Vulnerability Details :

CVE-2020-7480

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-23 Mar, 2020 | 19:24
Updated At-04 Aug, 2024 | 09:33
Rejected At-
Credits

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:23 Mar, 2020 | 19:24
Updated At:04 Aug, 2024 | 09:33
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data.

Affected Products
Vendor
n/a
Product
Andover Continuum (All versions)
Versions
Affected
  • Andover Continuum (All versions)
Problem Types
TypeCWE IDDescription
CWECWE-94CWE-94: Improper Control of Generation of Code ('Code Injection')
Type: CWE
CWE ID: CWE-94
Description: CWE-94: Improper Control of Generation of Code ('Code Injection')
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2020-070-04/
x_refsource_MISC
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-070-04/
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2020-070-04/
x_refsource_MISC
x_transferred
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-070-04/
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:23 Mar, 2020 | 20:15
Updated At:25 Mar, 2020 | 14:46

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.07.5HIGH
AV:N/AC:L/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 7.5
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:P/I:P/A:P
CPE Matches

Schneider Electric SE
schneider-electric
>>andover_continuum_9680_firmware>>*
cpe:2.3:o:schneider-electric:andover_continuum_9680_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9680>>-
cpe:2.3:h:schneider-electric:andover_continuum_9680:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_5740_firmware>>*
cpe:2.3:o:schneider-electric:andover_continuum_5740_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_5740>>-
cpe:2.3:h:schneider-electric:andover_continuum_5740:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_5720_firmware>>*
cpe:2.3:o:schneider-electric:andover_continuum_5720_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_5720>>-
cpe:2.3:h:schneider-electric:andover_continuum_5720:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_bcx4040_firmware>>*
cpe:2.3:o:schneider-electric:andover_continuum_bcx4040_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_bcx4040>>-
cpe:2.3:h:schneider-electric:andover_continuum_bcx4040:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_bcx9640_firmware>>*
cpe:2.3:o:schneider-electric:andover_continuum_bcx9640_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_bcx9640>>-
cpe:2.3:h:schneider-electric:andover_continuum_bcx9640:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9900_firmware>>*
cpe:2.3:o:schneider-electric:andover_continuum_9900_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9900>>-
cpe:2.3:h:schneider-electric:andover_continuum_9900:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9940_firmware>>*
cpe:2.3:o:schneider-electric:andover_continuum_9940_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9940>>-
cpe:2.3:h:schneider-electric:andover_continuum_9940:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9941_firmware>>*
cpe:2.3:o:schneider-electric:andover_continuum_9941_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9941>>-
cpe:2.3:h:schneider-electric:andover_continuum_9941:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9924_firmware>>*
cpe:2.3:o:schneider-electric:andover_continuum_9924_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9924>>-
cpe:2.3:h:schneider-electric:andover_continuum_9924:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9702_firmware>>*
cpe:2.3:o:schneider-electric:andover_continuum_9702_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9702>>-
cpe:2.3:h:schneider-electric:andover_continuum_9702:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9200_firmware>>*
cpe:2.3:o:schneider-electric:andover_continuum_9200_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>andover_continuum_9200>>-
cpe:2.3:h:schneider-electric:andover_continuum_9200:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-94Primarynvd@nist.gov
CWE-94Secondarycybersecurity@se.com
CWE ID: CWE-94
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-94
Type: Secondary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.se.com/ww/en/download/document/SEVD-2020-070-04/cybersecurity@se.com
Vendor Advisory
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-070-04/
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1772Records found

CVE-2019-6823
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-9.62% / 93.08%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:41
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Action-Not Available
Vendor-Schneider Electric SE
Product-proclimaProClima all versions prior to version 8.0.0
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2023-25550
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-1.75% / 83.04%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:36
Updated-12 Feb, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2023-25549
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-1.75% / 83.04%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:35
Updated-03 Mar, 2025 | 19:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2016-8352
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||CRITICAL
EPSS-2.50% / 85.71%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-connexium_firmwaretcsefec23f3f21tcsefec23fcf20tcsefec23f3f20tcsefec2cf3f20tcsefec23fcf21Schneider Electric ConneXium TCSEFEC2*
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2016-5815
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.88% / 75.79%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-ion5000ion8650ion8800ion7300ion7500ion7600Schneider Electric IONXXXX Series Power Meter Vulnerabilities
CWE ID-CWE-284
Improper Access Control
CVE-2018-7229
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.51% / 66.99%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2018-7836
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.32% / 85.19%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow upload and execution of malicious files.

Action-Not Available
Vendor-
Product-iiot_monitorIIoT Monitor 3.1.38
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2018-7780
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.52% / 67.19%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 00:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".

Action-Not Available
Vendor-
Product-imp519-1er_firmwareimp319-1eribp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimps110-1_firmwareibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimps110-1imp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1erimp319-1Pelco Sarix Professional V1
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7233
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.14% / 78.91%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-17 Sep, 2024 | 01:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7846
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-63.24% / 98.43%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:57
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2021-22765
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.61% / 70.24%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-29 May, 2026 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_egx300_firmwarepowerlogic_egx100_firmwarepowerlogic_egx100powerlogic_egx300PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7820
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.28% / 52.09%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:45
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.

Action-Not Available
Vendor-
Product-ap9630ap9631ap9635smart-ups_srt_5kvaap9635_firmwareap9630_firmwaresmart-ups_srt_5kva_firmwareap9631_firmwareAPC UPS Network Management Card 2 AOS
CWE ID-CWE-255
Not Available
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2018-7761
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.55% / 68.46%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.

Action-Not Available
Vendor-
Product-140cpu65160ctsxp573634mmodicon_m340_bmxp3420302h_firmware140cpu65160_firmwaretsxh5744m_firmwaremodicon_m340_bmxp342020h_firmwaretsxh5744m140cpu65160s_firmwaretsxp571634mcmodicon_m340_bmxp3420102cltsxp574634m_firmwaremodicon_m340_bmxp3420302_firmwaretsxp575634mtsxh5724mc_firmwaretsxp57304mc140cpu65860tsxp575634mc140cpu65160modicon_m340_bmxp3420302cl_firmwaretsxh5744mc_firmwaretsxp573634mc_firmwaremodicon_m340_bmxp342020_firmwaretsxp57454m_firmwaretsxp57254m_firmwaremodicon_m340_bmxp3420102_firmwaretsxp572634mtsxp57554mc_firmwaretsxp574634mtsxh5724mtsxp57304m_firmwaretsxp571634mc_firmwaretsxp57454mcmodicon_m340_bmxp341000h140cpu65160sbmxnor0200_firmwaremodicon_m340_bmxp3420302clbmxnor0200htsxp574634mc_firmwaretsxp57154mctsxp57154m_firmwaretsxp57154mtsxp576634mtsxh5744mctsxp57204mcmodicon_m340_bmxp342020140cpu31110modicon_m340_bmxp342020htsxp57354mc_firmwaretsxp57104m140cpu65150c_firmwaretsxp57354m140cpu65150_firmwaremodicon_m340_bmxp342000_firmware140cpu65860cbmxnor0200h_firmwaretsxp57204m_firmwaretsxp57204m140cpu65260tsxp571634m_firmwaretsxp573634mc140cpu43412uc140cpu65150tsxp571634mtsxp57304mc_firmware140cpu65860_firmwarebmxnor0200modicon_m340_bmxp341000h_firmware140cpu65260ctsxp57354mc140cpu65150c140cpu43412u_firmwaretsxh5724m_firmwaremodicon_m340_bmxp342000tsxp575634m_firmwaretsxp573634m_firmwaretsxp57204mc_firmwaretsxp57104mc_firmwaremodicon_m340_bmxp341000tsxh5724mc140cpu65260c_firmwaretsxp57254mc_firmware140cpu31110_firmware140cpu31110ctsxp57304mtsxp576634mcmodicon_m340_bmxp3420302htsxp574634mcmodicon_m340_bmxp3420102cl_firmwaretsxp572634mc_firmwaretsxp57454mc_firmwaretsxp576634mc_firmwaretsxp57554mctsxp575634mc_firmware140cpu65160c_firmwaretsxp576634m_firmware140cpu65260_firmwaremodicon_m340_bmxp3420302140cpu43412uc_firmwaretsxp57454mtsxp572634mcmodicon_m340_bmxp341000_firmwaretsxp57254mtsxp57104m_firmwaretsxp572634m_firmwaretsxp57554mtsxp57254mctsxp57354m_firmwaretsxp57104mctsxp57554m_firmwaremodicon_m340_bmxp3420102140cpu31110c_firmware140cpu43412utsxp57154mc_firmware140cpu65860c_firmwareModicon M340, Modicon Premium, Modicon Quantum, BMXNOR0202
CWE ID-CWE-20
Improper Input Validation
CVE-2021-22729
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.35% / 57.73%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:44
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-259
Use of Hard-coded Password
CVE-2018-7232
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.14% / 78.91%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-17 Sep, 2024 | 00:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7784
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.74% / 73.54%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application.

Action-Not Available
Vendor-
Product-u.motionU.motion Builder
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7842
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-10.13% / 93.29%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:59
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-290
Authentication Bypass by Spoofing
CVE-2018-7791
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.35% / 58.21%
||
7 Day CHG~0.00%
Published-29 Aug, 2018 | 21:00
Updated-29 May, 2026 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC.

Action-Not Available
Vendor-Schneider Electric SE
Product-modicon_m221_firmwaremodicon_m221Modicon M221, all references, all versions prior to firmware V1.6.2.0
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-287
Improper Authentication
CVE-2018-7228
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.69% / 72.43%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 23:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-287
Improper Authentication
CVE-2018-7847
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.77% / 74.05%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-287
Improper Authentication
CVE-2018-7778
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.66% / 71.61%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 01:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.

Action-Not Available
Vendor-
Product-evlink_charging_stationevlink_charging_station_firmwareEvlink Charging Station
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2018-7785
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-8.17% / 92.40%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.

Action-Not Available
Vendor-
Product-u.motion_builderU.motion Builder
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-29412
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.54% / 85.83%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:50
Updated-05 Feb, 2025 | 21:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-29411
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-7.71% / 92.14%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:49
Updated-05 Feb, 2025 | 21:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-6840
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.50% / 66.68%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:19
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to send a crafted message to the target server, thereby causing arbitrary commands to be executed.

Action-Not Available
Vendor-
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0002meg6501-0001_firmwaremeg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Server
CWE ID-CWE-134
Use of Externally-Controlled Format String
CVE-2020-7522
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.73% / 73.26%
||
7 Day CHG~0.00%
Published-31 Aug, 2020 | 16:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `SoundUploadServlet` which may lead to uploading executable files to non-specified directories.

Action-Not Available
Vendor-n/a
Product-apc_easy_ups_online_softwareSFAPV9601 - APC Easy UPS On-Line Software V2.0 and earlier
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-28004
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.28% / 80.08%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 21:16
Updated-02 Aug, 2024 | 12:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution.

Action-Not Available
Vendor-
Product-powerlogic_hdpm6000_firmwarepowerlogic_hdpm6000PowerLogic HDPM6000
CWE ID-CWE-129
Improper Validation of Array Index
CVE-2024-6407
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 60.74%
||
7 Day CHG~0.00%
Published-11 Jul, 2024 | 09:07
Updated-01 Aug, 2024 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

Action-Not Available
Vendor-
Product-whc-5918awhc-5918a_firmwareWiser Home Controller WHC-5918A
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-1126
Matching Score-8
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-8
Assigner-Red Hat, Inc.
CVSS Score-4.8||MEDIUM
EPSS-0.33% / 56.08%
||
7 Day CHG-0.16%
Published-23 May, 2018 | 13:00
Updated-17 Dec, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124.

Action-Not Available
Vendor-procps-ng_project[UNKNOWN]Red Hat, Inc.Debian GNU/LinuxCanonical Ltd.
Product-enterprise_linux_serverubuntu_linuxdebian_linuxprocps-ngenterprise_linux_server_ausenterprise_linux_workstationenterprise_linuxenterprise_linux_server_tusenterprise_linux_desktopstruxureware_data_center_expertprocps-ng, procps
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2017-9957
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.44% / 63.87%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2017-9629
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-19.70% / 95.59%
||
7 Day CHG~0.00%
Published-07 Jul, 2017 | 17:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_archestra_loggerSchneider Electric Wonderware ArchestrA Logger
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-46680
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.16% / 36.94%
||
7 Day CHG+0.02%
Published-22 May, 2023 | 13:25
Updated-21 Jan, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.

Action-Not Available
Vendor-Schneider Electric SE
Product-powerlogic_ion8650powerlogic_ion9000_firmwarepowerlogic_ion9000powerlogic_pm8000powerlogic_pm8000_firmwarepowerlogic_ion7400_firmwarepowerlogic_ion8800_firmwarepowerlogic_ion8800powerlogic_ion7400powerlogic_ion8650_firmwarePowerLogic ION9000PowerLogic ION8800Legacy ION products PowerLogic PM8000PowerLogic ION7400PowerLogic ION8650
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2022-32513
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.48% / 65.61%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-5500ac2_firmware5500shaclss5500nac5500ac2lss5500shaclss5500nac_firmwarelss5500shac_firmware5500nac_firmware5500nac5500nac25500shac_firmware5500nac2_firmwareClipsal C-Bus Network Automation Controller, 5500NACSpaceLogic C-Bus Network Automation Controller, 5500NAC2Clipsal Wiser for C-Bus Automation Controller, 5500SHACWiser for C-Bus Automation Controller, LSS5500SHACSpaceLogic C-Bus Application Controller, 5500AC2C-Bus Network Automation Controller, LSS5500NAC
CWE ID-CWE-521
Weak Password Requirements
CVE-2022-32519
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.38% / 59.98%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-257
Storing Passwords in a Recoverable Format
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-32527
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.77% / 83.13%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-42971
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.58% / 85.94%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_7windows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring SoftwareAPC Easy UPS Online Monitoring Software
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2017-9956
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.3||HIGH
EPSS-0.49% / 65.92%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2022-32515
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.26% / 49.48%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)

Action-Not Available
Vendor-Schneider Electric SE
Product-conext_comboxconext_combox_firmwareConext™ ComBox
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2022-32529
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.77% / 83.13%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32514
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 64.67%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-5500ac2_firmware5500shaclss5500nac5500ac2lss5500shaclss5500nac_firmwarelss5500shac_firmware5500nac_firmware5500nac5500nac25500shac_firmware5500nac2_firmwareClipsal C-Bus Network Automation Controller, 5500NACSpaceLogic C-Bus Network Automation Controller, 5500NAC2Clipsal Wiser for C-Bus Automation Controller, 5500SHACWiser for C-Bus Automation Controller, LSS5500SHACSpaceLogic C-Bus Application Controller, 5500AC2C-Bus Network Automation Controller, LSS5500NAC
CWE ID-CWE-287
Improper Authentication
CVE-2022-34756
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.87% / 83.57%
||
7 Day CHG~0.00%
Published-13 Jul, 2022 | 21:10
Updated-17 Sep, 2024 | 04:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior)

Action-Not Available
Vendor-
Product-easergy_p5_firmwareeasergy_p5Easergy P5
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32518
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.38% / 59.98%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-32525
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.60% / 86.00%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32522
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.77% / 83.13%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2017-7973
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.34% / 56.95%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A SQL injection vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can use calls to various paths allowing performance of arbitrary SQL commands against the underlying database.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-30234
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.4||CRITICAL
EPSS-0.37% / 59.06%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-16 Sep, 2024 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-wiser_smart_eer21000wiser_smart_eer21001_firmwarewiser_smart_eer21000_firmwarewiser_smart_eer21001Wiser Smart
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2022-30235
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.27% / 50.95%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-16 Sep, 2024 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-wiser_smart_eer21000wiser_smart_eer21001_firmwarewiser_smart_eer21000_firmwarewiser_smart_eer21001Wiser Smart
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2022-24312
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.75% / 83.04%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-26507
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-6.70% / 91.48%
||
7 Day CHG~0.00%
Published-14 Apr, 2022 | 12:04
Updated-03 Aug, 2024 | 05:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

Action-Not Available
Vendor-attn/a
Product-ecostruxure_process_expertecostruxure_control_expertremoteconnectxmillscadapack_470scadapack_570scadapack_574scadapack_575scadapack_474n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2017-7974
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-7.32% / 91.90%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A path traversal information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can execute arbitrary code and exfiltrate files.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')