BMC BladeLogic Server Automation (BSA) before 8.7 Patch 3 allows remote attackers to bypass authentication and consequently read arbitrary files or possibly have unspecified other impact by leveraging a "logic flaw" in the authentication process.
In multiple Tecson Tankspion and GOKs SmartBox 4 products the affected application doesn't properly restrict access to an endpoint that is responsible for saving settings, to a unauthenticated user with limited access rights. Based on the lack of adequately implemented access-control rules, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to change the application settings without authenticating at all, which violates originally laid ACL rules.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled from the WBM. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
A business logic issue in the MStore API WordPress plugin, versions before 3.2.0, had an authentication bypass with Sign In With Apple allowing unauthenticated users to recover an authentication cookie with only an email address.
Incorrect access control was discovered in the stdonato Dashboard plugin through 0.9.7 for GLPI, affecting df.php, issue.php, load.php, mem.php, traf.php, and uptime.php in front/sh.
In DouCo DouPHP v1.5 Release 20190516, remote attackers can view the database backup file via a brute-force guessing approach for data/backup/DyyyymmddThhmmss.sql filenames.
The Java Glassfish Admin Console in HP Executive Scorecard 9.40 and 9.41 does not require authentication, which allows remote attackers to execute arbitrary code via a session on TCP port 10001, aka ZDI-CAN-2116.
Unify OpenStage/OpenScape Desk Phone IP SIP before V3 R3.11.0 has an authentication bypass in the default mode of the Workpoint Interface
HP Support Assistant before 8.1.52.1 allows remote attackers to bypass authentication via unspecified vectors.
When using the CAS Proxy ticket authentication from Spring Security 3.1 to 3.2.4 a malicious CAS Service could trick another CAS Service into authenticating a proxy ticket that was not associated. This is due to the fact that the proxy ticket authentication uses the information from the HttpServletRequest which is populated based upon untrusted information within the HTTP request. This means if there are access control restrictions on which CAS services can authenticate to one another, those restrictions can be bypassed. If users are not using CAS Proxy tickets and not basing access control decisions based upon the CAS Service, then there is no impact to users.
Contao 4.7 allows Use of a Key Past its Expiration Date.
An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
Schrack Technik microControl with firmware before 1.7.0 (937) stores sensitive information under the web root with insufficient access control, which allows remote attackers to obtain access data for the ftp and telnet services via a direct request for ZTPUsrDtls.txt.
TIBCO Enterprise Administrator 1.0.0 and Enterprise Administrator SDK 1.0.0 do not properly enforce administrative authentication requirements, which allows remote attackers to execute arbitrary commands via unspecified vectors.
The administrative interface in Allied Telesis AT-RG634A ADSL Broadband router 3.3+, iMG624A firmware 3.5, iMG616LH firmware 2.4, and iMG646BD firmware 3.5 allows remote attackers to gain privileges and execute arbitrary commands via a direct request to cli.html.
The wp-support-plus-responsive-ticket-system plugin before 4.2 for WordPress has incorrect authentication.
Aztech ADSL DSL5018EN (1T1R), DSL705E, and DSL705EU devices improperly manage sessions, which allows remote attackers to bypass authentication in opportunistic circumstances and execute arbitrary commands with administrator privileges by leveraging an existing web portal login.
Netsweeper before 4.0.5 allows remote attackers to bypass authentication and create arbitrary accounts and policies via a request to webadmin/nslam/index.php.
Remote command execution due to use of default passwords. The following products are affected: Acronis Cyber Infrastructure (ACI) before build 5.0.1-61, Acronis Cyber Infrastructure (ACI) before build 5.1.1-71, Acronis Cyber Infrastructure (ACI) before build 5.2.1-69, Acronis Cyber Infrastructure (ACI) before build 5.3.1-53, Acronis Cyber Infrastructure (ACI) before build 5.4.4-132.
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. An attacker can bypass the required authentication specified in the security configuration file by including extra characters in the directory name when specifying the directory to be accessed. This vulnerability does not affect the i.LON 600 product.
A remote code execution issue was discovered in the WooCommerce Products Filter (aka WOOF) plugin before 2.2.0 for WordPress, as demonstrated by the shortcode parameter in a woof_redraw_woof action. The plugin implemented a page redraw AJAX function accessible to anyone without any authentication. WordPress shortcode markup in the "shortcode" parameters would be evaluated. Normally unauthenticated users can't evaluate shortcodes as they are often sensitive.
Unauthentication vulnerabilities have been identified in Geutebruck G-Cam/EFD-2250 Version 1.12.0.4 and Topline TopFD-2125 Version 3.15.1 IP cameras, which may allow remote code execution.
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.
The management web interface on the Nisuta NS-WIR150NE router with firmware 5.07.41 and Nisuta NS-WIR300N router with firmware 5.07.36_NIS01 allows remote attackers to bypass authentication via a "Cookie: :language=en" HTTP header.
Ice Cold Apps Servers Ultimate 6.0.2(12) does not require authentication for TELNET, SSH, or FTP, which allows remote attackers to execute arbitrary code by uploading PHP scripts.
A remote code execution vulnerability was identified in HPE Intelligent Management Center (iMC) prior to iMC PLAT 7.3 E0605P04.
It was discovered that the Unitrends Backup (UB) before 10.1.0 user interface was exposed to an authentication bypass, which then could allow an unauthenticated user to inject arbitrary commands into its /api/hosts parameters using backquotes.
West Wind Web Server 6.x does not require authentication for /ADMIN.ASP.
Raritan PX before 1.5.11 on DPXR20A-16 devices allows remote attackers to bypass authentication and execute arbitrary IPMI commands by using cipher suite 0 (aka cipher zero) and an arbitrary password.
Cisco Linksys Routers EA2700, EA3500, E4200, EA4500: A bug can cause an unsafe TCP port to open which leads to unauthenticated access
The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attackers to perform administrative actions via requests to the management interface.
A command execution vulnerability in SonicWall GMS 9.3 allows a remote unauthenticated attacker to locally escalate privilege to root.
A vulnerability has been identified in TIM 1531 IRC (All versions < V1.1). A remote attacker with network access to port 80/tcp or port 443/tcp could perform administrative operations on the device without prior authentication. Successful exploitation could allow to cause a denial-of-service, or read and manipulate data as well as configuration settings of the affected device. At the stage of publishing this security advisory no public exploitation is known. Siemens provides mitigations to resolve it.
The HP Integrated Lights-Out (iLO) BMC implementation allows remote attackers to bypass authentication and execute arbitrary IPMI commands by using cipher suite 0 (aka cipher zero) and an arbitrary password.
Improper authentication of Non-EAPOL/WAPI plaintext frames during four-way handshake can lead to arbitrary network packet injection in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Consumer Electronics Connectivity, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Voice & Music
The Adaptive Security Device Management (ASDM) remote-management feature in Cisco Adaptive Security Appliance (ASA) Software 8.2.x before 8.2(5.46), 8.3.x before 8.3(2.39), 8.4.x before 8.4(6), 8.5.x before 8.5(1.18), 8.6.x before 8.6(1.12), 8.7.x before 8.7(1.7), 9.0.x before 9.0(3.1), and 9.1.x before 9.1(2.6) does not properly implement the authentication-certificate option, which allows remote attackers to bypass authentication via a TCP session to an ASDM interface, aka Bug ID CSCuh44815.
A vulnerability in the web-based management interface of Cisco UCS Director and Cisco UCS Director Express for Big Data could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrator privileges on an affected system. The vulnerability is due to improper authentication request handling. An attacker could exploit this vulnerability by sending crafted HTTP requests to an affected device. A successful exploit could allow an unprivileged attacker to access and execute arbitrary actions through certain APIs.
The firmware on GateHouse; Harris BGAN RF-7800B-VU204 and BGAN RF-7800B-DU204; Hughes Network Systems 9201, 9450, and 9502; Inmarsat; Japan Radio JUE-250 and JUE-500; and Thuraya IP satellite terminals does not require authentication for sessions on TCP port 1827, which allows remote attackers to execute arbitrary code via unspecified protocol operations.
The Dell iDRAC6 with firmware 1.x before 1.92 and 2.x and 3.x before 3.42, and iDRAC7 with firmware before 1.23.23, allows remote attackers to bypass authentication and execute arbitrary IPMI commands by using cipher suite 0 (aka cipher zero) and an arbitrary password. NOTE: the vendor disputes the significance of this issue, stating "DRAC's are intended to be on a separate management network; they are not designed nor intended to be placed on or connected to the Internet."
The Supermicro BMC implementation allows remote attackers to bypass authentication and execute arbitrary IPMI commands by using cipher suite 0 (aka cipher zero) and an arbitrary password.
Netgear WNR1000v3 with firmware before 1.0.2.60 contains an Authentication Bypass via the NtgrBak key.
Novell iManager 2.7 before SP6 Patch 1 does not refresh a token after a logout action, which has unspecified impact and remote attack vectors.
An Authentication Bypass vulnerability in Belkin N300 (F7D7301v1) router allows remote attackers to bypass authentication using "Javascript debugging."
The Sierra Wireless AirLink Raven X EV-DO gateway 4221_4.0.11.003 and 4228_4.0.11.003 allows remote attackers to reprogram the firmware via a replay attack using UDP ports 17336 and 17388.
The check_login function in D-Link DNR-326 before 2.10 build 03 allows remote attackers to bypass authentication and log in by setting the username cookie parameter to an arbitrary string.
A default username and password in Dentsply Sirona Sidexis 4.3.1 and earlier allows an attacker to gain administrative access to the application server.
The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
Sitefinity 5.1, 5.2, 5.3, 5.4, 6.x, 7.x, 8.x, 9.x, and 10.x allow remote attackers to bypass authentication and consequently cause a denial of service on load balanced sites or gain privileges via vectors related to weak cryptography.
The web server in Novell ZENworks Configuration Management (ZCM) 10.3 and 11.2 before 11.2.4 does not properly perform authentication for zenworks/jsp/index.jsp, which allows remote attackers to conduct directory traversal attacks, and consequently upload and execute arbitrary programs, via a request to TCP port 443.
Condor before 7.8.2 allows remote attackers to bypass host-based authentication and execute actions such as ALLOW_ADMINISTRATOR or ALLOW_WRITE by connecting from a system with a spoofed reverse DNS hostname.