Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.
An issue was discovered on D-Link DSL-2888A devices with firmware prior to AU_2.31_V1.1.47ae55. An unauthenticated attacker could bypass authentication to access authenticated pages and functionality.
Sensitive information disclosure in NetScaler Console
When a non-x86 platform is detected, cloud-init grants root access to a hardcoded url with a local IP address. To prevent this, cloud-init default configurations disable platform enumeration.
An issue was discovered on HMS Anybus X-Gateway AB7832-F firmware version 3. The HICP protocol allows unauthenticated changes to a device's network configurations.
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
DIGITUS DA-70254 4-Port Gigabit Network Hub 2.073.000.E0008 devices allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.
TP-Link USB Network Server TL-PS310U devices before 2.079.000.t0210 allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.
Lindy 42633 4-Port USB 2.0 Gigabit Network Server 2.078.000 devices allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.
Tenda W18E V16.01.0.8(1625) suffers from authentication bypass in the web management portal allowing an unauthorized remote attacker to gain administrative access by sending a specially crafted HTTP request.
An issue was discovered on NETGEAR Orbi Tri-Band Business WiFi Add-on Satellite (SRS60) AC3000 V2.5.1.106, Outdoor Satellite (RBS50Y) V2.5.1.106, and Pro Tri-Band Business WiFi Router (SRR60) AC3000 V2.5.1.106. The administrative SOAP interface allows an unauthenticated remote write of arbitrary Wi-Fi configuration data such as authentication details (e.g., the Web-admin password), network settings, DNS settings, system administration interface configuration, etc.
TrackR Bravo device allows unauthenticated pairing, which enables unauthenticated connected applications to write to various device attributes. Updated apps, version 5.1.6 for iOS and 2.2.5 for Android, have been released by the vendor to address the vulnerabilities in CVE-2016-6538, CVE-2016-6539, CVE-2016-6540 and CVE-2016-6541.
Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.
Improper Authentication vulnerability in ABB Symphony Plus S+ Operations.This issue affects Symphony Plus S+ Operations: from 2.X through 2.1 SP2, 2.2, from 3.X through 3.3 SP1, 3.3 SP2.
The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the username and cleartext password of the user. An attacker can then supply an IDALToken value in a cookie, which will allow them to perform privileged operations such as restarting the service with /cgi/restart. A GET request to /cgi/loginDefaultUser may result in "1 #S_OK IDALToken=532c8632b86694f0232a68a0897a145c admin admin" or a similar response.
There is an insufficient authentication vulnerability in Huawei Band 2 and Honor Band 3. The band does not sufficiently authenticate the device try to connect to it in certain scenario. Successful exploit could allow the attacker to spoof then connect to the band.
iDoors Reader 2.10.17 and earlier allows an attacker on the same network segment to bypass authentication to access the management console and operate the product via unspecified vectors.
The WAVLINK Quantum D4G (WN531G3) running firmware version M31G3.V5030.200325 uses IP addresses to hold sessions and does not not use session tokens. Therefore, if an attacker changes their IP address to match the logged-in administrator's, or is behind the same NAT as the logged in administrator, session takeover is possible.
OpenHarmony-v3.1.1 and prior versions have a permission bypass vulnerability. LAN attackers can bypass permission control and get control of camera service.
D-Link DAP-1860 devices before v1.04b03 Beta allow access to administrator functions without authentication via the HNAP_AUTH header timestamp value. In HTTP requests, part of the HNAP_AUTH header is the timestamp used to determine the time when the user sent the request. If this value is equal to the value stored in the device's /var/hnap/timestamp file, the request will pass the HNAP_AUTH check function.
A support user exists on the device and appears to be a backdoor for Technical Support staff. The default password for this account is “support” and cannot be changed by a user via any normally accessible means.
Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
DrayTek Vigor310 devices through 4.3.2.6 use unencrypted HTTP for authentication requests.
ZTE ZXHN H168N product with versions V2.2.0_PK1.2T5, V2.2.0_PK1.2T2, V2.2.0_PK11T7 and V2.2.0_PK11T have an improper change control vulnerability, which may allow an unauthorized user to perform unauthorized operations.
A vulnerability in the Netgear DGN2200 router with firmware version v1.0.0.46 and earlier permits unauthorized individuals to bypass the authentication. When adding "?x=1.gif" to the the requested url, it will be recognized as passing the authentication.
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link DAP-2610 Firmware v2.01RC067 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of passwords. The issue results from the lack of proper password checking. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-10082.
An authentication bypass vulnerability was reported in Lenovo ThinkPad Stack Wireless Router firmware version 1.1.3.4 that could allow escalation of privilege.
The NSDP protocol implementation on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices was affected by an authentication issue that allows an attacker to bypass access controls and obtain full control of the device.
Improper input validation in BLE prior to SMR Jul-2024 Release 1 allows adjacent attackers to trigger abnormal behavior.
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link DIR-1935 1.03 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of HNAP login requests. The issue results from the lack of proper implementation of the authentication algorithm. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-16142.
Waybox Enel X web management API authentication could be bypassed and provide administrator’s privileges over the Waybox system.
OpenHarmony-v3.1.2 and prior versions have an authenication bypass vulnerability in a callback handler function of Softbus_server in communication subsystem. Attackers can launch attacks on distributed networks by sending Bluetooth rfcomm packets to any remote device and executing arbitrary commands.
A vulnerability has been found in harrystech Dynosaur-Rails and classified as critical. Affected by this vulnerability is the function basic_auth of the file app/controllers/application_controller.rb. The manipulation leads to improper authentication. This product does not use versioning. This is why information about affected and unaffected releases are unavailable. The patch is named 04b223813f0e336aab50bff140d0f5889c31dbec. It is recommended to apply a patch to fix this issue. The associated identifier of this vulnerability is VDB-221503.
Authentication bypass vulnerability in multiple Buffalo network devices allows a network-adjacent attacker to bypass authentication and access the device. The affected products/versions are as follows: WCR-300 firmware Ver. 1.87 and earlier, WHR-HP-G300N firmware Ver. 2.00 and earlier, WHR-HP-GN firmware Ver. 1.87 and earlier, WPL-05G300 firmware Ver. 1.88 and earlier, WRM-D2133HP firmware Ver. 2.85 and earlier, WRM-D2133HS firmware Ver. 2.96 and earlier, WTR-M2133HP firmware Ver. 2.85 and earlier, WTR-M2133HS firmware Ver. 2.96 and earlier, WXR-1900DHP firmware Ver. 2.50 and earlier, WXR-1900DHP2 firmware Ver. 2.59 and earlier, WXR-1900DHP3 firmware Ver. 2.63 and earlier, WXR-5950AX12 firmware Ver. 3.40 and earlier, WXR-6000AX12B firmware Ver. 3.40 and earlier, WXR-6000AX12S firmware Ver. 3.40 and earlier, WZR-300HP firmware Ver. 2.00 and earlier, WZR-450HP firmware Ver. 2.00 and earlier, WZR-600DHP firmware Ver. 2.00 and earlier, WZR-900DHP firmware Ver. 1.15 and earlier, WZR-1750DHP2 firmware Ver. 2.31 and earlier, WZR-HP-AG300H firmware Ver. 1.76 and earlier, WZR-HP-G302H firmware Ver. 1.86 and earlier, WEM-1266 firmware Ver. 2.85 and earlier, WEM-1266WP firmware Ver. 2.85 and earlier, WLAE-AG300N firmware Ver. 1.86 and earlier, FS-600DHP firmware Ver. 3.40 and earlier, FS-G300N firmware Ver. 3.14 and earlier, FS-HP-G300N firmware Ver. 3.33 and earlier, FS-R600DHP firmware Ver. 3.40 and earlier, BHR-4GRV firmware Ver. 2.00 and earlier, DWR-HP-G300NH firmware Ver. 1.84 and earlier, DWR-PG firmware Ver. 1.83 and earlier, HW-450HP-ZWE firmware Ver. 2.00 and earlier, WER-A54G54 firmware Ver. 1.43 and earlier, WER-AG54 firmware Ver. 1.43 and earlier, WER-AM54G54 firmware Ver. 1.43 and earlier, WER-AMG54 firmware Ver. 1.43 and earlier, WHR-300 firmware Ver. 2.00 and earlier, WHR-300HP firmware Ver. 2.00 and earlier, WHR-AM54G54 firmware Ver. 1.43 and earlier, WHR-AMG54 firmware Ver. 1.43 and earlier, WHR-AMPG firmware Ver. 1.52 and earlier, WHR-G firmware Ver. 1.49 and earlier, WHR-G300N firmware Ver. 1.65 and earlier, WHR-G301N firmware Ver. 1.87 and earlier, WHR-G54S firmware Ver. 1.43 and earlier, WHR-G54S-NI firmware Ver. 1.24 and earlier, WHR-HP-AMPG firmware Ver. 1.43 and earlier, WHR-HP-G firmware Ver. 1.49 and earlier, WHR-HP-G54 firmware Ver. 1.43 and earlier, WLI-H4-D600 firmware Ver. 1.88 and earlier, WS024BF firmware Ver. 1.60 and earlier, WS024BF-NW firmware Ver. 1.60 and earlier, WXR-1750DHP firmware Ver. 2.60 and earlier, WXR-1750DHP2 firmware Ver. 2.60 and earlier, WZR-1166DHP firmware Ver. 2.18 and earlier, WZR-1166DHP2 firmware Ver. 2.18 and earlier, WZR-1750DHP firmware Ver. 2.30 and earlier, WZR2-G300N firmware Ver. 1.55 and earlier, WZR-450HP-CWT firmware Ver. 2.00 and earlier, WZR-450HP-UB firmware Ver. 2.00 and earlier, WZR-600DHP2 firmware Ver. 1.15 and earlier, WZR-600DHP3 firmware Ver. 2.19 and earlier, WZR-900DHP2 firmware Ver. 2.19 and earlier, WZR-AGL300NH firmware Ver. 1.55 and earlier, WZR-AMPG144NH firmware Ver. 1.49 and earlier, WZR-AMPG300NH firmware Ver. 1.51 and earlier, WZR-D1100H firmware Ver. 2.00 and earlier, WZR-G144N firmware Ver. 1.48 and earlier, WZR-G144NH firmware Ver. 1.48 and earlier, WZR-HP-G300NH firmware Ver. 1.84 and earlier, WZR-HP-G301NH firmware Ver. 1.84 and earlier, WZR-HP-G450H firmware Ver. 1.90 and earlier, WZR-S1750DHP firmware Ver. 2.32 and earlier, WZR-S600DHP firmware Ver. 2.19 and earlier, and WZR-S900DHP firmware Ver. 2.19 and earlier.
An issue was discovered on Vgate iCar 2 Wi-Fi OBD2 Dongle devices. The OBD port is used to receive measurement data and debug information from the car. This on-board diagnostics feature can also be used to send commands to the car (different for every vendor / car product line / car). No authentication is needed, which allows attacks from the local Wi-Fi network.
Open5GS 2.1.3 listens on 0.0.0.0:3000 and has a default password of 1423 for the admin account.
An improper authentication vulnerability in FSSO Collector version 5.0.295 and below may allow an unauthenticated user to bypass a FSSO firewall policy and access the protected network via sending specifically crafted UDP login notification packets.
There is no account authentication and permission check logic in the firmware and existing apps of SiHAS's SGW-300, ACM-300, GCM-300, so unauthorized users can remotely control the device.
OpenBlocks IoT VX2 prior to Ver.4.0.0 (Ver.3 Series) allows an attacker on the same network segment to bypass authentication and to initialize the device via unspecified vectors.
NETGEAR DGN2200v1 devices before v1.0.0.60 mishandle HTTPd authentication (aka PSV-2020-0363, PSV-2020-0364, and PSV-2020-0365).