Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2020-35187

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-17 Dec, 2020 | 00:58
Updated At-04 Aug, 2024 | 17:02
Rejected At-
Credits

The official telegraf docker images before 1.9.4-alpine (Alpine specific) contain a blank password for a root user. System using the telegraf docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:17 Dec, 2020 | 00:58
Updated At:04 Aug, 2024 | 17:02
Rejected At:
▼CVE Numbering Authority (CNA)

The official telegraf docker images before 1.9.4-alpine (Alpine specific) contain a blank password for a root user. System using the telegraf docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/koharin/koharin2/blob/main/CVE-2020-35187
x_refsource_MISC
Hyperlink: https://github.com/koharin/koharin2/blob/main/CVE-2020-35187
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/koharin/koharin2/blob/main/CVE-2020-35187
x_refsource_MISC
x_transferred
Hyperlink: https://github.com/koharin/koharin2/blob/main/CVE-2020-35187
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:17 Dec, 2020 | 01:15
Updated At:17 Dec, 2020 | 16:26

The official telegraf docker images before 1.9.4-alpine (Alpine specific) contain a blank password for a root user. System using the telegraf docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.010.0HIGH
AV:N/AC:L/Au:N/C:C/I:C/A:C
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 10.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:C/I:C/A:C
CPE Matches

influxdata
influxdata
>>telegraf>>Versions from 0.13.0-alpine(inclusive) to 1.9.4-alpine(exclusive)
cpe:2.3:a:influxdata:telegraf:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-306Primarynvd@nist.gov
CWE ID: CWE-306
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/koharin/koharin2/blob/main/CVE-2020-35187cve@mitre.org
Third Party Advisory
Hyperlink: https://github.com/koharin/koharin2/blob/main/CVE-2020-35187
Source: cve@mitre.org
Resource:
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

437Records found

CVE-2025-26345
Matching Score-4
Assigner-Nozomi Networks Inc.
ShareView Details
Matching Score-4
Assigner-Nozomi Networks Inc.
CVSS Score-9.8||CRITICAL
EPSS-0.16% / 37.63%
||
7 Day CHG~0.00%
Published-12 Feb, 2025 | 13:27
Updated-18 Feb, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306 "Missing Authentication for Critical Function" in maxprofile/menu/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to edit user group permissions via crafted HTTP requests.

Action-Not Available
Vendor-Q-Free
Product-MaxTime
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-35854
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.96% / 87.91%
||
7 Day CHG~0.00%
Published-20 Jun, 2023 | 00:00
Updated-02 Aug, 2024 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Zoho ManageEngine ADSelfService Plus through 6113 has an authentication bypass that can be exploited to steal the domain controller session token for identity spoofing, thereby achieving the privileges of the domain controller administrator. NOTE: the vendor's perspective is that they have "found no evidence or detail of a security vulnerability."

Action-Not Available
Vendor-n/aZoho Corporation Pvt. Ltd.
Product-manageengine_adselfservice_plusn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-10625
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.25% / 47.91%
||
7 Day CHG~0.00%
Published-09 Apr, 2020 | 13:06
Updated-04 Aug, 2024 | 11:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

WebAccess/NMS (versions prior to 3.0.2) allows an unauthenticated remote user to create a new admin account.

Action-Not Available
Vendor-n/aAdvantech (Advantech Co., Ltd.)
Product-webaccess\/nmsWebAccess/NMS
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-10282
Matching Score-4
Assigner-Alias Robotics S.L.
ShareView Details
Matching Score-4
Assigner-Alias Robotics S.L.
CVSS Score-9.8||CRITICAL
EPSS-0.44% / 62.37%
||
7 Day CHG~0.00%
Published-03 Jul, 2020 | 14:30
Updated-16 Sep, 2024 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
RVD#3316: No authentication in MAVLink protocol

The Micro Air Vehicle Link (MAVLink) protocol presents no authentication mechanism on its version 1.0 (nor authorization) whichs leads to a variety of attacks including identity spoofing, unauthorized access, PITM attacks and more. According to literature, version 2.0 optionally allows for package signing which mitigates this flaw. Another source mentions that MAVLink 2.0 only provides a simple authentication system based on HMAC. This implies that the flying system overall should add the same symmetric key into all devices of network. If not the case, this may cause a security issue, that if one of the devices and its symmetric key are compromised, the whole authentication system is not reliable.

Action-Not Available
Vendor-dronecodeunspecified
Product-micro_air_vehicle_linkMAVLink
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-10038
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.39%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.

Action-Not Available
Vendor-Siemens AG
Product-sicam_t_firmwaresicam_mmusicam_sgu_firmwaresicam_mmu_firmwaresicam_sgusicam_tSICAM TSICAM MMUSICAM SGU
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-33553
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.04% / 10.69%
||
7 Day CHG~0.00%
Published-07 Jun, 2023 | 00:00
Updated-07 Jan, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue in Planet Technologies WDRT-1800AX v1.01-CP21 allows attackers to bypass authentication and escalate privileges to root via manipulation of the LoginStatus cookie.

Action-Not Available
Vendor-planetn/a
Product-wdrt-1800axwdrt-1800ax_firmwaren/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CWE ID-CWE-287
Improper Authentication
CVE-2023-34060
Matching Score-4
Assigner-VMware by Broadcom
ShareView Details
Matching Score-4
Assigner-VMware by Broadcom
CVSS Score-9.8||CRITICAL
EPSS-0.07% / 20.86%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 20:20
Updated-07 Jan, 2025 | 19:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VMware Cloud Director Appliance contains an authentication bypass vulnerability in case VMware Cloud Director Appliance was upgraded to 10.5 from an older version. On an upgraded version of VMware Cloud Director Appliance 10.5, a malicious actor with network access to the appliance can bypass login restrictions when authenticating on port 22 (ssh) or port 5480 (appliance management console) . This bypass is not present on port 443 (VCD provider and tenant login). On a new installation of VMware Cloud Director Appliance 10.5, the bypass is not present. VMware Cloud Director Appliance is impacted since it uses an affected version of sssd from the underlying Photon OS. The sssd issue is no longer present in versions of Photon OS that ship with sssd-2.8.1-11 or higher (Photon OS 3) or sssd-2.8.2-9 or higher (Photon OS 4 and 5).

Action-Not Available
Vendor-n/aVMware (Broadcom Inc.)
Product-photon_oscloud_directorVMware Cloud Director Appliance (VCD Appliance)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-9201
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.01% / 82.97%
||
7 Day CHG~0.00%
Published-26 Feb, 2019 | 23:00
Updated-16 Sep, 2024 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories.

Action-Not Available
Vendor-n/aPhoenix Contact GmbH & Co. KG
Product-ilc_151_eth\/xc_firmwareilc_171_eth_2tx_firmwareilc_171_eth_2txilc_151_eth\/xcilc_131_eth\/xc_firmwareilc_131_eth\/xcilc_191_me\/anilc_191_eth_2txilc_191_eth_2tx_firmwareaxc_1050ilc_191_me\/an_firmwareilc_131_eth_firmwareilc_131_ethilc_151_eth_firmwareaxc_1050_firmwareilc_151_ethn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-31411
Matching Score-4
Assigner-SICK AG
ShareView Details
Matching Score-4
Assigner-SICK AG
CVSS Score-9.8||CRITICAL
EPSS-0.17% / 37.98%
||
7 Day CHG~0.00%
Published-19 Jun, 2023 | 14:59
Updated-09 Dec, 2024 | 21:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote unprivileged attacker can modify and access configuration settings on the EventCam App due to the absence of API authentication. The lack of authentication in the API allows the attacker to potentially compromise the functionality of the EventCam App.

Action-Not Available
Vendor-SICK AG
Product-sick_eventcam_appEventCam App
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-5617
Matching Score-4
Assigner-Rapid7, Inc.
ShareView Details
Matching Score-4
Assigner-Rapid7, Inc.
CVSS Score-10||CRITICAL
EPSS-1.91% / 82.58%
||
7 Day CHG~0.00%
Published-06 Nov, 2019 | 18:30
Updated-17 Sep, 2024 | 02:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
C4G BLIS Improper Access Control

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.

Action-Not Available
Vendor-gatechComputing For Good
Product-computing_for_good\'s_basic_laboratory_information_systemBasic Laboratory Information System
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-31143
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-5.9||MEDIUM
EPSS-0.11% / 30.72%
||
7 Day CHG~0.00%
Published-09 May, 2023 | 14:59
Updated-28 Jan, 2025 | 16:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Mage terminal user authentication not working properly

mage-ai is an open-source data pipeline tool for transforming and integrating data. Those who use Mage starting in version 0.8.34 and prior to 0.8.72 with user authentication enabled may be affected by a vulnerability. The terminal could be accessed by users who are not signed in or do not have editor permissions. Version 0.8.72 contains a fix for this issue.

Action-Not Available
Vendor-magemage-ai
Product-mage-aimage-ai
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-6543
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-36.26% / 96.98%
||
7 Day CHG~0.00%
Published-13 Feb, 2019 | 01:00
Updated-16 Sep, 2024 | 18:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.

Action-Not Available
Vendor-ICS-CERTAVEVA
Product-indusoft_web_studiointouch_machine_edition_2014AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-5620
Matching Score-4
Assigner-Rapid7, Inc.
ShareView Details
Matching Score-4
Assigner-Rapid7, Inc.
CVSS Score-9.8||CRITICAL
EPSS-77.23% / 98.93%
||
7 Day CHG~0.00%
Published-29 Apr, 2020 | 22:15
Updated-17 Sep, 2024 | 03:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB MicroSCADA Pro SYS600 Missing Authentication for Critical Function

ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.

Action-Not Available
Vendor-Hitachi Energy Ltd.Microsoft CorporationABB
Product-microscada_pro_sys600windows_7windows_xpMicroSCADA Pro SYS600
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-29411
Matching Score-4
Assigner-Schneider Electric
ShareView Details
Matching Score-4
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-5.99% / 90.33%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:49
Updated-05 Feb, 2025 | 21:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-5504
Matching Score-4
Assigner-NetApp, Inc.
ShareView Details
Matching Score-4
Assigner-NetApp, Inc.
CVSS Score-9.8||CRITICAL
EPSS-1.24% / 78.45%
||
7 Day CHG~0.00%
Published-24 Sep, 2019 | 19:53
Updated-04 Aug, 2024 | 20:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

ONTAP Select Deploy administration utility versions 2.12 & 2.12.1 ship with an HTTP service bound to the network allowing unauthenticated remote attackers to perform administrative actions.

Action-Not Available
Vendor-n/aNetApp, Inc.
Product-ontap_select_deploy_administration_utilityONTAP Select Deploy administration utility
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-28697
Matching Score-4
Assigner-TWCERT/CC
ShareView Details
Matching Score-4
Assigner-TWCERT/CC
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.36%
||
7 Day CHG~0.00%
Published-27 Apr, 2023 | 00:00
Updated-31 Jan, 2025 | 18:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Moxa MiiNePort E1 - Broken Access Control

Moxa MiiNePort E1 has a vulnerability of insufficient access control. An unauthenticated remote user can exploit this vulnerability to perform arbitrary system operation or disrupt service.

Action-Not Available
Vendor-Moxa Inc.
Product-miineport_e1_firmwaremiineport_e1MiiNePort E1
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-27396
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-9.8||CRITICAL
EPSS-1.54% / 80.67%
||
7 Day CHG~0.00%
Published-19 Jun, 2023 | 00:00
Updated-24 Dec, 2024 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

FINS (Factory Interface Network Service) is a message communication protocol, which is designed to be used in closed FA (Factory Automation) networks, and is used in FA networks composed of OMRON products. Multiple OMRON products that implement FINS protocol contain following security issues -- (1)Plaintext communication, and (2)No authentication required. When FINS messages are intercepted, the contents may be retrieved. When arbitrary FINS messages are injected, any commands may be executed on, or the system information may be retrieved from, the affected device. Affected products and versions are as follows: SYSMAC CS-series CPU Units, all versions, SYSMAC CJ-series CPU Units, all versions, SYSMAC CP-series CPU Units, all versions, SYSMAC NJ-series CPU Units, all versions, SYSMAC NX1P-series CPU Units, all versions, SYSMAC NX102-series CPU Units, all versions, and SYSMAC NX7 Database Connection CPU Units (Ver.1.16 or later)

Action-Not Available
Vendor-omronOMRON Corporation
Product-nx1p2-1040dt_firmwarenx701-1620_firmwarenj501-5300cp1e-e10dt-d_firmwarecp1e-e40sdr-a_firmwarecj2h-cpu64_firmwarecp1e-n40s1dt-d_firmwarecp1w-20edt_firmwarecs1w-etn21cp2w-cifd2cp1w-ext01_firmwarecp2e-s30dt-d_firmwarecp1w-40edrcp2e-n30dt-dcp1l-el20dr-dcp1h-x40dr-acp2e-n20dt-d_firmwarecs1w-clk_firmwarenx102-1000cp1e-n20dt-acp2w-cifd3_firmwarecp1w-mad42_firmwarecp1h-xa40dr-a_firmwarecp1w-16ercp1l-l14dt-a_firmwarecp1l-m30dr-acp1l-l20dt-acp2w-cifd2_firmwarenx1p2-1140dt1cp1e-n60s1dr-a_firmwarecp1w-20edtcp1w-ts002cp2e-n60dr-acp1l-em40dt1-dcj2m-cpu32cp1e-n40sdt-dcp1e-n30sdr-acp1e-n14dt-acp2e-s60dt-d_firmwarecp2e-s40dt-d_firmwarecp1w-ts102cs1w-ncf71cp1e-n20dr-acp1l-m40dr-dcp2e-n40dr-d_firmwarecp2e-e14dr-a_firmwarecp1w-40edt_firmwarecp2e-e60dr-a_firmwarenj501-r400_firmwarecp1l-l20dt1-dnj501-1300_firmwarecp1l-l14dr-dcp1e-n30s1dr-a_firmwarecp1w-dam01cp1h-x40dt-d_firmwarecp1e-n40sdr-acj2m-cpu15_firmwarecp2e-s40dt1-dcp2e-n14dr-dcp1e-n20dr-dcp1w-cif11_firmwarecp2e-s30dr-a_firmwarecp1e-e14sdr-a_firmwarecj2m-cpu12_firmwarecp1e-n30dt-dnj501-r400cp1e-n30s1dt-d_firmwarecj2h-cpu67-eip_firmwarecp2e-n20dt-a_firmwarecp1w-srt21nj101-9020cs1w-clkcp1e-e20sdr-acj2h-cpu68-eipcp2e-n30dr-acp2e-s60dt1-d_firmwarenj501-r320cp1l-m30dt-d_firmwarecp2e-n30dt-a_firmwarecp1l-m30dt-a_firmwarecp2e-s30dt1-dcp1e-n60dr-d_firmwarecj2m-cpu33_firmwarecp1l-l20dr-a_firmwarecs1w-nc471nx1p2-1040dt1cp1w-ts001cp2e-n60dt1-d_firmwarecp1w-ad042cp2e-e40dr-a_firmwarecp1e-n60sdt-dcp1e-n14dt1-dcp2e-n14dr-d_firmwarecs1w-nc471_firmwarecp2e-n60dt-d_firmwarecp2e-e40dr-acp1w-8ercp1l-l14dr-d_firmwarenx102-1000_firmwarecp1e-n60s1dt1-d_firmwarecp2e-n14dt-acp1e-n60dt-a_firmwarecp2e-s60dr-acp1e-n20dt1-dnx102-1100_firmwarecp1w-20edr1_firmwarecp1w-ad041_firmwarecp1e-n60sdr-anj501-1320_firmwarecp2e-n20dt-acp1e-e10dt-dcp1e-n30dt1-a_firmwarecp1w-mab221_firmwarecp1e-e20dr-a_firmwarecs1w-spu01-v2_firmwarecp1e-n60dr-dcp1l-em40dt1-d_firmwarecp1l-l20dr-d_firmwarenj501-4400cp2e-e60dr-acp2e-n60dr-d_firmwarecp1e-n14dt1-a_firmwarecp1l-em40dr-d_firmwarecp1e-n40dt1-a_firmwarecp1w-cif01cp1e-n14dt-dcp2e-n40dt-dnj-pd3001_firmwarecs1w-nc271_firmwarenx1p2-1140dtcp1w-mad42cp2e-s30dt-dcj2m-cpu12cp1e-n40s1dt1-dnj501-4310cp1e-n20dt-dcp1l-m30dt1-d_firmwarecp1e-e14dr-a_firmwarecp1l-l10dt-dcp1e-n14dr-acs1w-drm21-v1_firmwarenj501-4300_firmwarecp1e-n14dt-a_firmwarecp1w-ad042_firmwarenj501-4500_firmwarecj2h-cpu64cp1w-srt21_firmwarecp1w-20edt1cp1e-n60dt1-d_firmwarecp1w-ts101_firmwarecp2e-n40dr-dcp1w-16er_firmwarecp2e-e20dr-acp1e-n20dt-a_firmwarenx102-1100cp1l-em30dt1-d_firmwarecp1e-na20dt1-dcp1e-n40dt1-dcp1l-em30dt1-dcp1l-m30dr-dnx1p2-1040dt1_firmwarecp1l-l10dt-d_firmwarecp1w-16et1_firmwarecp2w-cifd1cp1w-mad44_firmwarecj2m-md211cp1w-ts101cp1w-40edr_firmwarecp1e-n40sdt-d_firmwarenx701-1720_firmwarecp1l-m60dr-dcp1w-8et1_firmwarecp1w-me05m_firmwarecp1w-mad11_firmwarecp1e-n14dt1-d_firmwarecp1e-n60dt1-dcs1w-spu02-v2_firmwarecj2m-cpu34cp2e-n14dt-d_firmwarecp1w-8edcj2m-cpu31_firmwarecp1w-cif41cp1w-40edtcp1h-xa40dt-dcp1l-m60dt1-d_firmwarecp1e-n40sdt1-d_firmwarecp1l-l10dt1-dcp1l-m60dt1-dcp1e-e60sdr-a_firmwarecp2e-n30dr-a_firmwarecp1e-n40dr-a_firmwarecj2m-cpu11cp1w-32etcp1e-n40dt-acp1e-n14dr-a_firmwarecp1e-e10dt1-dcj2m-md212_firmwarecp1w-40edt1nj501-r500nj501-1320nj501-1340_firmwarenj301-1200_firmwarenx102-1020nx102-9000cp2e-n60dr-dcp2e-n20dr-dcp1w-ts003_firmwarecp2e-n14dt1-d_firmwarecp1h-xa40dt1-dcp1l-m60dr-d_firmwarecp2e-n14dt-dcs1w-drm21-v1cp2e-n20dr-anx102-1220cp1e-n40sdr-a_firmwarenx102-1200_firmwarecp1l-m40dt-dcp1w-16et_firmwarenx1p2-9024dt_firmwarecp2e-n40dt-d_firmwarecp1e-n40sdt1-dcp1e-n40s1dr-acp2e-s40dt-dcp1e-e40dr-acp1e-n30s1dt1-dcp1l-m30dt1-dnx1p2-1140dt1_firmwarenj501-1400_firmwarecp1w-mab221nj501-1500_firmwarecp2e-s40dr-a_firmwarecs1w-eip21_firmwarecp1l-m30dt-dcp1e-e10dt-anj501-1420cp1w-32er_firmwarenx701-1720nj501-4320cp1w-cif12-v1cp1l-m60dr-a_firmwarecp1h-x40dt1-d_firmwarecp1w-8et_firmwarenx102-9000_firmwarenj501-1520nx102-1120_firmwarecp2e-e30dr-a_firmwarecp1l-m30dr-a_firmwarecp2e-n40dt1-d_firmwarecp1e-n60dt1-a_firmwarenj501-4300cp1l-m30dt-anj101-1000_firmwarecj2m-cpu13_firmwarenj101-9020_firmwarecs1w-fln22_firmwarecp1h-x40dt-dcp1e-e60sdr-acp1w-da042cp1e-n30dr-d_firmwarecp1e-n30sdt1-dcp1l-el20dr-d_firmwarecp1e-n40s1dt-dcp2e-n60dr-a_firmwarenx1p2-9024dt1cp1e-n30sdt-d_firmwarecp1e-e40sdr-acp1w-mad11cp2e-n20dr-d_firmwarecp1e-n30s1dt1-d_firmwarecp1e-n20dt-d_firmwarecp1e-n60s1dt-d_firmwarecp1l-m40dr-acp1e-n40s1dt1-d_firmwarecj2h-cpu67-eipcp1l-l20dr-dcp1l-l14dr-anj501-r300cp1l-el20dt-dcp1e-n40dr-dcs1w-nc271cp2e-n60dt-acj2h-cpu66-eipcp1e-n30s1dr-acp1e-n60sdt-d_firmwarenx1p2-9024dtnj501-1420_firmwarecp1l-l20dt1-d_firmwarecp1l-m40dt1-dcj2m-cpu14_firmwarecp1l-m60dt-dcp1l-em30dt-d_firmwarecp1l-l10dr-a_firmwarecj2h-cpu66_firmwarecp1e-e30sdr-acp1e-n30sdr-a_firmwarecp1e-n20dt1-acp1e-n20dr-a_firmwarecp1w-me05mcp1e-n30dt-d_firmwarenx1p2-1140dt_firmwarenx1p2-1040dtnx102-1020_firmwarenj501-4310_firmwarecj2m-cpu13cs1w-spu01-v2cp1w-ts102_firmwarecp1w-cn811cp1h-xa40dt1-d_firmwarecp1w-16etnj501-r520cp1e-n30dt1-d_firmwarecp2e-n14dt-a_firmwarecp1h-x40dt1-dnj501-4320_firmwarecs1w-spu02-v2nj501-4400_firmwarecp1w-da042_firmwarecj2m-cpu11_firmwarecp1l-m60dt-a_firmwarecp1e-n40dt-dnx102-9020cp1l-l10dr-acp1l-m40dr-d_firmwarecp1w-ts004cp1h-y20dt-dcp2e-s30dt1-d_firmwarenx102-1200cp1e-n40dr-acp1w-dam01_firmwarecp2e-n20dr-a_firmwarecp1l-el20dt1-d_firmwarenx1p2-9024dt1_firmwarenj101-9000_firmwarecp2w-cifd3cp2e-s60dr-a_firmwarecp1w-40edt1_firmwarecp1l-em40dt-d_firmwarecp1w-20edt1_firmwarecp1e-n14dr-d_firmwarecp1e-n20dt1-d_firmwarecp1e-n30s1dt-dnj501-5300_firmwarecp2e-n14dt1-dcp1e-n40dt-d_firmwarenj101-1020cp2e-s40dr-acj2m-cpu33cp1h-xa40dt-d_firmwarecj2h-cpu65-eipcp2e-n40dt-acp1e-n30dt1-dcp1l-m40dr-a_firmwarecs1w-ncf71_firmwarecp1e-e10dt-a_firmwarecp1e-e14dr-acp2e-e30dr-acp1l-l14dt-dcp1e-e10dt1-a_firmwarecp1e-n30dr-anj501-1340cj2m-cpu32_firmwarecp1e-n20dr-d_firmwarecp1l-l10dt-a_firmwarecj2h-cpu66-eip_firmwarecp1w-cif12-v1_firmwarecj2h-cpu64-eipcp1e-e30dr-a_firmwarecp1l-l10dt1-d_firmwarecp2e-e20dr-a_firmwarecp1l-l14dr-a_firmwarecp1w-adb21cj2m-cpu35_firmwarecp1w-8etcp1l-em30dr-d_firmwarecp1e-e10dr-dcp1e-n60dr-acp1w-ad041cp1e-n40dt-a_firmwarecp2e-n30dt-acp1l-l20dt-d_firmwarecp1h-x40dr-a_firmwarecp2e-n40dt1-dcp1w-da021_firmwarecp2e-n30dt1-dcj2m-cpu31cp2e-n40dr-a_firmwarecp1e-n40dr-d_firmwarecp1e-na20dt1-d_firmwarecp1w-20edr1cp1e-n30sdt-dcp2e-s40dt1-d_firmwarecp1l-l14dt1-dcj2h-cpu65_firmwarecj2h-cpu68cp1e-e10dt1-d_firmwarenj501-r300_firmwarecj2h-cpu68_firmwarecp1l-l10dt-acp1w-ext01nj501-r320_firmwarecp1e-na20dt-d_firmwarecj2m-cpu15cp1w-adb21_firmwarecp1w-16et1cp1l-em30dt-dcp1e-n14dt-d_firmwarecp1e-n30dr-a_firmwarecp1e-e10dt1-anj501-1300cp1w-mad44cp1w-cif41_firmwarenx102-1120cs1w-etn21_firmwarecp1e-e10dr-d_firmwarecp1w-da041_firmwarecp1h-xa40dr-anj-pa3001_firmwarenx102-9020_firmwarecp1e-n30dt-anj101-1000cp2e-n20dt1-dcp1l-l14dt-anj-pd3001cp2e-n14dr-acp2e-n30dt1-d_firmwarecp1e-na20dr-acp1w-dab21vcp1e-n60dt1-acj2m-cpu35cp1e-e10dr-acp1l-l14dt1-d_firmwarecj2h-cpu68-eip_firmwarecj2h-cpu67cp2e-n60dt-a_firmwarecp1l-em30dr-dcj2m-md212nj501-1500cp1l-l10dr-dcp2e-s60dt1-dcp1e-e20sdr-a_firmwarenj501-1400cp1w-dab21v_firmwarecp1l-em40dt-dcj2h-cpu64-eip_firmwarecp2e-n14dr-a_firmwarecp1w-ts002_firmwarecp1w-32ercp1e-e30sdr-a_firmwarecp1e-n60s1dt1-dcp1e-n14dt1-acp1e-n60dt-d_firmwarecp1e-e40dr-a_firmwarecp1l-l14dt-d_firmwarecp2e-n60dt-dcp1e-e20dr-anj-pa3001cp1w-8ed_firmwarenx102-1220_firmwarecp2e-e14dr-acp1l-m60dr-acp1l-m40dt1-d_firmwarenj301-1100cp1h-y20dt-d_firmwarecp1l-el20dt-d_firmwarecp1w-ts004_firmwarenj101-9000cp2e-n40dt-a_firmwarecp1l-m60dt-acj2h-cpu65-eip_firmwarecp2e-n40dr-acp1e-e30dr-acp1e-n30dt1-anj501-r520_firmwarecp1l-m40dt-a_firmwarecp2e-n30dr-dcp1w-32et_firmwarecp1e-n14dr-dcp1e-n60s1dt-dcp1w-8er_firmwarecp1e-n30sdt1-d_firmwarenj101-1020_firmwarecp1w-8et1cp1e-n60sdt1-d_firmwarecp2e-n30dt-d_firmwarecj2h-cpu67_firmwarecp2e-n60dt1-dcp1e-n30dt-a_firmwarecp1e-na20dr-a_firmwarecp2e-n20dt-dcp1l-m40dt-d_firmwarecp1l-l20dt-dnj501-r420_firmwarenj501-r420cj2h-cpu66nj501-4500cp1e-n60sdr-a_firmwarecp1e-n60sdt1-dcp1l-l20dt-a_firmwarecp1e-n40dt1-d_firmwarecj2h-cpu65cp1e-na20dt-dcp1w-cif11cp1e-n60dr-a_firmwarecp1e-n40s1dr-a_firmwarecp1l-l20dr-acs1w-eip21nj501-r500_firmwarecp1e-n60dt-acp1e-n60s1dr-acp2e-n20dt1-d_firmwarecp2e-s30dr-acp1w-da041cs1w-fln22cp2e-n30dr-d_firmwarecp1e-n30dr-dcp2e-s60dt-dcp1w-cn811_firmwarenj301-1100_firmwarecp1e-e14sdr-acp1l-em40dr-dcp2w-cifd1_firmwarecp1l-el20dt1-dcp1w-cif01_firmwarecj2m-cpu14cj2m-md211_firmwarecp1w-32et1_firmwarecj2m-cpu34_firmwarecp1e-n40dt1-acp1l-l10dr-d_firmwarecp1l-m30dr-d_firmwarecp1w-ts001_firmwarecp1w-32et1nj301-1200cp1w-da021cp1e-n20dt1-a_firmwarenj501-1520_firmwarecp1l-m40dt-acp1e-n60dt-dnx701-1620cp1w-ts003cp1l-m60dt-d_firmwarecp1e-e10dr-a_firmwareMultiple OMRON products which implement FINS protocol
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-19104
Matching Score-4
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Matching Score-4
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-9.1||CRITICAL
EPSS-0.24% / 47.25%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 14:31
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Improper Authentication and Access Control

The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.

Action-Not Available
Vendor-Busch-Jaeger (ABB)ABB
Product-6186\/11_firmware6186\/11tg\/s3.2tg\/s3.2_firmware6186/11 Telefon-Gateway TG/S 3.2 Telephone Gateway
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18666
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.52% / 87.19%
||
7 Day CHG~0.00%
Published-15 May, 2020 | 17:18
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DAP-1360 revision F devices. Remote attackers can start a telnet service without authorization via an undocumented HTTP request. Although this is the primary vulnerability, the impact depends on the firmware version. Versions 609EU through 613EUbeta were tested. Versions through 6.12b01 have weak root credentials, allowing an attacker to gain remote root access. After 6.12b01, the root credentials were changed but the telnet service can still be started without authorization.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dap-1360_revision_f_firmwaredap-1360_revision_fn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-1895
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-9.8||CRITICAL
EPSS-2.38% / 84.39%
||
7 Day CHG~0.00%
Published-07 Aug, 2019 | 20:55
Updated-19 Nov, 2024 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability

A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-enterprise_network_function_virtualization_infrastructureCisco Enterprise NFV Infrastructure Software
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18938
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-30.11% / 96.51%
||
7 Day CHG~0.00%
Published-14 Nov, 2019 | 18:52
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.

Action-Not Available
Vendor-hm_email_projecteq-3n/a
Product-homematic_ccu2_firmwarehm_emailhomematic_ccu3_firmwarehomematic_ccu3homematic_ccu2n/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18465
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.02% / 3.27%
||
7 Day CHG~0.00%
Published-31 Oct, 2019 | 16:11
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Progress MOVEit Transfer 11.1 before 11.1.3, a vulnerability has been found that could allow an attacker to sign in without full credentials via the SSH (SFTP) interface. The vulnerability affects only certain SSH (SFTP) configurations, and is applicable only if the MySQL database is being used.

Action-Not Available
Vendor-n/aIpswitch, Inc.
Product-moveit_transfern/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18284
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.24%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-17506
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-92.73% / 99.74%
||
7 Day CHG-0.18%
Published-11 Oct, 2019 | 19:29
Updated-05 Aug, 2024 | 01:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-817lw_a1_firmwaredir-868l_b1dir-868l_b1_firmwaredir-817lw_a1n/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18572
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-8.3||HIGH
EPSS-1.31% / 79.02%
||
7 Day CHG~0.00%
Published-18 Dec, 2019 | 20:50
Updated-16 Sep, 2024 | 22:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The RSA Identity Governance and Lifecycle and RSA Via Lifecycle and Governance products prior to 7.1.1 P03 contain an Improper Authentication vulnerability. A Java JMX agent running on the remote host is configured with plain text password authentication. An unauthenticated remote attacker can connect to the JMX agent and monitor and manage the Java application.

Action-Not Available
Vendor-Dell Inc.
Product-rsa_identity_governance_and_lifecycleRSA Identity Governance & Lifecycle
CWE ID-CWE-306
Missing Authentication for Critical Function
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2019-18939
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-37.14% / 97.04%
||
7 Day CHG~0.00%
Published-14 Nov, 2019 | 18:53
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the HM-Print AddOn through 1.2a installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi and exec1.cgi scripts, which execute TCL script content from an HTTP POST request.

Action-Not Available
Vendor-eq-3hm-print_projectn/a
Product-homematic_ccu2_firmwarehm-printhomematic_ccu3_firmwarehomematic_ccu3homematic_ccu2n/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18925
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.34% / 55.83%
||
7 Day CHG~0.00%
Published-12 Nov, 2019 | 16:15
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Systematic IRIS WebForms 5.4 and its functionalities can be accessed and used without any form of authentication.

Action-Not Available
Vendor-systematicn/a
Product-iris_webformsn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-16199
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-45.81% / 97.53%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 20:53
Updated-05 Aug, 2024 | 01:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

eQ-3 Homematic CCU2 before 2.47.18 and CCU3 before 3.47.18 allow Remote Code Execution by unauthenticated attackers with access to the web interface via an HTTP POST request to certain URLs related to the ReGa core process.

Action-Not Available
Vendor-eq-3n/a
Product-homematic_ccu2_firmwarehomematic_ccu3_firmwarehomematic_ccu3homematic_ccu2n/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-16879
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.18% / 39.65%
||
7 Day CHG~0.00%
Published-14 Apr, 2020 | 16:39
Updated-05 Aug, 2024 | 01:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.

Action-Not Available
Vendor-mysyngeryssn/a
Product-husky_rtu_6049-e70_firmwarehusky_rtu_6049-e70n/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2024-7503
Matching Score-4
Assigner-Wordfence
ShareView Details
Matching Score-4
Assigner-Wordfence
CVSS Score-9.8||CRITICAL
EPSS-3.44% / 87.03%
||
7 Day CHG~0.00%
Published-10 Aug, 2024 | 02:01
Updated-07 Feb, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WooCommerce - Social Login <= 2.7.5 - Authentication Bypass to Account Takeover

The WooCommerce - Social Login plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 2.7.5. This is due to the use of loose comparison of the activation code in the 'woo_slg_confirm_email_user' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the userID. This requires the email module to be enabled.

Action-Not Available
Vendor-WPWeb Elite
Product-woocommerce_social_loginWooCommerce - Social Loginwoocommerce_social_login
CWE ID-CWE-288
Authentication Bypass Using an Alternate Path or Channel
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-17146
Matching Score-4
Assigner-Zero Day Initiative
ShareView Details
Matching Score-4
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-17.71% / 94.86%
||
7 Day CHG~0.00%
Published-07 Jan, 2020 | 23:05
Updated-05 Aug, 2024 | 01:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link DCS-960L v1.07.102. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HNAP service, which listens on TCP port 80 by default. When parsing the SOAPAction request header, the process does not properly validate the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the admin user. Was ZDI-CAN-8458.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-935l_firmwaredcs-960l_firmwaredcs-960ldcs-935lDCS-960L
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-35865
Matching Score-4
Assigner-Zero Day Initiative
ShareView Details
Matching Score-4
Assigner-Zero Day Initiative
CVSS Score-7.3||HIGH
EPSS-18.09% / 94.92%
||
7 Day CHG~0.00%
Published-03 Aug, 2022 | 15:21
Updated-03 Aug, 2024 | 09:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows remote attackers to execute arbitrary code on affected installations of BMC Track-It! 20.21.2.109. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authorization of HTTP requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of the service account. Was ZDI-CAN-16709.

Action-Not Available
Vendor-bmcBMC
Product-track-it\!Track-It!
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-15932
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.44% / 62.45%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 13:39
Updated-05 Aug, 2024 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Intesync Solismed 3.3sp has Incorrect Access Control.

Action-Not Available
Vendor-intesyncn/a
Product-solismedn/a
CWE ID-CWE-862
Missing Authorization
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-15068
Matching Score-4
Assigner-TWCERT/CC
ShareView Details
Matching Score-4
Assigner-TWCERT/CC
CVSS Score-9.8||CRITICAL
EPSS-0.30% / 53.22%
||
7 Day CHG~0.00%
Published-25 Sep, 2019 | 18:10
Updated-16 Sep, 2024 | 21:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
A broken access control vulnerability discovered in Smart Battery A4

A broken access control vulnerability in Smart Battery A4, a multifunctional portable charger, firmware version ?<= r1.7.9 allows an attacker to get/reset administrator’s password without any authentication.

Action-Not Available
Vendor-gigastoneGigastone
Product-smart_battery_a4_firmwaresmart_battery_a4Smart Battery A4
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2010-5326
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-10||CRITICAL
EPSS-26.42% / 96.12%
||
7 Day CHG~0.00%
Published-13 May, 2016 | 10:00
Updated-30 Jul, 2025 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-05-03||Apply updates per vendor instructions.

The Invoker Servlet on SAP NetWeaver Application Server Java platforms, possibly before 7.3, does not require authentication, which allows remote attackers to execute arbitrary code via an HTTP or HTTPS request, as exploited in the wild in 2013 through 2016, aka a "Detour" attack.

Action-Not Available
Vendor-n/aSAP SE
Product-netweaver_application_server_javan/aNetWeaver
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-34767
Matching Score-4
Assigner-Israel National Cyber Directorate (INCD)
ShareView Details
Matching Score-4
Assigner-Israel National Cyber Directorate (INCD)
CVSS Score-5.9||MEDIUM
EPSS-0.20% / 42.57%
||
7 Day CHG~0.00%
Published-21 Jul, 2022 | 15:37
Updated-03 Aug, 2024 | 09:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ALLNET Gmbh - ADSL/VDSL Router inkl. Modem and Wlan Authorization Bypass

Web page which "wizardpwd.asp" ALLNET Router model WR0500AC is prone to Authorization bypass vulnerability – the password, located at "admin" allows changing the http[s]://wizardpwd.asp/cgi-bin. Does not validate the user's identity and can be accessed publicly.

Action-Not Available
Vendor-ALLNET GmbhALLNET GmbH
Product-all-wr0500acall-wr0500ac_firmwareALLNET Gmbh - ADSL/VDSL Router inkl. Modem and Wlan
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-12503
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.34% / 56.22%
||
7 Day CHG~0.00%
Published-02 Dec, 2019 | 16:57
Updated-04 Aug, 2024 | 23:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Due to unencrypted and unauthenticated data communication, the wireless barcode scanner Inateck BCST-60 is prone to keystroke injection attacks. Thus, an attacker is able to send arbitrary keystrokes to a victim's computer system, e.g., to install malware when the target system is unattended. In this way, an attacker can remotely take control over the victim's computer that is operated with an affected receiver of this device.

Action-Not Available
Vendor-inateckn/a
Product-bcst-60bcst-60_firmwaren/a
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-13405
Matching Score-4
Assigner-TWCERT/CC
ShareView Details
Matching Score-4
Assigner-TWCERT/CC
CVSS Score-9.8||CRITICAL
EPSS-0.52% / 65.90%
||
7 Day CHG~0.00%
Published-29 Aug, 2019 | 00:19
Updated-16 Sep, 2024 | 22:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Advan VD-1 allows a remote user to enable Android Debug Bridge without any authentication

A broken access control vulnerability found in Advan VD-1 firmware version 230 leads to insecure ADB service. An attacker can send a POST request to cgibin/AdbSetting.cgi to enable ADB without any authentication then take the compromised device as a relay or to install mining software.

Action-Not Available
Vendor-androvideoAndroVideo
Product-vd_1_firmwarevd_1Advan VD-1 firmware
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-12524
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.86% / 74.15%
||
7 Day CHG~0.00%
Published-15 Apr, 2020 | 18:35
Updated-04 Aug, 2024 | 23:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Squid through 4.7. When handling requests from users, Squid checks its rules to see if the request should be denied. Squid by default comes with rules to block access to the Cache Manager, which serves detailed server information meant for the maintainer. This rule is implemented via url_regex. The handler for url_regex rules URL decodes an incoming request. This allows an attacker to encode their URL to bypass the url_regex check, and gain access to the blocked resource.

Action-Not Available
Vendor-n/aSquid CacheCanonical Ltd.Debian GNU/Linux
Product-ubuntu_linuxdebian_linuxsquidn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-12125
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.34% / 55.83%
||
7 Day CHG~0.00%
Published-19 Mar, 2020 | 17:30
Updated-04 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In ONAP Logging through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.

Action-Not Available
Vendor-onapn/a
Product-open_network_automation_platformn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-12129
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.43% / 61.56%
||
7 Day CHG~0.00%
Published-19 Mar, 2020 | 13:43
Updated-04 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In ONAP MSB through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.

Action-Not Available
Vendor-onapn/a
Product-open_network_automation_platformn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2024-9289
Matching Score-4
Assigner-Wordfence
ShareView Details
Matching Score-4
Assigner-Wordfence
CVSS Score-9.8||CRITICAL
EPSS-1.41% / 79.76%
||
7 Day CHG~0.00%
Published-01 Oct, 2024 | 08:30
Updated-07 Oct, 2024 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WordPress & WooCommerce Affiliate Program <= 8.4.1 - Authentication Bypass to Account Takeover and Privilege Escalation

The WordPress & WooCommerce Affiliate Program plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 8.4.1. This is due to the rtwwwap_login_request_callback() function not properly validating a user's identity prior to authenticating them to the site. This makes it possible for unauthenticated attackers to log in as any user, including administrators, granted they have access to the administrator's email.

Action-Not Available
Vendor-redefiningthewebRedefiningTheWebredefiningtheweb
Product-affiliate_proWordPress & WooCommerce Affiliate Programaffiliate_pro
CWE ID-CWE-288
Authentication Bypass Using an Alternate Path or Channel
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-12127
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.34% / 55.83%
||
7 Day CHG~0.00%
Published-19 Mar, 2020 | 17:30
Updated-04 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In ONAP OOM through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.

Action-Not Available
Vendor-onapn/a
Product-open_network_automation_platformn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-12128
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.43% / 61.56%
||
7 Day CHG~0.00%
Published-19 Mar, 2020 | 13:42
Updated-04 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In ONAP SO through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.

Action-Not Available
Vendor-onapn/a
Product-open_network_automation_platformn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-12288
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.34% / 55.83%
||
7 Day CHG~0.00%
Published-23 May, 2019 | 17:49
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in upgrade_htmls.cgi on VStarcam 100T (C7824WIP) KR75.8.53.20 and 200V (C38S) KR203.18.1.20 devices. The web service, network, and account files can be manipulated through a web UI firmware update without any authentication. The attacker can achieve access to the device through a manipulated web UI firmware update.

Action-Not Available
Vendor-vstracmvstarcamn/a
Product-c38s_firmwarec7824iwp_firmwarec38sc7824iwpn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-12130
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.43% / 61.56%
||
7 Day CHG~0.00%
Published-19 Mar, 2020 | 13:44
Updated-04 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In ONAP CLI through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.

Action-Not Available
Vendor-onapn/a
Product-open_network_automation_platformn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-12115
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.15% / 77.61%
||
7 Day CHG~0.00%
Published-18 Mar, 2020 | 17:05
Updated-04 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in ONAP SDC through Dublin. By accessing port 4000 of demo-sdc-sdc-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.

Action-Not Available
Vendor-onapn/a
Product-open_network_automation_platformn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-10922
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.49% / 80.33%
||
7 Day CHG~0.00%
Published-14 May, 2019 | 19:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7SIMATIC WinCC V7.3 and newerSIMATIC PCS 7 V8.0 and earlierSIMATIC PCS 7 V8.1 and newerSIMATIC WinCC V7.2 and earlier
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-2231
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-9.8||CRITICAL
EPSS-0.20% / 41.85%
||
7 Day CHG~0.00%
Published-21 Apr, 2023 | 14:31
Updated-02 Aug, 2024 | 06:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
MAXTECH MAX-G866ac Remote Management missing authentication

A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-max-techMAXTECH
Product-max-g866ac_firmwaremax-g866acMAX-G866ac
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-35587
Matching Score-4
Assigner-Oracle
ShareView Details
Matching Score-4
Assigner-Oracle
CVSS Score-9.8||CRITICAL
EPSS-94.26% / 99.92%
||
7 Day CHG~0.00%
Published-19 Jan, 2022 | 11:21
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-12-19||Apply updates per vendor instructions.

Vulnerability in the Oracle Access Manager product of Oracle Fusion Middleware (component: OpenSSO Agent). Supported versions that are affected are 11.1.2.3.0, 12.2.1.3.0 and 12.2.1.4.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Access Manager. Successful attacks of this vulnerability can result in takeover of Oracle Access Manager. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

Action-Not Available
Vendor-Oracle Corporation
Product-access_managerAccess ManagerFusion Middleware
CWE ID-CWE-306
Missing Authentication for Critical Function
  • Previous
  • 1
  • 2
  • ...
  • 7
  • 8
  • 9
  • Next
Details not found