Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
If a specific sequence of actions is performed when opening a new tab, the triggering principal associated with the new tab may have been incorrect. The triggering principal is used to calculate many values, including the `Referer` and `Sec-*` headers, meaning there is the potential for incorrect security checks within the browser in addition to incorrect or misleading information sent to remote websites. *This bug only affects Firefox for Android. Other versions of Firefox are unaffected.* This vulnerability affects Firefox < 127.
D-Link routers with the mydlink feature have some web interfaces without authentication requirements. An attacker can remotely obtain users' DNS query logs and login logs. Vulnerable targets include but are not limited to the latest firmware versions of DIR-817LW (A1-1.04), DIR-816L (B1-2.06), DIR-816 (B1-2.06?), DIR-850L (A1-1.09), and DIR-868L (A1-1.10).
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.8), SiPass integrated ACC-AP (All versions < V6.4.8). Affected devices expose several MQTT URLs without authentication. This could allow an unauthenticated remote attacker to access sensitive data.
Zoho ManageEngine ServiceDesk Plus before 13001 allows anyone to know the organisation's default currency name.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code.
A vulnerability is in the 'live_mfg.html' page of the WAVLINK AC1200, version WAVLINK-A42W-1.27.6-20180418, which can allow a remote attacker to access this page without any authentication. When processed, it exposes some key information of the manager of router.
An information disclosure vulnerability was reported in Lenovo XClarity Administrator (LXCA) versions prior to 2.6.6 that could allow unauthenticated access to some configuration files which may contain usernames, license keys, IP addresses, and encrypted password hashes.
In TOTOLINK EX1200T V4.1.2cu.5215, an attacker can obtain sensitive information (wifikey, etc.) without authorization through getSysStatusCfg.
An issue was discovered on Samsung mobile devices with N(7.x) and O(8.x) software. S-Voice leaks keyboard learned words via the lock screen. The Samsung ID is SVE-2018-12981 (February 2019).
An improper access control vulnerability exists in Gitlab EE <v12.3.3, <v12.2.7, & <v12.1.13 that allowed the group search feature with Elasticsearch to return private code, merge requests and commits.
FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. By default, SIP requests of the type SUBSCRIBE are not authenticated in the affected versions of FreeSWITCH. Abuse of this security issue allows attackers to subscribe to user agent event notifications without the need to authenticate. This abuse poses privacy concerns and might lead to social engineering or similar attacks. For example, attackers may be able to monitor the status of target SIP extensions. Although this issue was fixed in version v1.10.6, installations upgraded to the fixed version of FreeSWITCH from an older version, may still be vulnerable if the configuration is not updated accordingly. Software upgrades do not update the configuration by default. SIP SUBSCRIBE messages should be authenticated by default so that FreeSWITCH administrators do not need to explicitly set the `auth-subscriptions` parameter. When following such a recommendation, a new parameter can be introduced to explicitly disable authentication.
openstack-utils openstack-db has insecure password creation
userfiles/modules/users/controller/controller.php in Microweber before 1.1.20 allows an unauthenticated user to disclose the users database via a /modules/ POST request.
An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed externally without any authentication. All the pages follow the naming convention live_(string).shtml. Among the information disclosed is: interface status logs, IP address of the device, MAC address of the device, model and current firmware version, location, all running processes, all interfaces and their statuses, all current DHCP leases and the associated hostnames, all other wireless networks in range of the router, memory statistics, and components of the configuration of the device such as enabled features. Affected devices: Affected devices are: Wavlink WN530HG4, Wavlink WN575A3, Wavlink WN579G3,Wavlink WN531G3, Wavlink WN533A8, Wavlink WN531A6, Wavlink WN551K1, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, WN572HG3, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
A flaw was found in the CloudForms web interface, versions 5.8 - 5.10, where the RSS feed URLs are not properly restricted to authenticated users only. An attacker could use this flaw to view potentially sensitive information from CloudForms including data such as newly created virtual machines.
All versions up to BD_R218V2.4 of ZTE MF920 product are impacted by information leak vulnerability. Due to some interfaces can obtain the WebUI login password without login, an attacker can exploit the vulnerability to obtain sensitive information about the affected components.
An information disclosure vulnerability in the /cgi-bin/ExportAllSettings.sh endpoint of the WAVLINK WN530H4 M30H4.V5030.190403 allows an attacker to leak router settings, including cleartext login details, DNS settings, and other sensitive information without authentication.
The Amcrest IP2M-841B V2.520.AC00.18.R, Dahua IPC-XXBXX V2.622.0000000.9.R, Dahua IPC HX5X3X and HX4X3X V2.800.0000008.0.R, Dahua DH-IPC HX883X and DH-IPC-HX863X V2.622.0000000.7.R, Dahua DH-SD4XXXXX V2.623.0000000.7.R, Dahua DH-SD5XXXXX V2.623.0000000.1.R, Dahua DH-SD6XXXXX V2.640.0000000.2.R and V2.623.0000000.1.R, Dahua NVR5XX-4KS2 V3.216.0000006.0.R, Dahua NVR4XXX-4KS2 V3.216.0000006.0.R, and NVR2XXX-4KS2 do not require authentication to access the HTTP endpoint /videotalk. An unauthenticated, remote person can connect to this endpoint and potentionally listen to the audio of the capturing device.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allow any user to obtain the presentation passcode via the iso.3.6.1.4.1.3212.100.3.2.7.4 OIDs. A remote, unauthenticated attacker can use this vulnerability to access a restricted presentation or to become the presenter.
Wipro Holmes Orchestrator 20.4.1 (20.4.1_02_11_2020) allows remote attackers to download arbitrary files, such as reports containing sensitive information, because authentication is not required for API access to processexecution/DownloadExcelFile/Domain_Credential_Report_Excel, processexecution/DownloadExcelFile/User_Report_Excel, processexecution/DownloadExcelFile/Process_Report_Excel, processexecution/DownloadExcelFile/Infrastructure_Report_Excel, or processexecution/DownloadExcelFile/Resolver_Report_Excel.
Missing Authentication for Critical Function vulnerability in icegram Icegram allows Accessing Functionality Not Properly Constrained by ACLs.This issue affects Icegram: from n/a through 3.1.24.
Advantech WebAccess 8.3.4 does not properly restrict an RPC call that allows unauthenticated, remote users to read files. An attacker can use this vulnerability to recover the administrator password.
Grundfos CIM 500 before v06.16.00 responds to unauthenticated requests for password storage files.
IBM Security Directory Server 6.4.0 does not perform an authentication check for a critical resource or functionality allowing anonymous users access to protected areas. IBM X-Force ID: 165953.
On 2.1.15 version and below of Lider module in LiderAhenk software is leaking it's configurations via an unsecured API. An attacker with an access to the configurations API could get valid LDAP credentials.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code.
An Incorrect Access Control vulnerability was found in /smsa/view_subject.php in Kashipara Responsive School Management System v3.2.0, which allows remote unauthenticated attackers to view SUBJECT details.
SourceCodester Best House Rental Management System v1.0 is vulnerable to Incorrect Access Control via /rental/payment_report.php, /rental/balance_report.php, /rental/invoices.php, /rental/tenants.php, and /rental/users.php.
An Incorrect Access Control vulnerability was found in /smsa/admin_student_register_approval.php and /smsa/admin_student_register_approval_submit.php in Kashipara Responsive School Management System v3.2.0, which allows remote unauthenticated attackers to view and approve student registration.
An Incorrect Access Control vulnerability was found in /smsa/view_class.php in Kashipara Responsive School Management System v3.2.0, which allows remote unauthenticated attackers to view CLASS details.
An Incorrect Access Control vulnerability was found in /smsa/view_students.php in Kashipara Responsive School Management System v3.2.0, which allows remote unauthenticated attackers to view STUDENT details.
An Incorrect Access Control vulnerability was found in /smsa/admin_dashboard.php in Kashipara Responsive School Management System v3.2.0, which allows remote unauthenticated attackers to view administrator dashboard.
aEnrich Technology a+HRD's functionality for front-end retrieval of system configuration values lacks proper restrictions on a specific parameter, allowing attackers to modify this parameter to access certain sensitive system configuration values.
antd-admin 5.5.0 is affected by an incorrect access control vulnerability. Unauthorized access to some interfaces in the foreground leads to leakage of sensitive information.
An improper access control (CWE-284) vulnerability in FortiWLC version 8.6.0, version 8.5.3 and below, version 8.4.8 and below, version 8.3.3 and below, version 8.2.7 to 8.2.4, version 8.1.3 may allow an unauthenticated and remote attacker to access certain areas of the web management CGI functionality by just specifying the correct URL. The vulnerability applies only to limited CGI resources and might allow the unauthorized party to access configuration details.
Argo CD is a declarative, GitOps continuous delivery tool for Kubernetes. The vulnerability allows unauthorized access to the sensitive settings exposed by /api/v1/settings endpoint without authentication. All sensitive settings are hidden except passwordPattern. This vulnerability is fixed in 2.11.3, 2.10.12, and 2.9.17.
An information disclosure vulnerability exists in the web interface /cgi-bin/download_config.cgi functionality of Peplink Smart Reader v1.2.0 (in QEMU). A specially crafted HTTP request can lead to a disclosure of sensitive information. An attacker can make an unauthenticated HTTP request to trigger this vulnerability.
An issue exists on NightOwl WDB-20-V2 WDB-20-V2_20190314 devices that allows an unauthenticated user to gain access to snapshots and video streams from the doorbell. The binary app offers a web server on port 80 that allows an unauthenticated user to take a snapshot from the doorbell camera via the /snapshot URI.
Northern.tech Mender before 3.6.5 and 3.7.x before 3.7.5 has Incorrect Access Control.
Adobe Commerce versions 2.4.7, 2.4.6-p5, 2.4.5-p7, 2.4.4-p8 and earlier are affected by an Improper Access Control vulnerability that could result in a Security feature bypass. An attacker could leverage this vulnerability to bypass security measures and view minor unauthorised information. Exploitation of this issue does not require user interaction.
Admin authentication can be bypassed with some specific invalid credentials, which allows logging in with an administrative privilege. Sharp Corporation states the telnet feature is implemented on older models only, and is planning to provide the firmware update to remove the feature. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References].
An issue was discovered in Emote Remote Mouse through 4.0.0.0. Attackers can retrieve recently used and running applications, their icons, and their file paths. This information is sent in cleartext and is not protected by any authentication logic.
HashiCorp Vault Enterprise 0.9.2 through 1.6.2 allowed the read of license metadata from DR secondaries without authentication. Fixed in 1.6.3.
Automox Agent prior to version 31 uses an insufficiently protected S3 bucket endpoint for storing sensitive files, which could be brute-forced by an attacker to subvert an organization's security program. The issue has since been fixed in version 31 of the Automox Agent.
An information disclosure vulnerability exists in the web interface /cgi-bin/debug_dump.cgi functionality of Peplink Smart Reader v1.2.0 (in QEMU). A specially crafted HTTP request can lead to a disclosure of sensitive information. An attacker can make an unauthenticated HTTP request to trigger this vulnerability.
Philips MRI 1.5T and MRI 3T Version 5.x.x does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
Separate Groups mode restrictions were not honored in the H5P attempts report, which would display users from other groups. By default this only provided additional access to non-editing teachers.
EBM Technologies RISWEB's specific URL path is not properly controlled by permission, allowing attackers to browse specific pages and query sensitive data without login.