In SapphireIMS 5.0, it is possible to take over an account by sending a request to the Save_Password form as shown in POC. Notice that we do not require a JSESSIONID in this request and can reset any user’s password by changing the username to that user and password to base64(desired password).
In SapphireIMS 5.0, it is possible to create local administrator on any client without requiring any credentials by directly accessing RemoteMgmtTaskSave (Automation Tasks) feature and not having a JSESSIONID.
Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.
The Micro Air Vehicle Link (MAVLink) protocol presents no authentication mechanism on its version 1.0 (nor authorization) whichs leads to a variety of attacks including identity spoofing, unauthorized access, PITM attacks and more. According to literature, version 2.0 optionally allows for package signing which mitigates this flaw. Another source mentions that MAVLink 2.0 only provides a simple authentication system based on HMAC. This implies that the flying system overall should add the same symmetric key into all devices of network. If not the case, this may cause a security issue, that if one of the devices and its symmetric key are compromised, the whole authentication system is not reliable.
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
The SolarWinds Orion API is vulnerable to an authentication bypass that could allow a remote attacker to execute API commands. This vulnerability could allow a remote attacker to bypass authentication and execute API commands which may result in a compromise of the SolarWinds instance. SolarWinds Orion Platform versions 2019.4 HF 5, 2020.2 with no hotfix installed, and 2020.2 HF 1 are affected.
The WPGraphQL 0.2.3 plugin for WordPress allows remote attackers to register a new user with admin privileges, whenever new user registrations are allowed. This is related to the registerUser mutation.
Jector Smart TV FM-K75 devices allow remote code execution because there is an adb open port with root permission.
On Netis WF2411 with firmware 2.1.36123 and other Netis WF2xxx devices (possibly WF2411 through WF2880), there is a stack-based buffer overflow that does not require authentication. This can cause denial of service (device restart) or remote code execution. This vulnerability can be triggered by a GET request with a long HTTP "Authorization: Basic" header that is mishandled by user_auth->user_ok in /bin/boa.
An issue was discovered on D-Link DIR-878 1.12B01 devices. Because strncpy is misused, there is a stack-based buffer overflow vulnerability that does not require authentication via the HNAP_AUTH HTTP header.
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
An issue was discovered on Shenzhen Coship WM3300 WiFi Router 5.0.0.55 devices. The password reset functionality of the Wireless SSID doesn't require any type of authentication. By making a POST request to the regx/wireless/wl_security_2G.asp URI, the attacker can change the password of the Wi-FI network.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
ONTAP Select Deploy administration utility versions 2.12 & 2.12.1 ship with an HTTP service bound to the network allowing unauthenticated remote attackers to perform administrative actions.
ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
An issue was discovered in Tyto Sahi Pro 6.x through 8.0.0. TestRunner_Non_distributed (and distributed end points) does not have any authentication mechanism. This allow an attacker to execute an arbitrary script on the remote Sahi Pro server. There is also a password-protected web interface intended for remote access to scripts. This web interface lacks server-side validation, which allows an attacker to create/modify/delete a script remotely without any password. Chaining both of these issues results in remote code execution on the Sahi Pro server.
It was found that default configuration of Heketi does not require any authentication potentially exposing the management interface to misuse. This isue only affects heketi as shipped with Openshift Container Platform 3.11.
A broken access control vulnerability found in Advan VD-1 firmware version 230 leads to insecure ADB service. An attacker can send a POST request to cgibin/AdbSetting.cgi to enable ADB without any authentication then take the compromised device as a relay or to install mining software.
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
Systematic IRIS WebForms 5.4 and its functionalities can be accessed and used without any form of authentication.
The RSA Identity Governance and Lifecycle and RSA Via Lifecycle and Governance products prior to 7.1.1 P03 contain an Improper Authentication vulnerability. A Java JMX agent running on the remote host is configured with plain text password authentication. An unauthenticated remote attacker can connect to the JMX agent and monitor and manage the Java application.
wan.htm page on Zyxel NBG-418N v2 with firmware version V1.00(AARP.9)C0 can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify data fields of the page.
The nd-restaurant-reservations plugin before 1.5 for WordPress has no requirement for nd_rst_import_settings_php_function authentication.
Intesync Solismed 3.3sp has Incorrect Access Control.
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.
An issue was discovered in Zoho ManageEngine OpManager in builds before 14310. One can bypass the user password requirement and execute commands on the server. The "username+'@opm' string is used for the password. For example, if the username is admin, the password is admin@opm.
HiNet GPON firmware version < I040GWR190731 allows an attacker login to device without any authentication.
The querier component in Grafana Enterprise Logs 1.1.x through 1.3.x before 1.4.0 does not require authentication when X-Scope-OrgID is used. Versions 1.2.1, 1.3.1, and 1.4.0 contain the bugfix. This affects -auth.type=enterprise in microservices mode
Directus 7 API before 2.2.2 has insufficient anti-automation, as demonstrated by lack of a CAPTCHA in core/Directus/Services/AuthService.php and endpoints/Auth.php.
In mintplex-labs/anything-llm v1.5.11 desktop version for Windows, the application opens server port 3001 on 0.0.0.0 with no authentication by default. This vulnerability allows an attacker to gain full backend access, enabling them to perform actions such as deleting all data from the workspace.
Super Micro SuperDoctor 5, when restrictions are not implemented in agent.cfg, allows remote attackers to execute arbitrary commands via NRPE.
An issue was discovered in ONAP HOLMES before Dublin. By accessing port 9202 of dep-holmes-engine-mgmt pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4001 of demo-sdc-sdc-onboarding-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 6000 of demo-sdc-sdc-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in upgrade_htmls.cgi on VStarcam 100T (C7824WIP) KR75.8.53.20 and 200V (C38S) KR203.18.1.20 devices. The web service, network, and account files can be manipulated through a web UI firmware update without any authentication. The attacker can achieve access to the device through a manipulated web UI firmware update.
An issue was discovered in ONAP SDC through Dublin. By accessing port 7000 of demo-sdc-sdc-wfd-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in upgrade_firmware.cgi on VStarcam 100T (C7824WIP) CH-sys-48.53.75.119~123 and 200V (C38S) CH-sys-48.53.203.119~123 devices. A remote command can be executed through a system firmware update without authentication. The attacker can modify the files within the internal firmware or even steal account information by executing a command.
In ONAP DCAE through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 7001 of demo-sdc-sdc-wfd-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
Anviz access control devices allow remote attackers to issue commands without a password.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4000 of demo-sdc-sdc-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in Squid through 4.7. When handling requests from users, Squid checks its rules to see if the request should be denied. Squid by default comes with rules to block access to the Cache Manager, which serves detailed server information meant for the maintainer. This rule is implemented via url_regex. The handler for url_regex rules URL decodes an incoming request. This allows an attacker to encode their URL to bypass the url_regex check, and gain access to the blocked resource.
An issue was discovered on D-Link DIR-600M 3.02, 3.03, 3.04, and 3.06 devices. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
In ONAP Logging through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
RedwoodHQ 2.5.5 does not require any authentication for database operations, which allows remote attackers to create admin users via a con.automationframework users insert_one call.
An Incorrect Access Control vulnerability was found in Wikimedia MediaWiki 1.27.0 through 1.32.1. Directly POSTing to Special:ChangeEmail would allow for bypassing re-authentication, allowing for potential account takeover.
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.