BB-ESWGP506-2SFP-T versions 1.01.09 and prior is vulnerable due to the use of hard-coded credentials, which may allow an attacker to gain unauthorized access and permit the execution of arbitrary code on the BB-ESWGP506-2SFP-T (versions 1.01.01 and prior).
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.
Swann SWWHD-INTCAM-HD devices have the twipc root password, leading to FTP access as root. NOTE: all affected customers were migrated by 2020-08-31.
Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters.
Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key.
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
Use of Hard-coded Credentials vulnerability in Samsung Electronics MagicINFO 9 Server allows Authentication Bypass.This issue affects MagicINFO 9 Server: less than 21.1080.0.
A hidden backdoor on PATLITE NH-FB Series devices with firmware version 1.45 or earlier, NH-FV Series devices with firmware version 1.10 or earlier, and NBM Series devices with firmware version 1.09 or earlier allow attackers to enable an SSH daemon via the "kankichi" or "kamiyo4" password to the _secret1.htm URI. Subsequently, the default password of root for the root account allows an attacker to conduct remote code execution and as a result take over the system.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The admin account has a blank password.
A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability.
Use of Hard-coded Credentials vulnerability in Samsung Electronics MagicINFO 9 Server allows Authentication Bypass.This issue affects MagicINFO 9 Server: less than 21.1080.0.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. There is a hardcoded Ak47@99 password for the factory~ account.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The CGIProxy.fcgi?cmd=setTelnetSwitch feature is authorized for the root user with a password of toor.
Milesight IP security cameras through 2016-11-14 have a hardcoded SSL private key under the /etc/config directory.
Milesight IP security cameras through 2016-11-14 have a default set of 10 privileged accounts with hardcoded credentials. They are accessible if the customer has not configured 10 actual user accounts.
Milesight IP security cameras through 2016-11-14 have a default root password in /etc/shadow that is the same across different customers' installations.
An issue was discovered on VOBOT CLOCK before 0.99.30 devices. An SSH server exists with a hardcoded vobot account that has root access.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
Hardcoded manufacturer credentials and an OS command injection vulnerability in the /cgi-bin/mft/ directory on ABUS TVIP TVIP20050 LM.1.6.18, TVIP10051 LM.1.6.18, TVIP11050 MG.1.6.03.05, TVIP20550 LM.1.6.18, TVIP10050 LM.1.6.18, TVIP11550 MG.1.6.03, TVIP21050 MG.1.6.03, and TVIP51550 MG.1.6.03 cameras allow remote attackers to execute code as root.
dirary0.js on D-Link DIR-140L, DIR-640L devices allows remote unauthenticated attackers to discover admin credentials.
atbox.htm on D-Link DSL-2770L devices allows remote unauthenticated attackers to discover admin credentials.
ExaGrid appliances with firmware before 4.8 P26 have a default password of (1) inflection for the root shell account and (2) support for the support account in the web interface, which allows remote attackers to obtain administrative access via an SSH or HTTP session.
Versions of DocuTrac QuicDoc and Office Therapy that ship with DTISQLInstaller.exe version 1.6.4.0 and prior contain three credentials with known passwords: QDMaster, OTMaster, and sa.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
Siklu EtherHaul radios before 3.7.1 and 6.x before 6.9.0 have a built-in, hidden root account, with an unchangeable password that is the same across all devices. This account is accessible via both SSH and the device's web interface and grants access to the underlying embedded Linux OS on the device, allowing full control over it.
An authentication bypass vulnerability in the /web/um_open_telnet.cgi endpoint in Nexxt Solutions NCM-X1800 Mesh Router firmware UV1.2.7 and below, allowing an attacker to remotely enable the Telnet service without authentication, bypassing security controls. The Telnet server is then accessible with hard-coded credentials, allowing attackers to gain administrative shell access and execute arbitrary commands on the device.
POSIM EVO 15.13 for Windows includes hardcoded database credentials for the "root" database user. "root" access to POSIM EVO's database may result in a breach of confidentiality, integrity, or availability or allow for attackers to remotely execute code on associated POSIM EVO clients.
NETGEAR Arlo base stations with firmware 1.7.5_6178 and earlier, Arlo Q devices with firmware 1.8.0_5551 and earlier, and Arlo Q Plus devices with firmware 1.8.1_6094 and earlier have a default password of 12345678, which makes it easier for remote attackers to obtain access after a factory reset or in a factory configuration.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Encrypted database credentials in LaborOfficeFree affecting version 19.10. This vulnerability allows an attacker to read and extract the username and password from the database of 'LOF_service.exe' and 'LaborOfficeFree.exe' located in the '%programfiles(x86)%\LaborOfficeFree\' directory. This user can log in remotely and has root-like privileges.
Austrian Archaeological Institute (AI) OpenAtlas v8.11.0 as discovered to contain a hardcoded Administrator password.
Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers' installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option.
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software before version 20240417.001 (from that version vulnerability is fixed).
Invoxia NVX220 devices allow TELNET access as admin with a default password.
A vulnerability in the Cisco Small Business Switches software could allow an unauthenticated, remote attacker to bypass the user authentication mechanism of an affected device. The vulnerability exists because under specific circumstances, the affected software enables a privileged user account without notifying administrators of the system. An attacker could exploit this vulnerability by using this account to log in to an affected device and execute commands with full admin rights. Cisco has not released software updates that address this vulnerability. This advisory will be updated with fixed software information once fixed software becomes available. There is a workaround to address this vulnerability.
A vulnerability in Cisco Video Surveillance Manager (VSM) Software running on certain Cisco Connected Safety and Security Unified Computing System (UCS) platforms could allow an unauthenticated, remote attacker to log in to an affected system by using the root account, which has default, static user credentials. The vulnerability is due to the presence of undocumented, default, static user credentials for the root account of the affected software on certain systems. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
go-admin (aka GO Admin) 2.0.12 uses the string go-admin as a production JWT key.
Gessler GmbH WEB-MASTER has a restoration account that uses weak hard coded credentials and if exploited could allow an attacker control over the web management of the device.
Programi Bilanc Build 007 Release 014 31.01.2020 supplies a .exe file containing several hardcoded credentials to different servers that allow remote attackers to gain access to the complete infrastructure including the website, update server, and external issue tracking tools.
TimeTools SC7105 1.0.007, SC9205 1.0.007, SC9705 1.0.007, SR7110 1.0.007, SR9210 1.0.007, SR9750 1.0.007, SR9850 1.0.007, T100 1.0.003, T300 1.0.003, and T550 1.0.003 devices allow remote attackers to bypass authentication by placing t3axs=TiMEtOOlsj7G3xMm52wB in a t3.cgi request, aka a "hardcoded cookie."
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Quest Foglight Evolve 9.0.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the __service__ user account. The product contains a hard-coded password for this account. An attacker can leverage this vulnerability to execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-9553.
An issue was discovered in EyesOfNetwork 5.3. The installation uses the same API key (hardcoded as EONAPI_KEY in include/api_functions.php for API version 2.4.2) by default for all installations, hence allowing an attacker to calculate/guess the admin access token.
Intellian Aptus Web 1.24 has a hardcoded password of 12345678 for the intellian account.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in the Unity Loader and OS Loader Software (all versions). The fixed credentials are used to simplify file transfer. Today the use of fixed credentials is considered a vulnerability, which could cause unauthorized access to the file transfer service provided by the Modicon PLCs. This could result in various unintended results.
The Intellian Aptus application 1.0.2 for Android has a hardcoded password of intellian for the masteruser FTP account.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console.