An issue was discovered in TRENDnet TEW-827DRU firmware before 2.05B11. There is a command injection in apply.cgi (exploitable with authentication) via the TCP Ports To Open in Add Gaming Rule.
An issue was discovered in TRENDnet TEW-827DRU firmware before 2.05B11. There is a command injection in apply.cgi (exploitable with authentication) via the UDP Ports To Open in Add Gaming Rule.
An issue was discovered in TRENDnet TEW-827DRU firmware before 2.05B11. There is a command injection in apply.cgi (exploitable with authentication) via the action set_sta_enrollee_pin_5g and the key wps_sta_enrollee_pin.
TRENDnet TEW-827DRU with firmware up to and including 2.04B03 contains a stack-based buffer overflow while returning an error message to the user about failure to resolve a hostname during a ping or traceroute attempt. This allows an authenticated user to execute arbitrary code. The exploit can be exercised on the local intranet or remotely if remote administration is enabled.
An issue was discovered in TRENDnet TEW-827DRU firmware before 2.05B11. There is a command injection in apply.cgi (exploitable with authentication) via the IP Address in Add Gaming Rule.
An issue was discovered in TRENDnet TEW-827DRU firmware before 2.05B11. There is a command injection in apply.cgi (exploitable with authentication) via the IP Address in Add Virtual Server.
A security vulnerability has been detected in TRENDnet TEW-800MB 1.0.1.0. Affected is the function do_setWizard_asp of the file /goform/wizardset of the component Management Interface. The manipulation of the argument WizardConfigured leads to command injection. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered in TRENDnet TEW-827DRU firmware before 2.05B11. There is a command injection in apply.cgi (exploitable with authentication) via the Private Port in Add Virtual Server.
An issue was discovered in TRENDnet TEW-827DRU firmware before 2.05B11. There is a command injection in apply.cgi (exploitable with authentication). The command injection exists in the key ip_addr.
A vulnerability was detected in TRENDnet TEW-800MB 1.0.1.0. Affected by this vulnerability is the function sub_F934Ā of the file NTPSyncWithHost.cgi. The manipulation results in command injection. The attack may be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered in TRENDnet TEW-827DRU firmware before 2.05B11. There is a command injection in apply.cgi (exploitable with authentication) via the key passwd in Routing RIP Settings.
TRENDnet TEW-673GRU v1.00b40 devices have an OS command injection vulnerability in the start_arpping function of the timer binary, which allows remote attackers to execute arbitrary commands via three parameters (dhcpd_start, dhcpd_end, and lan_ipaddr) passed to the apply.cgi binary through a POST request.
Buffer overflow in apply.cgi on TRENDnet TEW-632BRP 1.010B32 and TEW-673GRU devices allows attackers to hijack the control flow to any attacker-specified location by crafting a POST request payload (with authentication).
Trendnet AC2600 TEW-827DRU version 2.08B01 is vulnerable to command injection. The system log functionality of the firmware allows for command injection as root by supplying a malformed parameter.
A security vulnerability has been detected in TRENDnet TEW-821DAP 1.12B01. Impacted is the function auto_update_firmware of the component Firmware Udpate. The manipulation of the argument str leads to buffer overflow. The attack may be initiated remotely. The vendor explains: "That firmware version will only work on our hardware version v1.xR. We have already EOL that product 8 years ago and are no longer selling". This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability, which was classified as critical, has been found in TRENDnet TEW-652BRP 3.04B01. This issue affects some unknown processing of the file get_set.ccp of the component Web Management Interface. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-219935.
A security flaw has been discovered in Trendnet TEW-657BRM 1.00.1. The impacted element is the function update_pcdb of the file /setup.cgi. The manipulation of the argument mac_pc_dba results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor confirms, that "[t]he product in question (...) has been discontinued and end of life since June 23, 2011, that is more than 14 years ago. We no longer provide support for this product, so we are not able to confirm the vulnerabilities. We will make an announcement on our website's product support page and notify customers who registered their products with us." This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was identified in Trendnet TEW-657BRM 1.00.1. The affected element is the function add_apcdb of the file /setup.cgi. The manipulation of the argument mac_pc_dba leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used. The vendor confirms, that "[t]he product in question (...) has been discontinued and end of life since June 23, 2011, that is more than 14 years ago. We no longer provide support for this product, so we are not able to confirm the vulnerabilities. We will make an announcement on our website's product support page and notify customers who registered their products with us." This vulnerability only affects products that are no longer supported by the maintainer.
An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the date parameter in a system_time.cgi POST request. TRENDnet TEW-632BRP 1.010B32 is also affected.
A vulnerability was determined in TRENDnet TEW-432BRP 3.10B20. Affected by this vulnerability is the function formSetRoute of the file /goform/formSetRoute. This manipulation of the argument ip/mask/gateway causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized. The vendor explains: "This product has been EOL for 15 years (since 2009). As the item has been EOL for such a long time, we are not able to replicate or fix any vulnerabilities." This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was identified in TRENDnet TEW-432BRP 3.10B20. Affected by this issue is the function formWPS of the file /goform/formWPS. Such manipulation of the argument peerPin leads to stack-based buffer overflow. The attack may be performed from remote. The exploit is publicly available and might be used. The vendor explains: "This product has been EOL for 15 years (since 2009). As the item has been EOL for such a long time, we are not able to replicate or fix any vulnerabilities." This vulnerability only affects products that are no longer supported by the maintainer.
Trendnet AC2600 TEW-827DRU version 2.08B01 contains a command injection vulnerability in the smb functionality of the device. The username parameter used when configuring smb functionality for the device is vulnerable to command injection as root.
TRENDnet TEW-827DRU devices through 2.06B04 contain multiple command injections in apply.cgi via the action send_log_email with the key auth_acname (or auth_passwd), allowing an authenticated user to run arbitrary commands on the device.
TRENDnet TEW-827DRU devices through 2.06B04 contain multiple command injections in apply.cgi via the action pppoe_connect, ru_pppoe_connect, or dhcp_connect with the key wan_ifname (or wan0_dns), allowing an authenticated user to run arbitrary commands on the device.
An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the wps_sta_enrollee_pin parameter in a set_sta_enrollee_pin.cgi POST request. TRENDnet TEW-632BRP 1.010B32 is also affected.
An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the dns_query_name parameter in a dns_query.cgi POST request. TRENDnet TEW-632BRP 1.010B32 is also affected.
A vulnerability was found in TRENDnet TEW-815DAP 1.0.2.0. It has been classified as critical. This affects the function do_setNTP of the component POST Request Handler. The manipulation of the argument NtpDstStart/NtpDstEnd leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252123. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
TRENDnet TEW-751DR v1.03B03, TEW-752DRU v1.03B01, and TEW733GR v1.03B01 devices allow authentication bypass via an AUTHORIZED_GROUP=1 value, as demonstrated by a request for getcfg.php.
An access control issue in TrendNet TV-IP572PI v1.0 allows unauthenticated attackers to access sensitive system information.
Trendnet AC2600 TEW-827DRU version 2.08B01 does not have sufficient protections for the UART functionality. A malicious actor with physical access to the device is able to connect to the UART port via a serial connection. No username or password is required and the user is given a root shell with full control of the device.
The ping tool in multiple D-Link and TRENDnet devices allow remote attackers to execute arbitrary code via the ping_addr parameter to ping.ccp.
Undocumented TELNET service in TRENDnet TEW-691GR and TEW-692GR when a web page named backdoor contains an HTML parameter of password and a value of j78G¬DFdg_24Mhw3.
Trendnet TEW733GR v1.03B01 contains a Static Default Credential vulnerability in /etc/init0.d/S80telnetd.sh.
TRENDnet TS-S402 has a backdoor to enable TELNET.
Cisco RV110W, RV130W, and RV215W devices have an incorrect RBAC configuration for the default account, which allows remote authenticated users to obtain root access via a login session with that account, aka Bug IDs CSCuv90139, CSCux58175, and CSCux73557.
Unspecified vulnerability in Sun Integrated Lights-Out Manager (ILOM) 2.0.1.5 through 2.0.4.26 allows remote authenticated users to (1) access the service processor (SP) and cause a denial of service (shutdown or reboot), or (2) access the host operating system and have an unspecified impact, via unknown vectors.
SOOTEWAY Wi-Fi Range Extender v1.5 was discovered to use default credentials (the admin password for the admin account) to access the TELNET service, allowing attackers to erase/read/write the firmware remotely.
The LDAP over SSL (aka LDAPS) implementation in Active Directory, Active Directory Application Mode (ADAM), and Active Directory Lightweight Directory Service (AD LDS) in Microsoft Windows XP SP2 and SP3, Windows Server 2003 SP2, Windows Vista SP2, Windows Server 2008 SP2, R2, and R2 SP1, and Windows 7 Gold and SP1 does not examine Certificate Revocation Lists (CRLs), which allows remote authenticated users to bypass intended certificate restrictions and access Active Directory resources by leveraging a revoked X.509 certificate for a domain account, aka "LDAPS Authentication Bypass Vulnerability."
Jenkins versions 2.56 and earlier as well as 2.46.1 LTS and earlier are vulnerable to a login command which allowed impersonating any Jenkins user. The `login` command available in the remoting-based CLI stored the encrypted user name of the successfully authenticated user in a cache file used to authenticate further commands. Users with sufficient permission to create secrets in Jenkins, and download their encrypted values (e.g. with Job/Configure permission), were able to impersonate any other Jenkins user on the same instance.
Datalogic AV7000 Linear barcode scanner all versions prior to 4.6.0.0 is vulnerable to authentication bypass, which may allow an attacker to remotely execute arbitrary code.
There is an authentication bypass vulnerability in some Huawei servers. A remote attacker with low privilege may bypass the authentication by some special operations. Due to insufficient authentication, an attacker may exploit the vulnerability to get some sensitive information and high-level users' privilege.
West Wind Web Server 6.x does not require authentication for /ADMIN.ASP.
A vulnerability has been identified in TeleControl Server Basic < V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations.
NordVPN 3.3.10 for macOS suffers from a root privilege escalation vulnerability. The vulnerability stems from its privileged helper tool's implemented XPC service. This XPC service is responsible for receiving and processing new OpenVPN connection requests from the main application. Unfortunately this XPC service is not protected, which allows arbitrary applications to connect and send it XPC messages. An attacker can send a crafted XPC message to the privileged helper tool requesting it make a new OpenVPN connection. Because he or she controls the contents of the XPC message, the attacker can specify the location of the openvpn executable, which could point to something malicious they control located on disk. Without validation of the openvpn executable, this will give the attacker code execution in the context of the privileged helper tool.
An issue was discovered in PrinterOn Central Print Services (CPS) through 4.1.4. A user without valid credentials can bypass the authentication process, obtaining a valid session cookie with guest/pseudo-guest level privileges. This cookie can then be further used to perform other attacks.
IBM Security QRadar SIEM 7.2 and 7.3 could allow a user to bypass authentication which could lead to code execution. IBM X-Force ID: 138824.
In firmware version MS_2.6.9900 of Columbia Weather MicroServer, an authenticated web user can access an alternative configuration page config_main.php that allows manipulation of the device.
The HomeAutomationGateway service in MiCasaVerde VeraLite with firmware 1.5.408 allows (1) remote attackers to execute arbitrary Lua code via a RunLua action in a request to upnp/control/hag on port 49451 or (2) remote authenticated users to execute arbitrary Lua code via a RunLua action in a request to port_49451/upnp/control/hag.
In Apache Zeppelin prior to 0.8.0 the cron scheduler was enabled by default and could allow users to run paragraphs as other users without authentication.
glusterfs server before versions 3.10.12, 4.0.2 is vulnerable when using 'auth.allow' option which allows any unauthenticated gluster client to connect from any network to mount gluster storage volumes. NOTE: this vulnerability exists because of a CVE-2018-1088 regression.