SonarQube 8.4.2.36762 allows remote attackers to discover cleartext SMTP, SVN, and GitLab credentials via the api/settings/values URI. NOTE: reportedly, the vendor's position for SMTP and SVN is "it is the administrator's responsibility to configure it.
An issue was discovered on the NEC Aterm WG2600HP2 1.0.2. The router has a set of web service APIs for access to and setup of the configuration. Some APIs don't require authentication. An attacker could exploit this vulnerability by sending a crafted HTTP request to retrieve DHCP clients, firmware version, and network status (ex.: curl -X http://[IP]/aterm_httpif.cgi/negotiate -d "REQ_ID=SUPPORT_IF_GET").
Zoho ManageEngine OpManager before 125120 allows an unauthenticated user to retrieve an API key via a servlet call.
Veritas APTARE versions prior to 10.4 allowed sensitive information to be accessible without authentication.
An information disclosure vulnerability in the /cgi-bin/ExportAllSettings.sh endpoint of the WAVLINK WN530H4 M30H4.V5030.190403 allows an attacker to leak router settings, including cleartext login details, DNS settings, and other sensitive information without authentication.
An issue was discovered in CIPPlanner CIPAce 6.80 Build 2016031401. GetDistributedPOP3 allows attackers to obtain the username and password of the SMTP user.
Motorola FX9500 devices allow remote attackers to read database files.
PRTG Network Monitor before 20.1.57.1745 allows remote unauthenticated attackers to obtain information about probes running or the server itself (CPU usage, memory, Windows version, and internal statistics) via an HTTP request, as demonstrated by type=probes to login.htm or index.htm.
An issue was discovered in Wavlink WN530HG4, Wavlink WN531G3, Wavlink WN533A8, and Wavlink WN551K1 affecting /cgi-bin/ExportAllSettings.sh where a crafted POST request returns the current configuration of the device, including the administrator password. No authentication is required. The attacker must perform a decryption step, but all decryption information is readily available.
An issue was discovered in Chadha PHPKB 9.0 Enterprise Edition. installer/test-connection.php (part of the installation process) allows a remote unauthenticated attacker to disclose local files on hosts running PHP before 7.2.16, or on hosts where the MySQL ALLOW LOCAL DATA INFILE option is enabled.
Missing Authentication for Critical Function vulnerability in Drupal Config Pages Viewer allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects Config Pages Viewer: from 0.0.0 before 1.0.4.
An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
Grundfos CIM 500 before v06.16.00 responds to unauthenticated requests for password storage files.
An issue was discovered on Samsung mobile devices with Q(10.0) software. The DeX Lockscreen allows attackers to access the quick panel and notifications. The Samsung ID is SVE-2019-16532 (March 2020).
Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol leaks information regarding the receiving serverinformation, license information and managing licenses, among others.Through this flaw, attackers can retreive information about a KUKA simulation system, particularly, the version ofthe licensing server, which is connected to the simulator, and which will allow them to launch local simulationswith similar characteristics, further understanding the dynamics of motion virtualization and opening doors toother attacks (see RVDP#711 and RVDP#712 for subsequent vulnerabilities that compromise integrity andavailability).Beyond compromising simulations, Visual Components provides capabilities to interface with industrial machinery.Particularly, their PLC Connectivity feature 'makes it easy' to connect simulations with control systems usingeither the industry standard OPC UA or other supported vendor specific interfaces. This fills the gap of jumpingfrom simulation to real and enables attackers to pivot from the Visual Components simulator to robots or otherIndustrial Control System (ICS) devices, such as PLCs.
Various Lexmark products have Incorrect Access Control (issue 1 of 2).
The Glen Dimplex Deutschland GmbH implementation of the Carel pCOWeb configuration tool allows remote attackers to obtain access via an HTTP session on port 10000, as demonstrated by reading the modem password (which is 1234), or reconfiguring "party mode" or "vacation mode."
In Couchbase Server 5 through 7 before 7.1.4, the nsstats endpoint is accessible without authentication.
Unauthenticated password hash disclosure in the User.getUserPWD method in eQ-3 AG Homematic CCU3 3.43.15 and earlier allows remote attackers to retrieve the GUI password hashes of GUI users. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
The /rest/api/latest/groupuserpicker resource in Jira before version 8.4.0 allows remote attackers to enumerate usernames via an information disclosure vulnerability.
The WebApp v04.68 in the supervisor on SAET Impianti Speciali TEBE Small 05.01 build 1137 devices allows remote attackers to make several types of API calls without authentication, as demonstrated by retrieving password hashes via an inc/utils/REST_API.php?command=CallAPI&customurl=alladminusers call.
D-Link routers with the mydlink feature have some web interfaces without authentication requirements. An attacker can remotely obtain users' DNS query logs and login logs. Vulnerable targets include but are not limited to the latest firmware versions of DIR-817LW (A1-1.04), DIR-816L (B1-2.06), DIR-816 (B1-2.06?), DIR-850L (A1-1.09), and DIR-868L (A1-1.10).
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation.
Avdor CIS - crystal quality Credentials Management Errors. The product is phone call recorder, you can hear all the recorded calls without authenticate to the system. Attacker sends crafted URL to the system: ip:port//V=2;ChannellD=number;Ext=number;Command=startLM;Client=number;Request=number;R=number number - id of the recorded number.
IBM Robotic Process Automation with Automation Anywhere 11 could allow an attacker to obtain sensitive information due to missing authentication in Ignite nodes. IBM X-Force ID: 161412.
IBM Security Directory Server 6.4.0 does not perform an authentication check for a critical resource or functionality allowing anonymous users access to protected areas. IBM X-Force ID: 165953.
Missing authentication in the GetLogFiles method in IDAttend’s IDWeb application 3.1.052 and earlier allows retrieval of sensitive log files by unauthenticated attackers.
SAP NetWeaver Application Server Java for Classload Service - version 7.50, does not perform any authentication checks for functionalities that require user identity, resulting in escalation of privileges. This failure has a low impact on confidentiality of the data such that an unassigned user can read non-sensitive server data.
All versions up to BD_R218V2.4 of ZTE MF920 product are impacted by information leak vulnerability. Due to some interfaces can obtain the WebUI login password without login, an attacker can exploit the vulnerability to obtain sensitive information about the affected components.
An issue was discovered in Scytl sVote 2.1. Because the sdm-ws-rest API does not require authentication, an attacker can retrieve the administrative configuration by sending a POST request to the /sdm-ws-rest/preconfiguration URI.
A certain router administration interface (that includes Realtek APMIB 0.11f for Boa 0.94.14rc21) allows remote attackers to retrieve the configuration, including sensitive data (usernames and passwords). This affects TOTOLINK A3002RU through 2.0.0, A702R through 2.1.3, N301RT through 2.1.6, N302R through 3.4.0, N300RT through 3.4.0, N200RE through 4.0.0, N150RT through 3.4.0, and N100RE through 3.4.0; Rutek RTK 11N AP through 2019-12-12; Sapido GR297n through 2019-12-12; CIK TELECOM MESH ROUTER through 2019-12-12; KCTVJEJU Wireless AP through 2019-12-12; Fibergate FGN-R2 through 2019-12-12; Hi-Wifi MAX-C300N through 2019-12-12; HCN MAX-C300N through 2019-12-12; T-broad GN-866ac through 2019-12-12; Coship EMTA AP through 2019-12-12; and IO-Data WN-AC1167R through 2019-12-12.
Zoho ManageEngine Applications Manager 14 before 14520 allows a remote unauthenticated attacker to disclose OS file names via FailOverHelperServlet.
Zoho ManageEngine Applications Manager before 14600 allows a remote unauthenticated attacker to disclose license related information via WieldFeedServlet servlet.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Honeywell equIP and Performance series IP cameras, multiple versions, A vulnerability exists where the affected product allows unauthenticated access to audio streaming over HTTP.
An issue was discovered in the Infosysta "In-App & Desktop Notifications" app 1.6.13_J8 for Jira. It is possible to obtain a list of all valid Jira usernames without authentication/authorization via the plugins/servlet/nfj/UserFilter?searchQuery=@ URI.
Argo CD is a declarative, GitOps continuous delivery tool for Kubernetes. The vulnerability allows unauthorized access to the sensitive settings exposed by /api/v1/settings endpoint without authentication. All sensitive settings are hidden except passwordPattern. This vulnerability is fixed in 2.11.3, 2.10.12, and 2.9.17.
D-Link DAP-1320 A2-V1.21 routers have some web interfaces without authentication requirements, as demonstrated by uplink_info.xml. An attacker can remotely obtain a user's Wi-Fi SSID and password, which could be used to connect to Wi-Fi or perform a dictionary attack.
includes/class-coming-soon-creator.php in the igniteup plugin through 3.4 for WordPress allows information disclosure.
There are some web interfaces without authentication requirements on D-Link DIR-412 A1-1.14WW routers. An attacker can get the router's log file via log_get.php, which could be used to discover the intranet network structure.
A vulnerability in the web-based management interface of Cisco UCS Director could allow an unauthenticated, remote attacker to download system log files from an affected device. The vulnerability is due to an issue in the authentication logic of the web-based management interface. An attacker could exploit this vulnerability by sending a crafted request to the web interface. A successful exploit could allow the attacker to download log files if they were previously generated by an administrator.
DTEN D5 and D7 before 1.3.2 devices allows remote attackers to read saved whiteboard image PDF documents via storage/emulated/0/Notes/PDF on TCP port 8080 without authentication.
Sphinx Technologies Sphinx 3.1.1 by default has no authentication and listens on 0.0.0.0, making it exposed to the internet (unless filtered by a firewall or reconfigured to listen to 127.0.0.1 only).
Admin authentication can be bypassed with some specific invalid credentials, which allows logging in with an administrative privilege. Sharp Corporation states the telnet feature is implemented on older models only, and is planning to provide the firmware update to remove the feature. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References].
The Recruitment module in Humanica Humatrix 7 1.0.0.203 and 1.0.0.681 allows an unauthenticated attacker to access all candidates' files in the photo folder on the website by specifying a "user id" parameter and file name, such as in a recruitment_online/upload/user/[user_id]/photo/[file_name] URI.
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).
All configuration parameters of certain Kyocera printers (such as the ECOSYS M5526cdw 2R7_2000.001.701) were accessible by unauthenticated users. This information was only presented in the menus when authenticated, and the pages that loaded this information were also protected. However, all files that contained the configuration parameters were accessible. These files contained sensitive information, such as users, community strings, and other passwords configured in the printer.
In IP-AK2 Access Control Panel Version 1.04.07 and prior, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data, which can be accessed without authentication over the network.
In WESEEK GROWI before 3.5.0, a remote attacker can obtain the password hash of the creator of a page by leveraging wiki access to make API calls for page metadata. In other words, the password hash can be retrieved even though it is not a publicly available field.
Some Brother printers (such as the HL-L8360CDW v1.20) were affected by different information disclosure vulnerabilities that provided sensitive information to an unauthenticated user who visits a specific URL.