An issue was discovered in Programi Bilanc build 007 release 014 31.01.2020 and possibly below. During the installation, it sets up administrative access by default with the account admin and password 0000. After the installation, users/admins are not prompted to change this password.
IBM SiteProtector Appliance 3.1.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174142.
NETGEAR XR1000 devices before 1.0.0.58 are affected by a hardcoded password.
An attacker without authentication can login with default credentials for privileged users in Eltex ESP-200 firmware version 1.2.0.
D-Link DGS-1500 Ax devices before 2.51B021 have a hardcoded password, which allows remote attackers to obtain shell access.
GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.
MEDHOST Connex contains a hard-coded Mirth Connect admin credential that is used for customer Mirth Connect management access. An attacker with knowledge of the hard-coded credential and the ability to communicate directly with the Mirth Connect management console may be able to intercept sensitive patient information. The admin account password is hard-coded as $K8t1ng throughout the application, and is the same across all installations. Customers do not have the option to change the Mirth Connect admin account password. The Mirth Connect admin account is created during the Connex install. The plaintext account password is hard-coded multiple times in the Connex install and update scripts.
Emerson DeltaV 10.3.1, 11.3, 11.3.1, and 12.3 uses hardcoded credentials for diagnostic services, which allows remote attackers to bypass intended access restrictions via a TCP session, as demonstrated by a session that uses the telnet program.
By default, BMC PATROL Agent through 11.3.01 uses a static encryption key for encrypting/decrypting user credentials sent over the network to managed PATROL Agent services. If an attacker were able to capture this network traffic, they could decrypt these credentials and use them to execute code or escalate privileges on the network.
Optergy Proton/Enterprise devices have Hard-coded Credentials.
SOPlanning before 1.47 has Incorrect Access Control because certain secret key information, and the related authentication algorithm, is public. The key for admin is hardcoded in the installation code, and there is no key for publicsp (which is a guest account).
Use of Hard-coded Credentials vulnerability in FortiRecorder all versions below 2.7.4 may allow an unauthenticated attacker with knowledge of the aforementioned credentials and network access to FortiCameras to take control of those, provided they are managed by a FortiRecorder device.
The Web Panel in Netsweeper before 4.0.5 has a default password of branding for the branding account, which makes it easier for remote attackers to obtain access via a request to webadmin/.
Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-798: Use of Hard-coded Credentials.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge.
IBM Security Guardium Data Encryption (GDE) 3.0.0.2 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 171832.
Hard coded weak credentials in Barracuda Load Balancer 5.0.0.015.
A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way.
The Fedora Nagios package uses "nagiosadmin" as the default password for the "nagiosadmin" administrator account, which makes it easier for remote attackers to obtain access by leveraging knowledge of the credentials.
Multiple hardcoded credentials in Xsuite 2.x.
The installation of Microsoft Exchange 2000 before Rev. A creates a user account with a known password, which could allow attackers to gain privileges, aka the "Exchange User Account" vulnerability.
IBM Security Identity Manager 7.0.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 171511.
FreeSWITCH 1.6.10 through 1.10.1 has a default password in event_socket.conf.xml.
An authentication weakness in the SNMP service in B&R Automation Runtime versions 2.96, 3.00, 3.01, 3.06 to 3.10, 4.00 to 4.63, 4.72 and above allows unauthenticated users to modify the configuration of B&R products via SNMP.
A vulnerability in the web-based management interface of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrative privileges on an affected device. The vulnerability is due to improper session management on affected DCNM software. An attacker could exploit this vulnerability by sending a crafted HTTP request to the affected device. A successful exploit could allow the attacker to gain administrative access on the affected device.
CA Network Flow Analysis 9.x and 10.0.x have a default credential vulnerability that can allow a remote attacker to execute arbitrary commands and compromise system security.
TELESTAR Bobs Rock Radio, Dabman D10, Dabman i30 Stereo, Imperial i110, Imperial i150, Imperial i200, Imperial i200-cd, Imperial i400, Imperial i450, Imperial i500-bt, and Imperial i600 TN81HH96-g102h-g102 devices have insufficient access control for the /set_dname, /mylogo, /LocalPlay, /irdevice.xml, /Sendkey, /setvol, /hotkeylist, /init, /playlogo.jpg, /stop, /exit, /back, and /playinfo commands.
ZPanel 10.0.1 has insufficient entropy for its password reset process.
A clone version of an ELM327 OBD2 Bluetooth device has a hardcoded PIN, leading to arbitrary commands to an OBD-II bus of a vehicle.
SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.
The express install, which is the suggested way to install Puppet Enterprise, gives the user a URL at the end of the install to set the admin password. If they do not use that URL, there is an overlooked default password for the admin user. This was resolved in Puppet Enterprise 2019.0.3 and 2018.1.9.
Xerox AltaLink B8045/B8055/B8065/B8075/B8090, AltaLink C8030/C8035/C8045/C8055/C8070 with software releases before 103.xxx.030.32000 includes two accounts with weak hard-coded passwords which can be exploited and allow unauthorized access which cannot be disabled.
The Web-GUI on WAGO Series 750-88x (750-330, 750-352, 750-829, 750-831, 750-852, 750-880, 750-881, 750-882, 750-884, 750-885, 750-889) and Series 750-87x (750-830, 750-849, 750-871, 750-872, 750-873) devices has undocumented service access.
Juniper ATP ships with hard coded credentials in the Cyphort Core instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
ICS/StaticPages/AddTestUsers.aspx in Jenzabar JICS (aka Internet Campus Solution) before 2019-02-06 allows remote attackers to create an arbitrary number of accounts with a password of 1234.
Prisma Industriale Checkweigher PrismaWEB 1.21 allows remote attackers to discover the hardcoded prisma password for the prismaweb account by reading user/scripts/login_par.js.
A low privileged admin account with a weak default password of admin exists on the Foxconn FEMTO AP-FC4064-T AP_GT_B38_5.8.3lb15-W47 LTE Build 15. In addition, its web management page relies on the existence or values of cookies when performing security-critical operations. One can gain privileges by modifying cookies.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
An issue was discovered in the MBeans Server in Wowza Streaming Engine before 4.7.1. The file system may be read and written to via JMX using the default JMX credentials (remote code execution may be possible as well).
A vulnerability in Brocade Network Advisor Version Before 14.3.1 could allow an unauthenticated, remote attacker to log in to the JBoss Administration interface of an affected system using an undocumented user credentials and install additional JEE applications.
Meross MSS110 devices before 1.1.24 contain a TELNET listener providing access for an undocumented admin account with a blank password.
Certain NETGEAR devices are affected by a hardcoded password. This affects D3600 before 1.0.0.76 and D6000 before 1.0.0.76.
IBM Security Identity Governance and Intelligence 5.2 through 5.2.4.1 Virtual Appliance contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 153386.
Deltek Vision 7.x before 7.6 permits the execution of any attacker supplied SQL statement through a custom RPC over HTTP protocol. The Vision system relies on the client binary to enforce security rules and integrity of SQL statements and other content being sent to the server. Client HTTP calls can be manipulated by one of several means to execute arbitrary SQL statements (similar to SQLi) or possibly have unspecified other impact via this custom protocol. To perform these attacks an authenticated session is first required. In some cases client calls are obfuscated by encryption, which can be bypassed due to hard-coded keys and an insecure key rotation protocol. Impacts may include remote code execution in some deployments; however, the vendor states that this cannot occur when the installation documentation is heeded.
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
NUUO CMS all versions 3.1 and prior, The application creates default accounts that have hard-coded passwords, which could allow an attacker to gain privileged access.
A vulnerability in the install function of Cisco Prime Collaboration Provisioning (PCP) could allow an unauthenticated, remote attacker to access the administrative web interface using a default hard-coded username and password that are used during install. The vulnerability is due to a hard-coded password that, in some cases, is not replaced with a unique password. A successful exploit could allow the attacker to access the administrative web interface with administrator-level privileges.