An issue was discovered on Glory RBW-100 devices with firmware ISP-K05-02 7.0.0. A hard-coded username and password were identified that allow a remote attacker to gain admin access to the Front Circle Controller web interface.
The express install, which is the suggested way to install Puppet Enterprise, gives the user a URL at the end of the install to set the admin password. If they do not use that URL, there is an overlooked default password for the admin user. This was resolved in Puppet Enterprise 2019.0.3 and 2018.1.9.
In Bitnami Containers, all Laravel container versions prior to: 6.20.0-debian-10-r107 for Laravel 6, 7.30.1-debian-10-r108 for Laravel 7 and 8.5.11-debian-10-r0 for Laravel 8, the file /tmp/app/.env is generated at the time that the docker image bitnami/laravel was built, and the value of APP_KEY is fixed under certain conditions. This value is crucial for the security of the application and must be randomly generated per Laravel installation. If your application's encryption key is in the hands of a malicious party, that party could craft cookie values using the encryption key and exploit vulnerabilities inherent to PHP object serialization / unserialization, such as calling arbitrary class methods within your application.
The Web-GUI on WAGO Series 750-88x (750-330, 750-352, 750-829, 750-831, 750-852, 750-880, 750-881, 750-882, 750-884, 750-885, 750-889) and Series 750-87x (750-830, 750-849, 750-871, 750-872, 750-873) devices has undocumented service access.
SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.
Datto ALTO and SIRIS devices have a default VNC password.
ICS/StaticPages/AddTestUsers.aspx in Jenzabar JICS (aka Internet Campus Solution) before 2019-02-06 allows remote attackers to create an arbitrary number of accounts with a password of 1234.
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
An issue was discovered on MOBOTIX S14 MX-V4.2.1.61 devices. There is a default password of meinsm for the admin account.
A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.
man-group/dtale version 3.10.0 is vulnerable to an authentication bypass and remote code execution (RCE) due to improper input validation. The vulnerability arises from a hardcoded `SECRET_KEY` in the flask configuration, allowing attackers to forge a session cookie if authentication is enabled. Additionally, the application fails to properly restrict custom filter queries, enabling attackers to execute arbitrary code on the server by bypassing the restriction on the `/update-settings` endpoint, even when `enable_custom_filters` is not enabled. This vulnerability allows attackers to bypass authentication mechanisms and execute remote code on the server.
A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability.
An issue was discovered on VOBOT CLOCK before 0.99.30 devices. An SSH server exists with a hardcoded vobot account that has root access.
A low privileged admin account with a weak default password of admin exists on the Foxconn FEMTO AP-FC4064-T AP_GT_B38_5.8.3lb15-W47 LTE Build 15. In addition, its web management page relies on the existence or values of cookies when performing security-critical operations. One can gain privileges by modifying cookies.
Juniper ATP ships with hard coded credentials in the Cyphort Core instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
Prisma Industriale Checkweigher PrismaWEB 1.21 allows remote attackers to discover the hardcoded prisma password for the prismaweb account by reading user/scripts/login_par.js.
Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
D-Link DVG-N5402SP with firmware W1000CN-00, W1000CN-03, or W2000EN-00 has a default password of root for the root account and tw for the tw account, which makes it easier for remote attackers to obtain administrative access.
Meross MSS110 devices before 1.1.24 contain a TELNET listener providing access for an undocumented admin account with a blank password.
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices have a hardcoded password of admin for the admin account, a hardcoded password of support for the support account, and a hardcoded password of user for the user account.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
An issue was discovered in the MBeans Server in Wowza Streaming Engine before 4.7.1. The file system may be read and written to via JMX using the default JMX credentials (remote code execution may be possible as well).
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as very critical, has been found in D-Link DNS-320L, DNS-325, DNS-327L and DNS-340L up to 20240403. This issue affects some unknown processing of the file /cgi-bin/nas_sharing.cgi of the component HTTP GET Request Handler. The manipulation of the argument user with the input messagebus leads to hard-coded credentials. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-259283. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
A vulnerability in Brocade Network Advisor Version Before 14.3.1 could allow an unauthenticated, remote attacker to log in to the JBoss Administration interface of an affected system using an undocumented user credentials and install additional JEE applications.
In the web server on D-Link DIR-620 devices with a certain customized (by ISP) variant of firmware 1.0.3, 1.0.37, 1.3.1, 1.3.3, 1.3.7, 1.4.0, and 2.0.22, there is a hardcoded password of anonymous for the admin account.
Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
This vulnerability allows remote attackers to bypass authentication on affected installations of Vinchin Backup and Recovery 6.5.0.17561. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the MySQL server. The server uses a hard-coded password for the administrator user. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17139.
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
MASTER IPCAMERA01 3.3.4.2103 devices have a hardcoded password of cat1029 for the root account.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default root126 password for the root account.
Multiple hardcoded credentials in Xsuite 2.x.
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.
iBaby M3S has a password of admin for the backdoor admin account.
A hard-coded password vulnerability exists in the telnet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. Use of a hard-coded root password can lead to arbitrary command execution. An attacker can authenticate with hard-coded credentials to trigger this vulnerability.
Swann SWWHD-INTCAM-HD devices have the twipc root password, leading to FTP access as root. NOTE: all affected customers were migrated by 2020-08-31.
Certain NETGEAR devices are affected by a hardcoded password. This affects D3600 before 1.0.0.76 and D6000 before 1.0.0.76.
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The admin account has a blank password.
IBM Security Identity Governance and Intelligence 5.2 through 5.2.4.1 Virtual Appliance contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 153386.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. There is a hardcoded Ak47@99 password for the factory~ account.
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The CGIProxy.fcgi?cmd=setTelnetSwitch feature is authorized for the root user with a password of toor.
A design flaw in the Trane ComfortLink II SCC firmware version 2.0.2 service allows remote attackers to take complete control of the system.
Gynoii has a password of guest for the backdoor guest account and a password of 12345 for the backdoor admin account.
spaces.htm on multiple D-Link devices (DSL, DIR, DWR) allows remote unauthenticated attackers to discover admin credentials.
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
Lens Peek-a-View has a password of 2601hx for the backdoor admin account, a password of user for the backdoor user account, and a password of guest for the backdoor guest account.
Hardcoded credentials in the Ricoh myPrint application 2.9.2.4 for Windows and 2.2.7 for Android give access to any externally disclosed myPrint WSDL API, as demonstrated by discovering API secrets of related Google cloud printers, encrypted passwords of mail servers, and names of printed files.