In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request.
A CWE-807: Reliance on Untrusted Inputs in a Security Decision vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause invalid information displayed in Unity Pro software.
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.
A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller.
A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table.
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.
An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted request to the controller over HTTP.
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
A CWE-200: Information Exposure vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow attacker to obtain private keys.
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file.
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.
An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information.
Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified vectors.
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX.
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation.
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text.
A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40. which could cause a Denial Of Service when using a Telnet connection.
An issue was discovered in Foxit Reader and PhantomPDF before 9.2. It allows NTLM credential theft via a GoToE or GoToR action.
An attacker can decrypt the Ovarro TBox login password by communication capture and brute force attacks.
NET&SYS MNG2120J 5.76.1006c and MNG6300 5.83.6305jrc2 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
D-Link DCM-604 DCM604_C1_ViaCabo_1.04_20130606 and DCM-704 EU_DCM-704_1.10 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Technicolor TC7110.AR STD3.38.03 devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.2863.205.10.1.30.4.1.14.1.3.32 and iso.3.6.1.4.1.2863.205.10.1.30.4.2.4.1.2.32 SNMP requests.
mplus CBC383Z CBC383Z_mplus_MDr026 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Technicolor CWA0101 CWA0101E-A23E-c7000r5712-170315-SKC devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.4413.2.2.2.1.5.4.1.14.1.3.10001 and 1.3.6.1.4.1.4413.2.2.2.1.18.1.2.3.4.1.2.10001 SNMP requests.
iNovo Broadband IB-8120-W21 139.4410mp1.004200.002 and IB-8120-W21E1 139.4410mp1.3921132mp1.899.004404.004 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Kaonmedia CG2001-AN22A 1.2.1, CG2001-UDBNA 3.0.8, and CG2001-UN2NA 3.0.8 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
Jiuzhou BCM93383WRG 139.4410mp1.3921132mp1.899.004404.004 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Technicolor TC7200.TH2v2 SC05.00.22 devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.2863.205.10.1.30.4.1.14.1.3.32 and iso.3.6.1.4.1.2863.205.10.1.30.4.2.4.1.2.32 SNMP requests.
ARRIS DG950A 7.10.145 and DG950S 7.10.145.EURO devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
SuiteCRM 7.10.x prior to 7.10.21 and 7.11.x prior to 7.11.9 mishandles API access tokens and credentials.
CastleNet CBV38Z4EC 125.553mp1.39219mp1.899.007, CBV38Z4ECNIT 125.553mp1.39219mp1.899.005ITT, CBW383G4J 37.556mp5.008, and CBW38G4J 37.553mp1.008 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
D-Link DCM-604 DCM604_C1_ViaCabo_1.04_20130606 and DCM-704 EU_DCM-704_1.10 devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.4413.2.2.2.1.5.4.1.14.1.3.32 and iso.3.6.1.4.1.4413.2.2.2.1.5.4.2.4.1.2.32 SNMP requests.
Technicolor TC7110.B STC8.62.02 devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.2863.205.10.1.30.4.1.14.1.3.32 and iso.3.6.1.4.1.2863.205.10.1.30.4.2.4.1.2.32 SNMP requests.
Bnmux BCW700J 5.20.7, BCW710J 5.30.6a, and BCW710J2 5.30.16 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
TEKNOTEL CBW700N 81.447.392110.729.024 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
NETWAVE MNG6200 C4835805jrc12FU121413.cpr devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.