A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions < V2.6.6), SICAM GridEdge Essential Intel (All versions < V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions < V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions < V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to create a new user with administrative permissions.
register_send.php on D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices does not require authentication, which can result in unintended enrollment in mydlink Cloud Services.
The querier component in Grafana Enterprise Logs 1.1.x through 1.3.x before 1.4.0 does not require authentication when X-Scope-OrgID is used. Versions 1.2.1, 1.3.1, and 1.4.0 contain the bugfix. This affects -auth.type=enterprise in microservices mode
An improper authentication vulnerability exists in the REST API functionality of Open Automation Software OAS Platform V16.00.0121. A specially-crafted series of HTTP requests can lead to unauthenticated use of the REST API. An attacker can send a series of HTTP requests to trigger this vulnerability.
A file write vulnerability exists in the OAS Engine SecureTransferFiles functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted series of network requests can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain XML messages to a specific port without proper authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to read and modify the affected product’s configuration.
The SiteGround Security plugin for WordPress is vulnerable to authentication bypass that allows unauthenticated users to log in as administrative users due to missing identity verification on the 2FA back-up code implementation that logs users in upon success. This affects versions up to, and including, 1.2.5.
A vulnerability was found in SAP Information System 1.0 which has been rated as critical. Affected by this issue is the file /SAP_Information_System/controllers/add_admin.php. An unauthenticated attacker is able to create a new admin account for the web application with a simple POST request. Exploit details were disclosed.
Multiple Version of TRUMPF TruTops products expose a service function without necessary authentication. Execution of this function may result in unauthorized access to change of data or disruption of the whole service.
The SiteGround Security plugin for WordPress is vulnerable to authentication bypass that allows unauthenticated users to log in as administrative users due to missing identity verification on initial 2FA set-up that allows unauthenticated and unauthorized users to configure 2FA for pending accounts. Upon successful configuration, the attacker is logged in as that user without access to a username/password pair which is the expected first form of authentication. This affects versions up to, and including, 1.2.5.
On F5 BIG-IP 16.1.x versions prior to 16.1.2.2, 15.1.x versions prior to 15.1.5.1, 14.1.x versions prior to 14.1.4.6, 13.1.x versions prior to 13.1.5, and all 12.1.x and 11.6.x versions, undisclosed requests may bypass iControl REST authentication. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges.
https://gitee.com/mingSoft/MCMS MCMS <=5.2.5 is affected by: RCE. The impact is: execute arbitrary code (remote). The attack vector is: ${"freemarker.template.utility.Execute"?new()("calc")}. ¶¶ MCMS has a pre-auth RCE vulnerability through which allows unauthenticated attacker with network access via http to compromise MCMS. Successful attacks of this vulnerability can result in takeover of MCMS.
An issue was discovered in Reprise RLM 14.2. Because /goform/change_password_process does not verify authentication or authorization, an unauthenticated user can change the password of any existing user. This allows an attacker to change the password of any known user, thereby preventing valid users from accessing the system and granting the attacker full access to that user's account.
A vulnerability is in the 'wx.html' page of the WAVLINK AC1200, version WAVLINK-A42W-1.27.6-20180418, which can allow a remote attacker to access this page without any authentication. When an unauthorized user accesses this page directly, it connects to this device as a friend of the device owner.
In Apache APISIX Dashboard before 2.10.1, the Manager API uses two frameworks and introduces framework `droplet` on the basis of framework `gin`, all APIs and authentication middleware are developed based on framework `droplet`, but some API directly use the interface of framework `gin` thus bypassing the authentication.
Zoho ManageEngine ServiceDesk Plus before 11306, ServiceDesk Plus MSP before 10530, and SupportCenter Plus before 11014 are vulnerable to unauthenticated remote code execution. This is related to /RestAPI URLs in a servlet, and ImportTechnicians in the Struts configuration.
Spinnaker is an open source, multi-cloud continuous delivery platform. Spinnaker has improper permissions allowing pipeline creation & execution. This lets an arbitrary user with access to the gate endpoint to create a pipeline and execute it without authentication. If users haven't setup Role-based access control (RBAC) with-in spinnaker, this enables remote execution and access to deploy almost any resources on any account. Patches are available on the latest releases of the supported branches and users are advised to upgrade as soon as possible. Users unable to upgrade should enable RBAC on ALL accounts and applications. This mitigates the ability of a pipeline to affect any accounts. Block application access unless permission are enabled. Users should make sure ALL application creation is restricted via appropriate wildcards.
AriaNg v0.1.0~v1.2.2 is affected by an incorrect access control vulnerability through not authenticating visitors' access rights.
Zoho ManageEngine ServiceDesk Plus before 11302 is vulnerable to authentication bypass that allows a few REST-API URLs without authentication.
The variable import endpoint was not protected by authentication in Airflow >=2.0.0, <2.1.3. This allowed unauthenticated users to hit that endpoint to add/modify Airflow variables used in DAGs, potentially resulting in a denial of service, information disclosure or remote code execution. This issue affects Apache Airflow >=2.0.0, <2.1.3.
The resolution SAML SSO apps for Atlassian products allow a remote attacker to login to a user account when only the username is known (i.e., no other authentication is provided). The fixed versions are for Jira: 3.6.6.1, 4.0.12, 5.0.5; for Confluence 3.6.6, 4.0.12, 5.0.5; for Bitbucket 2.5.9, 3.6.6, 4.0.12, 5.0.5; for Bamboo 2.5.9, 3.6.6, 4.0.12, 5.0.5; and for Fisheye 2.5.9.
Properly formatted POST requests to multiple resources on the HTTP and HTTPS web servers of the Digi PortServer TS 16 Rack device do not require authentication or authentication tokens. This vulnerability could allow an attacker to enable the SNMP service and manipulate the community strings to achieve further control in.
The server permits communication without any authentication procedure, allowing the attacker to initiate a session with the server without providing any form of authentication.
An issue was discovered in Echo ShareCare 8.15.5. It does not perform authentication or authorization checks when accessing a subset of sensitive resources, leading to the ability for unauthenticated users to access pages that are vulnerable to attacks such as SQL injection.
Unauthenticated Arbitrary Options Update vulnerability leading to full website compromise discovered in Image Hover Effects Ultimate (versions <= 9.6.1) WordPress plugin.
WebAccess/NMS (versions prior to 3.0.2) allows an unauthenticated remote user to create a new admin account.
The Micro Air Vehicle Link (MAVLink) protocol presents no authentication mechanism on its version 1.0 (nor authorization) whichs leads to a variety of attacks including identity spoofing, unauthorized access, PITM attacks and more. According to literature, version 2.0 optionally allows for package signing which mitigates this flaw. Another source mentions that MAVLink 2.0 only provides a simple authentication system based on HMAC. This implies that the flying system overall should add the same symmetric key into all devices of network. If not the case, this may cause a security issue, that if one of the devices and its symmetric key are compromised, the whole authentication system is not reliable.
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000.
An issue was discovered on D-Link DIR-878 1.12B01 devices. Because strncpy is misused, there is a stack-based buffer overflow vulnerability that does not require authentication via the HNAP_AUTH HTTP header.
An issue was discovered on Shenzhen Coship WM3300 WiFi Router 5.0.0.55 devices. The password reset functionality of the Wireless SSID doesn't require any type of authentication. By making a POST request to the regx/wireless/wl_security_2G.asp URI, the attacker can change the password of the Wi-FI network.
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.
ONTAP Select Deploy administration utility versions 2.12 & 2.12.1 ship with an HTTP service bound to the network allowing unauthenticated remote attackers to perform administrative actions.
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.
The RSA Identity Governance and Lifecycle and RSA Via Lifecycle and Governance products prior to 7.1.1 P03 contain an Improper Authentication vulnerability. A Java JMX agent running on the remote host is configured with plain text password authentication. An unauthenticated remote attacker can connect to the JMX agent and monitor and manage the Java application.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the HM-Print AddOn through 1.2a installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi and exec1.cgi scripts, which execute TCL script content from an HTTP POST request.
Systematic IRIS WebForms 5.4 and its functionalities can be accessed and used without any form of authentication.
eQ-3 Homematic CCU2 before 2.47.18 and CCU3 before 3.47.18 allow Remote Code Execution by unauthenticated attackers with access to the web interface via an HTTP POST request to certain URLs related to the ReGa core process.
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.
Intesync Solismed 3.3sp has Incorrect Access Control.
An issue was discovered in Squid through 4.7. When handling requests from users, Squid checks its rules to see if the request should be denied. Squid by default comes with rules to block access to the Cache Manager, which serves detailed server information meant for the maintainer. This rule is implemented via url_regex. The handler for url_regex rules URL decodes an incoming request. This allows an attacker to encode their URL to bypass the url_regex check, and gain access to the blocked resource.
Super Micro SuperDoctor 5, when restrictions are not implemented in agent.cfg, allows remote attackers to execute arbitrary commands via NRPE.
Anviz Global M3 Outdoor RFID Access Control executes any command received from any source. No authentication/encryption is done. Attackers can fully interact with the device: for example, send the "open door" command, download the users list (which includes RFID codes and passcodes in cleartext), or update/create users. The same attack can be executed on a local network and over the internet (if the device is exposed on a public IP address).
In ONAP Logging through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
In ONAP OOM through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.