Vulnerability Details :

CVE-2012-6437

Summary
Assigner-icscert
Assigner Org ID-7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At-24 Jan, 2013 | 21:00
Updated At-30 Jun, 2025 | 22:05
Rejected At-
Credits

Rockwell Automation ControlLogix PLC Improper Authentication

The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:icscert
Assigner Org ID:7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At:24 Jan, 2013 | 21:00
Updated At:30 Jun, 2025 | 22:05
Rejected At:
▼CVE Numbering Authority (CNA)
Rockwell Automation ControlLogix PLC Improper Authentication

The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400

Affected Products
Vendor
Rockwell Automation, Inc.Rockwell Automation
Product
1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules
Default Status
unaffected
Versions
Affected
  • All
Vendor
Rockwell Automation, Inc.Rockwell Automation
Product
CompactLogix L32E and L35E controllers
Default Status
unaffected
Versions
Affected
  • All
Vendor
Rockwell Automation, Inc.Rockwell Automation
Product
1788-ENBT FLEXLogix adapter
Default Status
unaffected
Versions
Affected
  • All
Vendor
Rockwell Automation, Inc.Rockwell Automation
Product
1794-AENTR FLEX I/O EtherNet/IP adapter
Default Status
unaffected
Versions
Affected
  • All
Vendor
Rockwell Automation, Inc.Rockwell Automation
Product
ControlLogix, CompactLogix, GuardLogix, and SoftLogix
Default Status
unaffected
Versions
Affected
  • From 0 through 18 (custom)
Vendor
Rockwell Automation, Inc.Rockwell Automation
Product
CompactLogix and SoftLogix controllers
Default Status
unaffected
Versions
Affected
  • From 0 through 19 (custom)
Vendor
Rockwell Automation, Inc.Rockwell Automation
Product
ControlLogix and GuardLogix controllers
Default Status
unaffected
Versions
Affected
  • From 0 through 20 (custom)
Vendor
Rockwell Automation, Inc.Rockwell Automation
Product
MicroLogix
Default Status
unaffected
Versions
Affected
  • 1100
  • 1400
Problem Types
TypeCWE IDDescription
CWECWE-287CWE-287
Type: CWE
CWE ID: CWE-287
Description: CWE-287
Metrics
VersionBase scoreBase severityVector
2.010.0N/A
AV:N/AC:L/Au:N/C:C/I:C/A:C
Version: 2.0
Base score: 10.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:N/C:C/I:C/A:C
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

According to Rockwell, any of the above products that become affected by a vulnerability can be reset by rebooting or power cycling the affected product. After the reboot, the affected product may require some reconfiguration. To mitigate the vulnerabilities, Rockwell has developed and released security patches on July 18, 2012, to address each of the issues. To download and install the patches please refer to Rockwell’s Advisories at: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154 https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155 https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156 For more information on security with Rockwell Automation products, please refer to Rockwell’s Security Advisory Index http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102 .

Configurations

Workarounds

Rockwell recommends updating to the newest firmware patches to fix the vulnerabilities, but if not able to do so right away, then Rockwell advises immediately employing the following mitigations for each of the affected products. To mitigate the vulnerability with the Web server password authentication mechanism: * Upgrade the MicroLogix 1400 firmware to FRN 12 or higher. * Because of limitations in the MicroLogix 1100 platform, none of the firmware updates will be able to fix this issue, so users should use the following techniques to help reduce the likelihood of compromise. * Where possible, disable the Web server and change all default Administrator and Guest passwords. * If Web server functionality is needed, then Rockwell recommends upgrading the product’s firmware to the most current version to have the newest enhanced protections available such as: * When a controller receives two consecutive invalid authentication requests from an HTTP client, the controller resets the Authentication Counter after 60 minutes. * When a controller receives 10 invalid authentication requests from any HTTP client, it will not accept any valid or invalid authentication packets until a 24-hour HTTP Server Lock Timer timeout. * If Web server functionality is needed, Rockwell also recommends configuring user accounts to have READ only access to the product so those accounts cannot be used to make configuration change In addition to the above, Rockwell recommends concerned customers remain vigilant and continue to follow security strategies that help reduce risk and enhance overall control system security. Where possible, they suggest you apply multiple recommendations and complement this list with your own best-practices: * Employ layered security and defense-in-depth methods in system design to restrict and control access to individual products and control networks. Refer to http://www.ab.com/networks/architectures.html for comprehensive information about implementing validated architectures designed to deliver these measures. * Restrict physical and electronic access to automation products, networks, and systems to only those individuals authorized to be in contact with control system equipment. * Employ firewalls with ingress/egress filtering, intrusion detection/prevention systems, and validate all configurations. Evaluate firewall configurations to ensure other appropriate inbound and outbound traffic is blocked. * Use up-to-date end-point protection software (e.g., antivirus/antimalware software) on all PC-based assets. * Make sure that software and control system device firmware is patched to current releases. * Periodically change passwords in control system components and infrastructure devices. * Where applicable, set the controller key-switch/mode-switch to RUN mode. For more information on security with Rockwell Automation products, please refer to Rockwell’s Security Advisory Index http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102 .

Exploits

Credits

finder
Rubén Santamarta of IOActive identified vulnerabilities in Rockwell Automation’s ControlLogix PLC and released proof-of-concept (exploit) code at the Digital Bond S4 Conference on January 19, 2012.
Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03
N/A
https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154
N/A
https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155
N/A
https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156
N/A
http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102
N/A
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03
Resource: N/A
Hyperlink: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154
Resource: N/A
Hyperlink: https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155
Resource: N/A
Hyperlink: https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156
Resource: N/A
Hyperlink: http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102
Resource: N/A
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://www.us-cert.gov/control_systems/pdf/ICSA-13-011-03.pdf
x_refsource_MISC
x_transferred
Hyperlink: http://www.us-cert.gov/control_systems/pdf/ICSA-13-011-03.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:ics-cert@hq.dhs.gov
Published At:24 Jan, 2013 | 21:55
Updated At:30 Jun, 2025 | 22:15

The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary2.010.0HIGH
AV:N/AC:L/Au:N/C:C/I:C/A:C
Primary2.010.0HIGH
AV:N/AC:L/Au:N/C:C/I:C/A:C
Type: Secondary
Version: 2.0
Base score: 10.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:C/I:C/A:C
Type: Primary
Version: 2.0
Base score: 10.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:C/I:C/A:C
CPE Matches

Rockwell Automation, Inc.
rockwellautomation
>>controllogix_controllers>>Versions up to 20(inclusive)
cpe:2.3:a:rockwellautomation:controllogix_controllers:*:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>guardlogix_controllers>>Versions up to 20(inclusive)
cpe:2.3:a:rockwellautomation:guardlogix_controllers:*:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>micrologix>>Versions up to 1100(inclusive)
cpe:2.3:a:rockwellautomation:micrologix:*:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>micrologix>>Versions up to 1400(inclusive)
cpe:2.3:a:rockwellautomation:micrologix:*:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>softlogix_controllers>>Versions up to 19(inclusive)
cpe:2.3:a:rockwellautomation:softlogix_controllers:*:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>1756-enbt>>-
cpe:2.3:h:rockwellautomation:1756-enbt:-:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>1756-eweb>>-
cpe:2.3:h:rockwellautomation:1756-eweb:-:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>1768-enbt>>-
cpe:2.3:h:rockwellautomation:1768-enbt:-:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>1768-eweb>>-
cpe:2.3:h:rockwellautomation:1768-eweb:-:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>1794-aentr_flex_i\/o_ethernet\/ip_adapter>>-
cpe:2.3:h:rockwellautomation:1794-aentr_flex_i\/o_ethernet\/ip_adapter:-:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>compactlogix>>Versions up to 18(inclusive)
cpe:2.3:h:rockwellautomation:compactlogix:*:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>compactlogix_controllers>>Versions up to 19(inclusive)
cpe:2.3:h:rockwellautomation:compactlogix_controllers:*:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>compactlogix_l32e_controller>>-
cpe:2.3:h:rockwellautomation:compactlogix_l32e_controller:-:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>compactlogix_l35e_controller>>-
cpe:2.3:h:rockwellautomation:compactlogix_l35e_controller:-:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>controllogix>>Versions up to 18(inclusive)
cpe:2.3:h:rockwellautomation:controllogix:*:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>flexlogix_1788-enbt_adapter>>-
cpe:2.3:h:rockwellautomation:flexlogix_1788-enbt_adapter:-:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>guardlogix>>Versions up to 18(inclusive)
cpe:2.3:h:rockwellautomation:guardlogix:*:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>softlogix>>Versions up to 18(inclusive)
cpe:2.3:h:rockwellautomation:softlogix:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-287Primaryics-cert@hq.dhs.gov
CWE-287Secondarynvd@nist.gov
CWE ID: CWE-287
Type: Primary
Source: ics-cert@hq.dhs.gov
CWE ID: CWE-287
Type: Secondary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102ics-cert@hq.dhs.gov
N/A
https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154ics-cert@hq.dhs.gov
N/A
https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155ics-cert@hq.dhs.gov
N/A
https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156ics-cert@hq.dhs.gov
N/A
https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03ics-cert@hq.dhs.gov
N/A
http://www.us-cert.gov/control_systems/pdf/ICSA-13-011-03.pdfaf854a3a-2127-422b-91ae-364da2661108
US Government Resource
Hyperlink: http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102
Source: ics-cert@hq.dhs.gov
Resource: N/A
Hyperlink: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154
Source: ics-cert@hq.dhs.gov
Resource: N/A
Hyperlink: https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155
Source: ics-cert@hq.dhs.gov
Resource: N/A
Hyperlink: https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156
Source: ics-cert@hq.dhs.gov
Resource: N/A
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03
Source: ics-cert@hq.dhs.gov
Resource: N/A
Hyperlink: http://www.us-cert.gov/control_systems/pdf/ICSA-13-011-03.pdf
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
US Government Resource

Change History

0
Information is not available yet

Similar CVEs

242Records found

CVE-2012-4715
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-0.34% / 56.21%
||
7 Day CHG~0.00%
Published-18 Apr, 2013 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via a UDP packet with a certain integer length value that is (1) too large or (2) too small, leading to improper handling by Logger.dll.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-rslinx_enterprisen/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2010-2965
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-92.24% / 99.71%
||
7 Day CHG~0.00%
Published-04 Aug, 2010 | 21:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The WDB target agent debug service in Wind River VxWorks 6.x, 5.x, and earlier, as used on the Rockwell Automation 1756-ENBT series A with firmware 3.2.6 and 3.6.1 and other products, allows remote attackers to read or modify arbitrary memory locations, perform function calls, or manage tasks via requests to UDP port 17185, a related issue to CVE-2005-3804.

Action-Not Available
Vendor-windrivern/aRockwell Automation, Inc.
Product-1756-enbt\/a_firmware1756-enbt\/avxworksn/a
CWE ID-CWE-863
Incorrect Authorization
CVE-2009-3739
Matching Score-8
Assigner-CERT/CC
ShareView Details
Matching Score-8
Assigner-CERT/CC
CVSS Score-10||HIGH
EPSS-0.06% / 18.30%
||
7 Day CHG~0.00%
Published-19 Jan, 2010 | 16:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple unspecified vulnerabilities on the Rockwell Automation AB Micrologix 1100 and 1400 controllers allow remote attackers to obtain privileged access or cause a denial of service (halt) via unknown vectors.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-ab_micrologix_controller_1100ab_micrologix_controller_1400n/a
CVE-2019-10970
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.03% / 8.51%
||
7 Day CHG~0.00%
Published-11 Jul, 2019 | 19:51
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Rockwell Automation PanelView 5510 (all versions manufactured before March 13, 2019 that have never been updated to v4.003, v5.002, or later), a remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and gain root-level access to the device’s file system.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-panelview_5510panelview_5510_firmwareRockwell Automation PanelView 5510
CWE ID-CWE-284
Improper Access Control
CVE-2020-6967
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-1.58% / 80.86%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 20:16
Updated-04 Aug, 2024 | 09:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-factorytalk_services_platformRockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2016-0868
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.21% / 43.20%
||
7 Day CHG~0.00%
Published-28 Jan, 2016 | 21:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow on Rockwell Automation Allen-Bradley MicroLogix 1100 devices A through 15.000 and B before 15.002 allows remote attackers to execute arbitrary code via a crafted web request.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-1763-l16dwd_series_b1763-l16bbb_series_b1763-l16awa_series_a1763-l16bwa_series_b1763-l16dwd_series_a1763-l16bwa_series_a1763-l16bbb_series_a1763-l16awa_series_bab_micrologix_controllern/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2015-6490
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-0.92% / 74.95%
||
7 Day CHG~0.00%
Published-28 Oct, 2015 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices through B FRN 15.003 allows remote attackers to execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-micrologix_1400_firmwaremicrologix_1100_firmwaren/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-19282
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.40% / 59.63%
||
7 Day CHG~0.00%
Published-04 Apr, 2019 | 20:31
Updated-05 Aug, 2024 | 11:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to cause a denial of service by crashing the Common Industrial Protocol (CIP) network stack. The vulnerability allows the attacker to crash the CIP in a way that it does not accept new connections, but keeps the current connections active, which can prevent legitimate users from recovering control.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-powerflex_525_ac_drivespowerflex_525_ac_drives_firmwaren/a
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2020-6990
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.11% / 29.86%
||
7 Day CHG~0.00%
Published-16 Mar, 2020 | 15:39
Updated-04 Aug, 2024 | 09:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-micrologix_1400_a_firmwaremicrologix_1100rslogix_500micrologix_1100_firmwaremicrologix_1400micrologix_1400_b_firmwareRockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior
CWE ID-CWE-321
Use of Hard-coded Cryptographic Key
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2023-46290
Matching Score-6
Assigner-Rockwell Automation
ShareView Details
Matching Score-6
Assigner-Rockwell Automation
CVSS Score-8.1||HIGH
EPSS-0.24% / 46.24%
||
7 Day CHG~0.00%
Published-27 Oct, 2023 | 18:10
Updated-27 Feb, 2025 | 20:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation FactoryTalk Services Platform Elevated Privileges Vulnerability

Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into FactoryTalk® Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk® Services Platform web service.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-factorytalk_services_platformFactoryTalk® Services Platform
CWE ID-CWE-287
Improper Authentication
CVE-2012-6440
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.3||HIGH
EPSS-1.17% / 77.77%
||
7 Day CHG~0.00%
Published-24 Jan, 2013 | 21:00
Updated-30 Jun, 2025 | 22:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation ControlLogix PLC Improper Input Validation

The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-micrologixcompactlogix_l35e_controllercompactlogix_l32e_controllersoftlogix_controllerssoftlogix1794-aentr_flex_i\/o_ethernet\/ip_adaptercontrollogix_controllersguardlogix1768-ewebcompactlogix_controllerscontrollogixguardlogix_controllerscompactlogixflexlogix_1788-enbt_adapter1768-enbt1756-eweb1756-enbt1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modulesCompactLogix and SoftLogix controllers1788-ENBT FLEXLogix adapterControlLogix and GuardLogix controllersControlLogix, CompactLogix, GuardLogix, and SoftLogixCompactLogix L32E and L35E controllers1794-AENTR FLEX I/O EtherNet/IP adapterMicroLogix
CWE ID-CWE-287
Improper Authentication
CVE-2024-37368
Matching Score-6
Assigner-Rockwell Automation
ShareView Details
Matching Score-6
Assigner-Rockwell Automation
CVSS Score-8.2||HIGH
EPSS-0.11% / 30.56%
||
7 Day CHG~0.00%
Published-14 Jun, 2024 | 14:30
Updated-31 Jan, 2025 | 15:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation FactoryTalk® View SE v11 Information Leakage Vulnerability via Authentication Restriction

A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. Due to the lack of proper authentication, this action is allowed without proper authentication verification.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-factorytalk_viewFactoryTalk® View SEfactorytalk_view
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2024-37367
Matching Score-6
Assigner-Rockwell Automation
ShareView Details
Matching Score-6
Assigner-Rockwell Automation
CVSS Score-8.2||HIGH
EPSS-0.06% / 20.06%
||
7 Day CHG~0.00%
Published-14 Jun, 2024 | 14:17
Updated-16 Aug, 2024 | 19:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation FactoryTalk® View SE v12 Information Leakage Vulnerability via Authentication Restriction

A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper authentication verification.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-factorytalk_viewFactoryTalk® View SE
CWE ID-CWE-287
Improper Authentication
CVE-2023-29463
Matching Score-6
Assigner-Rockwell Automation
ShareView Details
Matching Score-6
Assigner-Rockwell Automation
CVSS Score-8.8||HIGH
EPSS-0.03% / 5.46%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 16:42
Updated-27 Feb, 2025 | 20:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Pavilion8 Security Misconfiguration Vulnerability

The JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-pavilion8Pavilion8
CWE ID-CWE-287
Improper Authentication
CVE-2018-19616
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.1||HIGH
EPSS-4.71% / 88.95%
||
7 Day CHG~0.00%
Published-26 Dec, 2018 | 20:00
Updated-05 Aug, 2024 | 11:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-powermonitor_1000powermonitor_1000_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2020-6988
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.13% / 33.58%
||
7 Day CHG~0.00%
Published-16 Mar, 2020 | 15:38
Updated-04 Aug, 2024 | 09:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-micrologix_1400_a_firmwaremicrologix_1100rslogix_500micrologix_1100_firmwaremicrologix_1400micrologix_1400_b_firmwareRockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior
CWE ID-CWE-603
Use of Client-Side Authentication
CWE ID-CWE-287
Improper Authentication
CVE-2018-0163
Matching Score-6
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-6
Assigner-Cisco Systems, Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.25% / 48.25%
||
7 Day CHG~0.00%
Published-28 Mar, 2018 | 22:00
Updated-02 Dec, 2024 | 20:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the 802.1x multiple-authentication (multi-auth) feature of Cisco IOS Software could allow an unauthenticated, adjacent attacker to bypass the authentication phase on an 802.1x multi-auth port. The vulnerability is due to a logic change error introduced into the code. An attacker could exploit this vulnerability by trying to access an 802.1x multi-auth port after a successful supplicant has authenticated. An exploit could allow the attacker to bypass the 802.1x access controls and obtain access to the network. Cisco Bug IDs: CSCvg69701.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.Cisco Systems, Inc.
Product-5921_embedded_services_router819_hardened_3g1905_serial_integrated_services_router887vagw_3g1240_connected_grid_routerc867vae_integrated_services_router886va-w_integrated_services_router860vae-w_integrated_services_routerc891f_integrated_services_routersc896va_integrated_services_router5940_embedded_services_router1921_integrated_services_routerc897vam-w_integrated_services_router886va_integrated_services_routerstratix_59001906c_integrated_services_router2010_connected_grid_router819_non-hardened_secure_multi-mode_4g_lte_m2m_isr_router892w_integrated_services_routerc881_integrated_services_routerc866vae_integrated_services_router809_industrial_integrated_services_router5915_embedded_service_routerc887vam_integrated_services_routersc887va_integrated_services_routers898_secure_g.shdsl_efm\/atmc888ea_integrated_services_router812_cifi_integrated_services_router886vag_3g_integrated_services_routerc899_secure_gigabit_ethernet888eg_3g_integrated_services_router881_3g_integrated_services_router2921_integrated_services_router888w_integrated_services_router897_multi-mode_vdsl2\/adsl2\+_pots_annex_m3925_integrated_services_routervg350_analog_voice_gatewayc886vaj_integrated_services_router2951_integrated_services_router888-cube_integrated_services_routervg204xm_analog_voice_gateway819_hardened_integrated_services_router887vam-w_integrated_services_router3925e_integrated_services_router887vamg_3g_integrated_services_router861_integrated_services_router812_3g_integrated_services_routerc897va_integrated_services_routerc892fsp_integrated_services_router887va_integrated_services_router886va-cube_integrated_services_routerc886va_integrated_services_routers2911_integrated_services_routerc891fw_integrated_services_router866vae_integrated_services_router891w_integrated_services_routerc898ea_integrated_services_router800_series_routers888e-cube_integrated_services_router1941_integrated_services_router880-voice_integrated_services_router819_hardened_dual_radio_802.11n_wifi_integrated_services_router897_multi-mode_vdsl2\/adsl2\+_potsios1941w_integrated_services_router3945e_integrated_services_routerc897va-m_integrated_services_router887vag_3g_integrated_services_router819_integrated_services_router892_integrated_services_router887va-cube_integrated_services_router887va-w_integrated_services_router819_non-hardened_4g_lte_m2m3945_integrated_services_router881-cube_integrated_services_router881_3g800m_integrated_services_router881_secure_fast_ethernet891_integrated_services_router896_multi-mode_vdsl2\/adsl2\+_isdnc881w_integrated_services_router1120_connected_grid_router891-24x_integrated_services_router888_integrated_services_router2901_integrated_services_router892f-cube_integrated_services_router888e_integrated_services_router2911a_integrated_services_router861w_integrated_services_routerc888_integrated_services_router829_industrial_integrated_services_router867vae_integrated_services_routerc897vaw_integrated_services_router887_multi-mode_vdsl2\/asdl2\+_potsvg3x0_analog_voice_gateway881w_integrated_services_routerCisco IOS
CWE ID-CWE-287
Improper Authentication
CVE-2022-3156
Matching Score-6
Assigner-Rockwell Automation
ShareView Details
Matching Score-6
Assigner-Rockwell Automation
CVSS Score-7.8||HIGH
EPSS-0.07% / 22.89%
||
7 Day CHG~0.00%
Published-27 Dec, 2022 | 18:17
Updated-10 Apr, 2025 | 20:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation Studio 5000 Logix Emulate Vulnerable to a Remote Code Execution Vulnerability

A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software.  Users are granted elevated permissions on certain product services when the software is installed. Due to this misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-studio_5000_logix_emulateStudio 5000 Logix Emulate
CWE ID-CWE-287
Improper Authentication
CVE-2020-14504
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.3||MEDIUM
EPSS-0.23% / 45.68%
||
7 Day CHG~0.00%
Published-24 Feb, 2022 | 18:26
Updated-17 Apr, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-1734-aentr_point_i\/o_dual_port_network_adaptor_series_b1734-aentr_point_i\/o_dual_port_network_adaptor_series_c_firmware1734-aentr_point_i\/o_dual_port_network_adaptor_series_b_firmware1734-aentr_point_i\/o_dual_port_network_adaptor_series_c1734-AENTR
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-287
Improper Authentication
CVE-2024-6078
Matching Score-6
Assigner-Rockwell Automation
ShareView Details
Matching Score-6
Assigner-Rockwell Automation
CVSS Score-8.6||HIGH
EPSS-0.11% / 30.55%
||
7 Day CHG~0.00%
Published-14 Aug, 2024 | 19:45
Updated-19 Aug, 2024 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation Authentication Bypass Vulnerability in DataMosaix™

CVE-2024-6078 IMPACT An improper authentication vulnerability exists in the affected product, which could allow a malicious user to generate cookies for any user ID without the use of a username or password. If exploited, a malicious user could take over the account of a legitimate user. The malicious user would be able to view and modify data stored in the cloud.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-DataMosaix™datamosaix
CWE ID-CWE-287
Improper Authentication
CVE-2022-38744
Matching Score-6
Assigner-Rockwell Automation
ShareView Details
Matching Score-6
Assigner-Rockwell Automation
CVSS Score-7.5||HIGH
EPSS-0.15% / 35.60%
||
7 Day CHG+0.02%
Published-27 Oct, 2022 | 13:25
Updated-05 May, 2025 | 15:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
FactoryTalk Alarm and Events Server Vulnerable to Denial-Of-Service Attack

An unauthenticated attacker with network access to a victim's Rockwell Automation FactoryTalk Alarm and Events service could open a connection, causing the service to fault and become unavailable. The affected port could be used as a server ping port and uses messages structured with XML.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-factorytalk_alarms_and_eventsFactoryTalk Alarm and Events Server
CWE ID-CWE-287
Improper Authentication
CVE-2023-2638
Matching Score-6
Assigner-Rockwell Automation
ShareView Details
Matching Score-6
Assigner-Rockwell Automation
CVSS Score-5.9||MEDIUM
EPSS-0.00% / 0.11%
||
7 Day CHG~0.00%
Published-13 Jun, 2023 | 20:25
Updated-02 Jan, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation FactoryTalk System Services Vulnerable to a Denial-of-Service Attack

Rockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected.   Improper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives.  This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-factorytalk_policy_managerfactorytalk_system_servicesFactoryTalk System Services
CWE ID-CWE-287
Improper Authentication
CVE-2024-45823
Matching Score-6
Assigner-Rockwell Automation
ShareView Details
Matching Score-6
Assigner-Rockwell Automation
CVSS Score-9.2||CRITICAL
EPSS-0.10% / 27.69%
||
7 Day CHG~0.00%
Published-12 Sep, 2024 | 14:20
Updated-02 Oct, 2024 | 14:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
FactoryTalk® Batch View™ Authentication Bypass Vulnerability via shared secrets

CVE-2024-45823 IMPACT An authentication bypass vulnerability exists in the affected product. The vulnerability exists due to shared secrets across accounts and could allow a threat actor to impersonate a user if the threat actor is able to enumerate additional information required during authentication.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-factorytalk_batch_viewFactoryTalk® Batch View™factorytalk_batch_view
CWE ID-CWE-287
Improper Authentication
CVE-2013-6035
Matching Score-4
Assigner-CERT/CC
ShareView Details
Matching Score-4
Assigner-CERT/CC
CVSS Score-10||HIGH
EPSS-1.71% / 81.59%
||
7 Day CHG~0.00%
Published-04 Feb, 2014 | 02:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The firmware on GateHouse; Harris BGAN RF-7800B-VU204 and BGAN RF-7800B-DU204; Hughes Network Systems 9201, 9450, and 9502; Inmarsat; Japan Radio JUE-250 and JUE-500; and Thuraya IP satellite terminals does not require authentication for sessions on TCP port 1827, which allows remote attackers to execute arbitrary code via unspecified protocol operations.

Action-Not Available
Vendor-hughes_network_systemsjapan_radioinmarsatgatehouseharristhuraya_telecommunicationsn/a
Product-94509201jue-250bgan9502inmarsatjue-500ipgatehousen/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-9542
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.16% / 83.60%
||
7 Day CHG~0.00%
Published-11 Jun, 2017 | 23:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-615 Wireless N 300 Router allows authentication bypass via a modified POST request to login.cgi. This issue occurs because it fails to validate the password field. Successful exploitation of this issue allows an attacker to take control of the affected device.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-615dir-615_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-7588
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-30.89% / 96.57%
||
7 Day CHG~0.00%
Published-12 Apr, 2017 | 10:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On certain Brother devices, authorization is mishandled by including a valid AuthCookie cookie in the HTTP response to a failed login attempt. Affected models are: MFC-J6973CDW MFC-J4420DW MFC-8710DW MFC-J4620DW MFC-L8850CDW MFC-J3720 MFC-J6520DW MFC-L2740DW MFC-J5910DW MFC-J6920DW MFC-L2700DW MFC-9130CW MFC-9330CDW MFC-9340CDW MFC-J5620DW MFC-J6720DW MFC-L8600CDW MFC-L9550CDW MFC-L2720DW DCP-L2540DW DCP-L2520DW HL-3140CW HL-3170CDW HL-3180CDW HL-L8350CDW HL-L2380DW ADS-2500W ADS-1000W ADS-1500W.

Action-Not Available
Vendor-n/aBrother Industries, Ltd.
Product-mfc-j5910dwmfc-j6973cdwmfc-l8850cdwmfc-j6920dwads-1500wads_firmwaremfc-j6720dwmfc_firmwaremfc-l2740dwmfc-8710dwdcp-l2520dwhl-l8350cdwmfc-9130cwhl-3170cdwmfc-l2700dwads-2500wdcp-l2540dwmfc-l8600cdwmfc-l9550cdwads-1000wmfc-j6520dwmfc-l2720dwhl-l2380dwmfc-9340cdwmfc-j4620dwmfc-j5620dwhl-3140cwmfc-9330cdwmfc-j4420dwhl_firmwaremfc-j3720hl-3180cdwdcp_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-7450
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.33% / 55.10%
||
7 Day CHG~0.00%
Published-05 Apr, 2017 | 23:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

AIRTAME HDMI dongle with firmware before 2.2.0 allows unauthenticated access to a big part of the management interface. It is possible to extract all information including the Wi-Fi password, reboot, or force a software update at an arbitrary time.

Action-Not Available
Vendor-airtamen/a
Product-hdmi_donglehdmi_dongle_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-5944
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-1.49% / 80.25%
||
7 Day CHG~0.00%
Published-03 Oct, 2013 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attackers to perform administrative actions via requests to the management interface.

Action-Not Available
Vendor-n/aSiemens AG
Product-scalance_x-200scalance_x-200irtscalance_x-200_series_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-7649
Matching Score-4
Assigner-Eclipse Foundation
ShareView Details
Matching Score-4
Assigner-Eclipse Foundation
CVSS Score-9.8||CRITICAL
EPSS-0.37% / 58.17%
||
7 Day CHG~0.00%
Published-11 Sep, 2017 | 16:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The network enabled distribution of Kura before 2.1.0 takes control over the device's firewall setup but does not allow IPv6 firewall rules to be configured. Still the Equinox console port 5002 is left open, allowing to log into Kura without any user credentials over unencrypted telnet and executing commands using the Equinox "exec" command. As the process is running as "root" full control over the device can be acquired. IPv6 is also left in auto-configuration mode, accepting router advertisements automatically and assigns a MAC address based IPv6 address.

Action-Not Available
Vendor-Eclipse Foundation AISBL
Product-kuraEclipse Kura Installer
CWE ID-CWE-287
Improper Authentication
CVE-2017-8023
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-9.8||CRITICAL
EPSS-17.99% / 94.90%
||
7 Day CHG~0.00%
Published-01 Apr, 2019 | 20:54
Updated-16 Sep, 2024 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EMC Networker Remote Code Execution Vulnerability

EMC NetWorker may potentially be vulnerable to an unauthenticated remote code execution vulnerability in the Networker Client execution service (nsrexecd) when oldauth authentication method is used. An unauthenticated remote attacker could send arbitrary commands via RPC service to be executed on the host system with the privileges of the nsrexecd service, which runs with administrative privileges.

Action-Not Available
Vendor-Dell Inc.
Product-emc_networkerNetworker
CWE ID-CWE-287
Improper Authentication
CVE-2019-5909
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-9.8||CRITICAL
EPSS-11.71% / 93.42%
||
7 Day CHG~0.00%
Published-13 Feb, 2019 | 18:00
Updated-04 Aug, 2024 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

License Manager Service of YOKOGAWA products (CENTUM VP (R5.01.00 - R6.06.00), CENTUM VP Entry Class (R5.01.00 - R6.06.00), ProSafe-RS (R3.01.00 - R4.04.00), PRM (R4.01.00 - R4.02.00), B/M9000 VP(R7.01.01 - R8.02.03)) allows remote attackers to bypass access restriction to send malicious files to the PC where License Manager Service runs via unspecified vectors.

Action-Not Available
Vendor-yokogawaYokogawa Electric Corporation
Product-prmb\/m_9000_vpprosafe-rscentum_vpLicense Manager Service of YOKOGAWA products
CWE ID-CWE-287
Improper Authentication
CVE-2017-6526
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-83.73% / 99.25%
||
7 Day CHG~0.00%
Published-09 Mar, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in dnaTools dnaLIMS 4-2015s13. dnaLIMS is vulnerable to unauthenticated command execution through an improperly protected administrative web shell (cgi-bin/dna/sysAdmin.cgi POST requests).

Action-Not Available
Vendor-dnatoolsn/a
Product-dnalimsn/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-5511
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-10||HIGH
EPSS-1.84% / 82.20%
||
7 Day CHG~0.00%
Published-13 Oct, 2013 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Adaptive Security Device Management (ASDM) remote-management feature in Cisco Adaptive Security Appliance (ASA) Software 8.2.x before 8.2(5.46), 8.3.x before 8.3(2.39), 8.4.x before 8.4(6), 8.5.x before 8.5(1.18), 8.6.x before 8.6(1.12), 8.7.x before 8.7(1.7), 9.0.x before 9.0(3.1), and 9.1.x before 9.1(2.6) does not properly implement the authentication-certificate option, which allows remote attackers to bypass authentication via a TCP session to an ASDM interface, aka Bug ID CSCuh44815.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-adaptive_security_appliance_softwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-3791
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-10||CRITICAL
EPSS-15.66% / 94.44%
||
7 Day CHG~0.00%
Published-01 Feb, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the web-based GUI of Cisco Prime Home could allow an unauthenticated, remote attacker to bypass authentication and execute actions with administrator privileges. The vulnerability is due to a processing error in the role-based access control (RBAC) of URLs. An attacker could exploit this vulnerability by sending API commands via HTTP to a particular URL without prior authentication. An exploit could allow the attacker to perform any actions in Cisco Prime Home with administrator privileges. This vulnerability affects Cisco Prime Home versions from 6.3.0.0 to the first fixed release 6.5.0.1. Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability. Cisco Bug IDs: CSCvb49837.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-cisco_prime_homeCisco Prime Home versions from 6.3.0.0 to the first fixed release 6.5.0.1
CWE ID-CWE-287
Improper Authentication
CVE-2006-6997
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-0.40% / 59.61%
||
7 Day CHG~0.00%
Published-12 Feb, 2007 | 11:00
Updated-17 Sep, 2024 | 02:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Unspecified vulnerability in a cryptographic feature in MailEnable Standard Edition before 1.93, Professional Edition before 1.73, and Enterprise Edition before 1.21 leads to "weakened authentication security" with unknown impact and attack vectors. NOTE: due to lack of details, it is not clear whether this is the same as CVE-2006-1792.

Action-Not Available
Vendor-mailenablen/a
Product-mailenable_enterprisemailenable_standardn/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-3831
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-9.8||CRITICAL
EPSS-6.12% / 90.42%
||
7 Day CHG~0.00%
Published-15 Mar, 2017 | 20:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the web-based GUI of Cisco Mobility Express 1800 Series Access Points could allow an unauthenticated, remote attacker to bypass authentication. The attacker could be granted full administrator privileges. The vulnerability is due to improper implementation of authentication for accessing certain web pages using the GUI interface. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web interface of the affected system. A successful exploit could allow the attacker to bypass authentication and perform unauthorized configuration changes or issue control commands to the affected device. This vulnerability affects Cisco Mobility Express 1800 Series Access Points running a software version prior to 8.2.110.0. Cisco Bug IDs: CSCuy68219.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-aironet_1815iaironet_1850iaironet_1850eaironet_1830eaironet_access_point_softwareaironet_1810waironet_1830iaironet_1810Cisco Mobility Express 1800 Access Point Series
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-264
Not Available
CVE-2017-2768
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-9.8||CRITICAL
EPSS-2.71% / 85.32%
||
7 Day CHG~0.00%
Published-03 Feb, 2017 | 07:24
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

EMC Network Configuration Manager (NCM) 9.3.x, EMC Network Configuration Manager (NCM) 9.4.0.x, EMC Network Configuration Manager (NCM) 9.4.1.x, EMC Network Configuration Manager (NCM) 9.4.2.x contains an Improper Authentication vulnerability that could potentially be exploited by malicious users to compromise the affected system.

Action-Not Available
Vendor-n/aELAN Microelectronics Corporation
Product-smarts_network_configuration_managerEMC Network Configuration Manager EMC Network Configuration Manager (NCM) 9.3.x, EMC Network Configuration Manager (NCM) 9.4.0.x, EMC Network Configuration Manager (NCM) 9.4.1.x, EMC Network Configuration Manager (NCM) 9.4.2.x
CWE ID-CWE-287
Improper Authentication
CVE-2013-5122
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.11% / 88.14%
||
7 Day CHG~0.00%
Published-07 Jan, 2020 | 13:29
Updated-06 Aug, 2024 | 17:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cisco Linksys Routers EA2700, EA3500, E4200, EA4500: A bug can cause an unsafe TCP port to open which leads to unauthenticated access

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-linksys_e4200_firmwarelinksys_ea4500_firmwarelinksys_ea4500linksys_e4200linksys_ea3500_firmwarelinksys_ea2700linksys_ea3500linksys_ea2700_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2021-42338
Matching Score-4
Assigner-TWCERT/CC
ShareView Details
Matching Score-4
Assigner-TWCERT/CC
CVSS Score-9.8||CRITICAL
EPSS-0.81% / 73.28%
||
7 Day CHG~0.00%
Published-19 Nov, 2021 | 09:05
Updated-17 Sep, 2024 | 00:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
4MOSAn GCB Doctor - Improper Authorization

4MOSAn GCB Doctor’s login page has improper validation of Cookie, which allows an unauthenticated remote attacker to bypass authentication by code injection in cookie, and arbitrarily manipulate the system or interrupt services by upload and execution of arbitrary files.

Action-Not Available
Vendor-4mosan4MOSAn
Product-gcb_doctorGCB Doctor
CWE ID-CWE-285
Improper Authorization
CWE ID-CWE-287
Improper Authentication
CVE-2017-2126
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-9.8||CRITICAL
EPSS-13.46% / 93.94%
||
7 Day CHG~0.00%
Published-22 Jul, 2017 | 00:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

WAPM-1166D firmware Ver.1.2.7 and earlier, WAPM-APG600H firmware Ver.1.16.1 and earlier allows remote attackers to bypass authentication and access the configuration interface via unspecified vectors.

Action-Not Available
Vendor-BUFFALO INC.
Product-wapm-apg600hwapm-apg600h_firmwarewapm-1166d_firmwarewapm-1166dWAPM-APG600HWAPM-1166D
CWE ID-CWE-287
Improper Authentication
CVE-2013-4782
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-60.67% / 98.22%
||
7 Day CHG~0.00%
Published-08 Jul, 2013 | 22:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Supermicro BMC implementation allows remote attackers to bypass authentication and execute arbitrary IPMI commands by using cipher suite 0 (aka cipher zero) and an arbitrary password.

Action-Not Available
Vendor-supermicron/a
Product-bmcn/a
CWE ID-CWE-287
Improper Authentication
CVE-2006-5268
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-18.32% / 94.96%
||
7 Day CHG~0.00%
Published-17 Nov, 2008 | 23:00
Updated-07 Aug, 2024 | 19:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Unspecified vulnerability in Trend Micro ServerProtect 5.7 and 5.58 allows remote attackers to execute arbitrary code via vectors related to obtaining "administrative access to the RPC interface."

Action-Not Available
Vendor-n/aTrend Micro Incorporated
Product-serverprotectn/a
CWE ID-CWE-287
Improper Authentication
CVE-2021-41506
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.99% / 75.98%
||
7 Day CHG~0.00%
Published-30 Jun, 2022 | 12:43
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Xiaongmai AHB7008T-MH-V2, AHB7804R-ELS, AHB7804R-MH-V2, AHB7808R-MS-V2, AHB7808R-MS, AHB7808T-MS-V2, AHB7804R-LMS, HI3518_50H10L_S39 V4.02.R11.7601.Nat.Onvif.20170420, V4.02.R11.Nat.Onvif.20160422, V4.02.R11.7601.Nat.Onvif.20170424, V4.02.R11.Nat.Onvif.20170327, V4.02.R11.Nat.Onvif.20161205, V4.02.R11.Nat.20170301, V4.02.R12.Nat.OnvifS.20170727 is affected by a backdoor in the macGuarder and dvrHelper binaries of DVR/NVR/IP camera firmware due to static root account credentials in the system.

Action-Not Available
Vendor-xiongmaitechn/a
Product-ahb7804r-lms_firmwareahb7804r-mh-v2ahb7008t-mh-v2ahb7804r-mh-v2_firmwareahb7808t-ms-v2ahb7808r-msahb7008t-mh-v2_firmwareahb7808r-ms-v2ahb7804r-lmsahb7808r-ms_firmwarehi3518e_50h10l_s39ahb7804r-elshi3518e_50h10l_s39_firmwareahb7808r-ms-v2_firmwareahb7808t-ms-v2_firmwareahb7804r-els_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-16566
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.33% / 79.16%
||
7 Day CHG~0.00%
Published-17 Nov, 2017 | 23:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On Jooan IP Camera A5 2.3.36 devices, an insecure FTP server does not require authentication, which allows remote attackers to read or replace core system files including those used for authentication (such as passwd and shadow). This can be abused to take full root level control of the device.

Action-Not Available
Vendor-qacctvn/a
Product-jooan_a5_ip_camerajooan_a5_ip_camera_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-3317
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.23% / 45.61%
||
7 Day CHG~0.00%
Published-29 Jan, 2020 | 21:18
Updated-06 Aug, 2024 | 16:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Netgear WNR1000v3 with firmware before 1.0.2.60 contains an Authentication Bypass via the NtgrBak key.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wnr1000_firmwarewnr1000n/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-2820
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-0.01% / 1.35%
||
7 Day CHG~0.00%
Published-15 Jan, 2014 | 16:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Sierra Wireless AirLink Raven X EV-DO gateway 4221_4.0.11.003 and 4228_4.0.11.003 allows remote attackers to reprogram the firmware via a replay attack using UDP ports 17336 and 17388.

Action-Not Available
Vendor-sierrawirelessn/a
Product-raven_x_ev-doraven_x_ev-do_firmwareraven_xairlink_mp_telus_wifiraven_xtairlink_mp_sprintairlink_mp_row_wifiairlink_mp_sprint_wifiairlink_mp_at\&t_wifiairlink_mp_bellairlink_mp_bell_wifiairlink_mp_verizonairlink_mp_rowairlink_mp_telusairlink_mp_at\&tpinpoint_xairlink_mp_verizon_wifipinpoint_xtraven_xen/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-3367
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.51% / 65.46%
||
7 Day CHG~0.00%
Published-13 Nov, 2019 | 20:43
Updated-06 Aug, 2024 | 16:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Undocumented TELNET service in TRENDnet TEW-691GR and TEW-692GR when a web page named backdoor contains an HTML parameter of password and a value of j78G¬DFdg_24Mhw3.

Action-Not Available
Vendor-n/aTRENDnet, Inc.
Product-tew-691grtew-691gr_firmwaretew-692grtew-692gr_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-1405
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-0.90% / 74.74%
||
7 Day CHG~0.00%
Published-15 Feb, 2013 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VMware vCenter Server 4.0 before Update 4b and 4.1 before Update 3a, VMware VirtualCenter 2.5, VMware vSphere Client 4.0 before Update 4b and 4.1 before Update 3a, VMware VI-Client 2.5, VMware ESXi 3.5 through 4.1, and VMware ESX 3.5 through 4.1 do not properly implement the management authentication protocol, which allow remote servers to execute arbitrary code or cause a denial of service (memory corruption) via unspecified vectors.

Action-Not Available
Vendor-n/aVMware (Broadcom Inc.)
Product-esxiesxvcenter_servervsphere_clientvi-clientvirtualcentern/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-1359
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-89.13% / 99.51%
||
7 Day CHG~0.00%
Published-11 Feb, 2020 | 16:42
Updated-06 Aug, 2024 | 14:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Authentication Bypass Vulnerability exists in DELL SonicWALL Analyzer 7.0, Global Management System (GMS) 4.1, 5.0, 5.1, 6.0, and 7.0; Universal Management Appliance (UMA) 5.1, 6.0, and 7.0 and ViewPoint 4.1, 5.0, 5.1, and 6.0 via the skipSessionCheck parameter to the UMA interface (/appliance/), which could let a remote malicious user obtain access to the root account.

Action-Not Available
Vendor-n/aSonicWall Inc.
Product-global_management_systemviewpointuniversal_management_applianceanalyzern/a
CWE ID-CWE-287
Improper Authentication
CVE-2016-9796
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-23.67% / 95.77%
||
7 Day CHG~0.00%
Published-03 Dec, 2016 | 06:28
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Alcatel-Lucent OmniVista 8770 2.0 through 3.0 exposes different ORBs interfaces, which can be queried using the GIOP protocol on TCP port 30024. An attacker can bypass authentication, and OmniVista invokes methods (AddJobSet, AddJob, and ExecuteNow) that can be used to run arbitrary commands on the server, with the privilege of NT AUTHORITY\SYSTEM on the server. NOTE: The discoverer states "The vendor position is to refer to the technical guidelines of the product security deployment to mitigate this issue, which means applying proper firewall rules to prevent unauthorised clients to connect to the OmniVista server."

Action-Not Available
Vendor-n/aAlcatel-Lucent Enterprise (ALE International)
Product-omnivista_8770_network_management_systemn/a
CWE ID-CWE-287
Improper Authentication
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • Next
Details not found