Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2018-3950

Summary
Assigner-talos
Assigner Org ID-b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b
Published At-01 Dec, 2018 | 04:00
Updated At-17 Sep, 2024 | 04:09
Rejected At-
Credits

An exploitable remote code execution vulnerability exists in the ping and tracert functionality of the TP-Link TL-R600VPN HWv3 FRNv1.3.0 and HWv2 FRNv1.2.3 http server. A specially crafted IP address can cause a stack overflow, resulting in remote code execution. An attacker can send a single authenticated HTTP request to trigger this vulnerability.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:talos
Assigner Org ID:b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b
Published At:01 Dec, 2018 | 04:00
Updated At:17 Sep, 2024 | 04:09
Rejected At:
▼CVE Numbering Authority (CNA)

An exploitable remote code execution vulnerability exists in the ping and tracert functionality of the TP-Link TL-R600VPN HWv3 FRNv1.3.0 and HWv2 FRNv1.2.3 http server. A specially crafted IP address can cause a stack overflow, resulting in remote code execution. An attacker can send a single authenticated HTTP request to trigger this vulnerability.

Affected Products
Vendor
Talos (Cisco Systems, Inc.)Talos
Product
TP-Link
Versions
Affected
  • TP-Link TL-R600VPN HWv3 FRNv1.3.0 TP-Link TL-R600VPN HWv2 FRNv1.2.3
Problem Types
TypeCWE IDDescription
textN/AClassic Buffer Overflow
Type: text
CWE ID: N/A
Description: Classic Buffer Overflow
Metrics
VersionBase scoreBase severityVector
3.07.2HIGH
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Version: 3.0
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://talosintelligence.com/vulnerability_reports/TALOS-2018-0619
x_refsource_MISC
Hyperlink: https://talosintelligence.com/vulnerability_reports/TALOS-2018-0619
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://talosintelligence.com/vulnerability_reports/TALOS-2018-0619
x_refsource_MISC
x_transferred
Hyperlink: https://talosintelligence.com/vulnerability_reports/TALOS-2018-0619
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:talos-cna@cisco.com
Published At:01 Dec, 2018 | 04:29
Updated At:03 Feb, 2023 | 18:02

An exploitable remote code execution vulnerability exists in the ping and tracert functionality of the TP-Link TL-R600VPN HWv3 FRNv1.3.0 and HWv2 FRNv1.2.3 http server. A specially crafted IP address can cause a stack overflow, resulting in remote code execution. An attacker can send a single authenticated HTTP request to trigger this vulnerability.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.07.2HIGH
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.0
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

TP-Link Systems Inc.
tp-link
>>tl-r600vpn_firmware>>1.3.0
cpe:2.3:o:tp-link:tl-r600vpn_firmware:1.3.0:*:*:*:*:*:*:*
TP-Link Systems Inc.
tp-link
>>tl-r600vpn>>3
cpe:2.3:h:tp-link:tl-r600vpn:3:*:*:*:*:*:*:*
TP-Link Systems Inc.
tp-link
>>tl-r600vpn_firmware>>1.2.3
cpe:2.3:o:tp-link:tl-r600vpn_firmware:1.2.3:*:*:*:*:*:*:*
TP-Link Systems Inc.
tp-link
>>tl-r600vpn>>2
cpe:2.3:h:tp-link:tl-r600vpn:2:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-787Primarynvd@nist.gov
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://talosintelligence.com/vulnerability_reports/TALOS-2018-0619talos-cna@cisco.com
Exploit
Third Party Advisory
Hyperlink: https://talosintelligence.com/vulnerability_reports/TALOS-2018-0619
Source: talos-cna@cisco.com
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

606Records found

CVE-2024-0533
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.19% / 41.10%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 02:31
Updated-13 Jun, 2025 | 19:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A15 Web-based Management Interface SetOnlineDevName stack-based overflow

A vulnerability was found in Tenda A15 15.13.07.13. It has been rated as critical. This issue affects some unknown processing of the file /goform/SetOnlineDevName of the component Web-based Management Interface. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250703. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a15a15_firmwareA15
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-28508
Matching Score-4
Assigner-Rapid7, Inc.
ShareView Details
Matching Score-4
Assigner-Rapid7, Inc.
CVSS Score-8.8||HIGH
EPSS-0.16% / 37.26%
||
7 Day CHG~0.00%
Published-29 Mar, 2023 | 20:16
Updated-18 Feb, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Heap corruption in UniRPC service

Rocket Software UniData versions prior to 8.2.4 build 3003 and UniVerse versions prior to 11.3.5 build 1001 or 12.2.1 build 2002 suffer from a heap-based overflow vulnerability, where certain input can corrupt the heap and crash the forked process.

Action-Not Available
Vendor-rocketsoftwareRocket SoftwareLinux Kernel Organization, Inc
Product-universeunidatalinux_kernelUniDataUniVerse
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-28572
Matching Score-4
Assigner-Qualcomm, Inc.
ShareView Details
Matching Score-4
Assigner-Qualcomm, Inc.
CVSS Score-6.6||MEDIUM
EPSS-0.10% / 28.63%
||
7 Day CHG~0.00%
Published-07 Nov, 2023 | 05:26
Updated-02 Aug, 2024 | 13:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Buffer Over-read in WLAN HOST

Memory corruption in WLAN HOST while processing the WLAN scan descriptor list.

Action-Not Available
Vendor-Qualcomm Technologies, Inc.
Product-qca9377_firmwarewsa8830wcd9380_firmwaresa6150p_firmwaresa8145p_firmwaresw5100pmsm8996au_firmwareqca6554afastconnect_6800qca6595qca6431_firmwareqca6564aucsrb31024mdm9628_firmwaresnapdragon_820_automotive_platform_firmwaresnapdragon_865_5g_mobile_platformsnapdragon_870_5g_mobile_platform_firmwarewsa8835qca6574msm8996ausnapdragon_auto_5g_modem-rfwcd9380sa8150p_firmwareqca6595au_firmwaresnapdragon_auto_4g_modem_firmwareqca6574aqca9379_firmwareqca6174aqca6426qca6584au_firmwareqca6564awcn3980qca9377qcc2076_firmwareqca6554a_firmwarewcd9385_firmwareqam8295pqcc2073_firmwaremdm9628qca6574_firmwarewsa8815snapdragon_865\+_5g_mobile_platformqam8295p_firmwareqca6175aqca6426_firmwaresnapdragon_x55_5g_modem-rf_systemqca6574a_firmwareqca6574au_firmwareqca6595auwcn3980_firmwaresnapdragon_x55_5g_modem-rf_system_firmwareqca6391qca6436_firmwaresnapdragon_820_automotive_platformsa8295pqca6421_firmwarefastconnect_7800qca6564au_firmwareqca6584ausa6155p_firmwaresnapdragon_auto_5g_modem-rf_firmwaresnapdragon_865\+_5g_mobile_platform_firmwaresnapdragon_870_5g_mobile_platformqca6678aq_firmwaresnapdragon_auto_4g_modemqca6678aqcsrb31024_firmwareqca6698aqfastconnect_6900fastconnect_6900_firmwarewcn3988_firmwareqca6574ausa6145p_firmwaresa8155p_firmwareqca6421qca6564a_firmwaresa8195pwsa8810_firmwarefastconnect_7800_firmwaresw5100wsa8810qca6436sa6155psw5100p_firmwareqca6698aq_firmwaresa6145pqca6174a_firmwarewcd9385qca6431qca6696_firmwareqca6595_firmwaresa8145pqca6696qca6391_firmwaresa8150psa6150psa8155pwsa8830_firmwareqcc2076wcn3988wsa8815_firmwarewsa8835_firmwaresa8195p_firmwaresnapdragon_865_5g_mobile_platform_firmwaresw5100_firmwarefastconnect_6800_firmwaresa8295p_firmwareqca9379qcc2073qca6175a_firmwareSnapdragon
CWE ID-CWE-126
Buffer Over-read
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2987
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.72% / 71.66%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2989
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.96%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 NatStaticSetting fromNatStaticSetting stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258158 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2977
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 65.92%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 13:31
Updated-15 Jan, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-28506
Matching Score-4
Assigner-Rapid7, Inc.
ShareView Details
Matching Score-4
Assigner-Rapid7, Inc.
CVSS Score-8.8||HIGH
EPSS-0.19% / 41.64%
||
7 Day CHG~0.00%
Published-29 Mar, 2023 | 20:13
Updated-18 Feb, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Stack buffer overflow in UniRPC service

Rocket Software UniData versions prior to 8.2.4 build 3003 and UniVerse versions prior to 11.3.5 build 1001 or 12.2.1 build 2002 suffer from a stack-based buffer overflow, where a string is copied into a buffer using a memcpy-like function and a user-provided length. This requires a valid login to exploit.

Action-Not Available
Vendor-rocketsoftwareRocket SoftwareLinux Kernel Organization, Inc
Product-universeunidatalinux_kernelUniDataUniVerse
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2983
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 SetClientState formSetClientState stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258152. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3006
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 62.70%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 22:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 fromRouteStatic fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-2923
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.10% / 27.66%
||
7 Day CHG~0.00%
Published-27 May, 2023 | 07:31
Updated-02 Aug, 2024 | 06:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 fromDhcpListClient stack-based overflow

A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Affected by this vulnerability is the function fromDhcpListClient. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-230077 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6_firmwareac6AC6
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2979
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.15%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 14:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 openSchedWifi setSchedWifi stack-based overflow

A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2992
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.14%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:00
Updated-22 Jan, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203_firmwarefh1203FH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2976
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.00% / 76.11%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 13:31
Updated-15 Jan, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3011
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.42% / 60.90%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-15 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2990
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.96%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 execCommand formexeCommand stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. This affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258159. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2981
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.19% / 77.95%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 15:00
Updated-14 Jan, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2895
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.14%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 17:31
Updated-22 Jan, 2025 | 17:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2898
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.14%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 18:31
Updated-22 Jan, 2025 | 17:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2805
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.04% / 76.60%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 03:00
Updated-24 Jan, 2025 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2903
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.01% / 76.22%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:31
Updated-22 Jan, 2025 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2899
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.15%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 19:00
Updated-10 Apr, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2901
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.15%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:00
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 openSchedWifi setSchedWifi stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2894
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.15%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 17:00
Updated-22 Jan, 2025 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetNetControlList formSetQosBand stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4355
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.09% / 25.98%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 12:31
Updated-13 May, 2025 | 20:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda DAP-1520 api set_ws_action heap-based overflow

A vulnerability was found in Tenda DAP-1520 1.10B04_BETA02. It has been classified as critical. This affects the function set_ws_action of the file /dws/api/. The manipulation leads to heap-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.D-Link Corporation
Product-dap-1520_firmwaredap-1520DAP-1520
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2896
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.15%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 18:00
Updated-22 Jan, 2025 | 17:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2892
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.21% / 43.79%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:00
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 setcfm formSetCfm stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-48725
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-26.04% / 96.08%
||
7 Day CHG~0.00%
Published-07 Mar, 2024 | 14:59
Updated-11 Mar, 2025 | 16:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the JSON Parsing getblockschedule() functionality of Netgear RAX30 1.0.11.96 and 1.0.7.78. A specially crafted HTTP request can lead to code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-rax30rax30_firmwareRAX30rax30_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2711
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.76%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 18:00
Updated-12 Dec, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U addWifiMacFilter stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-47004
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.43%
||
7 Day CHG~0.00%
Published-06 Nov, 2023 | 00:00
Updated-29 Apr, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer Overflow vulnerability in Redis RedisGraph v.2.x through v.2.12.8 and fixed in v.2.12.9 allows an attacker to execute arbitrary code via the code logic after valid authentication.

Action-Not Available
Vendor-n/aRedis Inc.
Product-redisgraphn/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2705
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.21%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:31
Updated-12 Dec, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetNetControlList formSetQosBand stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2703
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.04% / 76.55%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:00
Updated-12 Dec, 2024 | 17:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-27042
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.75%
||
7 Day CHG~0.00%
Published-24 Mar, 2023 | 00:00
Updated-20 Feb, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX3 V16.03.12.11 is vulnerable to Buffer Overflow via /goform/SetFirewallCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax3ax3_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24958
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-8.8||HIGH
EPSS-0.19% / 41.37%
||
7 Day CHG~0.00%
Published-04 May, 2023 | 13:38
Updated-29 Jan, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
IBM TS7700 Management Interface command injection

A vulnerability in the IBM TS7700 Management Interface 8.51.2.12, 8.52.200.111, 8.52.102.13, and 8.53.0.63 could allow an authenticated user to submit a specially crafted URL leading to privilege escalation and remote code execution. IBM X-Force ID: 246320.

Action-Not Available
Vendor-IBM Corporation
Product-3957-vec_firmware3948-ved3957-ved3948-ved_firmware3957-ved_firmware3957-vecVirtualization Engine TS7700
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-6963
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.19% / 83.71%
||
7 Day CHG~0.00%
Published-20 Jun, 2019 | 13:47
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A heap-based buffer overflow in cosa_dhcpv4_dml.c in the RDK RDKB-20181217-1 CcspPandM module may allow attackers with login credentials to achieve remote code execution by crafting a long buffer in the "Comment" field of an IP reservation form in the admin panel. This is related to the CcspCommonLibrary module.

Action-Not Available
Vendor-rdkcentraln/a
Product-rdkb_ccsppandmn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-25267
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.13% / 33.88%
||
7 Day CHG~0.00%
Published-15 Mar, 2023 | 00:00
Updated-27 Feb, 2025 | 14:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in GFI Kerio Connect 9.4.1 patch 1 (fixed in 10.0.0). There is a stack-based Buffer Overflow in the webmail component's 2FASetup function via an authenticated request with a long primaryEMailAddress field to the webmail/api/jsonrpc URI.

Action-Not Available
Vendor-gfin/a
Product-kerio_connectn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-2575
Matching Score-4
Assigner-CyberDanube
ShareView Details
Matching Score-4
Assigner-CyberDanube
CVSS Score-8.8||HIGH
EPSS-2.18% / 83.69%
||
7 Day CHG~0.00%
Published-08 May, 2023 | 12:11
Updated-13 Feb, 2025 | 16:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Buffer Overflow

Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by a Stack-based Buffer Overflow vulnerability, which can be triggered by authenticated users via a crafted POST request.

Action-Not Available
Vendor-Advantech (Advantech Co., Ltd.)
Product-eki-1524eki-1521_firmwareeki-1524_firmwareeki-1521eki-1522_firmwareeki-1522EKI-1524EKI-1521EKI-1522
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-21890
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-2.97% / 85.98%
||
7 Day CHG~0.00%
Published-22 Dec, 2021 | 18:06
Updated-03 Aug, 2024 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the Web Manager FsBrowseClean functionality of Lantronix PremierWave 2050 8.9.0.0R4 (in QEMU). A specially crafted HTTP request can lead to remote code execution in the vulnerable portion of the branch (deletedir). An attacker can make an authenticated HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-lantronixn/a
Product-premierwave_2050_firmwarepremierwave_2050Lantronix
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2704
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.99% / 75.96%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:00
Updated-12 Dec, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetFirewallCfg formSetFirewallCfg stack-based overflow

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2710
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.76%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 18:00
Updated-12 Dec, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U openSchedWifi setSchedWifi stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-3328
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.17% / 39.00%
||
7 Day CHG~0.00%
Published-07 Apr, 2025 | 00:31
Updated-07 Apr, 2025 | 18:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 fast_setting_wifi_set form_fast_setting_wifi_set buffer overflow

A vulnerability was found in Tenda AC1206 15.03.06.23. It has been classified as critical. Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid/timeZone leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206ac1206_firmwareAC1206
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-23780
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-7.6||HIGH
EPSS-0.46% / 63.21%
||
7 Day CHG~0.00%
Published-16 Feb, 2023 | 18:05
Updated-23 Oct, 2024 | 14:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow in Fortinet FortiWeb version 7.0.0 through 7.0.1, Fortinet FortiWeb version 6.3.6 through 6.3.19, Fortinet FortiWeb 6.4 all versions allows attacker to escalation of privilege via specifically crafted HTTP requests.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortiwebFortiWeb
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24097
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.82%
||
7 Day CHG~0.00%
Published-23 Jan, 2023 | 00:00
Updated-02 Apr, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TrendNet Wireless AC Easy-Upgrader TEW-820AP v1.0R, firmware version 1.01.B01 was discovered to contain a stack overflow via the submit-url parameter at /formPasswordAuth. This vulnerability allows attackers to execute arbitrary code via a crafted payload. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-n/aTRENDnet, Inc.
Product-tew-820ap_firmwaretew-820apn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24347
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.49% / 64.65%
||
7 Day CHG~0.00%
Published-10 Feb, 2023 | 00:00
Updated-24 Mar, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link N300 WI-FI Router DIR-605L v2.13B01 was discovered to contain a stack overflow via the webpage parameter at /goform/formSetWanDhcpplus.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-605l_firmwaredir-605ln/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24346
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.24% / 78.40%
||
7 Day CHG~0.00%
Published-10 Feb, 2023 | 00:00
Updated-24 Mar, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link N300 WI-FI Router DIR-605L v2.13B01 was discovered to contain a stack overflow via the wan_connected parameter at /goform/formEasySetupWizard3.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-605l_firmwaredir-605ln/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-23781
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-6.1||MEDIUM
EPSS-0.22% / 45.20%
||
7 Day CHG+0.02%
Published-16 Feb, 2023 | 18:06
Updated-23 Oct, 2024 | 14:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability [CWE-121] in FortiWeb version 7.0.1 and below, 6.4 all versions, version 6.3.19 and below SAML server configuration may allow an authenticated attacker to achieve arbitrary code execution via specifically crafted XML files.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortiwebFortiWeb
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2764
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.73% / 71.73%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24099
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.82%
||
7 Day CHG~0.00%
Published-23 Jan, 2023 | 00:00
Updated-02 Aug, 2024 | 11:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TrendNet Wireless AC Easy-Upgrader TEW-820AP v1.0R, firmware version 1.01.B01 was discovered to contain a stack overflow via the username parameter at /formWizardPassword. This vulnerability allows attackers to execute arbitrary code via a crafted payload. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-n/aTRENDnet, Inc.
Product-tew-820ap_firmwaretew-820apn/atew-820ap_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24018
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-0.14% / 35.13%
||
7 Day CHG~0.00%
Published-06 Jul, 2023 | 14:53
Updated-02 Aug, 2024 | 10:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the libzebra.so.0.0.0 security_decrypt_password functionality of Milesight UR32L v32.3.0.5. A specially crafted HTTP request can lead to a buffer overflow. An authenticated attacker can send an HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-Milesight
Product-ur32l_firmwareur32lUR32Lur32l_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24344
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.41% / 84.50%
||
7 Day CHG~0.00%
Published-10 Feb, 2023 | 00:00
Updated-24 Mar, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link N300 WI-FI Router DIR-605L v2.13B01 was discovered to contain a stack overflow via the webpage parameter at /goform/formWlanGuestSetup.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-605l_firmwaredir-605ln/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24343
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-6.27% / 90.55%
||
7 Day CHG~0.00%
Published-10 Feb, 2023 | 00:00
Updated-24 Mar, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link N300 WI-FI Router DIR-605L v2.13B01 was discovered to contain a stack overflow via the curTime parameter at /goform/formSchedule.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-605l_firmwaredir-605ln/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • ...
  • 6
  • 7
  • 8
  • ...
  • 12
  • 13
  • Next
Details not found