Prisma Industriale Checkweigher PrismaWEB 1.21 allows remote attackers to discover the hardcoded prisma password for the prismaweb account by reading user/scripts/login_par.js.
The Integrated User Firewall (UserFW) feature was introduced in Junos OS version 12.1X47-D10 on the Juniper SRX Series devices to provide simple integration of user profiles on top of the existing firewall polices. As part of an internal security review of the UserFW services authentication API, hardcoded credentials were identified and removed which can impact both the SRX Series device, and potentially LDAP and Active Directory integrated points. An attacker may be able to completely compromise SRX Series devices, as well as Active Directory servers and services. When Active Directory is compromised, it may allow access to user credentials, workstations, servers performing other functions such as email, database, etc. Inter-Forest Active Directory deployments may also be at risk as the attacker may gain full administrative control over one or more Active Directories depending on the credentials supplied by the administrator of the AD domains and SRX devices performing integrated authentication of users, groups and devices. To identify if your device is potentially vulnerable to exploitation, check to see if the service is operating; from CLI review the following output: root@SRX-Firewall# run show services user-identification active-directory-access domain-controller status extensive A result of "Status: Connected" will indicate that the service is active on the device. To evaluate if user authentication is occurring through the device: root@SRX-Firewall# run show services user-identification active-directory-access active-directory-authentication-table all Next review the results to see if valid users and groups are returned. e.g. Domain: juniperlab.com Total entries: 3 Source IP Username groups state 172.16.26.1 administrator Valid 192.168.26.2 engg01 engineers Valid 192.168.26.3 guest01 guests Valid Domain: NULL Total entries: 8 Source IP Username groups state 192.168.26.4 Invalid 192.168.26.5 Invalid This will also indicate that Valid users and groups are authenticating through the device. Affected releases are Juniper Networks Junos OS 12.3X48 from 12.3X48-D30 and prior to 12.3X48-D35 on SRX series; 15.1X49 from 15.1X49-D40 and prior to 15.1X49-D50 on SRX series. Devices on any version of Junos OS 12.1X46, or 12.1X47 are unaffected by this issue.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded System Passwords that provide shell access.
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.
A use of hard-coded credentials (CWE-798) vulnerability in FortiPortal versions 5.2.5 and below, 5.3.5 and below, 6.0.4 and below, versions 5.1.x and 5.0.x may allow a remote and unauthenticated attacker to execute unauthorized commands as root by uploading and deploying malicious web application archive files using the default hard-coded Tomcat Manager username and password.
An issue was discovered on VOBOT CLOCK before 0.99.30 devices. An SSH server exists with a hardcoded vobot account that has root access.
An issue was discovered in the MBeans Server in Wowza Streaming Engine before 4.7.1. The file system may be read and written to via JMX using the default JMX credentials (remote code execution may be possible as well).
The ZyXEL P660HN-T1A v2 TCLinux Fw #7.3.37.6 router distributed by TrueOnline has three user accounts with default passwords, including two hardcoded service accounts: one with the username true and password true, and another with the username supervisor and password zyad1234. These accounts can be used to login to the web interface, exploit authenticated command injections, and change router settings for malicious purposes.
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices have a hardcoded password of admin for the admin account, a hardcoded password of support for the support account, and a hardcoded password of user for the user account.
Versions of DocuTrac QuicDoc and Office Therapy that ship with DTISQLInstaller.exe version 1.6.4.0 and prior contain three credentials with known passwords: QDMaster, OTMaster, and sa.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
Meross MSS110 devices before 1.1.24 contain a TELNET listener providing access for an undocumented admin account with a blank password.
BB-ESWGP506-2SFP-T versions 1.01.09 and prior is vulnerable due to the use of hard-coded credentials, which may allow an attacker to gain unauthorized access and permit the execution of arbitrary code on the BB-ESWGP506-2SFP-T (versions 1.01.01 and prior).
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.
D-Link DIR-620 devices, with a certain Rostelekom variant of firmware 1.0.37, have a hardcoded rostel account, which makes it easier for remote attackers to obtain access via a TELNET session.
In the web server on D-Link DIR-620 devices with a certain customized (by ISP) variant of firmware 1.0.3, 1.0.37, 1.3.1, 1.3.3, 1.3.7, 1.4.0, and 2.0.22, there is a hardcoded password of anonymous for the admin account.
MASTER IPCAMERA01 3.3.4.2103 devices have a hardcoded password of cat1029 for the root account.
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.
Zivif PR115-204-P-RS V2.3.4.2103 web cameras contain a hard-coded cat1029 password for the root user. The SONIX operating system's setup renders this password unchangeable and it can be used to access the device via a TELNET session.
The presence of a hardcoded account in Fortinet FortiWLC 7.0.11 and earlier allows attackers to gain unauthorized read/write access via a remote shell.
The presence of a hardcoded account in Fortinet FortiWLC 8.3.3 allows attackers to gain unauthorized read/write access via a remote shell.
Swann SWWHD-INTCAM-HD devices have the twipc root password, leading to FTP access as root. NOTE: all affected customers were migrated by 2020-08-31.
D-Link COVR-2600R and COVR-3902 Kit before 1.01b05Beta01 use hardcoded credentials for telnet connection, which allows unauthenticated attackers to gain privileged access to the router, and to extract sensitive data or modify the configuration.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The admin account has a blank password.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The CGIProxy.fcgi?cmd=setTelnetSwitch feature is authorized for the root user with a password of toor.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. There is a hardcoded Ak47@99 password for the factory~ account.
A hidden backdoor on PATLITE NH-FB Series devices with firmware version 1.45 or earlier, NH-FV Series devices with firmware version 1.10 or earlier, and NBM Series devices with firmware version 1.09 or earlier allow attackers to enable an SSH daemon via the "kankichi" or "kamiyo4" password to the _secret1.htm URI. Subsequently, the default password of root for the root account allows an attacker to conduct remote code execution and as a result take over the system.
Deltek Vision 7.x before 7.6 permits the execution of any attacker supplied SQL statement through a custom RPC over HTTP protocol. The Vision system relies on the client binary to enforce security rules and integrity of SQL statements and other content being sent to the server. Client HTTP calls can be manipulated by one of several means to execute arbitrary SQL statements (similar to SQLi) or possibly have unspecified other impact via this custom protocol. To perform these attacks an authenticated session is first required. In some cases client calls are obfuscated by encryption, which can be bypassed due to hard-coded keys and an insecure key rotation protocol. Impacts may include remote code execution in some deployments; however, the vendor states that this cannot occur when the installation documentation is heeded.
Hardcoded credentials in the Ricoh myPrint application 2.9.2.4 for Windows and 2.2.7 for Android give access to any externally disclosed myPrint WSDL API, as demonstrated by discovering API secrets of related Google cloud printers, encrypted passwords of mail servers, and names of printed files.
NUUO CMS all versions 3.1 and prior, The application creates default accounts that have hard-coded passwords, which could allow an attacker to gain privileged access.
The Oracle WebCenter Interaction 10.3.3 search service queryd.exe binary is compiled with the i1g2s3c4 hardcoded password. Authentication to the Oracle WCI search service uses this hardcoded password and cannot be customised by customers. An adversary able to access this service over a network could perform search queries to extract large quantities of sensitive information from the WCI installation. NOTE: this CVE is assigned by MITRE and isn't validated by Oracle because Oracle WebCenter Interaction Portal is out of support.
GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
An issue was discovered on Wireless IP Camera 360 devices. A root account with a known SHA-512 password hash exists, which makes it easier for remote attackers to obtain administrative access via a TELNET session.
POSIM EVO 15.13 for Windows includes hardcoded database credentials for the "root" database user. "root" access to POSIM EVO's database may result in a breach of confidentiality, integrity, or availability or allow for attackers to remotely execute code on associated POSIM EVO clients.
Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers' installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
Logitech Harmony Hub before version 4.15.206 contained two hard-coded accounts in the XMPP server that gave remote users access to the local API.
Backup archives were found to be encrypted with a static password across different installations, which suggest the same password may be used in all virtual appliance instances of Trend Micro Deep Discovery Director 1.1.
SV3C L-SERIES HD CAMERA V2.3.4.2103-S50-NTD-B20170508B and V2.3.4.2103-S50-NTD-B20170823B devices have a Hard-coded Password.
Harmonic NSG 9000 devices have a default password of nsgadmin for the admin account, a default password of nsgguest for the guest account, and a default password of nsgconfig for the config account.
The demo feature in Oracle GlassFish Open Source Edition 5.0 has TCP port 7676 open by default with a password of admin for the admin account. This allows remote attackers to obtain potentially sensitive information, perform database operations, or manipulate the demo via a JMX RMI session, aka a "jmx_rmi remote monitoring and control problem." NOTE: this is not an Oracle supported product.
A vulnerability in the install function of Cisco Prime Collaboration Provisioning (PCP) could allow an unauthenticated, remote attacker to access the administrative web interface using a default hard-coded username and password that are used during install. The vulnerability is due to a hard-coded password that, in some cases, is not replaced with a unique password. A successful exploit could allow the attacker to access the administrative web interface with administrator-level privileges.
A vulnerability in the Cisco Small Business Switches software could allow an unauthenticated, remote attacker to bypass the user authentication mechanism of an affected device. The vulnerability exists because under specific circumstances, the affected software enables a privileged user account without notifying administrators of the system. An attacker could exploit this vulnerability by using this account to log in to an affected device and execute commands with full admin rights. Cisco has not released software updates that address this vulnerability. This advisory will be updated with fixed software information once fixed software becomes available. There is a workaround to address this vulnerability.
A vulnerability in Cisco Video Surveillance Manager (VSM) Software running on certain Cisco Connected Safety and Security Unified Computing System (UCS) platforms could allow an unauthenticated, remote attacker to log in to an affected system by using the root account, which has default, static user credentials. The vulnerability is due to the presence of undocumented, default, static user credentials for the root account of the affected software on certain systems. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
IBM dashDB Local uses hard-coded credentials that could allow a remote attacker to gain access to the Docker container or database.
A hard-coded cryptographic key vulnerability was identified in Red Lion Controls Sixnet-Managed Industrial Switches running firmware Version 5.0.196 and Stride-Managed Ethernet Switches running firmware Version 5.0.190. Vulnerable versions of Stride-Managed Ethernet switches and Sixnet-Managed Industrial switches use hard-coded HTTP SSL/SSH keys for secure communication. Because these keys cannot be regenerated by users, all products use the same key. The attacker could disrupt communication or compromise the system. CVSS v3 base score: 10, CVSS vector string: (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). Red Lion Controls recommends updating to SLX firmware Version 5.3.174.
Django 1.8.x before 1.8.16, 1.9.x before 1.9.11, and 1.10.x before 1.10.3 use a hardcoded password for a temporary database user created when running tests with an Oracle database, which makes it easier for remote attackers to obtain access to the database server by leveraging failure to manually specify a password in the database settings TEST dictionary.
An exploitable Use of Hard-coded Credentials vulnerability exists in the Moxa AWK-3131A Wireless Access Point running firmware 1.1. The device operating system contains an undocumented, privileged (root) account with hard-coded credentials, giving attackers full control of affected devices.