LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process.
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
The private key of the web server in Moxa MXview versions 2.8 and prior is able to be read and accessed via an HTTP GET request, which may allow a remote attacker to decrypt encrypted information.
An Information Exposure issue was discovered in ABB netCADOPS Web Application Version 3.4 and prior, netCADOPS Web Application Version 7.1 and prior, netCADOPS Web Application Version 7.2x and prior, netCADOPS Web Application Version 8.0 and prior, and netCADOPS Web Application Version 8.1 and prior. A vulnerability exists in the password entry section of netCADOPS Web Application that may expose critical database information.
In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner.
LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remote code on the server.
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data.
NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The device allows access to configuration files and profiles without authenticating the user.
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.
ABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonymous authentication, and specific key values within the eSOMS web.config file are present. Both conditions are required to exploit this vulnerability.
For Crestron TSW-X60 version prior to 2.001.0037.001 and MC3 version prior to 1.502.0047.001, The devices are shipped with authentication disabled, and there is no indication to users that they need to take steps to enable it. When compromised, the access to the CTP console is left open.
An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.
In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.
In ABB IP GATEWAY 3.39 and prior, some configuration files contain passwords stored in plain-text, which may allow an attacker to gain unauthorized access.
In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication.
IRC5 exposes an ftp server (port 21). Upon attempting to gain access you are challenged with a request of username and password, however you can input whatever you like. As long as the field isn't empty it will be accepted.
Moxa IKS and EDS store plaintext passwords, which may allow sensitive information to be read by someone with access to the device.
Moxa IKS and EDS do not implement sufficient measures to prevent multiple failed authentication attempts, which may allow an attacker to discover passwords via brute force attack.
An attacker can log into the local Niagara platform (Niagara AX Framework Versions 3.8 and prior or Niagara 4 Framework Versions 4.4 and prior) using a disabled account name and a blank password, granting the attacker administrator access to the Niagara system.
The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file. Path configuration in PB610 HMISimulator versions 2.8.0.424 and earlier potentially allows access to files outside of the working directory, thus potentially supporting unauthorized file access.
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.
NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The directory of the device is listed openly without authentication.
ABB has internally identified a vulnerability in the ABB VPNI feature of the S+ Control API component which may be used by several Symphony Plus products (e.g., S+ Operations, S+ Engineering and S+ Analyst) This issue affects Symphony Plus S+ Operations: from 3..0;0 through 3.3 SP1 RU4, from 2.1;0 through 2.1 SP2 RU3, from 2.0;0 through 2.0 SP6 TC6; Symphony Plus S+ Engineering: from 2.1 through 2.3 RU3; Symphony Plus S+ Analyst: from 7.0.0.0 through 7.2.0.2.
DeltaV Versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, and R5 is vulnerable due to improper path validation which may allow an attacker to replace executable files.
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.
Relative Path Traversal vulnerability in ABB Zenon 8.20 allows the user to access files on the Zenon system and user also can add own log messages and e.g., flood the log entries. An attacker who successfully exploit the vulnerability could access the Zenon runtime activities such as the start and stop of various activity and the last error code etc.
UPS Adapter CS141 before 1.90 allows Directory Traversal. An attacker with Admin or Engineer login credentials could exploit the vulnerability by manipulating variables that reference files and by doing this achieve access to files and directories outside the web root folder. An attacker may access arbitrary files and directories stored in the file system, but integrity of the files are not jeopardized as attacker have read access rights only.
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node.
In the ABB IDAL FTP server, an authenticated attacker can traverse to arbitrary directories on the hard disk with "CWD ../" and then use the FTP server functionality to download and upload files. An unauthenticated attacker can take advantage of the hardcoded or default credential pair exor/exor to become an authenticated attacker.
A path traversal vulnerability in Tridium Niagara AX Versions 3.8 and prior and Niagara 4 systems Versions 4.4 and prior installed on Microsoft Windows Systems can be exploited by leveraging valid platform (administrator) credentials.
Directory traversal vulnerability in clientarea.php in WHMCompleteSolution (WHMCS) 3.x.x allows remote attackers to read arbitrary files via an invalid action and a ../ (dot dot slash) in the templatefile parameter.
Directory traversal vulnerability in cgi-bin/koha/mainpage.pl in Koha 3.4 before 3.4.7 and 3.6 before 3.6.1, and LibLime Koha 4.2 and earlier allows remote attackers to read arbitrary files via a .. (dot dot) in the KohaOpacLanguage cookie to cgi-bin/opac/opac-main.pl, related to Output.pm.
Directory traversal vulnerability in Virtual Vertex Muster before 6.20 allows remote attackers to read arbitrary files via a \.. (backslash dot dot) in the URL.
Directory traversal vulnerability in the modURL function in instance.c in Weborf before 0.12.3 allows remote attackers to read arbitrary files via ..%2f sequences in a URI.
Directory traversal vulnerability in download.php in EnergyScripts (ES) Simple Download 1.0 allows remote attackers to read arbitrary files via a .. (dot dot) in the file parameter.
In CMS Made Simple 2.2.7, a Directory Traversal issue makes it possible to determine the existence of files and directories outside the web-site installation directory, and determine whether a file has contents matching a specified checksum. The attack uses an admin/checksum.php?__c= request.
Directory traversal vulnerability in ICONICS WebHMI 9 and earlier allows remote attackers to read configuration files, and consequently discover password hashes, via unspecified vectors.
Directory traversal vulnerability in chat/openattach.aspx in ReadyDesk 9.1 allows remote attackers to read arbitrary files via a .. (dot dot) in the SESID parameter in conjunction with a filename in the FNAME parameter.
Directory traversal vulnerability in assets/captcha/includes/alikon/playcode.php in the InterJoomla ArtForms (com_artforms) component 2.1b7.2 RC2 for Joomla! allows remote attackers to read arbitrary files via a .. (dot dot) in the l parameter.
Directory traversal vulnerability in Action View in Ruby on Rails before 3.2.22.2 and 4.x before 4.1.14.2 allows remote attackers to read arbitrary files by leveraging an application's unrestricted use of the render method and providing a .. (dot dot) in a pathname. NOTE: this vulnerability exists because of an incomplete fix for CVE-2016-0752.
Directory traversal vulnerability in lastlines.cgi for Last Lines 2.0 allows remote attackers to read arbitrary files via '..' sequences in the $error_log variable.
Directory traversal vulnerability in the web server in Cogent DataHub 7.1.1.63 and earlier allows remote attackers to read arbitrary files via a ..\ (dot dot backslash) in an HTTP request.
In Gxlcms QY v1.0.0713, Lib\Lib\Action\Admin\TplAction.class.php allows remote attackers to read any file via a modified pathname in an Admin-Tpl request, as demonstrated by use of '|' instead of '/' as a directory separator, in conjunction with a ".." sequence.
Directory traversal vulnerability in FileDownload.jsp in ManageEngine ServiceDesk Plus 8.0 before Build 8012 allows remote attackers to read arbitrary files via unspecified vectors.
Http4s is a Scala interface for HTTP services. `StaticFile.fromUrl` can leak the presence of a directory on a server when the `URL` scheme is not `file://`, and the URL points to a fetchable resource under its scheme and authority. The function returns `F[None]`, indicating no resource, if `url.getFile` is a directory, without first checking the scheme or authority of the URL. If a URL connection to the scheme and URL would return a stream, and the path in the URL exists as a directory on the server, the presence of the directory on the server could be inferred from the 404 response. The contents and other metadata about the directory are not exposed. This affects http4s versions: 0.21.7 through 0.21.23, 0.22.0-M1 through 0.22.0-M8, 0.23.0-M1, and 1.0.0-M1 through 1.0.0-M22. The [patch](https://github.com/http4s/http4s/commit/52e1890665410b4385e37b96bc49c5e3c708e4e9) is available in the following versions: v0.21.24, v0.22.0-M9, v0.23.0-M2, v1.0.0-M23. As a workaround users can avoid calling `StaticFile.fromUrl` with non-file URLs.
Directory traversal vulnerability in the HTTP interface in AXIGEN Mail Server 7.4.1 for Windows allows remote attackers to read arbitrary files via a %5C (encoded backslash) in the URL.
The default installation of Apache before 1.3.19 allows remote attackers to list directories instead of the multiview index.html file via an HTTP request for a path that contains many / (slash) characters, which causes the path to be mishandled by (1) mod_negotiation, (2) mod_dir, or (3) mod_autoindex.
Directory traversal vulnerability in the AWDwall (com_awdwall) component 1.5.4 for Joomla! allows remote attackers to read arbitrary files via a .. (dot dot) in the controller parameter to index.php.
Directory traversal vulnerability in help/frameRight.php in Elastix 1.6.0 allows remote attackers to read arbitrary files via a .. (dot dot) in the id_nodo parameter. NOTE: the provenance of this information is unknown; the details are obtained solely from third party information.