2019-18998
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-7.1||HIGH
EPSS-0.13% / 32.49%
||
7 Day CHG~0.00%
Published-17 Feb, 2020 | 18:40
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Asset Suite Direct Object Reference Access

Insufficient access control in the web interface of ABB Asset Suite versions 9.0 to 9.3, 9.4 prior to 9.4.2.6, 9.5 prior to 9.5.3.2 and 9.6.0 enables full access to directly referenced objects. An attacker with knowledge of a resource's URL can access the resource directly.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-asset_suiteAsset Suite
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CVE-2019-18253
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||CRITICAL
EPSS-0.53% / 66.58%
||
7 Day CHG~0.00%
Published-27 Nov, 2019 | 22:05
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An attacker could use specially crafted paths in a specific request to read or delete files from Relion 670 Series (versions 1p1r26, 1.2.3.17, 2.0.0.10, RES670 2.0.0.4, 2.1.0.1, and prior) outside the intended directory.

Action-Not Available
Vendor-n/aHitachi Energy Ltd.
Product-relion_670relion_670_firmwareRelion 670 Series
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2019-18247
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.55% / 67.51%
||
7 Day CHG~0.00%
Published-27 Nov, 2019 | 22:03
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An attacker may use a specially crafted message to force Relion 650 series (versions 1.3.0.5 and prior) or Relion 670 series (versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior) to reboot, which could cause a denial of service.

Action-Not Available
Vendor-n/aHitachi Energy Ltd.
Product-relion_670relion_650relion_670_firmwarerelion_650_firmwareRelion 650 and 670 Series
CWE ID-CWE-20
Improper Input Validation
CVE-2018-20720
Assigner-MITRE Corporation
ShareView Details
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-1.07% / 77.46%
||
7 Day CHG~0.00%
Published-16 Jan, 2019 | 03:00
Updated-05 Aug, 2024 | 12:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

ABB Relion 630 devices 1.1 before 1.1.0.C0, 1.2 before 1.2.0.B3, and 1.3 before 1.3.0.A6 allow remote attackers to cause a denial of service (reboot) via a reboot command in an SPA message.

Action-Not Available
Vendor-n/aHitachi Energy Ltd.
Product-relion_630_firmwarerelion_630n/a
CWE ID-CWE-20
Improper Input Validation
CVE-2018-14805
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-1.32% / 79.60%
||
7 Day CHG~0.00%
Published-29 Aug, 2018 | 16:00
Updated-17 Sep, 2024 | 04:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

ABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonymous authentication, and specific key values within the eSOMS web.config file are present. Both conditions are required to exploit this vulnerability.

Action-Not Available
Vendor-ICS-CERTHitachi Energy Ltd.
Product-esomsABB eSOMS
CWE ID-CWE-287
Improper Authentication
CVE-2018-1168
Assigner-Zero Day Initiative
ShareView Details
Assigner-Zero Day Initiative
CVSS Score-7.8||HIGH
EPSS-0.10% / 28.04%
||
7 Day CHG~0.00%
Published-21 Feb, 2018 | 14:00
Updated-05 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.

Action-Not Available
Vendor-Hitachi Energy Ltd.ABB
Product-sys600_firmwaresys600ABB MicroSCADA
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2017-16731
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.10% / 26.73%
||
7 Day CHG~0.00%
Published-20 Dec, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Unprotected Transport of Credentials issue was discovered in ABB Ellipse 8.3 through Ellipse 8.9 released prior to December 2017 (including Ellipse Select). A vulnerability exists in the authentication of Ellipse to LDAP/AD using the LDAP protocol. An attacker could exploit the vulnerability by sniffing local network traffic, allowing the discovery of authentication credentials.

Action-Not Available
Vendor-n/aHitachi Energy Ltd.
Product-ellipseABB Ellipse
CWE ID-CWE-522
Insufficiently Protected Credentials
CWE ID-CWE-523
Unprotected Transport of Credentials
CVE-2017-14025
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.5||MEDIUM
EPSS-0.21% / 43.61%
||
7 Day CHG~0.00%
Published-06 Nov, 2017 | 22:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Input Validation issue was discovered in ABB FOX515T release 1.0. An improper input validation vulnerability has been identified, allowing a local attacker to provide a malicious parameter to the script that is not validated by the application, This could enable the attacker to retrieve any file on the server.

Action-Not Available
Vendor-n/aHitachi Energy Ltd.
Product-fox515tfox515t_firmwareABB FOX515T
CWE ID-CWE-20
Improper Input Validation
CVE-2017-15583
Assigner-MITRE Corporation
ShareView Details
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.36% / 57.68%
||
7 Day CHG~0.00%
Published-18 Oct, 2017 | 08:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The embedded web server on ABB Fox515T 1.0 devices is vulnerable to Local File Inclusion. It accepts a parameter that specifies a file for display or for use as a template. The filename is not validated; an attacker could retrieve any file.

Action-Not Available
Vendor-n/aHitachi Energy Ltd.
Product-fox515tfox515t_firmwaren/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor