Xerox ColorCube and WorkCenter devices in 2013 had hardcoded FTP and shell user accounts.
In Xerox FreeFlow Core version 8.0.4, an attacker can exploit a Path Traversal vulnerability to access unauthorized files on the server. This can lead to Remote Code Execution (RCE), allowing the attacker to run arbitrary commands on the system.
SQL injection vulnerability in summary.php in Xerox Fiery Webtools allows remote attackers to execute arbitrary SQL commands via the select parameter.
Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, and 7970i devices before 073.xxx.086.15410 do not properly escape parameters in the support/remoteUI/configrui.php script, which can allow an unauthenticated attacker to execute OS commands on the device.
Xerox Phaser 4622 v35.013.01.000 was discovered to contain a buffer overflow in the function sub_3226AC via the TIMEZONE variable. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. An attacker can execute PHP code by leveraging a writable file.
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is Blind SQL Injection.
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is unauthenticated Remote Command Execution.
Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 allows remote attackers to execute arbitrary code through a buffer overflow in Web page parameter handling.
Xerox AltaLink B80xx before 103.008.020.23120, C8030/C8035 before 103.001.020.23120, C8045/C8055 before 103.002.020.23120 and C8070 before 103.003.020.23120 has several SQL injection vulnerabilities.
Xerox Phaser 6510 before 64.61.23 and 64.59.11 (Bridge), WorkCentre 6515 before 65.61.23 and 65.59.11 (Bridge), VersaLink B400 before 37.61.23 and 37.59.01 (Bridge), B405 before 38.61.23 and 38.59.01 (Bridge), B600/B610 before 32.61.23 and 32.59.01 (Bridge), B605/B615 before 33.61.23 and 33.59.01 (Bridge), B7025/30/35 before 58.61.23 and 58.59.11 (Bridge), C400 before 67.61.23 and 67.59.01 (Bridge), C405 before 68.61.23 and 68.59.01 (Bridge), C500/C600 before 61.61.23 and 61.59.01 (Bridge), C505/C605 before 62.61.23 and 62.59.11 (Bridge), C7000 before 56.61.23 and 56.59.01 (Bridge), C7020/25/30 before 57.61.23 and 57.59.01 (Bridge), C8000/C9000 before 70.61.23 and 70.59.01 (Bridge), allows remote attackers with "a weaponized clone file" to execute arbitrary commands in the Web User Interface.
Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 have a remote Command Execution vulnerability in the Web User Interface that allows remote attackers with "a weaponized clone file" to execute arbitrary commands.
Pre-Auth RCE via Path Traversal
Pre-Auth RCE via Path Traversal
Unspecified vulnerability in the Web User Interface in Xerox WorkCentre and WorkCentre Pro before 12.050.03.000, 13.x before 13.050.03.000, and 14.x before 14.050.03.000 allows remote attackers to bypass authentication controls via unknown vectors.
Xerox WorkCentre and WorkCentre Pro before 12.060.17.000, 13.x before 13.060.17.000, and 14.x before 14.060.17.000 allow remote attackers to gain access via unspecified vectors related to "browser permissions."
Multiple unspecified vulnerabilities in Xerox WorkCentre and WorkCentre Pro before 12.050.03.000, 13.x before 13.050.03.000, and 14.x before 14.050.03.000 allow remote attackers to have an unspecified impact via unspecified vectors relating to "HTTP Security issues."
The Web User Interface in Xerox WorkCentre and WorkCentre Pro before 12.060.17.000, 13.x before 13.060.17.000, and 14.x before 14.060.17.000 allows remote attackers to execute arbitrary commands via unspecified vectors involving "command injection" in (1) the TCP/IP hostname, (2) Scan-to-mailbox folder names, and (3) certain parameters in the Microsoft Networking configuration. NOTE: vector 1 might be the same as CVE-2006-5290.
The SNMP implementation in Xerox WorkCentre and WorkCentre Pro before 12.050.03.000, 13.x before 13.050.03.000, and 14.x before 14.050.03.000 does not generate authentication failure traps, which allows remote attackers to more easily gain system access and obtain sensitive information via a brute force attack.
The ESS/ Network Controller and MicroServer Web Server components of Xerox WorkCentre and WorkCentre Pro 232, 238, 245, 255, 265 and 275 allow remote attackers to bypass authentication and execute arbitrary code via "WebUI command injection on TCP/IP hostname."
Multiple unspecified vulnerabilities in ESS/ Network Controller and MicroServer Web Server in Xerox WorkCentre Pro and Xerox WorkCentre running software 13.027.24.015 and 14.027.24.015 allow remote attackers to bypass authentication or gain "unauthorized network access" via unknown attack vectors.
Unknown vulnerability in Xerox MicroServer Web Server in Document Centre 220 through 265, 332 and 340, 420 through 490, and 535 through 555 allows remote attackers to bypass authentication.
Multiple unknown vulnerabilities in the MicroServer Web Server for Xerox WorkCentre Pro Color 2128, 2636, and 3545, version 0.001.04.044 through 0.001.04.504, allow attackers to bypass authentication.
The default configurations for DocuTech 6110 and DocuTech 6115 have a default administrative password of (1) "service!" on Solaris 8.0 or (2) "administ" on Windows NT, which allows remote attackers to gain privileges.
The default configuration of Xerox DocuTech 6110 and DocuTech 6115 running Solaris 8.0 has a large number of unnecessary services enabled such as RPC and sprayd, which could allow remote attackers to obtain access to the device.
Xerox AtlaLink B8045/B8055/B8065/B8075/B8090 C8030/C8035/C8045/C8055/C8070 printers with software before 101.00x.089.22600 allow an attacker to gain privileges.
Unknown vulnerability in the web server for the ESS/ Network Controller for Xerox Document Centre 240 through 555 running System Software 27.18.017 and earlier allows attackers to "gain unauthorized access."
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) were affected by one or more stack-based buffer overflow vulnerabilities in the Google Cloud Print implementation that would allow an unauthenticated attacker to execute arbitrary code on the device. This was caused by an insecure handling of the register parameters, because the size used within a memcpy() function, which copied the action value into a local variable, was not checked properly.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) were affected by a buffer overflow vulnerability in the Content-Type HTTP Header of the web application that would allow an attacker to execute arbitrary code on the device.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) were affected by a buffer overflow vulnerability in the Authentication Cookie of the web application that would allow an attacker to execute arbitrary code on the device.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) were affected by a buffer overflow vulnerability in the request parser of the IPP service. This would allow an unauthenticated attacker to cause a Denial of Service (DoS) and potentially execute arbitrary code on the device.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) were affected by a buffer overflow vulnerability in the attributes parser of the IPP service. This would allow an unauthenticated attacker to cause a Denial of Service (DoS) and potentially execute arbitrary code on the device.
The web application on Xerox AltaLink B80xx before 100.008.028.05200, C8030/C8035 before 100.001.028.05200, C8045/C8055 before 100.002.028.05200, and C8070 before 100.003.028.05200 allows unauthenticated command injection.
Juniper ATP ships with hard coded credentials in the Cyphort Core instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
The installation of Microsoft Exchange 2000 before Rev. A creates a user account with a known password, which could allow attackers to gain privileges, aka the "Exchange User Account" vulnerability.
Milesight IP security cameras through 2016-11-14 have a default root password in /etc/shadow that is the same across different customers' installations.
Use of Hard-coded Credentials in GitHub repository nuxtlabs/github-module prior to 1.6.2.
Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi.
A low privileged admin account with a weak default password of admin exists on the Foxconn FEMTO AP-FC4064-T AP_GT_B38_5.8.3lb15-W47 LTE Build 15. In addition, its web management page relies on the existence or values of cookies when performing security-critical operations. One can gain privileges by modifying cookies.
A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Milesight IP security cameras through 2016-11-14 have a default set of 10 privileged accounts with hardcoded credentials. They are accessible if the customer has not configured 10 actual user accounts.
Milesight IP security cameras through 2016-11-14 have a hardcoded SSL private key under the /etc/config directory.
A vulnerability in Cisco Emergency Responder could allow an unauthenticated, remote attacker to log in to an affected device using the root account, which has default, static credentials that cannot be changed or deleted. This vulnerability is due to the presence of static user credentials for the root account that are typically reserved for use during development. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
A vulnerability in Brocade Network Advisor Version Before 14.3.1 could allow an unauthenticated, remote attacker to log in to the JBoss Administration interface of an affected system using an undocumented user credentials and install additional JEE applications.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
An issue was discovered in the MBeans Server in Wowza Streaming Engine before 4.7.1. The file system may be read and written to via JMX using the default JMX credentials (remote code execution may be possible as well).
Use of Hard-coded Password in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX(-MS), WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800HP, WG1400HP, WR8175N, WR9300N, WR8750N, WR8160N, WR9500N, WR8600N, WR8370N, WR8170N, WR8700N, WR8300N, WR8150N, WR4100N, WR4500N, WR8100N, WR8500N, CR2500P, WR8400N, WR8200N, WR1200H, WR7870S, WR6670S, WR7850S, WR6650S, WR6600H, WR7800H, WM3400RN, WM3450RN, WM3500R, WM3600R, WM3800R, WR8166N, MR01LN MR02LN, WG1810HP(JE) and WG1810HP(MF) all versions allows a attacker to execute an arbitrary OS command via the internet.
Use of Hard-coded Credentials in GitHub repository alextselegidis/easyappointments prior to 1.5.0.