Ruckus vRioT through 1.5.1.0.21 has an API backdoor that is hardcoded into validate_token.py. An unauthenticated attacker can interact with the service API by using a backdoor value as the Authorization header.
The firmware of the PLANET Technology Corp NVR-915 and NVR-1615 before 2020-10-28 embeds default credentials for root access via telnet. By exposing telnet on the Internet, remote root access on the device is possible. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
The Telnet service of Rubetek cameras RV-3406, RV-3409, and RV-3411 cameras (firmware versions v342, v339) could allow an remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password. The Telnet service cannot be disabled and this password cannot be changed via standard functionality.
The ZyXEL P660HN-T1A v2 TCLinux Fw #7.3.37.6 router distributed by TrueOnline has three user accounts with default passwords, including two hardcoded service accounts: one with the username true and password true, and another with the username supervisor and password zyad1234. These accounts can be used to login to the web interface, exploit authenticated command injections, and change router settings for malicious purposes.
The presence of a hardcoded account in Fortinet FortiWLC 8.3.3 allows attackers to gain unauthorized read/write access via a remote shell.
Zivif PR115-204-P-RS V2.3.4.2103 web cameras contain a hard-coded cat1029 password for the root user. The SONIX operating system's setup renders this password unchangeable and it can be used to access the device via a TELNET session.
D-Link D-View InstallApplication Use of Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of D-Link D-View. Authentication is not required to exploit this vulnerability. The specific flaw exists within the InstallApplication class. The class contains a hard-coded password for the remotely reachable database. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-19553.
The presence of a hardcoded account in Fortinet FortiWLC 7.0.11 and earlier allows attackers to gain unauthorized read/write access via a remote shell.
The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device.
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The Dropbear SSH daemon has been modified to accept an alternate hard-coded path to a public key that allows root access. This key is stored in a /rom location that cannot be modified by the device owner.
The factory configuration for vMX installations, as shipped, includes default credentials for the root account. Without proper modification of these default credentials by the administrator, an attacker could exploit these credentials and access the vMX instance without authorization. This issue affects Juniper Networks Junos OS: 17.1 versions prior to 17.1R2-S11, 17.1R3-S2 on vMX; 17.2 versions prior to 17.2R3-S3 on vMX; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on vMX; 17.4 versions prior to 17.4R2-S9, 17.4R3 on vMX; 18.1 versions prior to 18.1R3-S9 on vMX; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3 on vMX; 18.2X75 versions prior to 18.2X75-D420, 18.2X75-D60 on vMX; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1 on vMX; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on vMX; 19.1 versions prior to 19.1R1-S4, 19.1R2, 19.1R3 on vMX; 19.2 versions prior to 19.2R1-S3, 19.2R2 on vMX; 19.3 versions prior to 19.3R1-S1, 19.3R2 on vMX.
IZON IP 2.0.2: hard-coded password vulnerability
ASUSTOR ADM 3.1.0.RFQ3 uses the same default root:admin username and password as it does for the NAS itself for applications that are installed from the online repository. This may allow an attacker to login and upload a webshell.
Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution.
GateManager versions prior to 9.2c, The affected product contains a hard-coded credential for telnet, allowing an unprivileged attacker to execute commands as root.
Grandstream GXV3501, GXV3504, GXV3601, GXV3601HD/LL, GXV3611HD/LL, GXV3615W/P, GXV3651FHD, GXV3662HD, GXV3615WP_HD, GXV3500, and possibly other camera models with firmware 1.0.4.11, have a hardcoded account "!#/" with the same password, which makes it easier for remote attackers to obtain access via a TELNET session.
A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials.
Directus 6.4.9 has a hardcoded admin password for the Admin account because of an INSERT statement in api/schema.sql.
Green Packet DX-350 Firmware version v2.8.9.5-g1.4.8-atheeb has a default password of admin for the admin account.
Arbitrary code execution vlnerability in Operation bridge Manager, Application Performance Management and Operations Bridge (containerized) vulnerability in Micro Focus products products Operation Bridge Manager, Operation Bridge (containerized) and Application Performance Management. The vulneravility affects: 1.) Operation Bridge Manager versions 2020.05, 2019.11, 2019.05, 2018.11, 2018.05, 10.63,10.62, 10.61, 10.60, 10.12, 10.11, 10.10 and all earlier versions. 2.) Operations Bridge (containerized) 2020.05, 2019.08, 2019.05, 2018.11, 2018.08, 2018.05. 2018.02 and 2017.11. 3.) Application Performance Management versions 9,51, 9.50 and 9.40 with uCMDB 10.33 CUP 3. The vulnerability could allow Arbitrary code execution.
An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account.
A vulnerability in the Cluster Manager of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to log in to an affected system using the root account, which has default, static user credentials. The vulnerability is due to the presence of undocumented, static user credentials for the root account. An attacker could exploit this vulnerability by using the account to log in to an affected system. An exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user. Cisco Bug IDs: CSCvh02680.
ECOA BAS controller is vulnerable to hard-coded credentials within its Linux distribution image, thus remote attackers can obtain administrator’s privilege without logging in.
Softing FG-100 PB PROFIBUS firmware version FG-x00-PB_V2.02.0.00 contains a hardcoded password for the root account, which allows remote attackers to obtain administrative access via a TELNET session.
Juniper Networks Contrail Service Orchestration releases prior to 3.3.0 have Cassandra service enabled by default with hardcoded credentials. These credentials allow network based attackers unauthorized access to information stored in Cassandra.
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI.
D-Link DGS-1500 Ax devices before 2.51B021 have a hardcoded password, which allows remote attackers to obtain shell access.
OpsRamp Gateway before 7.0.0 has a backdoor account vadmin with the password 9vt@f3Vt that allows root SSH access to the server. This issue has been resolved in OpsRamp Gateway firmware version 7.0.0 where an administrator and a system user accounts are the only available user accounts for the gateway appliance.
The National Payments Corporation of India BHIM application 1.3 for Android relies on three hardcoded strings (AK-NPCIMB, IM-NPCIBM, and VK-NPCIBM) for SMS validation, which makes it easier for attackers to bypass authentication.
Wireless IP Camera (P2P) WIFICAM devices have a backdoor root account that can be accessed with TELNET.
The SMI-S service in Dell Storage Manager versions earlier than 16.3.20 (aka 2016 R3.20) is protected using a hard-coded password. A remote user with the knowledge of the password might potentially disable the SMI-S service via HTTP requests, affecting storage management and monitoring functionality via the SMI-S interface. This issue, aka DSM-30415, only affects a Windows installation of the Data Collector (not applicable to the virtual appliance).
Amcrest IPM-721S V2.420.AC00.16.R.20160909 devices have default credentials that are hardcoded in the firmware and can be extracted by anyone who reverses the firmware to identify them. If the firmware version V2.420.AC00.16.R 9/9/2016 is dissected using binwalk tool, one obtains a _user-x.squashfs.img.extracted archive which contains the filesystem set up on the device that many of the binaries in the /usr folder. The binary "sonia" is the one that has the vulnerable function that sets up the default credentials on the device. If one opens this binary in IDA-pro, one will notice that this follows a ARM little endian format. The function sub_3DB2FC in IDA pro is identified to be setting up the values at address 0x003DB5A6. The sub_5C057C then sets this value and adds it to the Configuration files in /mnt/mtd/Config/Account1 file.
An authentication bypass was found in an unknown area of the SiteOmat source code. All SiteOmat BOS versions are affected, prior to the submission of this exploit. Also, the SiteOmat does not force administrators to switch passwords, leaving SSH and HTTP remote authentication open to public.
D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices have a hardcoded password of wrgac25_dlink.2013gui_dir850l for the Alphanetworks account upon device reset, which allows remote attackers to obtain root access via a TELNET session.
The Carlo Gavazzi EOS-Box stores hard-coded passwords in the PHP file of the device. By using the hard-coded passwords, attackers can log into the device with administrative privileges. This could allow the attacker to have unauthorized access.
An issue was discovered in Polycom Web Management Interface G3/HDX 8000 HD with Durango 2.6.0 4740 software and embedded Polycom Linux Development Platform 2.14.g3. It has a blank administrative password by default, and can be successfully used without setting this password.
A Use of Hard-coded Cryptographic Key issue was discovered in Korenix JetNet JetNet5018G version 1.4, JetNet5310G version 1.4a, JetNet5428G-2G-2FX version 1.4, JetNet5628G-R version 1.4, JetNet5628G version 1.4, JetNet5728G-24P version 1.4, JetNet5828G version 1.1d, JetNet6710G-HVDC version 1.1e, and JetNet6710G version 1.1. An attacker may gain access to hard-coded certificates and private keys allowing the attacker to perform man-in-the-middle attacks.
GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
A vulnerability in the key-based SSH authentication mechanism of Cisco Policy Suite could allow an unauthenticated, remote attacker to log in to an affected system as the root user. This vulnerability is due to the re-use of static SSH keys across installations. An attacker could exploit this vulnerability by extracting a key from a system under their control. A successful exploit could allow the attacker to log in to an affected system as the root user.
EMV DiskXtender 6.20.060 has a hard-coded login and password, which allows remote attackers to bypass authentication via the RPC interface.
The Epson "EasyMP" software is designed to remotely stream a users computer to supporting projectors.These devices are authenticated using a unique 4-digit code, displayed on-screen - ensuring only those who can view it are streaming.In addition to the password, each projector has a hardcoded "backdoor" code (2270), which authenticates to all devices.
A hard-coded password of tecn0visi0n for the dlxuser account in TecnoVISION DLX Spot Player4 (all known versions) allows remote attackers to log in via SSH and escalate privileges to root access with the same credentials.
GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
An authentication bypass vulnerability exists in the device password generation functionality of Swift Sensors Gateway SG3-1010. A specially-crafted network request can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.
A Hardcoded JWT Secret Key in metadata.py in AdaptiveScale LXDUI through 2.1.3 allows attackers to gain admin access to the host system.
The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password.
The Data Warehouse component in NetApp OnCommand Insight before 7.2.3 allows remote attackers to obtain administrative access by leveraging a default privileged account.
An issue was discovered on Wireless IP Camera 360 devices. Remote attackers can discover a weakly encoded admin password by connecting to TCP port 9527 and reading the password field of the debugging information, e.g., nTBCS19C corresponds to a password of 123456.
An issue was discovered in Veritas NetBackup Before 8.0 and NetBackup Appliance Before 3.0. NetBackup Cloud Storage Service uses a hardcoded username and password.
An issue was discovered on PLANEX CS-W50HD devices with firmware before 030720. A hardcoded credential "supervisor:dangerous" was injected into web authentication database "/.htpasswd" during booting process, which allows attackers to gain unauthorized access and control the device completely; the account can't be modified or deleted.