D-Link DIR-620 devices, with a certain Rostelekom variant of firmware 1.0.37, have a hardcoded rostel account, which makes it easier for remote attackers to obtain access via a TELNET session.
Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
ONTAP Select Deploy administration utility versions 9.12.1.x, 9.13.1.x and 9.14.1.x contain hard-coded credentials that could allow an attacker to view Deploy configuration information and modify the account credentials.
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, the product uses hard-coded credentials, which may allow an attacker to connect to a specific port.
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
A vulnerability in Cisco Smart Licensing Utility (CSLU) could allow an unauthenticated, remote attacker to log into an affected system by using a static administrative credential. This vulnerability is due to an undocumented static user credential for an administrative account. An attacker could exploit this vulnerability by using the static credentials to login to the affected system. A successful exploit could allow the attacker to login to the affected system with administrative rights over the CSLU application API.
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
MASTER IPCAMERA01 3.3.4.2103 devices have a hardcoded password of cat1029 for the root account.
The secret value used for access to critical UDS services of the MIB3 infotainment is hardcoded in the firmware. Vulnerability discovered on Škoda Superb III (3V3) - 2.0 TDI manufactured in 2022.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
BB-ESWGP506-2SFP-T versions 1.01.09 and prior is vulnerable due to the use of hard-coded credentials, which may allow an attacker to gain unauthorized access and permit the execution of arbitrary code on the BB-ESWGP506-2SFP-T (versions 1.01.01 and prior).
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.
Swann SWWHD-INTCAM-HD devices have the twipc root password, leading to FTP access as root. NOTE: all affected customers were migrated by 2020-08-31.
Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters.
Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key.
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
Use of Hard-coded Credentials vulnerability in Samsung Electronics MagicINFO 9 Server allows Authentication Bypass.This issue affects MagicINFO 9 Server: less than 21.1080.0.
A hidden backdoor on PATLITE NH-FB Series devices with firmware version 1.45 or earlier, NH-FV Series devices with firmware version 1.10 or earlier, and NBM Series devices with firmware version 1.09 or earlier allow attackers to enable an SSH daemon via the "kankichi" or "kamiyo4" password to the _secret1.htm URI. Subsequently, the default password of root for the root account allows an attacker to conduct remote code execution and as a result take over the system.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The admin account has a blank password.
A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability.
Use of Hard-coded Credentials vulnerability in Samsung Electronics MagicINFO 9 Server allows Authentication Bypass.This issue affects MagicINFO 9 Server: less than 21.1080.0.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. There is a hardcoded Ak47@99 password for the factory~ account.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The CGIProxy.fcgi?cmd=setTelnetSwitch feature is authorized for the root user with a password of toor.
Milesight IP security cameras through 2016-11-14 have a hardcoded SSL private key under the /etc/config directory.
Milesight IP security cameras through 2016-11-14 have a default set of 10 privileged accounts with hardcoded credentials. They are accessible if the customer has not configured 10 actual user accounts.
Milesight IP security cameras through 2016-11-14 have a default root password in /etc/shadow that is the same across different customers' installations.
An issue was discovered on VOBOT CLOCK before 0.99.30 devices. An SSH server exists with a hardcoded vobot account that has root access.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
Hardcoded manufacturer credentials and an OS command injection vulnerability in the /cgi-bin/mft/ directory on ABUS TVIP TVIP20050 LM.1.6.18, TVIP10051 LM.1.6.18, TVIP11050 MG.1.6.03.05, TVIP20550 LM.1.6.18, TVIP10050 LM.1.6.18, TVIP11550 MG.1.6.03, TVIP21050 MG.1.6.03, and TVIP51550 MG.1.6.03 cameras allow remote attackers to execute code as root.
dirary0.js on D-Link DIR-140L, DIR-640L devices allows remote unauthenticated attackers to discover admin credentials.
atbox.htm on D-Link DSL-2770L devices allows remote unauthenticated attackers to discover admin credentials.
ExaGrid appliances with firmware before 4.8 P26 have a default password of (1) inflection for the root shell account and (2) support for the support account in the web interface, which allows remote attackers to obtain administrative access via an SSH or HTTP session.
Versions of DocuTrac QuicDoc and Office Therapy that ship with DTISQLInstaller.exe version 1.6.4.0 and prior contain three credentials with known passwords: QDMaster, OTMaster, and sa.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
Siklu EtherHaul radios before 3.7.1 and 6.x before 6.9.0 have a built-in, hidden root account, with an unchangeable password that is the same across all devices. This account is accessible via both SSH and the device's web interface and grants access to the underlying embedded Linux OS on the device, allowing full control over it.
An authentication bypass vulnerability in the /web/um_open_telnet.cgi endpoint in Nexxt Solutions NCM-X1800 Mesh Router firmware UV1.2.7 and below, allowing an attacker to remotely enable the Telnet service without authentication, bypassing security controls. The Telnet server is then accessible with hard-coded credentials, allowing attackers to gain administrative shell access and execute arbitrary commands on the device.
POSIM EVO 15.13 for Windows includes hardcoded database credentials for the "root" database user. "root" access to POSIM EVO's database may result in a breach of confidentiality, integrity, or availability or allow for attackers to remotely execute code on associated POSIM EVO clients.
NETGEAR Arlo base stations with firmware 1.7.5_6178 and earlier, Arlo Q devices with firmware 1.8.0_5551 and earlier, and Arlo Q Plus devices with firmware 1.8.1_6094 and earlier have a default password of 12345678, which makes it easier for remote attackers to obtain access after a factory reset or in a factory configuration.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Encrypted database credentials in LaborOfficeFree affecting version 19.10. This vulnerability allows an attacker to read and extract the username and password from the database of 'LOF_service.exe' and 'LaborOfficeFree.exe' located in the '%programfiles(x86)%\LaborOfficeFree\' directory. This user can log in remotely and has root-like privileges.
Austrian Archaeological Institute (AI) OpenAtlas v8.11.0 as discovered to contain a hardcoded Administrator password.
Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers' installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option.
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software before version 20240417.001 (from that version vulnerability is fixed).
Invoxia NVX220 devices allow TELNET access as admin with a default password.
A vulnerability in the Cisco Small Business Switches software could allow an unauthenticated, remote attacker to bypass the user authentication mechanism of an affected device. The vulnerability exists because under specific circumstances, the affected software enables a privileged user account without notifying administrators of the system. An attacker could exploit this vulnerability by using this account to log in to an affected device and execute commands with full admin rights. Cisco has not released software updates that address this vulnerability. This advisory will be updated with fixed software information once fixed software becomes available. There is a workaround to address this vulnerability.
A vulnerability in Cisco Video Surveillance Manager (VSM) Software running on certain Cisco Connected Safety and Security Unified Computing System (UCS) platforms could allow an unauthenticated, remote attacker to log in to an affected system by using the root account, which has default, static user credentials. The vulnerability is due to the presence of undocumented, default, static user credentials for the root account of the affected software on certain systems. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
go-admin (aka GO Admin) 2.0.12 uses the string go-admin as a production JWT key.