A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
An issue was discovered on Shenzhen Coship WM3300 WiFi Router 5.0.0.55 devices. The password reset functionality of the Wireless SSID doesn't require any type of authentication. By making a POST request to the regx/wireless/wl_security_2G.asp URI, the attacker can change the password of the Wi-FI network.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
ONTAP Select Deploy administration utility versions 2.12 & 2.12.1 ship with an HTTP service bound to the network allowing unauthenticated remote attackers to perform administrative actions.
ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
It was found that default configuration of Heketi does not require any authentication potentially exposing the management interface to misuse. This isue only affects heketi as shipped with Openshift Container Platform 3.11.
A broken access control vulnerability found in Advan VD-1 firmware version 230 leads to insecure ADB service. An attacker can send a POST request to cgibin/AdbSetting.cgi to enable ADB without any authentication then take the compromised device as a relay or to install mining software.
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
Systematic IRIS WebForms 5.4 and its functionalities can be accessed and used without any form of authentication.
The RSA Identity Governance and Lifecycle and RSA Via Lifecycle and Governance products prior to 7.1.1 P03 contain an Improper Authentication vulnerability. A Java JMX agent running on the remote host is configured with plain text password authentication. An unauthenticated remote attacker can connect to the JMX agent and monitor and manage the Java application.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the Script Parser AddOn through 1.8 installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi script, which executes TCL script content from an HTTP POST request.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the HM-Print AddOn through 1.2a installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi and exec1.cgi scripts, which execute TCL script content from an HTTP POST request.
wan.htm page on Zyxel NBG-418N v2 with firmware version V1.00(AARP.9)C0 can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify data fields of the page.
The nd-restaurant-reservations plugin before 1.5 for WordPress has no requirement for nd_rst_import_settings_php_function authentication.
eQ-3 Homematic CCU2 before 2.47.18 and CCU3 before 3.47.18 allow Remote Code Execution by unauthenticated attackers with access to the web interface via an HTTP POST request to certain URLs related to the ReGa core process.
Intesync Solismed 3.3sp has Incorrect Access Control.
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.
An issue was discovered in Zoho ManageEngine OpManager in builds before 14310. One can bypass the user password requirement and execute commands on the server. The "username+'@opm' string is used for the password. For example, if the username is admin, the password is admin@opm.
HiNet GPON firmware version < I040GWR190731 allows an attacker login to device without any authentication.
The querier component in Grafana Enterprise Logs 1.1.x through 1.3.x before 1.4.0 does not require authentication when X-Scope-OrgID is used. Versions 1.2.1, 1.3.1, and 1.4.0 contain the bugfix. This affects -auth.type=enterprise in microservices mode
Directus 7 API before 2.2.2 has insufficient anti-automation, as demonstrated by lack of a CAPTCHA in core/Directus/Services/AuthService.php and endpoints/Auth.php.
In mintplex-labs/anything-llm v1.5.11 desktop version for Windows, the application opens server port 3001 on 0.0.0.0 with no authentication by default. This vulnerability allows an attacker to gain full backend access, enabling them to perform actions such as deleting all data from the workspace.
Super Micro SuperDoctor 5, when restrictions are not implemented in agent.cfg, allows remote attackers to execute arbitrary commands via NRPE.
An issue was discovered in ONAP HOLMES before Dublin. By accessing port 9202 of dep-holmes-engine-mgmt pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4001 of demo-sdc-sdc-onboarding-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 6000 of demo-sdc-sdc-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in upgrade_htmls.cgi on VStarcam 100T (C7824WIP) KR75.8.53.20 and 200V (C38S) KR203.18.1.20 devices. The web service, network, and account files can be manipulated through a web UI firmware update without any authentication. The attacker can achieve access to the device through a manipulated web UI firmware update.
An issue was discovered in ONAP SDC through Dublin. By accessing port 7000 of demo-sdc-sdc-wfd-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in upgrade_firmware.cgi on VStarcam 100T (C7824WIP) CH-sys-48.53.75.119~123 and 200V (C38S) CH-sys-48.53.203.119~123 devices. A remote command can be executed through a system firmware update without authentication. The attacker can modify the files within the internal firmware or even steal account information by executing a command.
In ONAP DCAE through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 7001 of demo-sdc-sdc-wfd-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
Anviz access control devices allow remote attackers to issue commands without a password.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4000 of demo-sdc-sdc-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in Squid through 4.7. When handling requests from users, Squid checks its rules to see if the request should be denied. Squid by default comes with rules to block access to the Cache Manager, which serves detailed server information meant for the maintainer. This rule is implemented via url_regex. The handler for url_regex rules URL decodes an incoming request. This allows an attacker to encode their URL to bypass the url_regex check, and gain access to the blocked resource.
An issue was discovered on D-Link DIR-600M 3.02, 3.03, 3.04, and 3.06 devices. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
In ONAP Logging through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
RedwoodHQ 2.5.5 does not require any authentication for database operations, which allows remote attackers to create admin users via a con.automationframework users insert_one call.
An Incorrect Access Control vulnerability was found in Wikimedia MediaWiki 1.27.0 through 1.32.1. Directly POSTing to Special:ChangeEmail would allow for bypassing re-authentication, allowing for potential account takeover.
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Anviz Global M3 Outdoor RFID Access Control executes any command received from any source. No authentication/encryption is done. Attackers can fully interact with the device: for example, send the "open door" command, download the users list (which includes RFID codes and passcodes in cleartext), or update/create users. The same attack can be executed on a local network and over the internet (if the device is exposed on a public IP address).
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.15 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via the user authentication dialogue, aka HMCCU-153. This leads to automatic login as admin.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/form2userconfig.cgi to edit the system account without authentication.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/setSysAdm to edit the web or system account without authentication.
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the RemoteApi account, aka HMCCU-154. This leads to automatic login as admin.
SAP Cloud Connector, before version 2.11.3, does not perform any authentication checks for functionalities that require user identity.
Under certain circumstances, SAP HANA Extended Application Services, advanced model (XS advanced) does not perform authentication checks properly for XS advanced platform and business users. Fixed in 1.0.97 to 1.0.99 (running on SAP HANA 1 or SAP HANA 2 SPS0 (second S stands for stack)).