CVE-2020-15787

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-09 Sep, 2020 | 18:11
Updated At-04 Aug, 2024 | 13:22
Rejected At-
Credits

A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:09 Sep, 2020 | 18:11
Updated At:04 Aug, 2024 | 13:22
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

Affected Products
Vendor
Siemens AGSiemens
Product
SIMATIC HMI Unified Comfort Panels
Versions
Affected
  • All versions <= V16
Problem Types
TypeCWE IDDescription
CWECWE-305CWE-305: Authentication Bypass by Primary Weakness
Type: CWE
CWE ID: CWE-305
Description: CWE-305: Authentication Bypass by Primary Weakness
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:09 Sep, 2020 | 19:15
Updated At:08 Jun, 2021 | 20:15

A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.05.0MEDIUM
AV:N/AC:L/Au:N/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 5.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:N/C:P/I:N/A:N
CPE Matches

Siemens AG
siemens
>>simatic_hmi_united_comfort_panels_firmware>>*
cpe:2.3:o:siemens:simatic_hmi_united_comfort_panels_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_united_comfort_panels>>-
cpe:2.3:h:siemens:simatic_hmi_united_comfort_panels:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-305Primaryproductcert@siemens.com
CWE-287Secondarynvd@nist.gov
CWE ID: CWE-305
Type: Primary
Source: productcert@siemens.com
CWE ID: CWE-287
Type: Secondary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdfproductcert@siemens.com
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf
Source: productcert@siemens.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1206Records found

CVE-2020-15798
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.18% / 77.89%
||
7 Day CHG~0.00%
Published-09 Feb, 2021 | 15:38
Updated-04 Aug, 2024 | 13:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)

Action-Not Available
Vendor-Siemens AG
Product-sinamics_gh150_firmwaresinamics_sl150sinamics_sh150simatic_hmi_ktp_mobile_panels_firmwaresinamics_sm150_firmwaresinamics_sh150_firmwaresinamics_gm150sinamics_sm120simatic_hmi_ktp_mobile_panelssinamics_gl150_firmwaresinamics_sm150isinamics_gl150sinamics_sl150_firmwaresinamics_sm150i_firmwaresimatic_hmi_comfort_panelssinamics_gm150_firmwaresinamics_sm150simatic_hmi_comfort_panels_firmwaresinamics_gh150sinamics_sm120_firmwareSINAMICS SL150SINAMICS SM150iSIMATIC HMI Comfort Panels (incl. SIPLUS variants)SINAMICS GH150SINAMICS GM150 (with option X30)SINAMICS SM120SIMATIC HMI KTP Mobile PanelsSINAMICS SM150SINAMICS GL150 (with option X30)SINAMICS SH150
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-15782
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.41% / 60.60%
||
7 Day CHG~0.00%
Published-28 May, 2021 | 16:10
Updated-04 Aug, 2024 | 13:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.

Action-Not Available
Vendor-Siemens AG
Product-s7-1200_cpu_firmware6es7515-2fm01-0ab06es7516-3an02-0ab06es7515-2rm00-0ab06es7515-2am02-0ab06es7512-1ck00-0ab06es7513-1fl02-0ab06es7516-3fn02-0ab0cpu_1214csimatic_driver_controller_firmwarecpu_1212fc6es7512-1dk01-0ab06es7517-3up00-0ab0cpu_1515sp_pc6es7513-1rl00-0ab06es7517-3fp00-0ab0cpu_1211c6es7512-1ck01-0ab06es7511-1uk01-0ab06es7515-2fm02-0ab06es7511-1fk02-0ab06es7515-2um01-0ab0cpu_1507d_tf6es7511-1ak02-0ab06es7513-1al02-0ab0cpu_1217c6es7513-2gl00-0ab0et_200sp_open_controller_firmwarecpu_1215fc6es7510-1sj01-0ab0cpu_1214fc6es7516-3an01-0ab06es7518-4fp00-0ab06es7518-4fp00-3ab0simatic_s7-1500__software_controller6es7511-1fk01-0ab06es7515-2tm01-0ab06es7511-1ak01-0ab06es7513-2pl00-0ab0cpu_1215c6es7518-4ap00-0ab06es7516-3tn00-0ab06es7517-3ap00-0ab06es7517-3hp00-0ab06es7512-1sk01-0ab06es7518-4ap00-3ab0cpu_1515sp_pc26es7515-2am01-0ab0cpu_1504d_tf6es7511-1ck00-0ab06es7511-1tk01-0ab06es7513-1al01-0ab06es7510-1dj01-0ab06es7513-1fl01-0ab06es7516-3fn01-0ab0cpu_1212c6es7517-3tp00-0ab06es7516-3un00-0ab06es7511-1ck01-0ab0simatic_s7-plcsim_advanced6es7516-2gn00-0ab0s7-1500_cpu_firmware6es7516-2pn00-0ab0SINUMERIK ONESIMATIC S7-1500 Software ControllerSINAMICS PERFECT HARMONY GH180 DrivesSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIMATIC Drive Controller familySIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)SINUMERIK MCSIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)SIMATIC S7-PLCSIM Advanced
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-42016
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.14% / 34.66%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-12 Aug, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i801, RUGGEDCOM i802, RUGGEDCOM i803, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM RMC30, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RP110, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600T, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS401, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000H, RUGGEDCOM RS8000T, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900L, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS969, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSL910, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. A timing attack, in a third-party component, could make the retrieval of the private key possible, used for encryption of sensitive data. If a threat actor were to exploit this, the data integrity and security could be compromised.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rs969ruggedcom_rs910ruggedcom_rsg2100ruggedcom_rsg2300pruggedcom_rs930lruggedcom_rsg907rruggedcom_rsg910cruggedcom_rs416ruggedcom_rs900wruggedcom_i801ruggedcom_rosruggedcom_m2100ruggedcom_rmcruggedcom_i800ruggedcom_rst2228ruggedcom_rs930wruggedcom_rmc8388ruggedcom_rsg2200ruggedcom_rs900ruggedcom_rs401ruggedcom_rs8000truggedcom_rsg909rruggedcom_rp110ruggedcom_rs910lruggedcom_i802ruggedcom_m969ruggedcom_rs910wruggedcom_rsg2100pruggedcom_rs8000ruggedcom_rst916pruggedcom_rs900gpruggedcom_rs900lruggedcom_rmc40ruggedcom_rsl910ruggedcom_rmc41ruggedcom_rsg920pruggedcom_rs920wruggedcom_rs416v2ruggedcom_rs8000aruggedcom_rsg2300ruggedcom_rst916cruggedcom_m2200ruggedcom_rs400ruggedcom_rst2228pruggedcom_rmc20ruggedcom_rs8000hruggedcom_rsg908cruggedcom_i803ruggedcom_rsg2488ruggedcom_rs900gruggedcom_rsg2288ruggedcom_rs920lruggedcom_rs940gruggedcom_rmc30RUGGEDCOM RS8000RUGGEDCOM RS900LRUGGEDCOM RSG2300 V4.XRUGGEDCOM RSG920P V4.XRUGGEDCOM RS930WRUGGEDCOM RS910LRUGGEDCOM RSG2300P V4.XRUGGEDCOM RS416v2 V5.XRUGGEDCOM RSG2100 (32M) V5.XRUGGEDCOM RS416Pv2 V4.XRUGGEDCOM RS1600RUGGEDCOM RS920WRUGGEDCOM RS940GRUGGEDCOM RS900FRUGGEDCOM M2200RUGGEDCOM RS910RUGGEDCOM RSG908CRUGGEDCOM RS900RUGGEDCOM RS400FRUGGEDCOM RS920LRUGGEDCOM RMC8388 V4.XRUGGEDCOM RSG2100RUGGEDCOM RS8000HRUGGEDCOM RS400RUGGEDCOM RS8000TRUGGEDCOM RS900G (32M) V4.XRUGGEDCOM M969RUGGEDCOM RS416PFRUGGEDCOM RS900GRUGGEDCOM M2100FRUGGEDCOM RS900M-STND-XXRUGGEDCOM RS900WRUGGEDCOM RS8000ARUGGEDCOM RMC8388 V5.XRUGGEDCOM i803RUGGEDCOM RSG910CRUGGEDCOM RSG2300PFRUGGEDCOM RSG2288 V4.XRUGGEDCOM RSG2488FRUGGEDCOM RS969RUGGEDCOM RSG2200RUGGEDCOM RS900 (32M) V4.XRUGGEDCOM RSG909RRUGGEDCOM RS416RUGGEDCOM RS416FRUGGEDCOM RS900GPFRUGGEDCOM RST2228PRUGGEDCOM RSG2100PRUGGEDCOM i800RUGGEDCOM RS416PRUGGEDCOM RS900M-STND-C01RUGGEDCOM RS900M-GETS-XXRUGGEDCOM RST916PRUGGEDCOM RSG920P V5.XRUGGEDCOM RSG2100 (32M) V4.XRUGGEDCOM RSG2288 V5.XRUGGEDCOM RS1600FRUGGEDCOM RSL910RUGGEDCOM RSG907RRUGGEDCOM RS930LRUGGEDCOM RSG2300P V5.XRUGGEDCOM RS910WRUGGEDCOM RSG2300 V5.XRUGGEDCOM RSG2100PFRUGGEDCOM RS900GPRUGGEDCOM RST916CRUGGEDCOM RSG2100FRUGGEDCOM RSG2488 V4.XRUGGEDCOM i802RUGGEDCOM RSG2100P (32M) V4.XRUGGEDCOM RS940GFRUGGEDCOM RSG2488 V5.XRUGGEDCOM RST2228RUGGEDCOM RS401RUGGEDCOM RMC30RUGGEDCOM RS900GFRUGGEDCOM M2100RUGGEDCOM RSG2300FRUGGEDCOM RS1600TRUGGEDCOM M969FRUGGEDCOM RS900G (32M) V5.XRUGGEDCOM RS416Pv2 V5.XRUGGEDCOM RS900M-GETS-C01RUGGEDCOM RS900 (32M) V5.XRUGGEDCOM M2200FRUGGEDCOM RP110RUGGEDCOM RSG2200FRUGGEDCOM i801RUGGEDCOM RSG2100P (32M) V5.XRUGGEDCOM RS416v2 V4.X
CWE ID-CWE-203
Observable Discrepancy
CWE ID-CWE-208
Observable Timing Discrepancy
CVE-2021-42019
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.9||MEDIUM
EPSS-0.56% / 67.13%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-12 Aug, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. Within a third-party component, the process to allocate partition size fails to check memory boundaries. Therefore, if a large amount is requested by an attacker, due to an integer-wrap around, it could result in a small size being allocated instead.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rs969ruggedcom_rs910ruggedcom_rsg2100ruggedcom_rsg2300pruggedcom_rs930lruggedcom_rsg907rruggedcom_rsg910cruggedcom_rs416ruggedcom_rs900wruggedcom_i801ruggedcom_rosruggedcom_m2100ruggedcom_rmcruggedcom_i800ruggedcom_rst2228ruggedcom_rs930wruggedcom_rmc8388ruggedcom_rsg2200ruggedcom_rs900ruggedcom_rs401ruggedcom_rs8000truggedcom_rsg909rruggedcom_rp110ruggedcom_rs910lruggedcom_i802ruggedcom_m969ruggedcom_rs910wruggedcom_rsg2100pruggedcom_rs8000ruggedcom_rst916pruggedcom_rs900gpruggedcom_rs900lruggedcom_rmc40ruggedcom_rsl910ruggedcom_rmc41ruggedcom_rsg920pruggedcom_rs920wruggedcom_rs416v2ruggedcom_rs8000aruggedcom_rsg2300ruggedcom_rst916cruggedcom_m2200ruggedcom_rs400ruggedcom_rst2228pruggedcom_rmc20ruggedcom_rs8000hruggedcom_rsg908cruggedcom_i803ruggedcom_rsg2488ruggedcom_rs900gruggedcom_rsg2288ruggedcom_rs920lruggedcom_rs940gruggedcom_rmc30RUGGEDCOM RS8000RUGGEDCOM RS900LRUGGEDCOM RSG2300 V4.XRUGGEDCOM RS900MNC-STND-XX-C01RUGGEDCOM RSG920P V4.XRUGGEDCOM RS401NCRUGGEDCOM RSG2100PNC (32M) V4.XRUGGEDCOM RS920LNCRUGGEDCOM RS910LRUGGEDCOM RS930WRUGGEDCOM RSG2100NC(32M) V5.XRUGGEDCOM RSG2100 (32M) V5.XRUGGEDCOM RSG2288NC V5.XRUGGEDCOM RS416Pv2 V4.XRUGGEDCOM RS1600RUGGEDCOM i801NCRUGGEDCOM RS940GRUGGEDCOM RSG2100NC(32M) V4.XRUGGEDCOM i800NCRUGGEDCOM RS910RUGGEDCOM RSG908CRUGGEDCOM RS8000NCRUGGEDCOM RS400FRUGGEDCOM RS900NC(32M) V4.XRUGGEDCOM RS920LRUGGEDCOM RMC8388 V4.XRUGGEDCOM RS8000HRUGGEDCOM RS900LNCRUGGEDCOM RS8000TRUGGEDCOM RS910NCRUGGEDCOM RS416PFRUGGEDCOM RS900GRUGGEDCOM M2100FRUGGEDCOM RS900M-STND-XXRUGGEDCOM RS900WRUGGEDCOM RMC8388 V5.XRUGGEDCOM RS900MNC-STND-XXRUGGEDCOM RSG2100PNC (32M) V5.XRUGGEDCOM RSG910CRUGGEDCOM RSG2300PFRUGGEDCOM RSG2288 V4.XRUGGEDCOM RS1600NCRUGGEDCOM RS969RUGGEDCOM RS900 (32M) V4.XRUGGEDCOM RSG909RRUGGEDCOM RS416FRUGGEDCOM RS900GPFRUGGEDCOM RSG2100PRUGGEDCOM RS930LNCRUGGEDCOM RS416PRUGGEDCOM RSG920P V5.XRUGGEDCOM RSG2200NCRUGGEDCOM RS8000HNCRUGGEDCOM RSG2300PNC V5.XRUGGEDCOM RSG2288 V5.XRUGGEDCOM RS1600FRUGGEDCOM RS416NCRUGGEDCOM RS930LRUGGEDCOM RSG907RRUGGEDCOM RSG2300P V5.XRUGGEDCOM RS910WRUGGEDCOM RSG2300 V5.XRUGGEDCOM RS940GNCRUGGEDCOM RS900GNCRUGGEDCOM RSG2100P (32M) V4.XRUGGEDCOM RMC8388NC V5.XRUGGEDCOM RS940GFRUGGEDCOM RS910LNCRUGGEDCOM RSG2288NC V4.XRUGGEDCOM RSG2488 V5.XRUGGEDCOM RMC30RUGGEDCOM RS900GFRUGGEDCOM RS8000ANCRUGGEDCOM RMC8388NC V4.XRUGGEDCOM RS1600TRUGGEDCOM M969FRUGGEDCOM RS900G (32M) V5.XRUGGEDCOM RS400NCRUGGEDCOM RS900MNC-GETS-C01RUGGEDCOM RS900M-GETS-C01RUGGEDCOM RSG2488NC V4.XRUGGEDCOM M2200FRUGGEDCOM RP110RUGGEDCOM i801RUGGEDCOM RS416v2 V4.XRUGGEDCOM RS416NCv2 V4.XRUGGEDCOM RS8000TNCRUGGEDCOM RSG2300P V4.XRUGGEDCOM RS416v2 V5.XRUGGEDCOM RS920WRUGGEDCOM RS900FRUGGEDCOM M2200RUGGEDCOM RS900MNC-GETS-XXRUGGEDCOM RSG2300NC V5.XRUGGEDCOM RS900GNC(32M) V4.XRUGGEDCOM RS900RUGGEDCOM RSG2100RUGGEDCOM M969NCRUGGEDCOM RS416PNCRUGGEDCOM RS1600FNCRUGGEDCOM RS400RUGGEDCOM RS900NC(32M) V5.XRUGGEDCOM RS1600TNCRUGGEDCOM RS900G (32M) V4.XRUGGEDCOM M969RUGGEDCOM RS416PNCv2 V4.XRUGGEDCOM M2200NCRUGGEDCOM RS8000ARUGGEDCOM i803RUGGEDCOM RSG2100PNCRUGGEDCOM RSG920PNC V5.XRUGGEDCOM RSG2100NCRUGGEDCOM RSG2488FRUGGEDCOM RP110NCRUGGEDCOM RSG2200RUGGEDCOM RSG2488NC V5.XRUGGEDCOM RSL910NCRUGGEDCOM RS969NCRUGGEDCOM RS416RUGGEDCOM RST2228PRUGGEDCOM i800RUGGEDCOM RS900M-STND-C01RUGGEDCOM RS900M-GETS-XXRUGGEDCOM RST916PRUGGEDCOM RS416PNCv2 V5.XRUGGEDCOM RS416NCv2 V5.XRUGGEDCOM RSG2100 (32M) V4.XRUGGEDCOM RSL910RUGGEDCOM RSG2100PFRUGGEDCOM RS900GPRUGGEDCOM RST916CRUGGEDCOM RS900GPNCRUGGEDCOM RSG2100FRUGGEDCOM RSG2488 V4.XRUGGEDCOM i802RUGGEDCOM RS900GNC(32M) V5.XRUGGEDCOM RST2228RUGGEDCOM RS401RUGGEDCOM RSG2300NC V4.XRUGGEDCOM RSG920PNC V4.XRUGGEDCOM i802NCRUGGEDCOM i803NCRUGGEDCOM M2100RUGGEDCOM RSG2300FRUGGEDCOM RSG2300PNC V4.XRUGGEDCOM RS900NCRUGGEDCOM RS416Pv2 V5.XRUGGEDCOM RMC30NCRUGGEDCOM RS900 (32M) V5.XRUGGEDCOM RSG2200FRUGGEDCOM M2100NCRUGGEDCOM RSG2100P (32M) V5.X
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2021-41769
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.47% / 63.80%
||
7 Day CHG~0.00%
Published-11 Jan, 2022 | 11:27
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions < V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information.

Action-Not Available
Vendor-Siemens AG
Product-6md857sa87_firmware6md867um856md89_firmware7sl87_firmware7sk85_firmware7ut867ss857sa877ke85_firmware7sd87_firmware6mu85_firmware6md896mu857st857vk877sd86_firmware7sl82_firmware7ut857sj81_firmware7ve85_firmware7st85_firmware7sl827sd867ke857sa86_firmware7sx8007ut86_firmware6md85_firmware7sk857sk827sx800_firmware7sd877sx85_firmware6md86_firmware7sk82_firmware7sa867sj827sj857sj86_firmware7sl86_firmware7sj817ut82_firmware7ut85_firmware7sj82_firmware7um85_firmware7ve857ut877vk87_firmware7sa827sj85_firmware7sl867sx857sd827ut87_firmware7ut827sj867sd82_firmware7sl877sa82_firmware7ss85_firmwareSIPROTEC 5 7SD82 devices (CPU variant CP100)SIPROTEC 5 6MD86 devices (CPU variant CP300)SIPROTEC 5 7VE85 devices (CPU variant CP300)SIPROTEC 5 7UT87 devices (CPU variant CP300)SIPROTEC 5 7ST85 devices (CPU variant CP300)SIPROTEC 5 7SL82 devices (CPU variant CP100)SIPROTEC 5 7UT82 devices (CPU variant CP100)SIPROTEC 5 6MU85 devices (CPU variant CP300)SIPROTEC 5 7SK82 devices (CPU variant CP100)SIPROTEC 5 7SK85 devices (CPU variant CP300)SIPROTEC 5 7UT86 devices (CPU variant CP300)SIPROTEC 5 7SA82 devices (CPU variant CP100)SIPROTEC 5 7VK87 devices (CPU variant CP300)SIPROTEC 5 7SD86 devices (CPU variant CP300)SIPROTEC 5 7SJ85 devices (CPU variant CP300)SIPROTEC 5 7SJ82 devices (CPU variant CP100)SIPROTEC 5 7SL87 devices (CPU variant CP300)SIPROTEC 5 7SX85 devices (CPU variant CP300)SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050)SIPROTEC 5 6MD85 devices (CPU variant CP300)SIPROTEC 5 7UM85 devices (CPU variant CP300)SIPROTEC 5 7SA86 devices (CPU variant CP300)SIPROTEC 5 7UT85 devices (CPU variant CP300)SIPROTEC 5 7SL86 devices (CPU variant CP300)SIPROTEC 5 7KE85 devices (CPU variant CP300)SIPROTEC 5 7SJ86 devices (CPU variant CP300)SIPROTEC 5 7SS85 devices (CPU variant CP300)SIPROTEC 5 7SD87 devices (CPU variant CP300)SIPROTEC 5 7SA87 devices (CPU variant CP300)SIPROTEC 5 6MD89 devices (CPU variant CP300)SIPROTEC 5 7SJ81 devices (CPU variant CP100)
CWE ID-CWE-20
Improper Input Validation
CVE-2021-42018
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.9||MEDIUM
EPSS-0.60% / 68.48%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-12 Aug, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. Within a third-party component, whenever memory allocation is requested, the out of bound size is not checked. Therefore, if size exceeding the expected allocation is assigned, it could allocate a smaller buffer instead. If an attacker were to exploit this, they could cause a heap overflow.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rs969ruggedcom_rs910ruggedcom_rsg2100ruggedcom_rsg2300pruggedcom_rs930lruggedcom_rsg907rruggedcom_rsg910cruggedcom_rs416ruggedcom_rs900wruggedcom_i801ruggedcom_rosruggedcom_m2100ruggedcom_rmcruggedcom_i800ruggedcom_rst2228ruggedcom_rs930wruggedcom_rmc8388ruggedcom_rsg2200ruggedcom_rs900ruggedcom_rs401ruggedcom_rs8000truggedcom_rsg909rruggedcom_rp110ruggedcom_rs910lruggedcom_i802ruggedcom_m969ruggedcom_rs910wruggedcom_rsg2100pruggedcom_rs8000ruggedcom_rst916pruggedcom_rs900gpruggedcom_rs900lruggedcom_rmc40ruggedcom_rsl910ruggedcom_rmc41ruggedcom_rsg920pruggedcom_rs920wruggedcom_rs416v2ruggedcom_rs8000aruggedcom_rsg2300ruggedcom_rst916cruggedcom_m2200ruggedcom_rs400ruggedcom_rst2228pruggedcom_rmc20ruggedcom_rs8000hruggedcom_rsg908cruggedcom_i803ruggedcom_rsg2488ruggedcom_rs900gruggedcom_rsg2288ruggedcom_rs920lruggedcom_rs940gruggedcom_rmc30RUGGEDCOM RS8000RUGGEDCOM RS900LRUGGEDCOM RSG2300 V4.XRUGGEDCOM RS900MNC-STND-XX-C01RUGGEDCOM RSG920P V4.XRUGGEDCOM RS401NCRUGGEDCOM RSG2100PNC (32M) V4.XRUGGEDCOM RS920LNCRUGGEDCOM RS910LRUGGEDCOM RS930WRUGGEDCOM RSG2100NC(32M) V5.XRUGGEDCOM RSG2100 (32M) V5.XRUGGEDCOM RSG2288NC V5.XRUGGEDCOM RS416Pv2 V4.XRUGGEDCOM RS1600RUGGEDCOM i801NCRUGGEDCOM RS940GRUGGEDCOM RSG2100NC(32M) V4.XRUGGEDCOM i800NCRUGGEDCOM RS910RUGGEDCOM RSG908CRUGGEDCOM RS8000NCRUGGEDCOM RS400FRUGGEDCOM RS900NC(32M) V4.XRUGGEDCOM RS920LRUGGEDCOM RMC8388 V4.XRUGGEDCOM RS8000HRUGGEDCOM RS900LNCRUGGEDCOM RS8000TRUGGEDCOM RS910NCRUGGEDCOM RS416PFRUGGEDCOM RS900GRUGGEDCOM M2100FRUGGEDCOM RS900M-STND-XXRUGGEDCOM RS900WRUGGEDCOM RMC8388 V5.XRUGGEDCOM RS900MNC-STND-XXRUGGEDCOM RSG2100PNC (32M) V5.XRUGGEDCOM RSG910CRUGGEDCOM RSG2300PFRUGGEDCOM RSG2288 V4.XRUGGEDCOM RS1600NCRUGGEDCOM RS969RUGGEDCOM RS900 (32M) V4.XRUGGEDCOM RSG909RRUGGEDCOM RS416FRUGGEDCOM RS900GPFRUGGEDCOM RSG2100PRUGGEDCOM RS930LNCRUGGEDCOM RS416PRUGGEDCOM RSG920P V5.XRUGGEDCOM RSG2200NCRUGGEDCOM RS8000HNCRUGGEDCOM RSG2300PNC V5.XRUGGEDCOM RSG2288 V5.XRUGGEDCOM RS1600FRUGGEDCOM RS416NCRUGGEDCOM RS930LRUGGEDCOM RSG907RRUGGEDCOM RSG2300P V5.XRUGGEDCOM RS910WRUGGEDCOM RSG2300 V5.XRUGGEDCOM RS940GNCRUGGEDCOM RS900GNCRUGGEDCOM RSG2100P (32M) V4.XRUGGEDCOM RMC8388NC V5.XRUGGEDCOM RS940GFRUGGEDCOM RS910LNCRUGGEDCOM RSG2288NC V4.XRUGGEDCOM RSG2488 V5.XRUGGEDCOM RMC30RUGGEDCOM RS900GFRUGGEDCOM RS8000ANCRUGGEDCOM RMC8388NC V4.XRUGGEDCOM RS1600TRUGGEDCOM M969FRUGGEDCOM RS900G (32M) V5.XRUGGEDCOM RS400NCRUGGEDCOM RS900MNC-GETS-C01RUGGEDCOM RS900M-GETS-C01RUGGEDCOM RSG2488NC V4.XRUGGEDCOM M2200FRUGGEDCOM RP110RUGGEDCOM i801RUGGEDCOM RS416v2 V4.XRUGGEDCOM RS416NCv2 V4.XRUGGEDCOM RS8000TNCRUGGEDCOM RSG2300P V4.XRUGGEDCOM RS416v2 V5.XRUGGEDCOM RS920WRUGGEDCOM RS900FRUGGEDCOM M2200RUGGEDCOM RS900MNC-GETS-XXRUGGEDCOM RSG2300NC V5.XRUGGEDCOM RS900GNC(32M) V4.XRUGGEDCOM RS900RUGGEDCOM RSG2100RUGGEDCOM M969NCRUGGEDCOM RS416PNCRUGGEDCOM RS1600FNCRUGGEDCOM RS400RUGGEDCOM RS900NC(32M) V5.XRUGGEDCOM RS1600TNCRUGGEDCOM RS900G (32M) V4.XRUGGEDCOM M969RUGGEDCOM RS416PNCv2 V4.XRUGGEDCOM M2200NCRUGGEDCOM RS8000ARUGGEDCOM i803RUGGEDCOM RSG2100PNCRUGGEDCOM RSG920PNC V5.XRUGGEDCOM RSG2100NCRUGGEDCOM RSG2488FRUGGEDCOM RP110NCRUGGEDCOM RSG2200RUGGEDCOM RSG2488NC V5.XRUGGEDCOM RSL910NCRUGGEDCOM RS969NCRUGGEDCOM RS416RUGGEDCOM RST2228PRUGGEDCOM i800RUGGEDCOM RS900M-STND-C01RUGGEDCOM RS900M-GETS-XXRUGGEDCOM RST916PRUGGEDCOM RS416PNCv2 V5.XRUGGEDCOM RS416NCv2 V5.XRUGGEDCOM RSG2100 (32M) V4.XRUGGEDCOM RSL910RUGGEDCOM RSG2100PFRUGGEDCOM RS900GPRUGGEDCOM RST916CRUGGEDCOM RS900GPNCRUGGEDCOM RSG2100FRUGGEDCOM RSG2488 V4.XRUGGEDCOM i802RUGGEDCOM RS900GNC(32M) V5.XRUGGEDCOM RST2228RUGGEDCOM RS401RUGGEDCOM RSG2300NC V4.XRUGGEDCOM RSG920PNC V4.XRUGGEDCOM i802NCRUGGEDCOM i803NCRUGGEDCOM M2100RUGGEDCOM RSG2300FRUGGEDCOM RSG2300PNC V4.XRUGGEDCOM RS900NCRUGGEDCOM RS416Pv2 V5.XRUGGEDCOM RMC30NCRUGGEDCOM RS900 (32M) V5.XRUGGEDCOM RSG2200FRUGGEDCOM M2100NCRUGGEDCOM RSG2100P (32M) V5.X
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-42021
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-1.00% / 76.02%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siveillance Video DLNA Server (2019 R1), Siveillance Video DLNA Server (2019 R2), Siveillance Video DLNA Server (2019 R3), Siveillance Video DLNA Server (2020 R1), Siveillance Video DLNA Server (2020 R2), Siveillance Video DLNA Server (2020 R3), Siveillance Video DLNA Server (2021 R1). The affected application contains a path traversal vulnerability that could allow to read arbitrary files on the server that are outside the application’s web document directory. An unauthenticated remote attacker could exploit this issue to access sensitive information for subsequent attacks.

Action-Not Available
Vendor-Siemens AG
Product-siveillance_video_management_software_2019_r1siveillance_video_management_software_2019_r3siveillance_video_dlna_serversiveillance_video_management_software_2020_r1siveillance_video_management_software_2020_r2siveillance_video_management_software_2019_r2Siveillance Video DLNA Server
CWE ID-CWE-26
Path Traversal: '/dir/../filename'
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2017-14491
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-52.38% / 97.84%
||
7 Day CHG~0.00%
Published-02 Oct, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response.

Action-Not Available
Vendor-thekelleysn/aHuawei Technologies Co., Ltd.Debian GNU/LinuxSUSERed Hat, Inc.Aruba NetworksSynology, Inc.NVIDIA CorporationArista Networks, Inc.Canonical Ltd.openSUSEMicrosoft CorporationSiemens AG
Product-enterprise_linux_desktopruggedcom_rm1224_firmwarescalance_w1750d_firmwarescalance_s615enterprise_linux_workstationlinux_for_tegradnsmasqlinux_enterprise_serverleaprouter_managerlinux_enterprise_point_of_salearubaosenterprise_linux_serverdebian_linuxjetson_tk1scalance_s615_firmwaregeforce_experiencelinux_enterprise_debuginfoeosscalance_m-800diskstation_managerhonor_v9_play_firmwarejetson_tx1scalance_w1750druggedcom_rm1224ubuntu_linuxhonor_v9_playscalance_m-800_firmwarewindowsn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-40356
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.31% / 53.36%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:48
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_visualizationTeamcenter V12.4Teamcenter V13.0Teamcenter V13.2Teamcenter V13.1
CWE ID-CWE-611
Improper Restriction of XML External Entity Reference
CVE-2021-40358
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.9||CRITICAL
EPSS-0.58% / 67.84%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7SIMATIC WinCC V15 and earlierSIMATIC WinCC V17SIMATIC PCS 7 V9.1SIMATIC PCS 7 V9.0SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC WinCC V16SIMATIC PCS 7 V8.2
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-43504
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.6||CRITICAL
EPSS-0.23% / 45.86%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 11:03
Updated-08 Jan, 2025 | 16:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in COMOS (All versions < V10.4.4). Ptmcast executable used for testing cache validation service in affected application is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-comosCOMOS
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2023-43625
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.99% / 76.00%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Amesim (All versions < V2021.1). The affected application contains a SOAP endpoint that could allow an unauthenticated remote attacker to perform DLL injection and execute arbitrary code in the context of the affected application process.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_amesimSimcenter Amesim
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2017-12734
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.38% / 58.61%
||
7 Day CHG~0.00%
Published-30 Aug, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.

Action-Not Available
Vendor-Siemens AG
Product-logo\!8_bm_fs-05_firmwarelogo\!8_bm_fs-05LOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-895
Not Available
CVE-2017-5689
Matching Score-8
Assigner-Intel Corporation
ShareView Details
Matching Score-8
Assigner-Intel Corporation
CVSS Score-9.8||CRITICAL
EPSS-94.30% / 99.94%
||
7 Day CHG~0.00%
Published-02 May, 2017 | 14:00
Updated-30 Jul, 2025 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-07-28||Apply updates per vendor instructions.

An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT).

Action-Not Available
Vendor-Intel CorporationSiemens AGHewlett Packard Enterprise (HPE)
Product-simatic_ipc627dsimatic_pcs_7_ipc647csimatic_ipc827d_firmwaresimatic_pcs_7_ipc677c_firmwaresimotion_p320-4_sproliant_ml10_gen9_server_firmwaresimatic_ipc827csimatic_ipc547gsimatic_ipc477d_firmwaresimatic_field_pg_m4_firmwaresimatic_pcs_7_ipc647c_firmwaresimatic_pcs_7_ipc847csimatic_pcs_7_ipc677csimatic_itp1000_firmwaresimatic_ipc847c_firmwaresimatic_ipc647c_firmwaresimatic_ipc427dsimatic_pcs_7_ipc477d_firmwaresimatic_pcs_7_ipc547g_firmwaresinumerik_pcu_50.5-psimatic_pcs_7_ipc847dsimatic_ipc647d_firmwaresimatic_pcs_7_ipc627c_firmwaresimatic_ipc477dsimatic_ipc547g_firmwaresinumerik_pcu50.5-p_firmwaresimatic_ipc477e_firmwaresimatic_pcs_7_ipc427e_firmwaresimatic_pcs_7_ipc627csimatic_ipc647dproliant_ml10_gen9_serversimatic_pcs_7_ipc547d_firmwaresimatic_ipc477esimotion_p320-4_s_firmwaresimatic_ipc547esimatic_field_pg_m3_firmwaresimatic_pcs_7_ipc547e_firmwaresimatic_ipc427esimatic_pcs_7_ipc427esimatic_ipc677csimatic_pcs_7_ipc647dsimatic_pcs_7_ipc847c_firmwareactive_management_technology_firmwaresimatic_pcs_7_ipc647d_firmwaresimatic_ipc427e_firmwaresimatic_ipc547e_firmwaresimatic_ipc827dsimatic_ipc547d_firmwaresimatic_ipc847csimatic_field_pg_m5simatic_ipc647csimatic_ipc547dsimatic_ipc627d_firmwaresimatic_pcs_7_ipc547gsimatic_field_pg_m3simatic_ipc677c_firmwaresimatic_ipc847dsimatic_ipc627csimatic_field_pg_m4simatic_pcs_7_ipc547esimatic_ipc677dsimatic_pcs_7_ipc477dsimatic_ipc627c_firmwaresimatic_pcs_7_ipc547dsimatic_pcs_7_ipc847d_firmwaresimatic_itp1000simatic_field_pg_m5_firmwaresimatic_ipc427d_firmwaresimatic_ipc847d_firmwaresimatic_ipc677d_firmwaresimatic_ipc827c_firmwareIntel Active Mangement Technology, Intel Small Business Technology, Intel Standard ManageabilityActive Management Technology (AMT), Small Business Technology (SBT), and Standard Manageability
CWE ID-CWE-269
Improper Privilege Management
CVE-2021-40359
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.7||HIGH
EPSS-0.47% / 63.58%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_route_controlsimaticpcs_7simatic_net_pcsimatic_batchSIMATIC NET PC Software V14SIMATIC WinCC V15 and earlierSIMATIC WinCC V17SIMATIC NET PC Software V15SIMATIC PCS 7 V9.0SIMATIC PCS 7 V9.1OpenPCS 7 V9.0SIMATIC BATCH V9.1OpenPCS 7 V8.2SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC Route Control V9.1SIMATIC BATCH V8.2SIMATIC Route Control V8.2SIMATIC Route Control V9.0OpenPCS 7 V9.1SIMATIC NET PC Software V16SIMATIC BATCH V9.0SIMATIC WinCC V16SIMATIC PCS 7 V8.2SIMATIC NET PC Software V17
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2012-3030
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5||MEDIUM
EPSS-0.52% / 65.76%
||
7 Day CHG~0.00%
Published-18 Sep, 2012 | 14:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccsimatic_pcs7n/a
CVE-2023-37372
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-27 Feb, 2025 | 21:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an unauthenticated remote attackers to execute arbitrary SQL queries on the server database.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOW
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-39275
Matching Score-8
Assigner-Apache Software Foundation
ShareView Details
Matching Score-8
Assigner-Apache Software Foundation
CVSS Score-9.8||CRITICAL
EPSS-44.80% / 97.49%
||
7 Day CHG~0.00%
Published-16 Sep, 2021 | 14:40
Updated-01 May, 2025 | 15:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ap_escape_quotes buffer overflow

ap_escape_quotes() may write beyond the end of a buffer when given malicious input. No included modules pass untrusted data to these functions, but third-party / external modules may. This issue affects Apache HTTP Server 2.4.48 and earlier.

Action-Not Available
Vendor-Fedora ProjectOracle CorporationThe Apache Software FoundationDebian GNU/LinuxNetApp, Inc.Siemens AG
Product-debian_linuxfedorasinec_nmshttp_servercloud_backupsinema_serverzfs_storage_appliance_kitinstantis_enterprisetrackstoragegridclustered_data_ontapApache HTTP Server
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-36380
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.06% / 19.80%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)). The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected.

Action-Not Available
Vendor-Siemens AG
Product-cp-8050_firmwarecp-8050cp-8031_firmwarecp-8031CP-8031 MASTER MODULECP-8050 MASTER MODULE
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2021-37716
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.58% / 80.86%
||
7 Day CHG~0.00%
Published-07 Sep, 2021 | 12:02
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote buffer overflow vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.4; Prior to 8.7.1.2, 8.6.0.8, 8.5.0.12, 8.3.0.15. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaossd-wanscalance_w1750d_firmwarescalance_w1750dAruba SD-WAN Software and Gateways; Aruba Operating System Software
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2016-2031
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.97% / 75.75%
||
7 Day CHG~0.00%
Published-31 Jan, 2020 | 19:33
Updated-05 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple vulnerabilities exists in Aruba Instate before 4.1.3.0 and 4.2.3.1 due to insufficient validation of user-supplied input and insufficient checking of parameters, which could allow a malicious user to bypass security restrictions, obtain sensitive information, perform unauthorized actions and execute arbitrary code.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-aruba_instantairwavearubaosscalance_w1750d_firmwarescalance_w1750dn/a
CWE ID-CWE-20
Improper Input Validation
CVE-2021-37726
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.32% / 79.05%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 14:06
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-aruba_instantscalance_w1750d_firmwarescalance_w1750dHPE Aruba Instant (IAP)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-37184
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.52% / 65.72%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Industrial Edge Management (All versions < V1.3). An unauthenticated attacker could change the the password of any user in the system under certain circumstances. With this an attacker could impersonate any valid user on an affected system.

Action-Not Available
Vendor-Siemens AG
Product-industrial_edge_managementIndustrial Edge Management
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CVE-2021-29998
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.19% / 77.96%
||
7 Day CHG~0.00%
Published-13 Apr, 2021 | 16:16
Updated-03 Aug, 2024 | 22:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Wind River VxWorks before 6.5. There is a possible heap overflow in dhcp client.

Action-Not Available
Vendor-windrivern/aSiemens AG
Product-scalance_xf206-1_firmwarescalance_x208_pro_firmwarescalance_x201-3p_irtscalance_x212-2ldscalance_x206-1scalance_x300simatic_rf_182c_firmwarescalance_x201-3p_irt_proscalance_x204-2fmscalance_x208scalance_x202-2p_irtsimatic_rf_181_eip_firmwarevxworksscalance_x206-1_firmwaresinamics_perfect_harmony_gh180ruggedcom_win_subscriber_station_firmwarescalance_xf204-2scalance_x204_irtscalance_x202-2_irtscalance_xf204_firmwarescalance_xf204-2ba_irtscalance_x204-2ld_firmwarescalance_x212-2_firmwarescalance_x204_irt_proscalance_xf208_firmwarescalance_xf204-2_firmwarescalance_x208_proscalance_x202-2p_irt_proscalance_xf202-2p_irtscalance_x204-2fm_firmwarescalance_x204-2tsscalance_x202-2_irt_firmwarescalance_xf204scalance_x206-1ldscalance_x200-4_p_irtscalance_xf204_irt_firmwarescalance_xf201-3p_irtscalance_xf204_irtruggedcom_win_subscriber_stationscalance_x204-2ldscalance_xf208scalance_x201-3p_irt_firmwarescalance_x202-2p_irt_pro_firmwarescalance_xf204-2ba_irt_firmwarescalance_x204-2ld_ts_firmwarescalance_x300_firmwarescalance_x204-2ld_tsscalance_x204-2scalance_x408scalance_x224scalance_x204-2_firmwarescalance_xf206-1scalance_x202-2p_irt_firmwarescalance_x206-1ld_firmwaresinamics_perfect_harmony_gh180_firmwarescalance_x212-2ld_firmwarescalance_x204_irt_firmwarescalance_x408_firmwarescalance_x212-2scalance_x200-4_p_irt_firmwarescalance_x204-2ts_firmwarescalance_x216_firmwarescalance_xf202-2p_irt_firmwarescalance_x208_firmwaresimatic_rf_181_eipscalance_x204_irt_pro_firmwaresimatic_rf_182cscalance_x216scalance_xf201-3p_irt_firmwarescalance_x201-3p_irt_pro_firmwarescalance_x224_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2014-4682
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.23% / 45.77%
||
7 Day CHG~0.00%
Published-24 Jul, 2014 | 14:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_pcs7winccn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2023-28489
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.60% / 80.93%
||
7 Day CHG~0.00%
Published-11 Apr, 2023 | 09:03
Updated-13 Feb, 2025 | 16:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter “Remote Operation” is enabled. The parameter is disabled by default. The vulnerability could allow an unauthenticated remote attacker to perform arbitrary code execution on the device.

Action-Not Available
Vendor-Siemens AG
Product-cp-8050_firmwarecp-8031cp-8031_firmwarecp-8050CP-8031 MASTER MODULECP-8050 MASTER MODULE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-11656
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-9.40% / 92.47%
||
7 Day CHG~0.00%
Published-09 Apr, 2020 | 02:49
Updated-04 Aug, 2024 | 11:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In SQLite through 3.31.1, the ALTER TABLE implementation has a use-after-free, as demonstrated by an ORDER BY clause that belongs to a compound SELECT statement.

Action-Not Available
Vendor-sqliten/aNetApp, Inc.Oracle CorporationTenable, Inc.Siemens AG
Product-sinec_infrastructure_network_servicescommunications_messaging_serverontap_select_deploy_administration_utilitysqlitecommunications_network_charging_and_controlzfs_storage_appliance_kitoutside_in_technologytenable.schyperion_infrastructure_technologymysql_workbenchenterprise_manager_ops_centermysqln/a
CWE ID-CWE-416
Use After Free
CVE-2017-12737
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.30% / 52.67%
||
7 Day CHG~0.00%
Published-15 Nov, 2017 | 08:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the network.

Action-Not Available
Vendor-n/aSiemens AG
Product-sm-2556sm-2556_firmwareSiemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-19646
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-21.53% / 95.50%
||
7 Day CHG~0.00%
Published-09 Dec, 2019 | 18:36
Updated-05 Aug, 2024 | 02:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

pragma.c in SQLite through 3.30.1 mishandles NOT NULL in an integrity_check PRAGMA command in certain cases of generated columns.

Action-Not Available
Vendor-sqliten/aNetApp, Inc.Oracle CorporationTenable, Inc.Siemens AG
Product-sinec_infrastructure_network_servicescloud_backupsqliteontap_select_deploy_administration_utilitytenable.scmysql_workbenchn/a
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2007-1913
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.64% / 69.64%
||
7 Day CHG~0.00%
Published-10 Apr, 2007 | 23:00
Updated-07 Aug, 2024 | 13:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The TRUSTED_SYSTEM_SECURITY function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to verify the existence of users and groups on systems and domains via unspecified vectors, a different vulnerability than CVE-2006-6010. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended.

Action-Not Available
Vendor-n/aMicrosoft CorporationSAP SEApple Inc.Siemens AGSun Microsystems (Oracle Corporation)IBM CorporationLinux Kernel Organization, IncHP Inc.
Product-os_400windows_serversolarislinux_kernelracfhp-uxtru64reliant_unixmacosrfc_libraryaixn/a
CVE-2025-40736
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.11% / 30.92%
||
7 Day CHG~0.00%
Published-08 Jul, 2025 | 10:34
Updated-21 Aug, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application exposes an endpoint that allows an unauthorized modification of administrative credentials. This could allow an unauthenticated attacker to reset the superadmin password and gain full control of the application (ZDI-CAN-26569).

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2025-40566
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.07% / 22.69%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:38
Updated-22 Aug, 2025 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout.

Action-Not Available
Vendor-Siemens AG
Product-simatic_pcs_neoSIMATIC PCS neo V5.0SIMATIC PCS neo V4.1
CWE ID-CWE-613
Insufficient Session Expiration
CVE-2021-37175
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.24%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices do not properly handle permissions to traverse the file system. If exploited, an attacker could gain access to an overview of the complete file system on the affected devices.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_rx1511ruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx1512_firmwareRUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-280
Improper Handling of Insufficient Permissions or Privileges
CWE ID-CWE-755
Improper Handling of Exceptional Conditions
CVE-2019-19299
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.46% / 63.19%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 19:16
Updated-05 Aug, 2024 | 02:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0 < V5.0.2), SiNVR/SiVMS Video Server (All versions >= V5.0.2). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server applies weak cryptography when exposing device (camera) passwords. This could allow an unauthenticated remote attacker to read and decrypt the passwords and conduct further attacks.

Action-Not Available
Vendor-Siemens AG
Product-sinvr\/sivms_video_serverSiNVR/SiVMS Video Server
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2019-18327
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.84%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18316
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.71% / 81.60%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted packets to 1099/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2020-10055
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.70% / 85.31%
||
7 Day CHG~0.00%
Published-14 Aug, 2020 | 15:24
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Desigo CC (V4.x), Desigo CC (V3.x), Desigo CC Compact (V4.x), Desigo CC Compact (V3.x). Affected applications are delivered with a 3rd party component (BIRT) that contains a remote code execution vulnerability if the Advanced Reporting Engine is enabled. The vulnerability could allow a remote unauthenticated attacker to execute arbitrary commands on the server with SYSTEM privileges.

Action-Not Available
Vendor-Siemens AG
Product-desigo_consumption_control_compactdesigo_consumption_controlDesigo CC CompactDesigo CC
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2019-18330
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.84%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, and CVE-2019-18329. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18323
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.84%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18296
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.55% / 84.92%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18289, CVE-2019-18293, and CVE-2019-18295. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18313
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-3.95% / 87.89%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could gain remote code execution by sending specifically crafted objects to one of the RPC services. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2019-18334
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.17% / 38.09%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to enumerate valid user names by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-18331
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.17% / 38.09%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to path and filenames on the server by sending specifically crafted packets to 1099/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2020-10037
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.68%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). By performing a flooding attack against the web server, an attacker might be able to gain read access to the device's memory, possibly revealing confidential information.

Action-Not Available
Vendor-Siemens AG
Product-sicam_t_firmwaresicam_mmusicam_sgu_firmwaresicam_mmu_firmwaresicam_sgusicam_tSICAM TSICAM MMUSICAM SGU
CWE ID-CWE-125
Out-of-bounds Read
CVE-2019-18335
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.17% / 38.09%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to gain access to logs and configuration files by sending specifically crafted packets to 80/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2020-10042
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.30% / 78.89%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). A buffer overflow in various positions of the web application might enable an attacker with access to the web application to execute arbitrary code over the network.

Action-Not Available
Vendor-Siemens AG
Product-sicam_t_firmwaresicam_mmusicam_sgu_firmwaresicam_mmu_firmwaresicam_sgusicam_tSICAM TSICAM MMUSICAM SGU
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2016-9155
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.92% / 75.04%
||
7 Day CHG~0.00%
Published-22 Nov, 2016 | 11:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The following SIEMENS branded IP Camera Models CCMW3025, CVMW3025-IR, CFMW3025 prior to version 1.41_SP18_S1; CCPW3025, CCPW5025 prior to version 0.1.73_S1; CCMD3025-DN18 prior to version v1.394_S1; CCID1445-DN18, CCID1445-DN28, CCID1145-DN36, CFIS1425, CCIS1425, CFMS2025, CCMS2025, CVMS2025-IR, CFMW1025, CCMW1025 prior to version v2635_SP1 could allow an attacker with network access to the web server to obtain administrative credentials under certain circumstances.

Action-Not Available
Vendor-n/aSiemens AG
Product-ccmw3025_firmwareccmd3025-dn18cvms2025-ir_firmwarecfms2025ccid1445-dn28_firmwareccmw1025_firmwarecvmw3025-ir_firmwareccid1445-dn36_firmwareccpw3025ccpw3025_firmwareccms2025_firmwareccid1445-dn28ccis1425_firmwareccmw3025cfms2025_firmwareccmd3025-dn18_firmwarecfmw1025cfmw3025_firmwareccmw1025ccid1445-dn36cfis1425_firmwareccms2025cfmw1025_firmwarecfmw3025cfis1425ccid1445-dn18_firmwareccis1425cvms2025-ircvmw3025-irccid1445-dn18SIEMENS-branded IP Cameras
CWE ID-CWE-284
Improper Access Control
CVE-2014-1698
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.73% / 71.87%
||
7 Day CHG~0.00%
Published-07 Feb, 2014 | 02:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_wincc_open_architecturen/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2019-18329
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.84%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18328
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.84%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write