Trend Micro Apex One (2019), OfficeScan XG and Worry-Free Business Security (9.0, 9.5, 10.0) server contains a vulnerable service DLL file that could allow a remote attacker to execute arbitrary code on affected installations with SYSTEM level privileges. Authentication is not required to exploit this vulnerability.
The Invoker Servlet on SAP NetWeaver Application Server Java platforms, possibly before 7.3, does not require authentication, which allows remote attackers to execute arbitrary code via an HTTP or HTTPS request, as exploited in the wild in 2013 through 2016, aka a "Detour" attack.
The vSphere Client (HTML5) contains a vulnerability in a vSphere authentication mechanism for the Virtual SAN Health Check, Site Recovery, vSphere Lifecycle Manager, and VMware Cloud Director Availability plug-ins. A malicious actor with network access to port 443 on vCenter Server may perform actions allowed by the impacted plug-ins without authentication.
VR CAM P1 Model P1 v1 has an incorrect access control vulnerability where an attacker can obtain complete access of the device from web (remote) without authentication.
NUUO NVRmini2 through 3.11 allows an unauthenticated attacker to upload an encrypted TAR archive, which can be abused to add arbitrary users because of the lack of handle_import_user.php authentication. When combined with another flaw (CVE-2011-5325), it is possible to overwrite arbitrary files under the web root and achieve code execution as root.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allow Authentication Bypass in its administrative web interface.
A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution.
A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server.
A vulnerability in the REST API of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to access the back-end database of an affected system. The vulnerability exists because the affected software does not properly authenticate REST API calls. An attacker could exploit this vulnerability by obtaining a cross-site request forgery (CSRF) token and then using the token with REST API requests. A successful exploit could allow the attacker to access the back-end database of the affected device and read, alter, or drop information.
HPE Data Protector before 7.03_108, 8.x before 8.15, and 9.x before 9.06 allow remote attackers to execute arbitrary code via unspecified vectors related to lack of authentication. NOTE: this vulnerability exists because of an incomplete fix for CVE-2014-2623.
Emerson Dixell XWEB-500 products are affected by arbitrary file write vulnerability in /cgi-bin/logo_extra_upload.cgi, /cgi-bin/cal_save.cgi, and /cgi-bin/lo_utils.cgi. An attacker will be able to write any file on the target system without any kind of authentication mechanism, and this can lead to denial of service and potentially remote code execution. Note: the product has not been supported since 2018 and should be removed or replaced
In Totolink A3100R V5.9c.4577, multiple pages can be read by curl or Burp Suite without authentication. Additionally, admin configurations can be set without cookies.
Missing Authentication for Critical Function vulnerability in debug_post_set.cgi of D-Link DWR-932C E1 firmware allows an unauthenticated attacker to execute administrative actions.
There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.
A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges.
The telnet daemon (telnetd) in MIT krb5 before 1.6.1 allows remote attackers to bypass authentication and gain system access via a username beginning with a '-' character, a similar issue to CVE-2007-0882.
Arbitrary code execution vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to execute arbitrary code on affected installations of OBR.
OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000.
In ONAP CLI through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
In ONAP SO through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system.
Emerson OpenEnterprise versions through 3.3.4 may allow an attacker to run an arbitrary commands with system privileges or perform remote code execution via a specific communication service.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port 9999 by default. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-10493.
Contec Smart Home 4.15 devices do not require authentication for new_user.php, edit_user.php, delete_user.php, and user.php, as demonstrated by changing the admin password and then obtaining control over doors.
This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482.
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
Multiple vulnerabilities in Cisco Application Services Engine could allow an unauthenticated, remote attacker to gain privileged access to host-level operations or to learn device-specific information, create diagnostic files, and make limited configuration changes. For more information about these vulnerabilities, see the Details section of this advisory.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use a hidden API URL /goform/SystemCommand to execute a system command without authentication.
Control Web Panel Missing Authentication Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Control Web Panel. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of authentication within the web interface. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of a valid CWP user. Was ZDI-CAN-20582.
Veeam Backup & Replication 10.x and 11.x has Incorrect Access Control (issue 1 of 2).
AOMEI Cyber Backup Missing Authentication for Critical Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AOMEI Cyber Backup. Authentication is not required to exploit this vulnerability. The specific flaw exists within the StorageNode service, which listens on TCP port 9075 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-26156.
AOMEI Cyber Backup Missing Authentication for Critical Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AOMEI Cyber Backup. Authentication is not required to exploit this vulnerability. The specific flaw exists within the DaoService service, which listens on TCP port 9074 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-26158.
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain commands to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to obtain full file-system access and remote code execution.
In IOBit IOTransfer 4.3.1.1561, an unauthenticated attacker can send GET and POST requests to Airserv and gain arbitrary read/write access to the entire file-system (with admin privileges) on the victim's endpoint, which can result in data theft and remote code execution.
The ClearPass Policy Manager web interface is affected by a vulnerability that leads to authentication bypass. Upon successful bypass an attacker could then execute an exploit that would allow to remote command execution in the underlying operating system. Resolution: Fixed in 6.7.13-HF, 6.8.5-HF, 6.8.6, 6.9.1 and higher.
SAP Solution Manager (User Experience Monitoring), version- 7.2, due to Missing Authentication Check does not perform any authentication for a service resulting in complete compromise of all SMDAgents connected to the Solution Manager.
SAP Business Objects Business Intelligence Platform (Live Data Connect), versions 1.0, 2.0, 2.1, 2.2, 2.3, allows an attacker to logon on the Central Management Console without password in case of the BIPRWS application server was not protected with some specific certificate, leading to Missing Authentication Check.
The official telegraf docker images before 1.9.4-alpine (Alpine specific) contain a blank password for a root user. System using the telegraf docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
The official composer docker images before 1.8.3 contain a blank password for a root user. System using the composer docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
The official drupal docker images before 8.5.10-fpm-alpine (Alpine specific) contain a blank password for a root user. System using the drupal docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
The official haproxy docker images before 1.8.18-alpine (Alpine specific) contain a blank password for a root user. System using the haproxy docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
The official ghost docker images before 2.16.1-alpine (Alpine specific) contain a blank password for a root user. System using the ghost docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
The official plone Docker images before version of 4.3.18-alpine (Alpine specific) contain a blank password for a root user. System using the plone docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
The official sonarqube docker images before alpine (Alpine specific) contain a blank password for a root user. System using the sonarqube docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
Version 3.16.0 of the CoScale agent Docker image contains a blank password for the root user. Systems deployed using affected versions of the CoScale agent container may allow a remote attacker to achieve root access with a blank password.
The official kong docker images before 1.0.2-alpine (Alpine specific) contain a blank password for a root user. System using the kong docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
The Software AG Terracotta Server OSS Docker image 5.4.1 contains a blank password for the root user. Systems deployed using affected versions of the Terracotta Server OSS container may allow a remote attacker to achieve root access with a blank password.
The Appbase streams Docker image 2.1.2 contains a blank password for the root user. Systems deployed using affected versions of the streams container may allow a remote attacker to achieve root access with a blank password.
The official adminer docker images before 4.7.0-fastcgi contain a blank password for a root user. System using the adminer docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.