Moxa IKS and EDS store plaintext passwords, which may allow sensitive information to be read by someone with access to the device.
In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner.
The private key of the web server in Moxa MXview versions 2.8 and prior is able to be read and accessed via an HTTP GET request, which may allow a remote attacker to decrypt encrypted information.
In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing a specific uniform resource locator (URL) on the webserver, a malicious user may be able to access information in the application without authenticating.
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
ABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonymous authentication, and specific key values within the eSOMS web.config file are present. Both conditions are required to exploit this vulnerability.
For Crestron TSW-X60 version prior to 2.001.0037.001 and MC3 version prior to 1.502.0047.001, The devices are shipped with authentication disabled, and there is no indication to users that they need to take steps to enable it. When compromised, the access to the CTP console is left open.
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.
In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.
An attacker can log into the local Niagara platform (Niagara AX Framework Versions 3.8 and prior or Niagara 4 Framework Versions 4.4 and prior) using a disabled account name and a blank password, granting the attacker administrator access to the Niagara system.
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process.
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data.
LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remote code on the server.
NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The device allows access to configuration files and profiles without authenticating the user.
NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The directory of the device is listed openly without authentication.
In ABB SREA-01 revisions A, B, C: application versions up to 3.31.5, and SREA-50 revision A: application versions up to 3.32.8, an attacker may access internal files of ABB SREA-01 and SREA-50 legacy remote monitoring tools without any authorization over the network using a HTTP request which refers to files using ../../ relative paths. Once the internal password file is retrieved, the password hash can be identified using a brute force attack. There is also an exploit allowing running of commands after authorization.
Moxa IKS and EDS do not implement sufficient measures to prevent multiple failed authentication attempts, which may allow an attacker to discover passwords via brute force attack.
In Omron CX-Supervisor Versions 3.30 and prior, access of uninitialized pointer vulnerabilities can be exploited when CX Supervisor indirectly calls an initialized pointer when parsing malformed packets.
Beckhoff TwinCAT 3 supports communication over ADS. ADS is a protocol for industrial automation in protected environments. This protocol uses user configured routes, that can be edited remotely via ADS. This special command supports encrypted authentication with username/password. The encryption uses a fixed key, that could be extracted by an attacker. Precondition of the exploitation of this weakness is network access at the moment a route is added.
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP.
A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
Rundeck is an open source automation service with a web console, command line tools and a WebAPI. The Key Storage converter plugin mechanism was not enabled correctly in Rundeck 4.2.0 and 4.2.1, resulting in use of the encryption layer for Key Storage possibly not working. Any credentials created or overwritten using Rundeck 4.2.0 or 4.2.1 might result in them being written in plaintext to the backend storage. This affects those using any `Storage Converter` plugin. Rundeck 4.3.1 and 4.2.2 have fixed the code and upon upgrade will re-encrypt any plain text values. Version 4.3.0 does not have the vulnerability, but does not include the patch to re-encrypt plain text values if 4.2.0 or 4.2.1 were used. To prevent plaintext credentials from being stored in Rundeck 4.2.0/4.2.1, write access to key storage can be disabled via ACLs. After upgrading to 4.3.1 or later, write access can be restored.
A weakness has been identified in Intelbras UnniTI 24.07.11. The affected element is an unknown function of the file /xml/sistema/usuarios.xml. Executing manipulation of the argument Usuario/Senha can lead to unprotected storage of credentials. The attack can be executed remotely. The exploit has been made available to the public and could be exploited.
A security vulnerability has been detected in Intelbras ICIP 2.0.20. Affected is an unknown function of the file /xml/sistema/acessodeusuario.xml. Such manipulation of the argument NomeUsuario/SenhaAcess leads to unprotected storage of credentials. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.
An issue was discovered in the 3CX Phone System Management Console prior to version 18 Update 3 FINAL. An unauthenticated attacker could abuse improperly secured access to arbitrary files on the server (via /Electron/download directory traversal in conjunction with a path component that uses backslash characters), leading to cleartext credential disclosure. Afterwards, the authenticated attacker is able to upload a file that overwrites a 3CX service binary, leading to Remote Code Execution as NT AUTHORITY\SYSTEM on Windows installations. NOTE: this issue exists because of an incomplete fix for CVE-2022-48482.
Affected versions of Git have a vulnerability whereby Git can be tricked into sending private credentials to a host controlled by an attacker. Git uses external "credential helper" programs to store and retrieve passwords or other credentials from secure storage provided by the operating system. Specially-crafted URLs that contain an encoded newline can inject unintended values into the credential helper protocol stream, causing the credential helper to retrieve the password for one server (e.g., good.example.com) for an HTTP request being made to another server (e.g., evil.example.com), resulting in credentials for the former being sent to the latter. There are no restrictions on the relationship between the two, meaning that an attacker can craft a URL that will present stored credentials for any host to a host of their choosing. The vulnerability can be triggered by feeding a malicious URL to git clone. However, the affected URLs look rather suspicious; the likely vector would be through systems which automatically clone URLs not visible to the user, such as Git submodules, or package systems built around Git. The problem has been patched in the versions published on April 14th, 2020, going back to v2.17.x. Anyone wishing to backport the change further can do so by applying commit 9a6bbee (the full release includes extra checks for git fsck, but that commit is sufficient to protect clients against the vulnerability). The patched versions are: 2.17.4, 2.18.3, 2.19.4, 2.20.3, 2.21.2, 2.22.3, 2.23.2, 2.24.2, 2.25.3, 2.26.1.
Settings/network settings/wireless settings on the Alecto DVC-215IP camera version 63.1.1.173 and below shows the Wi-Fi passphrase hidden, but by editing/removing the style of the password field the password becomes visible which grants access to an internal network connected to the camera.
Bnmux BCW700J 5.20.7, BCW710J 5.30.6a, and BCW710J2 5.30.16 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
S-A WebSTAR DPC2100 v2.0.2r1256-060303 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
mplus CBC383Z CBC383Z_mplus_MDr026 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Jiuzhou BCM93383WRG 139.4410mp1.3921132mp1.899.004404.004 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
ARRIS DG950A 7.10.145 and DG950S 7.10.145.EURO devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Ubee DVW2108 6.28.1017 and DVW2110 6.28.2012 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Motorola SBG901 SBG901-2.10.1.1-GA-00-581-NOSH, SBG941 SBG941-2.11.0.0-GA-07-624-NOSH, and SVG1202 SVG1202-2.1.0.0-GA-14-LTSH devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
The implementation of POST with the username and password in the URL parameters exposed the credentials. More infomration is available in fineract jira issues 726 and 629.
Kaonmedia CG2001-AN22A 1.2.1, CG2001-UDBNA 3.0.8, and CG2001-UN2NA 3.0.8 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
A vulnerability was found in Portainer before 1.20.0. Portainer stores LDAP credentials, corresponding to a master password, in cleartext and allows their retrieval via API calls.
An issue was discovered on Xiaomi Mi A1 tissot_sprout:8.1.0/OPM1.171019.026/V9.6.4.0.ODHMIFE devices. They store cleartext Wi-Fi passwords in logcat during the process of setting up the phone as a hotspot.
Kibana versions 4.0 to 4.6, 5.0 to 5.6.12, and 6.0 to 6.4.2 contain an error in the way authorization credentials are used when generating PDF reports. If a report requests external resources plaintext credentials are included in the HTTP request that could be recovered by an external resource provider.
An issue was discovered in Descor Infocad FM before 3.1.0.0. An unauthenticated web service allows the retrieval of files on the web server and on reachable SMB servers.
In Puppet Discovery prior to 1.2.0, when running Discovery against Windows hosts, WinRM connections can fall back to using basic auth over insecure channels if a HTTPS server is not available. This can expose the login credentials being used by Puppet Discovery.
NEC Univerge Sv9100 WebPro 6.00.00 devices have Cleartext Password Storage in the Web UI.
Implemented protections on AWS credentials that were not properly protected.
Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) for SCCM and SCVMM versions prior to 7.2.1 contain a hard-coded cryptographic key vulnerability. A remote unauthenticated attacker may exploit this vulnerability to gain access to the appliance data for remotely managed devices.
The Olive Tree Ftp Server application 1.32 for Android has Insecure Data Storage because a username and password are stored in the /data/data/com.theolivetree.ftpserver/shared_prefs/com.theolivetree.ftpserver_preferences.xml file as the prefUsername and prefUserpass strings.
ubiQuoss Switch VP5208A creates a bcm_password file at /cgi-bin/ with the user credentials in cleartext when a failed login attempt occurs. The file can be reached via an HTTP request. The credentials can be used to access the system via SSH (or TELNET if it is enabled).
Copay Bitcoin Wallet version 5.01 to 5.1.0 included. contains a Other/Unknown vulnerability in wallet private key storage that can result in Users' private key can be compromised. . This attack appear to be exploitable via Affected version run the malicious code at startup . This vulnerability appears to have been fixed in 5.2.0 and later .
On Apache ShenYu versions 2.4.0 and 2.4.1, and endpoint existed that disclosed the passwords of all users. Users are recommended to upgrade to version 2.4.2 or later.
An issue was discovered in SMA Solar Technology products. Sniffed passwords from SMAdata2+ communication can be decrypted very easily. The passwords are "encrypted" using a very simple encryption algorithm. This enables an attacker to find the plaintext passwords and authenticate to the device. NOTE: the vendor reports that only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected