The Micro Air Vehicle Link (MAVLink) protocol presents no authentication mechanism on its version 1.0 (nor authorization) whichs leads to a variety of attacks including identity spoofing, unauthorized access, PITM attacks and more. According to literature, version 2.0 optionally allows for package signing which mitigates this flaw. Another source mentions that MAVLink 2.0 only provides a simple authentication system based on HMAC. This implies that the flying system overall should add the same symmetric key into all devices of network. If not the case, this may cause a security issue, that if one of the devices and its symmetric key are compromised, the whole authentication system is not reliable.
Vulnerability in the Oracle Scripting product of Oracle E-Business Suite (component: iSurvey Module). Supported versions that are affected are 12.2.3-12.2.14. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Scripting. Successful attacks of this vulnerability can result in takeover of Oracle Scripting. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort of authentication. This allows attackers with access to the internal wireless and wired networks to take control of the robot seamlessly. In combination with CVE-2020-10269 and CVE-2020-10271, this flaw allows malicious actors to command the robot at desire.
The SolarWinds Orion API is vulnerable to an authentication bypass that could allow a remote attacker to execute API commands. This vulnerability could allow a remote attacker to bypass authentication and execute API commands which may result in a compromise of the SolarWinds instance. SolarWinds Orion Platform versions 2019.4 HF 5, 2020.2 with no hotfix installed, and 2020.2 HF 1 are affected.
Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories.
A first-factor authentication bypass vulnerability exists in the PingFederate with PingID Radius PCV when a MSCHAP authentication request is sent via a maliciously crafted RADIUS client request.
Authentication bypass when an OAuth2 Client is using client_secret_jwt as its authentication method on affected 11.3 versions via specially crafted requests.
Jector Smart TV FM-K75 devices allow remote code execution because there is an adb open port with root permission.
A vulnerability classified as critical was found in SourceCodester Book Store Management System 1.0. This vulnerability affects unknown code of the file /bsms_ci/index.php. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-214588.
The administrative web server component of TIBCO Software Inc.'s TIBCO ActiveMatrix BPM, TIBCO ActiveMatrix BPM Distribution for TIBCO Silver Fabric, TIBCO ActiveMatrix Policy Director, TIBCO ActiveMatrix Service Bus, TIBCO ActiveMatrix Service Grid, TIBCO ActiveMatrix Service Grid Distribution for TIBCO Silver Fabric, TIBCO Silver Fabric Enabler for ActiveMatrix BPM, and TIBCO Silver Fabric Enabler for ActiveMatrix Service Grid contains a vulnerability that could theoretically allow an unauthenticated user to download a file with credentials information. Affected releases are TIBCO Software Inc.'s TIBCO ActiveMatrix BPM: versions up to and including 4.2.0, TIBCO ActiveMatrix BPM Distribution for TIBCO Silver Fabric: versions up to and including 4.2.0, TIBCO ActiveMatrix Policy Director: versions up to and including 1.1.0, TIBCO ActiveMatrix Service Bus: versions up to and including 3.3.0, TIBCO ActiveMatrix Service Grid: versions up to and including 3.3.1, TIBCO ActiveMatrix Service Grid Distribution for TIBCO Silver Fabric: versions up to and including 3.3.0, TIBCO Silver Fabric Enabler for ActiveMatrix BPM: versions up to and including 1.4.1, and TIBCO Silver Fabric Enabler for ActiveMatrix Service Grid: versions up to and including 1.3.1.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.933 Application 20.0.2368 allows Unauthenticated Driver Package Editing V-2024-008.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
Improper Authentication, Missing Authentication for Critical Function, Improper Authorization vulnerability in Profelis Informatics and Consulting PassBox allows Authentication Abuse.This issue affects PassBox: before v1.2.
Array Networks Array AG Series and vxAG (9.4.0.481 and earlier) allow remote code execution. An attacker can browse the filesystem on the SSL VPN gateway using a flags attribute in an HTTP header without authentication. The product could then be exploited through a vulnerable URL. The 2023-03-09 vendor advisory stated "a new Array AG release with the fix will be available soon."
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
ONTAP Select Deploy administration utility versions 2.12 & 2.12.1 ship with an HTTP service bound to the network allowing unauthenticated remote attackers to perform administrative actions.
ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.913 Application 20.0.2253 allows Addition of Partial Admin Users Without Authentication V-2024-002.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/menu/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to edit user permissions via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/guest-mode/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to enable passwordless guest mode via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/accounts/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to reset arbitrary user passwords via crafted HTTP requests.
Kapsch TrafficCom RIS-9260 RSU LEO v3.2.0.829.23, v3.8.0.1119.42, and v4.6.0.1211.28 were discovered to contain Android Debug Bridge (ADB) pre-installed (/mnt/c3platpersistent/opt/platform-tools/adb) and enabled by default, allowing unauthenticated root shell access to the cellular modem via the default 'kapsch' user.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/menu/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to edit user group permissions via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/accounts/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to create arbitrary users, including administrators, via crafted HTTP requests.
It was found that default configuration of Heketi does not require any authentication potentially exposing the management interface to misuse. This isue only affects heketi as shipped with Openshift Container Platform 3.11.
A broken access control vulnerability found in Advan VD-1 firmware version 230 leads to insecure ADB service. An attacker can send a POST request to cgibin/AdbSetting.cgi to enable ADB without any authentication then take the compromised device as a relay or to install mining software.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/accounts/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to reset user PINs via crafted HTTP requests.
Windows Mobile Device Management Elevation of Privilege Vulnerability
CasaOS is an open-source Personal Cloud system. Due to a lack of IP address verification an unauthenticated attackers can execute arbitrary commands as `root` on CasaOS instances. The problem was addressed by improving the detection of client IP addresses in `391dd7f`. This patch is part of CasaOS 0.4.4. Users should upgrade to CasaOS 0.4.4. If they can't, they should temporarily restrict access to CasaOS to untrusted users, for instance by not exposing it publicly.
SAP PowerDesigner - version 16.7, has improper access control which might allow an unauthenticated attacker to run arbitrary queries against the back-end database via Proxy.
A missing authentication for critical function in FortiManager 7.6.0, FortiManager 7.4.0 through 7.4.4, FortiManager 7.2.0 through 7.2.7, FortiManager 7.0.0 through 7.0.12, FortiManager 6.4.0 through 6.4.14, FortiManager 6.2.0 through 6.2.12, Fortinet FortiManager Cloud 7.4.1 through 7.4.4, FortiManager Cloud 7.2.1 through 7.2.7, FortiManager Cloud 7.0.1 through 7.0.12, FortiManager Cloud 6.4.1 through 6.4.7 allows attacker to execute arbitrary code or commands via specially crafted requests.
Certain functionality within GMOD Apollo does not require authentication when passed with an administrative username
STW (aka Sensor-Technik Wiedemann) TCG-4 Connectivity Module DeploymentPackage_v3.03r0-Impala and DeploymentPackage_v3.04r2-Jellyfish and TCG-4lite Connectivity Module DeploymentPackage_v3.04r2-Jellyfish allow an attacker to gain full remote access with root privileges without the need for authentication, giving an attacker arbitrary remote code execution over LTE / 4G network via SMS.
Zoho ManageEngine ADSelfService Plus through 6113 has an authentication bypass that can be exploited to steal the domain controller session token for identity spoofing, thereby achieving the privileges of the domain controller administrator. NOTE: the vendor's perspective is that they have "found no evidence or detail of a security vulnerability."
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
Systematic IRIS WebForms 5.4 and its functionalities can be accessed and used without any form of authentication.
The RSA Identity Governance and Lifecycle and RSA Via Lifecycle and Governance products prior to 7.1.1 P03 contain an Improper Authentication vulnerability. A Java JMX agent running on the remote host is configured with plain text password authentication. An unauthenticated remote attacker can connect to the JMX agent and monitor and manage the Java application.
Missing Authentication for a Critical Function within the Kratos NGC Indoor Unit (IDU) before 11.4 allows remote attackers to obtain arbitrary control of the IDU/ODU system. Any attacker with layer-3 network access to the IDU can impersonate the Touch Panel Unit (TPU) within the IDU by sending crafted TCP requests to the IDU.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the Script Parser AddOn through 1.8 installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi script, which executes TCL script content from an HTTP POST request.
An issue was discovered on D-Link DAP-1360 revision F devices. Remote attackers can start a telnet service without authorization via an undocumented HTTP request. Although this is the primary vulnerability, the impact depends on the firmware version. Versions 609EU through 613EUbeta were tested. Versions through 6.12b01 have weak root credentials, allowing an attacker to gain remote root access. After 6.12b01, the root credentials were changed but the telnet service can still be started without authorization.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the HM-Print AddOn through 1.2a installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi and exec1.cgi scripts, which execute TCL script content from an HTTP POST request.
The administrative web interface of mySCADA myPRO Manager can be accessed without authentication which could allow an unauthorized attacker to retrieve sensitive information and upload files without the associated password.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link DCS-960L v1.07.102. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HNAP service, which listens on TCP port 80 by default. When parsing the SOAPAction request header, the process does not properly validate the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the admin user. Was ZDI-CAN-8458.
In Progress MOVEit Transfer 11.1 before 11.1.3, a vulnerability has been found that could allow an attacker to sign in without full credentials via the SSH (SFTP) interface. The vulnerability affects only certain SSH (SFTP) configurations, and is applicable only if the MySQL database is being used.
Victure PC530 devices allow unauthenticated TELNET access as root.