A stack buffer overflow in webs in Ruckus Wireless Unleashed through 200.7.10.102.92 allows a remote attacker to execute code via an unauthenticated crafted HTTP request. This affects C110, E510, H320, H510, M510, R320, R310, R500, R510 R600, R610, R710, R720, R750, T300, T301n, T301s, T310c, T310d, T310n, T310s, T610, T710, and T710s devices.
emfd/libemf in Ruckus Wireless Unleashed through 200.7.10.102.92 allows a remote attacker to achieve command injection via a crafted HTTP request. This affects C110, E510, H320, H510, M510, R320, R310, R500, R510 R600, R610, R710, R720, R750, T300, T301n, T301s, T310c, T310d, T310n, T310s, T610, T710, and T710s devices.
rkscli in Ruckus Wireless Unleashed through 200.7.10.92 allows a remote attacker to achieve command injection and jailbreak the CLI via a crafted CLI command. This affects C110, E510, H320, H510, M510, R320, R310, R500, R510 R600, R610, R710, R720, R750, T300, T301n, T301s, T310c, T310d, T310n, T310s, T610, T710, and T710s devices.
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.27 and 200.18.7.1.323, and in Ruckus ZoneDirector prior to 10.5.1.0.282, where a path-traversal flaw in the web interface lets the server execute attacker-supplied EJS templates outside permitted directories, allowing a remote unauthenticated attacker who can upload a template (e.g., via FTP) to escalate privileges and run arbitrary template code on the controller.
emfd in Ruckus Wireless Unleashed through 200.7.10.102.64 allows remote attackers to execute OS commands via a POST request with the attribute xcmd=get-platform-depends to admin/_cmdstat.jsp via the uploadFile attribute.
A stack-based buffer overflow in zap_parse_args in zap.c in zap in Ruckus Unleashed through 200.7.10.102.64 allows remote code execution via an unauthenticated HTTP request.
AjaxRestrictedCmdStat in zap in Ruckus Wireless Unleashed through 200.7.10.102.64 allows remote code execution via a POST request that uses tools/_rcmdstat.jsp to write to a specified filename.
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, where the functions `stamgr_cfg_adpt_addStaFavourite` and `stamgr_cfg_adpt_addStaIot` pass a client hostname directly to snprintf as the format string. A remote attacker can exploit this flaw either by sending a crafted request to the authenticated endpoint `/admin/_conf.jsp`, or without authentication and without direct network access to the controller by spoofing the MAC address of a favourite station and embedding malicious format specifiers in the DHCP hostname field, resulting in unauthenticated format-string processing and arbitrary code execution on the controller.
Ruckus Wireless Admin through 10.4 allows Remote Code Execution via an unauthenticated HTTP GET Request, as demonstrated by a /forms/doLogin?login_username=admin&password=password$(curl substring.
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to exploit the official image signature to force injection unauthorized image signature.
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to bypass firmware image bad md5 checksum failed error.
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to switch completely to unauthorized image to be Boot as primary verified image.
emfd in Ruckus Wireless Unleashed through 200.7.10.102.64 allows remote attackers to execute OS commands via a POST request with the attribute xcmd=packet-capture to admin/_cmdstat.jsp via the mac attribute.
emfd in Ruckus Wireless Unleashed through 200.7.10.102.64 allows remote attackers to execute OS commands via a POST request with the attribute xcmd=spectra-analysis to admin/_cmdstat.jsp via the mac attribute.
emfd in Ruckus Wireless Unleashed through 200.7.10.102.64 allows remote attackers to execute OS commands via a POST request with the attribute xcmd=import-category to admin/_cmdstat.jsp via the uploadFile attribute.
Insecure permissions in emfd/libemf in Ruckus Wireless Unleashed through 200.7.10.102.92 allow a remote attacker to overwrite admin credentials via an unauthenticated crafted HTTP request. This affects C110, E510, H320, H510, M510, R320, R310, R500, R510 R600, R610, R710, R720, R750, T300, T301n, T301s, T310c, T310d, T310n, T310s, T610, T710, and T710s devices.
patrickfuller camp up to and including commit bbd53a256ed70e79bd8758080936afbf6d738767 is vulnerable to Incorrect Access Control. Access to the password.txt file is not properly restricted as it is in the root directory served by StaticFileHandler and the Tornado rule to throw a 403 error when password.txt is accessed can be bypassed. Furthermore, it is not necessary to crack the password hash to authenticate with the application because the password hash is also used as the cookie secret, so an attacker can generate his own authentication cookie.
rpc.py through 0.6.0 allows Remote Code Execution because an unpickle occurs when the "serializer: pickle" HTTP header is sent. In other words, although JSON (not Pickle) is the default data format, an unauthenticated client can cause the data to be processed with unpickle.
Dell PowerScale OneFS, versions 9.0.0 up to and including 9.1.0.19, 9.2.1.12, 9.3.0.6, and 9.4.0.3, contain an unprotected transport of credentials vulnerability. A malicious unprivileged network attacker could potentially exploit this vulnerability, leading to full system compromise.
An issue was discovered in Gazie 7.32. A successful installation does not remove or block (or in any other way prevent use of) its own file /setup/install/setup.php, meaning that anyone can request it without authentication. This file allows arbitrary PHP file inclusion via a hidden_req POST parameter.
An issue was discovered in Nitrokey FIDO U2F firmware through 1.1. Communication between the microcontroller and the secure element transmits credentials in plain. This allows an adversary to eavesdrop the communication and derive the secrets stored in the microcontroller. As a result, the attacker is able to arbitrarily manipulate the firmware of the microcontroller.
The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running these exact default credentials and consider thereby this an exposure that should be mitigated. Moreover, future deployments should consider that these defaults should be forbidden (user should be forced to change them).
An improper access control vulnerability was identified in the GitHub Enterprise Server API that allowed an organization member to escalate permissions and gain access to unauthorized repositories within an organization. This vulnerability affected all versions of GitHub Enterprise Server prior to 2.21 and was fixed in 2.20.9, 2.19.15, and 2.18.20. This vulnerability was reported via the GitHub Bug Bounty program.
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
Marval MSM v14.19.0.12476 has a 0-Click Account Takeover vulnerability which allows an attacker to change any user's password in the organization, this means that the user can also escalate achieve Privilege Escalation by changing the administrator password.
The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device.
The sensitive information of webcam device is not properly protected. Remote attackers can unauthentically grant administrator’s credential and further control the devices.
Insufficiently protected credentials for Intel(R) AMT and Intel(R) Standard Manageability may allow an unauthenticated user to potentially enable information disclosure and escalation of privilege via network access.
H3C ER8300G2-X is vulnerable to Incorrect Access Control. The password for the router's management system can be accessed via the management system page login interface.
Information Exposure vulnerability in eXtplorer makes the /usr/ and /etc/extplorer/ system directories world-accessible over HTTP. Introduced in the Makefile patch file debian/patches/debian-changes-2.1.0b6+dfsg-1 or debian/patches/adds-a-makefile.patch, this can lead to data leakage, information disclosure and potentially remote code execution on the web server. This issue affects all versions of eXtplorer in Ubuntu and Debian
ONTAP Select Deploy administration utility versions 2.2 through 2.12.1 transmit credentials in plaintext.
An issue was discovered in the 3CX Phone System Management Console prior to version 18 Update 3 FINAL. An unauthenticated attacker could abuse improperly secured access to arbitrary files on the server (via /Electron/download directory traversal in conjunction with a path component that uses backslash characters), leading to cleartext credential disclosure. Afterwards, the authenticated attacker is able to upload a file that overwrites a 3CX service binary, leading to Remote Code Execution as NT AUTHORITY\SYSTEM on Windows installations. NOTE: this issue exists because of an incomplete fix for CVE-2022-48482.
This affects the package cesanta/mongoose before 7.6. The unsafe handling of file names during upload using mg_http_upload() method may enable attackers to write files to arbitrary locations outside the designated target folder.
IBM Rational ClearCase 1.0.0.0 GIT connector does not sufficiently protect the document database password. An attacker could obtain the password and gain unauthorized access to the document database. IBM X-Force ID: 156583.
An issue in PDQ Smart Deploy V.3.0.2040 allows an attacker to escalate privileges via the Credential encryption routines in SDCommon.dll
All versions up to V4.01.01.02 of ZTE ZXCLOUD GoldenData VAP product have encryption problems vulnerability. Attackers could sniff unencrypted account and password through the network for front-end system access.
A vulnerability classified as critical was found in SourceCodester Client Database Management System 1.0. This vulnerability affects unknown code. The manipulation leads to exposure of information through directory listing. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Unprotected Storage of Credentials vulnerability in McAfee Advanced Threat Defense (ATD) prior to 4.8 allows local attacker to gain access to the root password via accessing sensitive files on the system. This was originally published with a CVSS rating of High, further investigation has resulted in this being updated to Critical. The root password is common across all instances of ATD prior to 4.8. See the Security bulletin for further details
An attacker can manipulate file upload params to enable paths traversal and under some circumstances this can lead to uploading a malicious file which can be used to perform Remote Code Execution. Users are recommended to upgrade to versions Struts 2.5.33 or Struts 6.3.0.2 or greater to fix this issue.
D-Link DIR-100 4.03B07: security bypass via an error in the cliget.cgi script
iTop is an IT service management platform. Files from the `env-production` folder can be retrieved even though they should have restricted access. Hopefully, there is no sensitive files stored in that folder natively, but there could be from a third-party module. The `pages/exec.php` script as been fixed to limit execution of PHP files only. Other file types won't be retrieved and exposed. The vulnerability is fixed in 2.7.10, 3.0.4, 3.1.1, and 3.2.0.
STMicroelectronics SPC58 is vulnerable to Missing Protection Mechanism for Alternate Hardware Interface. Code running as Supervisor on the SPC58 PowerPC microcontrollers may disable the System Memory Protection Unit and gain unabridged read/write access to protected assets.
Blaauw Remote Kiln Control through v3.00r4 allows an unauthenticated attacker to access MySQL credentials in cleartext in /engine/db.inc, /lang/nl.bak, or /lang/en.bak.
NVIDIA DGX H100 BMC contains a vulnerability in IPMI, where an attacker may cause insufficient protection of credentials. A successful exploit of this vulnerability may lead to code execution, denial of service, information disclosure, and escalation of privileges.
admin_news.php in Archilles Newsworld up to 1.3.0 allows attackers to bypass authentication by obtaining the password hash for another user, for example through another Newsworld vulnerability, and specifying the hash in the pwd argument.
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on the RTU. An unauthenticated user can obtain the exposed password credentials to gain access to the following services: DDNS service, Mobile Network Provider, and OpenVPN service.
The HTTP client in Gradle before 5.6 sends authentication credentials originally destined for the configured host. If that host returns a 30x redirect, Gradle also sends those credentials to all subsequent hosts that the request redirects to. This is similar to CVE-2018-1000007.
Brocade SANnav versions before v2.1.0, contain a Plaintext Password Storage vulnerability.