Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2022-24318

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-09 Feb, 2022 | 22:05
Updated At-03 Aug, 2024 | 04:07
Rejected At-
Credits

A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:09 Feb, 2022 | 22:05
Updated At:03 Aug, 2024 | 04:07
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

Affected Products
Vendor
n/a
Product
ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
Versions
Affected
  • ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
Problem Types
TypeCWE IDDescription
CWECWE-326CWE-326: Inadequate Encryption Strength
Type: CWE
CWE ID: CWE-326
Description: CWE-326: Inadequate Encryption Strength
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05
x_refsource_MISC
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05
x_refsource_MISC
x_transferred
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:09 Feb, 2022 | 23:15
Updated At:17 Feb, 2022 | 04:08

A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary2.05.0MEDIUM
AV:N/AC:L/Au:N/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Type: Primary
Version: 2.0
Base score: 5.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:N/C:P/I:N/A:N
CPE Matches

Schneider Electric SE
schneider-electric
>>clearscada>>*
cpe:2.3:a:schneider-electric:clearscada:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>ecostruxure_geo_scada_expert_2019>>*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>ecostruxure_geo_scada_expert_2020>>*
cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-326Primarynvd@nist.gov
CWE-326Secondarycybersecurity@se.com
CWE ID: CWE-326
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-326
Type: Secondary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05cybersecurity@se.com
Patch
Vendor Advisory
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05
Source: cybersecurity@se.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

213Records found

CVE-2017-9965
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.8||MEDIUM
EPSS-1.88% / 82.39%
||
7 Day CHG~0.00%
Published-02 Jan, 2018 | 03:00
Updated-17 Sep, 2024 | 03:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files.

Action-Not Available
Vendor-
Product-pelco_videoxpertPelco VideoXpert Enterprise
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2017-9960
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.65%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system response to error provides more information than should be available to an unauthenticated user.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-22732
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-3.9||LOW
EPSS-0.12% / 31.07%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_commissionEcoStruxure Power Commission
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2017-6032
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.3||MEDIUM
EPSS-0.46% / 63.07%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modbus_firmwaremodbusSchneider Electric Modicon Modbus Protocol
CWE ID-CWE-358
Improperly Implemented Security Check for Standard
CWE ID-CWE-657
Violation of Secure Design Principles
CVE-2020-7519
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.28% / 50.64%
||
7 Day CHG~0.00%
Published-23 Jul, 2020 | 20:51
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-521: Weak Password Requirements vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to compromise a user account.

Action-Not Available
Vendor-n/a
Product-easergy_builderEasergy Builder (Version 1.4.7.2 and older)
CWE ID-CWE-521
Weak Password Requirements
CVE-2011-4036
Matching Score-8
Assigner-CERT/CC
ShareView Details
Matching Score-8
Assigner-CERT/CC
CVSS Score-5||MEDIUM
EPSS-0.51% / 65.22%
||
7 Day CHG~0.00%
Published-02 Dec, 2011 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-vijeo_historiancitectscada_reportscitecthistoriann/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-6407
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.38% / 58.48%
||
7 Day CHG+0.16%
Published-11 Jul, 2024 | 09:07
Updated-01 Aug, 2024 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

Action-Not Available
Vendor-
Product-whc-5918awhc-5918a_firmwareWiser Home Controller WHC-5918A
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6851
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.44% / 62.40%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:55
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol.

Action-Not Available
Vendor-n/a
Product-tsxmrpc001m_firmwaretsxmrpc002m_firmwaretsxmrpp384ktsxmfpp002m_firmwaremodicon_m580_firmwaretsxmrpc448k_firmwaretsxmrpf008mtsxmrpp384k_firmwaretsxmcpc002m_firmwaretsxmrpf004mtsxmrpc768ktsxmrpc01m7tsxmrpp224kmodicon_m580tsxmrpc01m7_firmwaretsxmfp064p2tsxmrpc003m_firmwaretsxmrpc001mtsxmfpp224ktsxmrpc002mtsxmfpp004mtsxmfpp001m_firmwaretsxmrpc768k_firmwaretsxmfpp001mtsxmrpp224k_firmwaretsxmrpc007m_firmwaretsxmfpp512k_firmwaretsxmfpp224k_firmwaretsxmfp0128p2tsxmrpc007mtsxmcpc002mmodicon_m340tsxmfpp384ktsxmrpf008m_firmwaretsxmcpc512ktsxmfp0128p2_firmwaretsxmcpc512k_firmwaretsxmfpp512ktsxmrpf004m_firmwaretsxmfp064p2_firmwaretsxmrpc003mtsxmfpp002mtsxmfpp384k_firmwaretsxmrpc448ktsxmfpp004m_firmwaremodicon_m340_firmwareModicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)
CWE ID-CWE-538
Insertion of Sensitive Information into Externally-Accessible File or Directory
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6852
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.35% / 56.59%
||
7 Day CHG~0.00%
Published-20 Nov, 2019 | 22:01
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.

Action-Not Available
Vendor-
Product-tsx_ety_x103_firmwarebmx_noe_0100140_noc_78x00140_noe_771x1bmx_noe_0110tsx_ety_x103bmx_noc_0401_firmware140_cpu6x_firmwarebmx_p34x140_noc_78x00_firmware140_noe_771x1_firmware140_cpu6xtsx_p57xbmx_p34x_firmwarebmx_noe_0110_firmware140_noc_77101_firmwarebmx_noc_0401tsx_p57x_firmware140_noc_77101bmx_noe_0100_firmwareModicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions)
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6845
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.21% / 42.75%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:49
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol.

Action-Not Available
Vendor-n/a
Product-tsxmrpc001m_firmwaretsxmrpc002m_firmwaretsxmrpp384ktsxmfpp002m_firmwaremodicon_m580_firmwaretsxmrpc448k_firmwaretsxmrpf008mtsxmrpp384k_firmwaretsxmcpc002m_firmwaretsxmrpf004mtsxmrpc768ktsxmrpc01m7tsxmrpp224kmodicon_m580tsxmrpc01m7_firmwaretsxmfp064p2tsxmrpc003m_firmwaretsxmrpc001mtsxmfpp224ktsxmrpc002mtsxmfpp004mtsxmfpp001m_firmwaretsxmrpc768k_firmwaretsxmfpp001mtsxmrpp224k_firmwaretsxmrpc007m_firmwaretsxmfpp512k_firmwaretsxmfpp224k_firmwaretsxmfp0128p2tsxmrpc007mtsxmcpc002mmodicon_m340tsxmfpp384ktsxmrpf008m_firmwaretsxmcpc512ktsxmfp0128p2_firmwaretsxmcpc512k_firmwaretsxmfpp512ktsxmrpf004m_firmwaretsxmfp064p2_firmwaretsxmrpc003mtsxmfpp002mtsxmfpp384k_firmwaretsxmrpc448ktsxmfpp004m_firmwaremodicon_m340_firmwareModicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2019-6806
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.34% / 56.02%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:04
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CVE-2019-6859
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.34% / 56.27%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 18:14
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hardcoded Credentials vulnerability exists in Modicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.

Action-Not Available
Vendor-n/a
Product-tsx_ety_x103_firmwarebmx_noe_0100140_noc_78x00140_noe_771x1bmx_noe_0110tsx_ety_x103bmx_noc_0401_firmware140_cpu6x_firmwarebmx_p34x140_noc_78x00_firmware140_noe_771x1_firmware140_cpu6xtsx_p57xbmx_p34x_firmwarebmx_noe_0110_firmware140_noc_77101_firmwarebmx_noc_0401tsx_p57x_firmware140_noc_77101bmx_noe_0100_firmwareModicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2019-6850
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.66%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:54
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module.

Action-Not Available
Vendor-n/a
Product-modicon_bmenoc_0321_firmwaremodicon_m580_firmwaremodicon_bmenoc_0321modicon_bmenoc_0311_firmwaremodicon_bmenoc_0311modicon_m580Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6836
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.28% / 50.95%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:14
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file.

Action-Not Available
Vendor-n/a
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0001_firmwaremeg6501-0002meg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Servers (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, and MEG6260-0415 - U.motion KNX Server Plus, Touch 1)
CWE ID-CWE-863
Incorrect Authorization
CVE-2015-0997
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5||MEDIUM
EPSS-0.60% / 68.51%
||
7 Day CHG~0.00%
Published-29 Mar, 2015 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack.

Action-Not Available
Vendor-n/aSchneider Electric SEAVEVA
Product-wonderware_intouch_2014aveva_edgen/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22749
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.36% / 57.11%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is sent to the web server of the module.

Action-Not Available
Vendor-n/a
Product-modicon_x80_bmxnor0200h_rtu_firmwaremodicon_x80_bmxnor0200h_rtuModicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22721
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.69%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:41
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to get limited knowledge of javascript code when crafted malicious parameters are submitted to the charging station web server.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22806
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.39% / 58.88%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)

Action-Not Available
Vendor-n/a
Product-fellerlynkwiser_for_knxspacelynkwiser_for_knx_firmwarefellerlynk_firmwarespacelynk_firmwarespaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)
CWE ID-CWE-669
Incorrect Resource Transfer Between Spheres
CVE-2021-22785
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.10%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists that could cause sensitive information of files located in the web root directory to leak when an attacker sends a HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions)

Action-Not Available
Vendor-n/a
Product-tsxp575634140noc78x00_firmware140noe771x1tsxety5103140cpu65150tsxp574634_firmwarebmxnoc0401_firmwaretsxp575634_firmwarebmxnoe0110_firmware140noe771x1_firmwaretsxp574634tsxp576634modicon_m340_bmxp342020bmxnoe0100_firmwaretsxety4103_firmwarebmxnoc0401tsxp576634_firmwarebmxnor0200h_rtumodicon_m340_bmxp342020_firmware140noc77101_firmwarebmxnoe0100140cpu65150_firmwarebmxnor0200h_rtu_firmwaretsxety4103140noc77101bmxnoe0110140noc78x00tsxety5103_firmwareModicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions)
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22774
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.14% / 34.07%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:45
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-759: Use of a One-Way Hash without a Salt vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could lead an attacker to get knowledge of charging station user account credentials using dictionary attacks techniques.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-916
Use of Password Hash With Insufficient Computational Effort
CVE-2021-22815
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.25% / 48.09%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22804
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.49% / 64.56%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22702
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.14% / 35.16%
||
7 Day CHG~0.00%
Published-19 Feb, 2021 | 15:13
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device.

Action-Not Available
Vendor-n/a
Product-powerlogic_ion8650powerlogic_ion7700_firmwarepowerlogic_ion8400_firmwarepowerlogic_pm8000_firmwarepowerlogic_pm8000powerlogic_ion8300_firmwarepowerlogic_ion7400_firmwarepowerlogic_ion7650_firmwarepowerlogic_ion7700powerlogic_ion8600powerlogic_ion8800powerlogic_ion8500_firmwarepowerlogic_ion8600_firmwarepowerlogic_ion8500powerlogic_ion8300powerlogic_ion9000_firmwarepowerlogic_ion7300_firmwarepowerlogic_ion9000powerlogic_ion8400powerlogic_ion7300powerlogic_ion8800_firmwarepowerlogic_ion7400powerlogic_ion7650powerlogic_ion8650_firmwarePowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2020-7541
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.31% / 53.84%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:52
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted request to the controller over HTTP.

Action-Not Available
Vendor-n/a
Product-140noc78100140cpu65150140noc78000_firmwaretsxp575634_firmware140noc78000bmxnoe0110_firmwaretsxp574634modicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmware140noc78100_firmwaremodicon_m340_bmxp342000modicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000140noe77111_firmwaremodicon_m340_bmxp342020_firmware140noc77101_firmwaremodicon_m340_bmxp3420102_firmware140noc77101bmxnoe0110tsxety5103_firmwaremodicon_m340_bmxp3420102cl_firmwaretsxety5103tsxp574634_firmwarebmxnoc0401_firmware140noe77111modicon_m340_bmxp3420302clmodicon_m340_bmxp3420302modicon_m340_bmxp342020bmxnoe0100_firmwaretsxp576634modicon_m340_bmxp341000_firmwaretsxety4103_firmwarebmxnoc0401tsxp576634_firmwaremodicon_m340_bmxp342000_firmwarebmxnoe0100140cpu65150_firmwaremodicon_m340_bmxp3420102tsxety4103tsxp575634Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
CWE ID-CWE-425
Direct Request ('Forced Browsing')
CVE-2020-7510
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.66%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:44
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow attacker to obtain private keys.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (Firmware version 1.5.2 and older)
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6849
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.66%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:53
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module.

Action-Not Available
Vendor-n/a
Product-modicon_bmenoc_0321_firmwaremodicon_m580_firmwaremodicon_bmenoc_0321modicon_bmenoc_0311_firmwaremodicon_bmenoc_0311modicon_m580Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2020-7565
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.3||HIGH
EPSS-0.02% / 4.84%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.

Action-Not Available
Vendor-n/a
Product-modicon_m221_firmwaremodicon_m221Modicon M221, all references, all versions
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2017-9635
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-3.9||LOW
EPSS-0.04% / 9.94%
||
7 Day CHG~0.00%
Published-18 May, 2018 | 13:00
Updated-17 Sep, 2024 | 03:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.

Action-Not Available
Vendor-
Product-ampla_manufacturing_execution_systemAmpla MES
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2017-7673
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-9.8||CRITICAL
EPSS-0.40% / 60.17%
||
7 Day CHG~0.00%
Published-14 Jul, 2017 | 15:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Apache OpenMeetings 1.0.0 uses not very strong cryptographic storage, captcha is not used in registration and forget password dialogs and auth forms missing brute force protection.

Action-Not Available
Vendor-The Apache Software Foundation
Product-openmeetingsApache OpenMeetings
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2017-7888
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.16% / 37.10%
||
7 Day CHG~0.00%
Published-10 May, 2017 | 14:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dolibarr ERP/CRM 4.0.4 stores passwords with the MD5 algorithm, which makes brute-force attacks easier.

Action-Not Available
Vendor-n/aDolibarr ERP & CRM
Product-dolibarr_erp\/crmn/a
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2024-54089
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.02% / 3.76%
||
7 Day CHG~0.00%
Published-11 Feb, 2025 | 10:29
Updated-12 Feb, 2025 | 15:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key. This could allow an attacker to guess or decrypt the password from the cyphertext.

Action-Not Available
Vendor-Siemens AG
Product-APOGEE PXC Series (P2 Ethernet)APOGEE PXC Series (BACnet)TALON TC Series (BACnet)
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2017-7903
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.23% / 45.82%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-1763-l16dwd_series_b1763-l16bwa_series_b1766-l32awaa_series_a1766-l32bwa_series_b1766-l32bwaa_series_b1763-l16bbb_series_b1766-l32bxb_series_a1766-l32bwa_series_a1766-l32awa_series_a1766-l32bwaa_series_a1763-l16bwa_series_a1763-l16awa_series_b1766-l32awaa_series_bab_micrologix_controller1766-l32bxb_series_b1766-l32awa_series_b1763-l16bbb_series_a1766-l32bxba_series_a1766-l32bxba_series_b1763-l16dwd_series_a1763-l16awa_series_aRockwell Automation Allen-Bradley MicroLogix 1100 and 1400
CWE ID-CWE-326
Inadequate Encryption Strength
CWE ID-CWE-521
Weak Password Requirements
CVE-2017-7905
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.20% / 41.74%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.

Action-Not Available
Vendor-gen/a
Product-multilin_sr_489_generator_protection_relay_firmwaremultilin_sr_469_motor_protection_relay_firmwaremultilin_sr_745_transformer_protection_relaymultilin_urplus_b95_firmwaremultilin_urplus_d90multilin_urplus_c90multilin_sr_750_feeder_protection_relay_firmwaremultilin_urplus_d90_firmwaremultilin_sr_760_feeder_protection_relay_firmwaremultilin_sr_369_motor_protection_relaymultilin_sr_760_feeder_protection_relaymultilin_sr_469_motor_protection_relaymultilin_sr_369_motor_protection_relay_firmwaremultilin_sr_750_feeder_protection_relaymultilin_universal_relay_firmwaremultilin_sr_745_transformer_protection_relay_firmwaremultilin_urplus_c90_firmwaremultilin_universal_relaymultilin_urplus_b95multilin_sr_489_generator_protection_relayGE Multilin SR, UR, and URplus Protective Relays
CWE ID-CWE-261
Weak Encoding for Password
CWE ID-CWE-326
Inadequate Encryption Strength
CWE ID-CWE-330
Use of Insufficiently Random Values
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2017-5999
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.16%
||
7 Day CHG~0.00%
Published-06 Mar, 2017 | 06:11
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in sysPass 2.x before 2.1, in which an algorithm was never sufficiently reviewed by cryptographers. The fact that inc/SP/Core/Crypt.class is using the MCRYPT_RIJNDAEL_256() function (the 256-bit block version of Rijndael, not AES) instead of MCRYPT_RIJNDAEL_128 (real AES) could help an attacker to create unknown havoc in the remote system.

Action-Not Available
Vendor-syspassn/a
Product-syspassn/a
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2017-2380
Matching Score-4
Assigner-Apple Inc.
ShareView Details
Matching Score-4
Assigner-Apple Inc.
CVSS Score-7.5||HIGH
EPSS-0.05% / 15.86%
||
7 Day CHG~0.00%
Published-02 Apr, 2017 | 01:36
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in certain Apple products. iOS before 10.3 is affected. The issue involves the Simple Certificate Enrollment Protocol (SCEP) implementation in the "Profiles" component. It allows remote attackers to bypass cryptographic protection mechanisms by leveraging DES support.

Action-Not Available
Vendor-n/aApple Inc.
Product-iphone_osn/a
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2013-4508
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-7.5||HIGH
EPSS-2.35% / 84.25%
||
7 Day CHG~0.00%
Published-08 Nov, 2013 | 02:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

lighttpd before 1.4.34, when SNI is enabled, configures weak SSL ciphers, which makes it easier for remote attackers to hijack sessions by inserting packets into the client-server data stream or obtain sensitive information by sniffing the network.

Action-Not Available
Vendor-lighttpdn/aDebian GNU/LinuxopenSUSE
Product-lighttpddebian_linuxopensusen/a
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2020-18220
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.07% / 21.69%
||
7 Day CHG~0.00%
Published-20 May, 2021 | 19:55
Updated-04 Aug, 2024 | 14:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Weak Encoding for Password in DoraCMS v2.1.1 and earlier allows attackers to obtain sensitive information as it does not use a random salt or IV for its AES-CBC encryption, causes password encrypted for users to be susceptible to dictionary attacks.

Action-Not Available
Vendor-html-jsn/a
Product-doracmsn/a
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2013-4104
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-7.5||HIGH
EPSS-0.14% / 34.53%
||
7 Day CHG~0.00%
Published-04 Nov, 2019 | 15:40
Updated-06 Aug, 2024 | 16:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cryptocat before 2.0.22 has weak encryption in the Socialist Millionnaire Protocol

Action-Not Available
Vendor-cryptocat_projectn/a
Product-cryptocatn/a
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2017-1695
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-5.9||MEDIUM
EPSS-0.16% / 37.20%
||
7 Day CHG~0.00%
Published-15 Feb, 2019 | 20:00
Updated-17 Sep, 2024 | 02:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM QRadar SIEM 7.2 and 7.3 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 134177.

Action-Not Available
Vendor-IBM Corporation
Product-qradar_security_information_and_event_managerQRadar SIEM
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2019-4339
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-5.9||MEDIUM
EPSS-0.15% / 35.79%
||
7 Day CHG~0.00%
Published-28 Oct, 2019 | 23:36
Updated-16 Sep, 2024 | 21:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Security Guardium Big Data Intelligence (SonarG) 4.0 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 161418.

Action-Not Available
Vendor-IBM Corporation
Product-security_guardium_big_data_intelligenceSecurity Guardium Big Data Intelligence
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2012-6707
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.14% / 34.27%
||
7 Day CHG~0.00%
Published-19 Oct, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

WordPress through 4.8.2 uses a weak MD5-based password hashing algorithm, which makes it easier for attackers to determine cleartext values by leveraging access to the hash values. NOTE: the approach to changing this may not be fully compatible with certain use cases, such as migration of a WordPress site from a web host that uses a recent PHP version to a different web host that uses PHP 5.2. These use cases are plausible (but very unlikely) based on statistics showing widespread deployment of WordPress with obsolete PHP versions.

Action-Not Available
Vendor-n/aWordPress.org
Product-wordpressn/a
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2017-17543
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-7.5||HIGH
EPSS-0.07% / 22.28%
||
7 Day CHG~0.00%
Published-26 Apr, 2018 | 20:00
Updated-25 Oct, 2024 | 14:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Users' VPN authentication credentials are unsafely encrypted in Fortinet FortiClient for Windows 5.6.0 and below versions, FortiClient for Mac OSX 5.6.0 and below versions and FortiClient SSLVPN Client for Linux 4.4.2335 and below versions, due to the use of a static encryption key and weak encryption algorithms.

Action-Not Available
Vendor-Fortinet, Inc.
Product-forticlientforticlient_sslvpn_clientFortiClient SSLVPN Client for LinuxFortiClient for WindowsFortiClient for Mac OSX
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2021-38925
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-5.9||MEDIUM
EPSS-0.11% / 30.34%
||
7 Day CHG~0.00%
Published-06 Oct, 2021 | 17:10
Updated-16 Sep, 2024 | 21:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Sterling B2B Integrator Standard Edition 5.2.0. 0 through 6.1.1.0 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 210171.

Action-Not Available
Vendor-IBM Corporation
Product-sterling_b2b_integratorSterling B2B Integrator
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2017-1473
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-7.5||HIGH
EPSS-0.11% / 30.34%
||
7 Day CHG~0.00%
Published-23 Apr, 2018 | 13:00
Updated-16 Sep, 2024 | 22:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Security Access Manager Appliance 8.0.0 through 8.0.1.6 and 9.0.0 through 9.0.3.1 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 128605.

Action-Not Available
Vendor-IBM Corporation
Product-security_access_manager_for_web_appliancesecurity_access_manager_appliancesecurity_access_manager_firmwaresecurity_access_manager_for_mobile_appliancesecurity_access_manager_for_web_firmwaresecurity_access_manager_for_mobileSecurity Access Manager
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2021-38983
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-4.4||MEDIUM
EPSS-0.10% / 28.71%
||
7 Day CHG~0.00%
Published-15 Nov, 2021 | 15:35
Updated-16 Sep, 2024 | 16:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Tivoli Key Lifecycle Manager 3.0, 3.0.1, 4.0, and 4.1 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 212792.

Action-Not Available
Vendor-IBM CorporationLinux Kernel Organization, IncMicrosoft Corporation
Product-linux_kernelsecurity_guardium_key_lifecycle_managerwindowssecurity_key_lifecycle_manageraixSecurity Key Lifecycle Manager
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2021-39182
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.5||HIGH
EPSS-0.08% / 24.18%
||
7 Day CHG~0.00%
Published-08 Nov, 2021 | 14:15
Updated-04 Aug, 2024 | 01:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Use of Password Hash With Insufficient Computational Effort and Use of a Broken or Risky Cryptographic Algorithm and Reversible One-Way Hash in hashing.py

EnroCrypt is a Python module for encryption and hashing. Prior to version 1.1.4, EnroCrypt used the MD5 hashing algorithm in the hashing file. Beginners who are unfamiliar with hashes can face problems as MD5 is considered an insecure hashing algorithm. The vulnerability is patched in v1.1.4 of the product. As a workaround, users can remove the `MD5` hashing function from the file `hashing.py`.

Action-Not Available
Vendor-enrocrypt_projectMorgan-Phoenix
Product-enrocryptEnroCrypt
CWE ID-CWE-916
Use of Password Hash With Insufficient Computational Effort
CWE ID-CWE-328
Use of Weak Hash
CWE ID-CWE-327
Use of a Broken or Risky Cryptographic Algorithm
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2019-4557
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-5.9||MEDIUM
EPSS-0.13% / 33.78%
||
7 Day CHG~0.00%
Published-25 Feb, 2020 | 13:55
Updated-16 Sep, 2024 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Qradar Advisor 1.1 through 2.5 with Watson uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 166206.

Action-Not Available
Vendor-IBM Corporation
Product-qradar_advisorQradar Advisor
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2021-38984
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-3.7||LOW
EPSS-0.10% / 27.85%
||
7 Day CHG~0.00%
Published-15 Nov, 2021 | 15:35
Updated-16 Sep, 2024 | 21:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Tivoli Key Lifecycle Manager 3.0, 3.0.1, 4.0, and 4.1 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 212793.

Action-Not Available
Vendor-IBM Corporation
Product-security_key_lifecycle_managersecurity_guardium_key_lifecycle_managerSecurity Key Lifecycle Manager
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2021-38862
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-5.9||MEDIUM
EPSS-0.11% / 30.34%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 18:55
Updated-16 Sep, 2024 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Data Risk Manager (iDNA) 2.0.6 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 207980.

Action-Not Available
Vendor-IBM Corporation
Product-data_risk_managerData Risk Manager
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2024-39928
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-7.5||HIGH
EPSS-0.20% / 42.25%
||
7 Day CHG~0.00%
Published-24 Sep, 2024 | 07:27
Updated-16 May, 2025 | 20:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Apache Linkis Spark EngineConn: Commons Lang's RandomStringUtils Random string security vulnerability

In Apache Linkis <= 1.5.0, a Random string security vulnerability in Spark EngineConn, random string generated by the Token when starting Py4j uses the Commons Lang's RandomStringUtils. Users are recommended to upgrade to version 1.6.0, which fixes this issue.

Action-Not Available
Vendor-apache_software_foundationThe Apache Software Foundation
Product-linkisApache Linkis Spark EngineConnapache_linkis_spark_engineconn
CWE ID-CWE-326
Inadequate Encryption Strength
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • Next
Details not found