Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers' installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The admin account has a blank password.
backupmgt/pre_connect_check.php in Seagate BlackArmor NAS contains a hard-coded password of '!~@##$$%FREDESWWSED' for a backdoor user.
Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.
Deltek Vision 7.x before 7.6 permits the execution of any attacker supplied SQL statement through a custom RPC over HTTP protocol. The Vision system relies on the client binary to enforce security rules and integrity of SQL statements and other content being sent to the server. Client HTTP calls can be manipulated by one of several means to execute arbitrary SQL statements (similar to SQLi) or possibly have unspecified other impact via this custom protocol. To perform these attacks an authenticated session is first required. In some cases client calls are obfuscated by encryption, which can be bypassed due to hard-coded keys and an insecure key rotation protocol. Impacts may include remote code execution in some deployments; however, the vendor states that this cannot occur when the installation documentation is heeded.
Hardcoded credentials in the Ricoh myPrint application 2.9.2.4 for Windows and 2.2.7 for Android give access to any externally disclosed myPrint WSDL API, as demonstrated by discovering API secrets of related Google cloud printers, encrypted passwords of mail servers, and names of printed files.
An issue was discovered on MOBOTIX S14 MX-V4.2.1.61 devices. There is a default password of meinsm for the admin account.
spaces.htm on multiple D-Link devices (DSL, DIR, DWR) allows remote unauthenticated attackers to discover admin credentials.
NUUO CMS all versions 3.1 and prior, The application creates default accounts that have hard-coded passwords, which could allow an attacker to gain privileged access.
IBM Security Guardium 10 and 10.5 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 150022.
Logitech Harmony Hub before version 4.15.206 contained two hard-coded accounts in the XMPP server that gave remote users access to the local API.
The demo feature in Oracle GlassFish Open Source Edition 5.0 has TCP port 7676 open by default with a password of admin for the admin account. This allows remote attackers to obtain potentially sensitive information, perform database operations, or manipulate the demo via a JMX RMI session, aka a "jmx_rmi remote monitoring and control problem." NOTE: this is not an Oracle supported product.
A vulnerability in the Cisco Small Business Switches software could allow an unauthenticated, remote attacker to bypass the user authentication mechanism of an affected device. The vulnerability exists because under specific circumstances, the affected software enables a privileged user account without notifying administrators of the system. An attacker could exploit this vulnerability by using this account to log in to an affected device and execute commands with full admin rights. Cisco has not released software updates that address this vulnerability. This advisory will be updated with fixed software information once fixed software becomes available. There is a workaround to address this vulnerability.
A vulnerability in Cisco Video Surveillance Manager (VSM) Software running on certain Cisco Connected Safety and Security Unified Computing System (UCS) platforms could allow an unauthenticated, remote attacker to log in to an affected system by using the root account, which has default, static user credentials. The vulnerability is due to the presence of undocumented, default, static user credentials for the root account of the affected software on certain systems. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
A vulnerability in the install function of Cisco Prime Collaboration Provisioning (PCP) could allow an unauthenticated, remote attacker to access the administrative web interface using a default hard-coded username and password that are used during install. The vulnerability is due to a hard-coded password that, in some cases, is not replaced with a unique password. A successful exploit could allow the attacker to access the administrative web interface with administrator-level privileges.
The server API in the Anda app relies on hardcoded credentials.
Sollae Serial-Ethernet-Module and Remote-I/O-Device-Server devices have a default password of sollae for the TELNET service.
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
A hard-coded password vulnerability was discovered in vApp Manager which is embedded in Dell EMC Unisphere for VMAX, Dell EMC Solutions Enabler, Dell EMC VASA Virtual Appliances, and Dell EMC VMAX Embedded Management (eManagement): Dell EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.18, Dell EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.21, Dell EMC VASA Virtual Appliance versions prior to 8.4.0.514, and Dell EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier). They contain an undocumented default account (smc) with a hard-coded password that may be used with certain web servlets. A remote attacker with the knowledge of the hard-coded password and the message format may use vulnerable servlets to gain unauthorized access to the system. Note: This account cannot be used to log in via the web user interface.
SV3C L-SERIES HD CAMERA V2.3.4.2103-S50-NTD-B20170508B and V2.3.4.2103-S50-NTD-B20170823B devices have a Hard-coded Password.
Use of Hard-coded Credentials in /var/www/xms/application/controllers/gatherLogs.php in the administrative console in Dialogic PowerMedia XMS through 3.5 allows remote attackers to interact with a web service.
Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
/usr/lib/lua/luci/websys.lua on TP-LINK IPC TL-IPC223(P)-6, TL-IPC323K-D, TL-IPC325(KP)-*, and TL-IPC40A-4 devices has a hardcoded zMiVw8Kw0oxKXL0 password.
Default and unremovable support credentials (user:lutron password:integration) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the HomeWorks QS Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
Allegra Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Allegra. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of a database. The issue results from the use of a hardcoded password. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-22360.
TOTOLINK A3100R V4.1.2cu.5050_B20200504 and V4.1.2cu.5247_B20211129 were discovered to contain a hard coded password for the telnet service stored in the component /web_cste/cgi-bin/product.ini.
A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered on Intelbras NCLOUD 300 1.0 devices. /cgi-bin/ExportSettings.sh, /goform/updateWPS, /goform/RebootSystem, and /goform/vpnBasicSettings do not require authentication. For example, when an HTTP POST request is made to /cgi-bin/ExportSettings.sh, the username, password, and other details are retrieved.
Use of a Hard-coded Cryptographic Key used to protect cookie session data in /var/www/xms/application/config/config.php in the administrative console in Dialogic PowerMedia XMS through 3.5 allows remote attackers to bypass authentication.
Hardcoded admin token in SoundBar apps in Linkplay SDK 1.00 allows remote attackers to gain admin privilege access in linkplay antifactory
TOTOLINK A3100R V4.1.2cu.5050_B20200504 and V4.1.2cu.5247_B20211129 were discovered to contain a hard coded password for root stored in the component /etc/shadow.sample.
Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100 utilizes hard-coded credentials that may allow an attacker to reset passwords for the controller.
Invoxia NVX220 devices allow TELNET access as admin with a default password.
Battelle V2I Hub 2.5.1 contains hard-coded credentials for the administrative account. An attacker could exploit this vulnerability to log in as an admin on any installation and gain unauthorized access to the system.
Proietti Tech srl Planet Time Enterprise 4.2.0.1,4.2.0.0,4.1.0.0,4.0.0.0,3.3.1.0,3.3.0.0 is vulnerable to Remote code execution via the Viewstate parameter.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Quest Foglight Evolve 9.0.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the __service__ user account. The product contains a hard-coded password for this account. An attacker can leverage this vulnerability to execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-9553.
An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15. Hardcoded credentials exist for an unprivileged SSH account with a shell of /bin/false.
Juniper Networks Contrail Service Orchestration releases prior to 4.0.0 have Grafana service enabled by default with hardcoded credentials. These credentials allow network based attackers unauthorized access to information stored in Grafana or exploit other weaknesses or vulnerabilities in Grafana.
TimeTools SC7105 1.0.007, SC9205 1.0.007, SC9705 1.0.007, SR7110 1.0.007, SR9210 1.0.007, SR9750 1.0.007, SR9850 1.0.007, T100 1.0.003, T300 1.0.003, and T550 1.0.003 devices allow remote attackers to bypass authentication by placing t3axs=TiMEtOOlsj7G3xMm52wB in a t3.cgi request, aka a "hardcoded cookie."
A hard-coded password vulnerability exists in the telnet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. Use of a hard-coded root password can lead to arbitrary command execution. An attacker can authenticate with hard-coded credentials to trigger this vulnerability.
Denbun by NEOJAPAN Inc. (Denbun POP version V3.3P R4.0 and earlier, Denbun IMAP version V3.3I R4.0 and earlier) uses hard-coded credentials, which may allow remote attackers to login to the Management page and change the configuration.
A vulnerability in Cisco Digital Network Architecture (DNA) Center could allow an unauthenticated, remote attacker to log in to an affected system by using an administrative account that has default, static user credentials. The vulnerability is due to the presence of undocumented, static user credentials for the default administrative account for the affected software. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands with root privileges. This vulnerability affects all releases of Cisco DNA Center Software prior to Release 1.1.3. Cisco Bug IDs: CSCvh98929.
Juniper Networks Contrail Service Orchestrator versions prior to 4.0.0 use hardcoded cryptographic certificates and keys in some cases, which may allow network based attackers to gain unauthorized access to services.
A vulnerability in Cisco IOS XE Software could allow an unauthenticated, remote attacker to log in to a device running an affected release of Cisco IOS XE Software with the default username and password that are used at initial boot, aka a Static Credential Vulnerability. The vulnerability is due to an undocumented user account with privilege level 15 that has a default username and password. An attacker could exploit this vulnerability by using this account to remotely connect to an affected device. A successful exploit could allow the attacker to log in to the device with privilege level 15 access. This vulnerability affects Cisco devices that are running a vulnerable release of Cisco IOS XE Software Release 16.x. This vulnerability does not affect Cisco IOS XE Software releases prior to Release 16.x. Cisco Bug IDs: CSCve89880.
Juniper Networks Contrail Service Orchestration releases prior to 3.3.0 use hardcoded credentials to access Keystone service. These credentials allow network based attackers unauthorized access to information stored in keystone.
Denbun by NEOJAPAN Inc. (Denbun POP version V3.3P R4.0 and earlier, Denbun IMAP version V3.3I R4.0 and earlier) uses hard-coded credentials, which may allow remote attackers to read/send mail or change the configuration.
Intellian Aptus Web 1.24 has a hardcoded password of 12345678 for the intellian account.
NUUO v03.11.00 was discovered to contain access control issue.
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected