Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack.
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.34), Mendix Applications using Mendix 8 (All versions < V8.18.23), Mendix Applications using Mendix 9 (All versions < V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions < V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.15). Some of the Mendix runtime API’s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors.
A vulnerability has been identified in Siemens OPC UA Modelling Editor (SiOME) (All versions < V2.8). Affected products suffer from a XML external entity (XXE) injection vulnerability. This vulnerability could allow an attacker to interfere with an application's processing of XML data and read arbitrary files in the system.
AES OCB mode for 32-bit x86 platforms using the AES-NI assembly optimised implementation will not encrypt the entirety of the data under some circumstances. This could reveal sixteen bytes of data that was preexisting in the memory that wasn't written. In the special case of "in place" encryption, sixteen bytes of the plaintext would be revealed. Since OpenSSL does not support OCB based cipher suites for TLS and DTLS, they are both unaffected. Fixed in OpenSSL 3.0.5 (Affected 3.0.0-3.0.4). Fixed in OpenSSL 1.1.1q (Affected 1.1.1-1.1.1p).
A vulnerability has been identified in COMOS (All versions < V10.4.4). Caching system in the affected application leaks sensitive information such as user and project information in cleartext via UDP.
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information.
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.
A vulnerability has been identified in SICAM A8000 CP-8031 (All versions < V4.80), SICAM A8000 CP-8050 (All versions < V4.80). Affected devices do not require an user to be authenticated to access certain files. This could allow unauthenticated attackers to download these files.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The password used for authentication for the LOGO! Website and the LOGO! Access Tool is sent in a recoverable format. An attacker with access to the network traffic could derive valid logins.
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port 8080/tcp.
A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions < V1.6.284.0). Affected applications insufficiently limit the access to the internal message broker system. This could allow an unauthenticated remote attacker to subscribe to arbitrary message queues.
A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i801, RUGGEDCOM i802, RUGGEDCOM i803, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM RMC30, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RP110, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600T, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS401, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000H, RUGGEDCOM RS8000T, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900L, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS969, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSL910, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. A timing attack, in a third-party component, could make the retrieval of the private key possible, used for encryption of sensitive data. If a threat actor were to exploit this, the data integrity and security could be compromised.
A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions < V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information.
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The login functionality of the application does not employ any countermeasures against Password Spraying attacks or Credential Stuffing attacks. An attacker could obtain a list of valid usernames on the device by exploiting the issue and then perform a precise Password Spraying or Credential Stuffing attack in order to obtain access to at least one account.
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). By performing a flooding attack against the web server, an attacker might be able to gain read access to the device's memory, possibly revealing confidential information.
UltraVNC revision 1198 contains multiple memory leaks (CWE-655) in VNC client code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199.
UltraVNC revision 1211 contains multiple memory leaks (CWE-665) in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems.
A vulnerability has been identified in XHQ (All Versions < 6.1). The application's web server could expose non-sensitive information about the server's architecture. This could allow an attacker to adapt further attacks to the version in place.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to directory listings of the server by sending specifically crafted packets to 80/tcp, 8095/tcp or 8080/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. A remote attacker with network access to the CCS server could exploit this vulnerability to read the CCS users database, including the passwords of all users in obfuscated cleartext.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to path and filenames on the server by sending specifically crafted packets to 1099/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The Application Server exposes directory listings and files containing sensitive information. This vulnerability is independent from CVE-2019-18286. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to enumerate valid user names by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the network.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)
The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to obtain sensitive information from process memory via a crafted packets, aka "Windows SMB Information Disclosure Vulnerability."
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to gain access to logs and configuration files by sending specifically crafted packets to 80/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to filenames on the server by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets.
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not properly enforce restriction of excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys.
A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application.
Node.js before 16.4.1, 14.17.2, 12.22.2 is vulnerable to an out-of-bounds read when uv__idna_toascii() is used to convert strings to ASCII. The pointer p is read and increased without checking whether it is beyond pe, with the latter holding a pointer to the end of the buffer. This can lead to information disclosures or crashes. This function can be triggered via uv_getaddrinfo().
curl 7.1.1 to and including 7.75.0 is vulnerable to an "Exposure of Private Personal Information to an Unauthorized Actor" by leaking credentials in the HTTP Referer: header. libcurl does not strip off user credentials from the URL when automatically populating the Referer: HTTP request header field in outgoing HTTP requests, and therefore risks leaking sensitive data to the server that is the target of the second HTTP request.
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0 < V5.0.2), SiNVR/SiVMS Video Server (All versions >= V5.0.2). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server applies weak cryptography when exposing device (camera) passwords. This could allow an unauthenticated remote attacker to read and decrypt the passwords and conduct further attacks.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The Application Server exposes directory listings and files containing sensitive information. This vulnerability is independent from CVE-2019-18287. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could be able to enumerate running RPC services. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability. A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.
LibVNC commit before d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a contains a memory leak (CWE-655) in VNC server code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appear to be exploitable via network connectivity. These vulnerabilities have been fixed in commit d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a.
A vulnerability has been identified in OZW672 (All versions < V10.00), OZW772 (All versions < V10.00). Vulnerable versions of OZW Web Server use predictable path names for project files that legitimately authenticated users have created by using the application's export function. By accessing a specific uniform resource locator on the web server, a remote attacker could be able to download a project file without prior authentication. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected system. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system.
Wind River VxWorks 6.5, 6.6, 6.7, 6.8, 6.9.3 and 6.9.4 has a Memory Leak in the IGMPv3 client component. There is an IPNET security vulnerability: IGMP Information leak via IGMPv3 specific membership report.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SINEMA Server (All versions < V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known