Advantech WebAccess 8.3.2 and below is vulnerable to a stack buffer overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability by sending a crafted HTTP request to broadweb/system/opcImg.asp.
upAdminPg.asp in Advantech WebAccess before 7.2 allows remote authenticated users to discover credentials by reading HTML source code.
Incorrect permissions are set to default on the ‘Project Management’ page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator’s password and login as an administrator to escalate privileges on the system.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "sta_log_htm" API which are not properly sanitized before being concatenated to OS level commands.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "export_log" API which are not properly sanitized before being concatenated to OS level commands.
A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "mp_apply" API which are not properly sanitized before being concatenated to OS level commands.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "scan_ap" API which are not properly sanitized before being concatenated to OS level commands.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "snmp_apply" API which are not properly sanitized before being concatenated to OS level commands.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "lan_apply" API which are not properly sanitized before being concatenated to OS level commands.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "connection_profile_apply" API which are not properly sanitized before being concatenated to OS level commands.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands.
The VBWinExec function in Node\AspVBObj.dll in Advantech WebAccess 8.3.0 allows remote attackers to execute arbitrary OS commands via a single argument (aka the command parameter).
A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password.
Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by an command injection vulnerability in the device name input field, which can be triggered by authenticated users via a crafted POST request.
Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by an command injection vulnerability in the NTP server input field, which can be triggered by authenticated users via a crafted POST request.
Advantech WebAccess/VPN versions prior to 1.1.5 contain a command injection vulnerability in AppManagementController.appUpgradeAction() that allows an authenticated system administrator to execute arbitrary commands as the web server user (www-data) by supplying a crafted uploaded filename.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "certificate_file_remove" API which are not properly sanitized before being concatenated to OS level commands.
An OS Command Injection vulnerability exists in the ping.php script functionality of Advantech R-SeeNet v 2.4.12 (20.10.2020). A specially crafted HTTP request can lead to arbitrary OS command execution. An attacker can send a crafted HTTP request to trigger this vulnerability.
WebAccess/NMS (versions prior to 3.0.2) does not properly sanitize user input and may allow an attacker to inject system commands remotely.
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple command injection vulnerabilities, caused by a lack of proper validation of user-supplied data, may allow remote code execution.
A Command Injection issue in the traceroute feature on TP-Link TL-WR841N V13 (JP) with firmware versions prior to 201216 allows authenticated users to execute arbitrary code as root via shell metacharacters, a different vulnerability than CVE-2018-12577.
A vulnerability in the web-based management interface of Cisco Small Business RV110W, RV130, RV130W, and RV215W Series Routers could allow an authenticated, remote attacker to inject arbitrary shell commands that are executed by an affected device. The vulnerability is due to insufficient input validation of user-supplied data. An attacker could exploit this vulnerability by sending a crafted request to the web-based management interface of an affected device. A successful exploit could allow the attacker to execute arbitrary shell commands or scripts with root privileges on the affected device.
Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 could allow a remote authenticated attacker to execute arbitrary commands on the system. By sending a specially crafted string, an attacker could modify the device name of an attached PLC adapter to inject and execute arbitrary commands on the system with root privileges.
Openshift has shell command injection flaws due to unsanitized data being passed into shell commands.
A vulnerability in the NX-API feature of Cisco NX-OS Software could allow an authenticated, remote attacker to execute arbitrary commands with root privileges. The vulnerability is due to incorrect input validation of user-supplied data by the NX-API subsystem. An attacker could exploit this vulnerability by sending malicious HTTP or HTTPS packets to the management interface of an affected system that has the NX-API feature enabled. A successful exploit could allow the attacker to perform a command-injection attack and execute arbitrary commands with root privileges. Note: NX-API is disabled by default. MDS 9000 Series Multilayer Switches are affected running software versions prior to 8.1(1b) and 8.2(3). Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected running software versions prior to 7.3(4)N1(1). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 7000 and 7700 Series Switches are affected running software versions prior to 7.3(3)D1(1) and 8.2(3).
McAfee Email Gateway 7.6 allows remote authenticated administrators to execute arbitrary commands via shell metacharacters in the value attribute in a (1) TestFile XML element or the (2) hostname. NOTE: this issue can be combined with CVE-2013-7092 to allow remote attackers to execute commands.
An issue was discovered in rConfig 3.9.2. An attacker can directly execute system commands by sending a GET request to search.crud.php because the catCommand parameter is passed to the exec function without filtering, which can lead to command execution.
A vulnerability in the update service of Cisco Webex Meetings Desktop App and Cisco Webex Productivity Tools for Windows could allow an authenticated, local attacker to execute arbitrary commands as a privileged user. The vulnerability is due to insufficient validation of user-supplied parameters. An attacker could exploit this vulnerability by invoking the update service command with a crafted argument. An exploit could allow the attacker to run arbitrary commands with SYSTEM user privileges. While the CVSS Attack Vector metric denotes the requirement for an attacker to have local access, administrators should be aware that in Active Directory deployments, the vulnerability could be exploited remotely by leveraging the operating system remote management tools. This vulnerability is fixed in Cisco Webex Meetings Desktop App Release 33.6.6 and 33.9.1 releases. This vulnerability is fixed in Cisco Webex Productivity Tools Release 33.0.7.
An issue was discovered on D-Link DSR-250 3.17 devices. Certain functionality in the Unified Services Router web interface could allow an authenticated attacker to execute arbitrary commands, due to a lack of validation of inputs provided in multipart HTTP POST requests.
A security flaw has been discovered in Tenda HG3 2.0 300003070. This vulnerability affects the function formgponConf of the file /boaform/admin/formgponConf. The manipulation of the argument fmgpon_loid results in os command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks.
A vulnerability was detected in Tenda HG3 2.0. The impacted element is an unknown function of the file /boaform/formCountrystr. The manipulation of the argument countrystr results in os command injection. The attack may be performed from remote. The exploit is now public and may be used.
NetApp OnCommand System Manager 2.1 and earlier allows remote attackers to inject arbitrary commands in the Halt/Reboot interface.
Jenkins Selection tasks Plugin 1.0 and earlier executes a user-specified program on the Jenkins controller, allowing attackers with Job/Configure permission to execute an arbitrary system command on the Jenkins controller as the OS user that the Jenkins process is running as.
SQL injection vulnerability in the Help Desk application in Wave EMBASSY Remote Administration Server (ERAS) allows remote authenticated users to execute arbitrary SQL commands via the ct100$4MainController$TextBoxSearchValue parameter (aka the search field), leading to execution of operating-system commands.
ginkgosnmp.inc in HP System Management Homepage (SMH) allows remote authenticated users to execute arbitrary commands via shell metacharacters in the PATH_INFO to smhutil/snmpchp.php.en.
OS command injection vulnerability in the "qs" procedure from the "utils" module in Chicken before 4.9.0.
An OS Command Injection vulnerability in the PAN-OS web management interface allows authenticated administrators to execute arbitrary OS commands with root privileges by sending a malicious request to generate new certificates for use in the PAN-OS configuration. This issue affects: All versions of PAN-OS 8.0; PAN-OS 7.1 versions earlier than PAN-OS 7.1.26; PAN-OS 8.1 versions earlier than PAN-OS 8.1.13.
A vulnerability in the Cisco SD-WAN Solution could allow an authenticated, remote attacker to overwrite arbitrary files on the underlying operating system of an affected device. The vulnerability is due to improper input validation of the save command in the CLI of the affected software. An attacker could exploit this vulnerability by modifying the save command in the CLI of an affected device. A successful exploit could allow the attacker to overwrite arbitrary files on the underlying operating system of an affected device and escalate their privileges to the root user.
app/call_centers/cmd.php in the Call Center Queue Module in FusionPBX up to 4.5.7 suffers from a command injection vulnerability due to a lack of input validation, which allows authenticated attackers (with at least the permission call_center_queue_add or call_center_queue_edit) to execute any commands on the host as www-data.
Polycom HDX Video End Points before 3.0.4 and UC APL before 2.7.1.J allows remote authenticated users to execute arbitrary commands as demonstrated by a ; (semicolon) to the ping command feature.
The device-management command-line interface in Palo Alto Networks PAN-OS 4.0.x before 4.0.9 and 4.1.x before 4.1.2 allows remote authenticated administrators to execute arbitrary commands via unspecified vectors, aka Ref ID 34595.