A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18318 and CVE-2019-18319. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIPORT MP (All versions < 3.2.1). Vulnerable versions of the device could allow an authenticated attacker to impersonate other users of the system and perform (potentially administrative) actions on behalf of those users if the single sign-on feature ("Allow logon without password") is enabled.
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability. A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. A remote attacker with network access to the CCS server could exploit this vulnerability to read the CCS users database, including the passwords of all users in obfuscated cleartext.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to directory listings of the server by sending specifically crafted packets to 80/tcp, 8095/tcp or 8080/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to upload arbitrary files without authentication. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The Application Server exposes directory listings and files containing sensitive information. This vulnerability is independent from CVE-2019-18287. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server can cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18317 and CVE-2019-18319. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The Application Server exposes directory listings and files containing sensitive information. This vulnerability is independent from CVE-2019-18286. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could be able to read and write arbitrary files on the local file system by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18322. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted packets to 8888/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18317 and CVE-2019-18318. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted objects via RMI. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could be able to enumerate running RPC services. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.
A vulnerability has been identified in TeleControl Server Basic < V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations.
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device.
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device's management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users.
A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 < V7.1 Upd3), SIMATIC IT UA Discrete Manufacturing (Versions < V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.4). An attacker with network access to the installation could bypass the application-level authentication. In order to exploit the vulnerability, an attacker must obtain network access to an affected installation and must obtain a valid username to the system. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known.
A vulnerability has been identified in TIM 1531 IRC (All version < V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known.
A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.
ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (ephemeral-association demobilization) by sending a spoofed crypto-NAK packet with incorrect authentication data at a certain time.
A vulnerability has been identified in Siveillance Video Mobile Server V2022 R2 (All versions < V22.2a (80)). The mobile server component of affected applications improperly handles the log in for Active Directory accounts that are part of Administrators group. This could allow an unauthenticated remote attacker to access the application without a valid account.
A vulnerability has been identified in Cerberus DMS (All versions), Desigo CC (All versions), Desigo CC Compact (All versions), SIMATIC WinCC OA V3.16 (All versions in default configuration), SIMATIC WinCC OA V3.17 (All versions in non-default configuration), SIMATIC WinCC OA V3.18 (All versions in non-default configuration). Affected applications use client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated.
A vulnerability has been identified in Opcenter Quality V13.1 (All versions < V13.1.20220624), Opcenter Quality V13.2 (All versions < V13.2.20220624). The affected applications do not properly validate login information during authentication. This could lead to denial of service condition for existing users or allow unauthenticated remote attackers to successfully login without credentials.
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations.
A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions < V2.6.6), SICAM GridEdge Essential Intel (All versions < V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions < V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions < V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of an user, such as credentials, in case that user's id is known.
NTP 4.x before 4.2.8p6 and 4.3.x before 4.3.90 do not verify peer associations of symmetric keys when authenticating packets, which might allow remote attackers to conduct impersonation attacks via an arbitrary trusted key, aka a "skeleton key."
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not restrict unauthenticated access to certain pages of the web interface. This could allow an attacker to delete log files without authentication.
An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process (CP) of the RNA series module, if network access to Port 102/TCP is available and the configuration file for the CP is stored on the RNA's CPU.
Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings.
A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.
A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication.
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password.
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device.
The firmware on GateHouse; Harris BGAN RF-7800B-VU204 and BGAN RF-7800B-DU204; Hughes Network Systems 9201, 9450, and 9502; Inmarsat; Japan Radio JUE-250 and JUE-500; and Thuraya IP satellite terminals does not require authentication for sessions on TCP port 1827, which allows remote attackers to execute arbitrary code via unspecified protocol operations.
D-Link DIR-615 Wireless N 300 Router allows authentication bypass via a modified POST request to login.cgi. This issue occurs because it fails to validate the password field. Successful exploitation of this issue allows an attacker to take control of the affected device.
On certain Brother devices, authorization is mishandled by including a valid AuthCookie cookie in the HTTP response to a failed login attempt. Affected models are: MFC-J6973CDW MFC-J4420DW MFC-8710DW MFC-J4620DW MFC-L8850CDW MFC-J3720 MFC-J6520DW MFC-L2740DW MFC-J5910DW MFC-J6920DW MFC-L2700DW MFC-9130CW MFC-9330CDW MFC-9340CDW MFC-J5620DW MFC-J6720DW MFC-L8600CDW MFC-L9550CDW MFC-L2720DW DCP-L2540DW DCP-L2520DW HL-3140CW HL-3170CDW HL-3180CDW HL-L8350CDW HL-L2380DW ADS-2500W ADS-1000W ADS-1500W.
AIRTAME HDMI dongle with firmware before 2.2.0 allows unauthenticated access to a big part of the management interface. It is possible to extract all information including the Wi-Fi password, reboot, or force a software update at an arbitrary time.
The network enabled distribution of Kura before 2.1.0 takes control over the device's firewall setup but does not allow IPv6 firewall rules to be configured. Still the Equinox console port 5002 is left open, allowing to log into Kura without any user credentials over unencrypted telnet and executing commands using the Equinox "exec" command. As the process is running as "root" full control over the device can be acquired. IPv6 is also left in auto-configuration mode, accepting router advertisements automatically and assigns a MAC address based IPv6 address.
EMC NetWorker may potentially be vulnerable to an unauthenticated remote code execution vulnerability in the Networker Client execution service (nsrexecd) when oldauth authentication method is used. An unauthenticated remote attacker could send arbitrary commands via RPC service to be executed on the host system with the privileges of the nsrexecd service, which runs with administrative privileges.
License Manager Service of YOKOGAWA products (CENTUM VP (R5.01.00 - R6.06.00), CENTUM VP Entry Class (R5.01.00 - R6.06.00), ProSafe-RS (R3.01.00 - R4.04.00), PRM (R4.01.00 - R4.02.00), B/M9000 VP(R7.01.01 - R8.02.03)) allows remote attackers to bypass access restriction to send malicious files to the PC where License Manager Service runs via unspecified vectors.
An issue was discovered in dnaTools dnaLIMS 4-2015s13. dnaLIMS is vulnerable to unauthenticated command execution through an improperly protected administrative web shell (cgi-bin/dna/sysAdmin.cgi POST requests).
The Adaptive Security Device Management (ASDM) remote-management feature in Cisco Adaptive Security Appliance (ASA) Software 8.2.x before 8.2(5.46), 8.3.x before 8.3(2.39), 8.4.x before 8.4(6), 8.5.x before 8.5(1.18), 8.6.x before 8.6(1.12), 8.7.x before 8.7(1.7), 9.0.x before 9.0(3.1), and 9.1.x before 9.1(2.6) does not properly implement the authentication-certificate option, which allows remote attackers to bypass authentication via a TCP session to an ASDM interface, aka Bug ID CSCuh44815.
A vulnerability in the web-based GUI of Cisco Prime Home could allow an unauthenticated, remote attacker to bypass authentication and execute actions with administrator privileges. The vulnerability is due to a processing error in the role-based access control (RBAC) of URLs. An attacker could exploit this vulnerability by sending API commands via HTTP to a particular URL without prior authentication. An exploit could allow the attacker to perform any actions in Cisco Prime Home with administrator privileges. This vulnerability affects Cisco Prime Home versions from 6.3.0.0 to the first fixed release 6.5.0.1. Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability. Cisco Bug IDs: CSCvb49837.
Unspecified vulnerability in a cryptographic feature in MailEnable Standard Edition before 1.93, Professional Edition before 1.73, and Enterprise Edition before 1.21 leads to "weakened authentication security" with unknown impact and attack vectors. NOTE: due to lack of details, it is not clear whether this is the same as CVE-2006-1792.
A vulnerability in the web-based GUI of Cisco Mobility Express 1800 Series Access Points could allow an unauthenticated, remote attacker to bypass authentication. The attacker could be granted full administrator privileges. The vulnerability is due to improper implementation of authentication for accessing certain web pages using the GUI interface. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web interface of the affected system. A successful exploit could allow the attacker to bypass authentication and perform unauthorized configuration changes or issue control commands to the affected device. This vulnerability affects Cisco Mobility Express 1800 Series Access Points running a software version prior to 8.2.110.0. Cisco Bug IDs: CSCuy68219.
EMC Network Configuration Manager (NCM) 9.3.x, EMC Network Configuration Manager (NCM) 9.4.0.x, EMC Network Configuration Manager (NCM) 9.4.1.x, EMC Network Configuration Manager (NCM) 9.4.2.x contains an Improper Authentication vulnerability that could potentially be exploited by malicious users to compromise the affected system.