Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2019-6852

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-20 Nov, 2019 | 22:01
Updated At-04 Aug, 2024 | 20:31
Rejected At-
Credits

A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:20 Nov, 2019 | 22:01
Updated At:04 Aug, 2024 | 20:31
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.

Affected Products
Vendor
Schneider Electric SESchneider Electric
Product
Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions)
Versions
Affected
  • Modicon Controllers (M340 CPUs
  • M340 communication modules
  • Premium CPUs
  • Premium communication modules
  • Quantum CPUs
  • Quantum communication modules - see security notification for specific versions)
Problem Types
TypeCWE IDDescription
CWECWE-200CWE-200: Information Exposure
Type: CWE
CWE ID: CWE-200
Description: CWE-200: Information Exposure
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02/
x_refsource_CONFIRM
Hyperlink: https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02/
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02/
x_refsource_CONFIRM
x_transferred
Hyperlink: https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02/
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:20 Nov, 2019 | 22:15
Updated At:22 Nov, 2019 | 15:04

A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary2.05.0MEDIUM
AV:N/AC:L/Au:N/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Type: Primary
Version: 2.0
Base score: 5.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:N/C:P/I:N/A:N
CPE Matches

Schneider Electric SE
schneider-electric
>>bmx_p34x_firmware>>*
cpe:2.3:o:schneider-electric:bmx_p34x_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmx_p34x>>-
cpe:2.3:h:schneider-electric:bmx_p34x:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmx_noe_0100_firmware>>*
cpe:2.3:o:schneider-electric:bmx_noe_0100_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmx_noe_0100>>-
cpe:2.3:h:schneider-electric:bmx_noe_0100:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmx_noe_0110_firmware>>*
cpe:2.3:o:schneider-electric:bmx_noe_0110_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmx_noe_0110>>-
cpe:2.3:h:schneider-electric:bmx_noe_0110:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmx_noc_0401_firmware>>*
cpe:2.3:o:schneider-electric:bmx_noc_0401_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmx_noc_0401>>-
cpe:2.3:h:schneider-electric:bmx_noc_0401:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsx_p57x_firmware>>*
cpe:2.3:o:schneider-electric:tsx_p57x_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsx_p57x>>-
cpe:2.3:h:schneider-electric:tsx_p57x:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsx_ety_x103_firmware>>*
cpe:2.3:o:schneider-electric:tsx_ety_x103_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsx_ety_x103>>-
cpe:2.3:h:schneider-electric:tsx_ety_x103:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140_cpu6x_firmware>>*
cpe:2.3:o:schneider-electric:140_cpu6x_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140_cpu6x>>-
cpe:2.3:h:schneider-electric:140_cpu6x:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140_noe_771x1_firmware>>*
cpe:2.3:o:schneider-electric:140_noe_771x1_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140_noe_771x1>>-
cpe:2.3:h:schneider-electric:140_noe_771x1:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140_noc_78x00_firmware>>*
cpe:2.3:o:schneider-electric:140_noc_78x00_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140_noc_78x00>>-
cpe:2.3:h:schneider-electric:140_noc_78x00:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140_noc_77101_firmware>>*
cpe:2.3:o:schneider-electric:140_noc_77101_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140_noc_77101>>-
cpe:2.3:h:schneider-electric:140_noc_77101:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-200Primarynvd@nist.gov
CWE-200Secondarycybersecurity@se.com
CWE ID: CWE-200
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-200
Type: Secondary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02/cybersecurity@se.com
Not Applicable
Vendor Advisory
https://www.se.com/ww/en/download/document/SEVD-2019-316-02%20/nvd@nist.gov
Vendor Advisory
Hyperlink: https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02/
Source: cybersecurity@se.com
Resource:
Not Applicable
Vendor Advisory
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2019-316-02%20/
Source: nvd@nist.gov
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

3303Records found

CVE-2025-54925
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.05% / 14.87%
||
7 Day CHG+0.01%
Published-20 Aug, 2025 | 13:44
Updated-20 Aug, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards ModuleEcoStruxure™ Power Monitoring Expert (PME)
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)
CVE-2025-54924
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.07% / 21.04%
||
7 Day CHG+0.02%
Published-20 Aug, 2025 | 13:39
Updated-20 Aug, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards ModuleEcoStruxure™ Power Monitoring Expert (PME)
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)
CVE-2020-28217
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.06% / 19.64%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:51
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (firmware 2.7 and older)
CWE ID-CWE-311
Missing Encryption of Sensitive Data
CVE-2020-28216
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.08% / 24.55%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:51
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (firmware 2.7 and older)
CWE ID-CWE-311
Missing Encryption of Sensitive Data
CVE-2022-24318
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.10% / 28.38%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

Action-Not Available
Vendor-n/a
Product-clearscadaecostruxure_geo_scada_expert_2020ecostruxure_geo_scada_expert_2019ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2022-22810
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.30% / 52.96%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)

Action-Not Available
Vendor-n/a
Product-fellerlynkwiser_for_knxspacelynkwiser_for_knx_firmwarefellerlynk_firmwarespacelynk_firmwarespaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2017-6032
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.3||MEDIUM
EPSS-0.46% / 63.07%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modbus_firmwaremodbusSchneider Electric Modicon Modbus Protocol
CWE ID-CWE-358
Improperly Implemented Security Check for Standard
CWE ID-CWE-657
Violation of Secure Design Principles
CVE-2019-6845
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.21% / 42.76%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:49
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol.

Action-Not Available
Vendor-n/a
Product-tsxmrpc001m_firmwaretsxmrpc002m_firmwaretsxmrpp384ktsxmfpp002m_firmwaremodicon_m580_firmwaretsxmrpc448k_firmwaretsxmrpf008mtsxmrpp384k_firmwaretsxmcpc002m_firmwaretsxmrpf004mtsxmrpc768ktsxmrpc01m7tsxmrpp224kmodicon_m580tsxmrpc01m7_firmwaretsxmfp064p2tsxmrpc003m_firmwaretsxmrpc001mtsxmfpp224ktsxmrpc002mtsxmfpp004mtsxmfpp001m_firmwaretsxmrpc768k_firmwaretsxmfpp001mtsxmrpp224k_firmwaretsxmrpc007m_firmwaretsxmfpp512k_firmwaretsxmfpp224k_firmwaretsxmfp0128p2tsxmrpc007mtsxmcpc002mmodicon_m340tsxmfpp384ktsxmrpf008m_firmwaretsxmcpc512ktsxmfp0128p2_firmwaretsxmcpc512k_firmwaretsxmfpp512ktsxmrpf004m_firmwaretsxmfp064p2_firmwaretsxmrpc003mtsxmfpp002mtsxmfpp384k_firmwaretsxmrpc448ktsxmfpp004m_firmwaremodicon_m340_firmwareModicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2019-6859
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.34% / 56.29%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 18:14
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hardcoded Credentials vulnerability exists in Modicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.

Action-Not Available
Vendor-n/a
Product-tsx_ety_x103_firmwarebmx_noe_0100140_noc_78x00140_noe_771x1bmx_noe_0110tsx_ety_x103bmx_noc_0401_firmware140_cpu6x_firmwarebmx_p34x140_noc_78x00_firmware140_noe_771x1_firmware140_cpu6xtsx_p57xbmx_p34x_firmwarebmx_noe_0110_firmware140_noc_77101_firmwarebmx_noc_0401tsx_p57x_firmware140_noc_77101bmx_noe_0100_firmwareModicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2019-6836
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.28% / 50.97%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:14
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file.

Action-Not Available
Vendor-n/a
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0001_firmwaremeg6501-0002meg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Servers (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, and MEG6260-0415 - U.motion KNX Server Plus, Touch 1)
CWE ID-CWE-863
Incorrect Authorization
CVE-2019-6806
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.34% / 56.05%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:04
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CVE-2011-4036
Matching Score-8
Assigner-CERT/CC
ShareView Details
Matching Score-8
Assigner-CERT/CC
CVSS Score-5||MEDIUM
EPSS-0.51% / 65.23%
||
7 Day CHG~0.00%
Published-02 Dec, 2011 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-vijeo_historiancitectscada_reportscitecthistoriann/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2025-2875
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.09% / 27.14%
||
7 Day CHG~0.00%
Published-14 May, 2025 | 08:46
Updated-14 May, 2025 | 13:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could cause a loss of confidentiality when an unauthenticated attacker manipulates controller’s webserver URL to access resources.

Action-Not Available
Vendor-Schneider Electric SE
Product-Modicon Controllers M258 / LMC058Modicon Controllers M241 / M251
CWE ID-CWE-610
Externally Controlled Reference to a Resource in Another Sphere
CVE-2022-43377
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.28% / 51.17%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 19:56
Updated-05 Feb, 2025 | 20:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause account takeover when a brute force attack is performed on the account. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-netbotz_570_firmwarenetbotz_355netbotz_455_firmwarenetbotz_550netbotz_570netbotz_450netbotz_455netbotz_550_firmwarenetbotz_355_firmwarenetbotz_450_firmwareNetBotz 4 - 355/450/455/550/570
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2025-1060
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.04% / 9.82%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 05:53
Updated-13 Feb, 2025 | 15:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure of data when network traffic is being sniffed by an attacker.

Action-Not Available
Vendor-Schneider Electric SE
Product-ASCO 5350 Eight Channel Remote AnnunciatorASCO 5310 Single-Channel Remote Annunciator
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2018-7227
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 40.38%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieving of specially crafted URLs without authentication that can reveal sensitive information to an attacker.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-287
Improper Authentication
CVE-2018-7234
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.14% / 34.94%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 16:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-295
Improper Certificate Validation
CVE-2018-7246
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.16% / 37.31%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of the affected devices could allow remote attackers to discover an administrative account. If default on device, it is not using a SSL in settings and if multiple request of the page "Access Control" (IP-address device/ups/pas_cont.htm) account data will be sent in cleartext

Action-Not Available
Vendor-
Product-mge_galaxy_4000mge_galaxy_5000mge_eps_8000mge_galaxy_pwmge_galaxy_300066074_mge_network_management_card_transversemge_comet_upsmge_eps_6000mge_galaxy_6000mge_galaxy_9000mge_eps_700066074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2018-7779
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.39% / 58.89%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 17:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and spaceLYnk V2.1.0 and prior, weak and unprotected FTP access could allow an attacker unauthorized access.

Action-Not Available
Vendor-
Product-wiser_for_knxhomelynk_firmwarespacelynkwiser_for_knx_firmwarehomelynkspacelynk_firmwareWiser for KNX
CVE-2018-7235
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.31% / 53.43%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-17 Sep, 2024 | 03:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file'

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7837
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.42% / 60.91%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Restriction of XML External Entity Reference ('XXE') vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow the software to resolve documents outside of the intended sphere of control, causing the software to embed incorrect documents into its output and expose restricted information.

Action-Not Available
Vendor-
Product-iiot_moniorIIoT Monitor 3.1.38
CWE ID-CWE-611
Improper Restriction of XML External Entity Reference
CVE-2018-7845
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-4.37% / 88.52%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-125: Out-of-bounds Read vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of unexpected data from the controller when reading specific memory blocks in the controller over Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-125
Out-of-bounds Read
CVE-2018-7820
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.28% / 51.19%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:45
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.

Action-Not Available
Vendor-
Product-ap9630ap9631ap9635smart-ups_srt_5kvaap9635_firmwareap9630_firmwaresmart-ups_srt_5kva_firmwareap9631_firmwareAPC UPS Network Management Card 2 AOS
CWE ID-CWE-255
Not Available
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2018-7846
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-38.19% / 97.12%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:57
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2018-7787
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.21% / 43.31%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 02:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request.

Action-Not Available
Vendor-
Product-u.motion_builderU.motion Builder
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7850
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.70%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-807: Reliance on Untrusted Inputs in a Security Decision vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause invalid information displayed in Unity Pro software.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CVE-2018-7242
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 49.22%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.

Action-Not Available
Vendor-
Product-140cpu65160ctsxp573634mmodicon_m340_bmxp3420302h_firmware140cpu65160_firmwaretsxh5744m_firmwaremodicon_m340_bmxp342020h_firmwaretsxh5744m140cpu65160s_firmwaretsxp571634mcmodicon_m340_bmxp3420102cltsxp574634m_firmwaremodicon_m340_bmxp3420302_firmwaretsxp575634mtsxh5724mc_firmwaretsxp57304mc140cpu65860tsxp575634mc140cpu65160modicon_m340_bmxp3420302cl_firmwaretsxh5744mc_firmwaretsxp573634mc_firmwaremodicon_m340_bmxp342020_firmwaretsxp57454m_firmwaretsxp57254m_firmwaremodicon_m340_bmxp3420102_firmwaretsxp572634mtsxp57554mc_firmwaretsxp574634mtsxh5724mtsxp57304m_firmwaretsxp571634mc_firmwaretsxp57454mcmodicon_m340_bmxp341000h140cpu65160sbmxnor0200_firmwaremodicon_m340_bmxp3420302clbmxnor0200htsxp574634mc_firmwaretsxp57154mctsxp57154m_firmwaretsxp57154mtsxp576634mtsxh5744mctsxp57204mcmodicon_m340_bmxp342020140cpu31110modicon_m340_bmxp342020htsxp57354mc_firmwaretsxp57104m140cpu65150c_firmwaretsxp57354m140cpu65150_firmwaremodicon_m340_bmxp342000_firmware140cpu65860cbmxnor0200h_firmwaretsxp57204m_firmwaretsxp57204m140cpu65260tsxp571634m_firmwaretsxp573634mc140cpu43412uc140cpu65150tsxp571634mtsxp57304mc_firmware140cpu65860_firmwarebmxnor0200modicon_m340_bmxp341000h_firmware140cpu65260ctsxp57354mc140cpu65150c140cpu43412u_firmwaretsxh5724m_firmwaremodicon_m340_bmxp342000tsxp575634m_firmwaretsxp573634m_firmwaretsxp57204mc_firmwaretsxp57104mc_firmwaremodicon_m340_bmxp341000tsxh5724mc140cpu65260c_firmwaretsxp57254mc_firmware140cpu31110_firmware140cpu31110ctsxp57304mtsxp576634mcmodicon_m340_bmxp3420302htsxp574634mcmodicon_m340_bmxp3420102cl_firmwaretsxp572634mc_firmwaretsxp57454mc_firmwaretsxp576634mc_firmwaretsxp57554mctsxp575634mc_firmware140cpu65160c_firmwaretsxp576634m_firmware140cpu65260_firmwaremodicon_m340_bmxp3420302140cpu43412uc_firmwaretsxp57454mtsxp572634mcmodicon_m340_bmxp341000_firmwaretsxp57254mtsxp57104m_firmwaretsxp572634m_firmwaretsxp57554mtsxp57254mctsxp57354m_firmwaretsxp57104mctsxp57554m_firmwaremodicon_m340_bmxp3420102140cpu31110c_firmware140cpu43412utsxp57154mc_firmware140cpu65860c_firmwareModicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2018-7792
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.27% / 50.39%
||
7 Day CHG~0.00%
Published-29 Aug, 2018 | 21:00
Updated-17 Sep, 2024 | 01:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table.

Action-Not Available
Vendor-
Product-modicon_m221_firmwaremodicon_m221Modicon M221, all references, all versions prior to firmware V1.6.2.0
CWE ID-CWE-862
Missing Authorization
CVE-2024-2052
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.08% / 25.41%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 16:05
Updated-15 Aug, 2024 | 16:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-552: Files or Directories Accessible to External Parties vulnerability exists that could allow unauthenticated files and logs exfiltration and download of files when an attacker modifies the URL to download to a different location.

Action-Not Available
Vendor-
Product-Easergy T200 (Modbus) Models: T200I, T200E, T200P, T200S, T200H Easergy T200 (IEC104) Models: T200I, T200E, T200P, T200S, T200HEasergy T200 (DNP3) Models: T200I, T200E, T200P, T200S, T200Ht200i
CWE ID-CWE-552
Files or Directories Accessible to External Parties
CVE-2020-7541
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.31% / 53.85%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:52
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted request to the controller over HTTP.

Action-Not Available
Vendor-n/a
Product-140noc78100140cpu65150140noc78000_firmwaretsxp575634_firmware140noc78000bmxnoe0110_firmwaretsxp574634modicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmware140noc78100_firmwaremodicon_m340_bmxp342000modicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000140noe77111_firmwaremodicon_m340_bmxp342020_firmware140noc77101_firmwaremodicon_m340_bmxp3420102_firmware140noc77101bmxnoe0110tsxety5103_firmwaremodicon_m340_bmxp3420102cl_firmwaretsxety5103tsxp574634_firmwarebmxnoc0401_firmware140noe77111modicon_m340_bmxp3420302clmodicon_m340_bmxp3420302modicon_m340_bmxp342020bmxnoe0100_firmwaretsxp576634modicon_m340_bmxp341000_firmwaretsxety4103_firmwarebmxnoc0401tsxp576634_firmwaremodicon_m340_bmxp342000_firmwarebmxnoe0100140cpu65150_firmwaremodicon_m340_bmxp3420102tsxety4103tsxp575634Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
CWE ID-CWE-425
Direct Request ('Forced Browsing')
CVE-2021-22793
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.54% / 66.77%
||
7 Day CHG~0.00%
Published-02 Sep, 2021 | 16:53
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol.

Action-Not Available
Vendor-n/a
Product-accusine_pcsnaccusine_pcsn_active_harmonic_filter_firmwareaccusine_pcs\+accusine_pfv\+accusine_pcsp_pfvp_firmwareAccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4)
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22770
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.33% / 54.98%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 with firmware V2.7.1 and older
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22728
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.33% / 54.98%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:43
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials when consulting the maintenance report.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22740
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.33% / 54.98%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:20
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.

Action-Not Available
Vendor-n/a
Product-homelynkspacelynk_firmwarehomelynk_firmwarespacelynkhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22739
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.9||MEDIUM
EPSS-0.32% / 54.68%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:20
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured.

Action-Not Available
Vendor-n/a
Product-homelynkspacelynk_firmwarehomelynk_firmwarespacelynkhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22825
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.38% / 58.62%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)

Action-Not Available
Vendor-n/a
Product-rack_power_distribution_unit_with_network_management_card_3_firmwarerack_power_distribution_unit_with_network_management_card_3rack_power_distribution_unit_with_network_management_card_2rack_power_distribution_unit_with_network_management_card_2_firmwaren/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-12142
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.10% / 28.42%
||
7 Day CHG+0.01%
Published-17 Jan, 2025 | 10:19
Updated-12 Feb, 2025 | 16:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure of restricted web page, modification of web page and denial of service when specific web pages are modified and restricted functions are invoked.

Action-Not Available
Vendor-Schneider Electric SE
Product-Modicon M340 processors (part numbers BMXP34*)BMXNOE0110BMXNOE0100BMXNOR0200H
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2015-0998
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-3.3||LOW
EPSS-0.23% / 45.34%
||
7 Day CHG~0.00%
Published-29 Mar, 2015 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.

Action-Not Available
Vendor-n/aSchneider Electric SEAVEVA
Product-wonderware_intouch_2014aveva_edgen/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2025-8448
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-2.3||LOW
EPSS-0.02% / 4.42%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 13:58
Updated-20 Aug, 2025 | 15:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products.

Action-Not Available
Vendor-Schneider EelctricSchneider Electric SE
Product-EcoStruxureTM Building Operation Enterprise ServerEcoStruxureTM WorkstationEcoStruxureTM Enterprise Server
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2020-7568
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-4.3||MEDIUM
EPSS-0.08% / 24.99%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.

Action-Not Available
Vendor-n/a
Product-modicon_m221_firmwaremodicon_m221Modicon M221, all references, all versions
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22783
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.09% / 26.98%
||
7 Day CHG~0.00%
Published-09 Mar, 2022 | 23:05
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door (All versions)

Action-Not Available
Vendor-
Product-ritto_wiser_doorRitto Wiser Door
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-8884
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.24% / 46.42%
||
7 Day CHG~0.00%
Published-08 Oct, 2024 | 10:32
Updated-10 Oct, 2024 | 12:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause exposure of credentials when attacker has access to application on network over http

Action-Not Available
Vendor-
Product-System Monitor application in Harmony Industrial PC HMIBMO/HMIBMI/HMIPSO/HMIBMP/HMIBMU/HMIPSP/HMIPEP seriesSystem Monitor application in Pro-face Industrial PC PS5000 seriessystem_monitor_application_in_harmony_industrial_pc_hmibmo_hmibmi_hmipso_hmibmp_hmibmu_hmipsp_hmipep_series
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-7776
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-4.3||MEDIUM
EPSS-0.36% / 57.64%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 23:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. System information is returned to the attacker that contains sensitive data.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2015-0999
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-2.1||LOW
EPSS-0.06% / 19.41%
||
7 Day CHG~0.00%
Published-29 Mar, 2015 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.

Action-Not Available
Vendor-n/aSchneider Electric SEAVEVA
Product-wonderware_intouch_2014aveva_edgen/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2015-0996
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-2.1||LOW
EPSS-0.06% / 19.41%
||
7 Day CHG~0.00%
Published-29 Mar, 2015 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password.

Action-Not Available
Vendor-n/aSchneider Electric SEAVEVA
Product-wonderware_intouch_2014aveva_edgen/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2011-1015
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-5||MEDIUM
EPSS-0.16% / 37.10%
||
7 Day CHG~0.00%
Published-09 May, 2011 | 22:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The is_cgi method in CGIHTTPServer.py in the CGIHTTPServer module in Python 2.5, 2.6, and 3.0 allows remote attackers to read script source code via an HTTP GET request that lacks a / (slash) character at the beginning of the URI.

Action-Not Available
Vendor-n/aPython Software Foundation
Product-pythonn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2010-1800
Matching Score-4
Assigner-Apple Inc.
ShareView Details
Matching Score-4
Assigner-Apple Inc.
CVSS Score-5||MEDIUM
EPSS-0.30% / 52.57%
||
7 Day CHG~0.00%
Published-25 Aug, 2010 | 19:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CFNetwork in Apple Mac OS X 10.6.3 and 10.6.4 supports anonymous SSL and TLS connections, which allows man-in-the-middle attackers to redirect a connection and obtain sensitive information via crafted responses.

Action-Not Available
Vendor-n/aApple Inc.
Product-cfnetworkmac_os_xmac_os_x_servern/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-21069
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.12% / 32.20%
||
7 Day CHG~0.00%
Published-08 Apr, 2020 | 17:22
Updated-05 Aug, 2024 | 12:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Samsung mobile devices with N(7.x) (MediaTek chipsets) software. There is information disclosure (of kernel stack memory) in a MediaTek driver. The Samsung ID is SVE-2018-11852 (July 2018).

Action-Not Available
Vendor-n/aGoogle LLC
Product-androidn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-38456
Matching Score-4
Assigner-Patchstack
ShareView Details
Matching Score-4
Assigner-Patchstack
CVSS Score-4.3||MEDIUM
EPSS-0.26% / 49.46%
||
7 Day CHG~0.00%
Published-15 Mar, 2023 | 14:46
Updated-13 Jan, 2025 | 15:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WordPress Ajax Search Lite Plugin <= 4.10.3 is vulnerable to Sensitive Data Exposure

Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Ernest Marcinko Ajax Search Lite plugin <= 4.10.3 versions.

Action-Not Available
Vendor-ajax_search_projectErnest Marcinko
Product-ajax_searchAjax Search Lite
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2011-1569
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-10.86% / 93.11%
||
7 Day CHG~0.00%
Published-05 Apr, 2011 | 15:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

download.aspx in Douran Portal 3.9.7.8 allows remote attackers to obtain source code of arbitrary files under the web root via (1) a trailing ".", (2) a trailing space, or (3) mixed case in the FileNameAttach parameter.

Action-Not Available
Vendor-dourann/a
Product-portaln/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 66
  • 67
  • Next
Details not found