A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:12 Jul, 2022 | 10:06
Updated At:03 Aug, 2024 | 08:01
Rejected At:
â–¼CVE Numbering Authority (CNA)

A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.

Affected Products
Vendor
Siemens AGSiemens
Product
SIMATIC MV540 H
Versions
Affected
  • All versions < V3.3
Vendor
Siemens AGSiemens
Product
SIMATIC MV540 S
Versions
Affected
  • All versions < V3.3
Vendor
Siemens AGSiemens
Product
SIMATIC MV550 H
Versions
Affected
  • All versions < V3.3
Vendor
Siemens AGSiemens
Product
SIMATIC MV550 S
Versions
Affected
  • All versions < V3.3
Vendor
Siemens AGSiemens
Product
SIMATIC MV560 U
Versions
Affected
  • All versions < V3.3
Vendor
Siemens AGSiemens
Product
SIMATIC MV560 X
Versions
Affected
  • All versions < V3.3
Problem Types
TypeCWE IDDescription
CWECWE-306CWE-306: Missing Authentication for Critical Function
Type: CWE
CWE ID: CWE-306
Description: CWE-306: Missing Authentication for Critical Function
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf
Resource:
x_refsource_MISC
â–¼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:12 Jul, 2022 | 10:15
Updated At:15 Jul, 2022 | 17:31

A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary2.05.0MEDIUM
AV:N/AC:L/Au:N/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Type: Primary
Version: 2.0
Base score: 5.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:N/C:P/I:N/A:N
CPE Matches

Siemens AG
siemens
>>simatic_mv540_h_firmware>>Versions before 3.3(exclusive)
cpe:2.3:o:siemens:simatic_mv540_h_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_mv540_h>>-
cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_mv540_s_firmware>>Versions before 3.3(exclusive)
cpe:2.3:o:siemens:simatic_mv540_s_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_mv540_s>>-
cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_mv550_h_firmware>>Versions before 3.3(exclusive)
cpe:2.3:o:siemens:simatic_mv550_h_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_mv550_h>>-
cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_mv550_s_firmware>>Versions before 3.3(exclusive)
cpe:2.3:o:siemens:simatic_mv550_s_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_mv550_s>>-
cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_mv560_u_firmware>>Versions before 3.3(exclusive)
cpe:2.3:o:siemens:simatic_mv560_u_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_mv560_u>>-
cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_mv560_x_firmware>>Versions before 3.3(exclusive)
cpe:2.3:o:siemens:simatic_mv560_x_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_mv560_x>>-
cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-306Primarynvd@nist.gov
CWE-306Secondaryproductcert@siemens.com
CWE ID: CWE-306
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-306
Type: Secondary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdfproductcert@siemens.com
Patch
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf
Source: productcert@siemens.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

523Records found

CVE-2023-46601
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.6||CRITICAL
EPSS-0.52% / 41.15%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 11:04
Updated-08 Jan, 2025 | 16:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in COMOS (All versions). The affected application lacks proper access controls in making the SQLServer connection. This could allow an attacker to query the database directly to access information that the user should not have access to.

Action-Not Available
Vendor-Siemens AG
Product-comosCOMOS
CWE ID-CWE-284
Improper Access Control
CVE-2017-9947
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-7.28% / 93.70%
||
7 Day CHG~0.00%
Published-23 Oct, 2017 | 00:00
Updated-02 Jun, 2026 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server (80/tcp and 443/tcp) to obtain information on the structure of the file system of the affected devices.

Action-Not Available
Vendor-n/aSiemens AG
Product-talon_tc_modular_firmwareapogee_pxc_modular_firmwaretalon_tc_compactapogee_pxcapogee_pxc_modulartalon_tc_modulartalon_tc_compact_firmwareapogee_pxc_firmwareAPOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CWE ID-CWE-538
Insertion of Sensitive Information into Externally-Accessible File or Directory
CVE-2025-40744
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.21% / 10.96%
||
7 Day CHG~0.00%
Published-11 Nov, 2025 | 20:20
Updated-12 Nov, 2025 | 20:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 11). Affected applications do not properly validate client certificates to connect to License Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.

Action-Not Available
Vendor-Siemens AG
Product-Solid Edge SE2025
CWE ID-CWE-295
Improper Certificate Validation
CVE-2022-42733
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.62% / 46.31%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 00:00
Updated-29 Apr, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool.

Action-Not Available
Vendor-Siemens AG
Product-syngo_dynamics_cardiovascular_imaging_and_information_systemsyngo Dynamics
CWE ID-CWE-73
External Control of File Name or Path
CWE ID-CWE-610
Externally Controlled Reference to a Resource in Another Sphere
CVE-2022-42894
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.58% / 44.09%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 00:00
Updated-30 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). An unauthenticated Server-Side Request Forgery (SSRF) vulnerability was identified in one of the web services exposed on the syngo Dynamics application that could allow for the leaking of NTLM credentials as well as local service enumeration.

Action-Not Available
Vendor-Siemens AG
Product-syngo_dynamics_cardiovascular_imaging_and_information_systemsyngo Dynamics
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)
CVE-2022-42732
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.62% / 46.31%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 00:00
Updated-29 Apr, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool.

Action-Not Available
Vendor-Siemens AG
Product-syngo_dynamics_cardiovascular_imaging_and_information_systemsyngo Dynamics
CWE ID-CWE-73
External Control of File Name or Path
CWE ID-CWE-610
Externally Controlled Reference to a Resource in Another Sphere
CVE-2019-6576
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-1.74% / 75.31%
||
7 Day CHG~0.00%
Published-14 May, 2019 | 19:54
Updated-02 Jun, 2026 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_hmi_ktp_mobile_panels_ktp700f_firmwaresimatic_hmi_tp_firmwaresimatic_hmi_mpsimatic_hmi_comfort_outdoor_panelssimatic_hmi_ktp_mobile_panels_ktp400f_firmwaresimatic_hmi_ktp_mobile_panels_ktp700_firmwaresimatic_hmi_comfort_panels_firmwaresimatic_hmi_ktp_mobile_panels_ktp900f_firmwaresimatic_hmi_ktp_mobile_panels_ktp900simatic_hmi_mp_firmwaresimatic_wincc_\(tia_portal\)simatic_hmi_comfort_panelssimatic_hmi_tpsimatic_hmi_ktp_mobile_panels_ktp700fsimatic_hmi_ktp_mobile_panels_ktp700simatic_hmi_ktp_mobile_panels_ktp900fsimatic_hmi_opsimatic_hmi_comfort_outdoor_panels_firmwaresimatic_wincc_runtimesimatic_hmi_ktp_mobile_panels_ktp900_firmwaresimatic_hmi_ktp_mobile_panels_ktp400fsimatic_hmi_op_firmwareSIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)SIMATIC WinCC Runtime AdvancedSIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900FSIMATIC WinCC (TIA Portal)SIMATIC WinCC Runtime ProfessionalSIMATIC HMI Comfort Outdoor Panels 7" & 15"SIMATIC HMI Comfort Panels 4" - 22"
CVE-2019-18287
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 72.97%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The Application Server exposes directory listings and files containing sensitive information. This vulnerability is independent from CVE-2019-18286. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2012-3030
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5||MEDIUM
EPSS-2.64% / 83.97%
||
7 Day CHG~0.00%
Published-18 Sep, 2012 | 14:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccsimatic_pcs7n/a
CVE-2019-18333
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-1.03% / 60.01%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to filenames on the server by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-6119
Matching Score-8
Assigner-OpenSSL Software Foundation
ShareView Details
Matching Score-8
Assigner-OpenSSL Software Foundation
CVSS Score-7.5||HIGH
EPSS-66.58% / 99.21%
||
7 Day CHG~0.00%
Published-03 Sep, 2024 | 15:58
Updated-14 Jul, 2026 | 12:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Possible denial of service in X.509 name checks

Issue summary: Applications performing certificate name checks (e.g., TLS clients checking server certificates) may attempt to read an invalid memory address resulting in abnormal termination of the application process. Impact summary: Abnormal termination of an application can a cause a denial of service. Applications performing certificate name checks (e.g., TLS clients checking server certificates) may attempt to read an invalid memory address when comparing the expected name with an `otherName` subject alternative name of an X.509 certificate. This may result in an exception that terminates the application program. Note that basic certificate chain validation (signatures, dates, ...) is not affected, the denial of service can occur only when the application also specifies an expected DNS name, Email address or IP address. TLS servers rarely solicit client certificates, and even when they do, they generally don't perform a name check against a reference identifier (expected identity), but rather extract the presented identity after checking the certificate chain. So TLS servers are generally not affected and the severity of the issue is Moderate. The FIPS modules in 3.3, 3.2, 3.1 and 3.0 are not affected by this issue.

Action-Not Available
Vendor-NetApp, Inc.Siemens AGOpenSSL
Product-h410c_firmwareh615c_firmwareontap_select_deploy_administration_utilityh610sc250h615ch300sh500sbootstrap_osbrocade_fabric_operating_systemmanagement_services_for_element_software_and_netapp_hcia250_firmwarea250h410ch700s_firmwareh300s_firmware500factive_iq_unified_manager500f_firmwareh500s_firmwareh610s_firmwareh610c_firmwarehci_compute_nodeh410s_firmwarec250_firmwareh610ch410sontap_toolsh700sopensslontap_9OpenSSLRUGGEDCOM RST2428PSCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 familySIPLUS S7-1500 CPU 1518-4 PN/DP MFPSIMATIC S7-1500 CPU 1518-4 PN/DP MFPSIMATIC S7-1500 CPU 1518F-4 PN/DP MFPopensslSCALANCE XCM-/XRM-/XCH-/XRH-300 family
CWE ID-CWE-843
Access of Resource Using Incompatible Type ('Type Confusion')
CVE-2019-12265
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-55.27% / 98.93%
||
7 Day CHG~0.00%
Published-09 Aug, 2019 | 18:14
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wind River VxWorks 6.5, 6.6, 6.7, 6.8, 6.9.3 and 6.9.4 has a Memory Leak in the IGMPv3 client component. There is an IPNET security vulnerability: IGMP Information leak via IGMPv3 specific membership report.

Action-Not Available
Vendor-windriverbeldenn/aNetApp, Inc.Siemens AGSonicWall Inc.
Product-power_meter_9810_firmwarehirschmann_rsp20ruggedcom_win7025_firmwarehirschmann_ees25sonicoshirschmann_grs1030hirschmann_grs1142ruggedcom_win7018_firmwarehirschmann_rspe32hirschmann_grs1130garrettcom_magnum_dx940ehirschmann_rspe35hirschmann_eesx20hirschmann_rspe37ruggedcom_win7018power_meter_9410_firmwarehirschmann_grs1042siprotec_5_firmwareruggedcom_win7000ruggedcom_win7200hirschmann_rsp35garrettcom_magnum_dx940e_firmwaree-series_santricity_os_controllervxworkshirschmann_msp40hirschmann_octopus_os3hirschmann_rsp30hirschmann_dragon_mach4000hirschmann_dragon_mach4500hirschmann_msp32hirschmann_rsp25hirschmann_rail_switch_power_smarthirschmann_eesx30hirschmann_grs1020hirschmann_rail_switch_power_litehirschmann_eagle20hirschmann_eagle30hirschmann_hiosruggedcom_win7025hirschmann_rspe30hirschmann_eagle_oneruggedcom_win7200_firmwaresiprotec_5hirschmann_ees20hirschmann_red25power_meter_9410power_meter_9810ruggedcom_win7000_firmwarehirschmann_msp30hirschmann_grs1120n/a
CWE ID-CWE-401
Missing Release of Memory after Effective Lifetime
CVE-2017-9946
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-24.81% / 97.67%
||
7 Day CHG~0.00%
Published-23 Oct, 2017 | 00:00
Updated-02 Jun, 2026 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device.

Action-Not Available
Vendor-n/aSiemens AG
Product-talon_tc_modular_firmwareapogee_pxc_modular_firmwaretalon_tc_compactapogee_pxcapogee_pxc_modulartalon_tc_modulartalon_tc_compact_firmwareapogee_pxc_firmwareAPOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5
CWE ID-CWE-287
Improper Authentication
CVE-2024-54089
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.19% / 9.50%
||
7 Day CHG~0.00%
Published-11 Feb, 2025 | 10:29
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key. This could allow an attacker to guess or decrypt the password from the cyphertext.

Action-Not Available
Vendor-Siemens AG
Product-APOGEE PXC Series (P2 Ethernet)APOGEE PXC Series (BACnet)TALON TC Series (BACnet)
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2019-10921
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-2.45% / 82.66%
||
7 Day CHG~0.00%
Published-14 May, 2019 | 19:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known

Action-Not Available
Vendor-Siemens AG
Product-logo\!8_bm_firmwarelogo\!8_bmLOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-256
Plaintext Storage of a Password
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2016-5744
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-4.40% / 90.31%
||
7 Day CHG~0.00%
Published-22 Jul, 2016 | 15:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_winccn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-54015
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.56% / 43.43%
||
7 Day CHG~0.00%
Published-11 Feb, 2025 | 10:28
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials.

Action-Not Available
Vendor-Siemens AG
Product-SIPROTEC 5 7SA82 (CP150)SIPROTEC 5 7SL86 (CP300)SIPROTEC 5 7UM85 (CP300)SIPROTEC 5 7SS85 (CP300)SIPROTEC 5 7UT87 (CP300)SIPROTEC 5 7SY82 (CP150)SIPROTEC 5 7SJ82 (CP150)SIPROTEC 5 7VK87 (CP300)SIPROTEC 5 7ST86 (CP300)SIPROTEC 5 Compact 7SX800 (CP050)SIPROTEC 5 Communication Module ETH-BD-2FO V9.8SIPROTEC 5 6MD85 (CP300)SIPROTEC 5 7SD87 (CP300)SIPROTEC 5 7ST85 (CP300) V9.6xSIPROTEC 5 7SK85 (CP300)SIPROTEC 5 Communication Module ETH-BD-2FO V9.6SIPROTEC 5 7ST86 (CP300) V9.8xSIPROTEC 5 7UT86 (CP300)SIPROTEC 5 6MD86 (CP300)SIPROTEC 5 7KE85 (CP300)SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2)SIPROTEC 5 7SJ85 (CP300)SIPROTEC 5 6MU85 (CP300)SIPROTEC 5 7SD82 (CP150)SIPROTEC 5 7SD86 (CP300)SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8SIPROTEC 5 7SX82 (CP150)SIPROTEC 5 7VE85 (CP300)SIPROTEC 5 7UT82 (CP150)SIPROTEC 5 7SJ81 (CP150)SIPROTEC 5 6MD89 (CP300)SIPROTEC 5 7SL87 (CP300)SIPROTEC 5 7SJ86 (CP300)SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6SIPROTEC 5 7SA86 (CP300)SIPROTEC 5 7SX85 (CP300)SIPROTEC 5 Communication Module ETH-BD-2FOSIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2)SIPROTEC 5 6MD89 (CP300) V9.6xSIPROTEC 5 7SA87 (CP300)SIPROTEC 5 7SL82 (CP150)SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6SIPROTEC 5 6MD84 (CP300)SIPROTEC 5 7SK82 (CP150)SIPROTEC 5 7UT85 (CP300)SIPROTEC 5 7ST85 (CP300)SIPROTEC 5 7VU85 (CP300)
CWE ID-CWE-1392
Use of Default Credentials
CVE-2016-4785
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-2.68% / 84.23%
||
7 Day CHG~0.00%
Published-31 May, 2016 | 01:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.

Action-Not Available
Vendor-n/aSiemens AG
Product-siprotec_4_en100siprotec_firmwaresiprotec_compact_model_7sk81siprotec_compact_model_7rw80siprotec_compact_model_7sd80siprotec_compact_model_7sj81siprotec_compact_model_7sk80siprotec_compact_model_7sj80siprotec_compact_modeln/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2017-0147
Matching Score-8
Assigner-Microsoft Corporation
ShareView Details
Matching Score-8
Assigner-Microsoft Corporation
CVSS Score-7.5||HIGH
EPSS-99.69% / 99.95%
||
7 Day CHG~0.00%
Published-17 Mar, 2017 | 00:00
Updated-22 Apr, 2026 | 13:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-06-14||Apply updates per vendor instructions.

The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to obtain sensitive information from process memory via a crafted packets, aka "Windows SMB Information Disclosure Vulnerability."

Action-Not Available
Vendor-Siemens AGMicrosoft Corporation
Product-windows_7windows_8.1windows_10_1511tissue_preparation_system_firmwarewindows_vistaversant_kpcr_molecular_systemversant_kpcr_sample_prepsyngo_sc2000acuson_p500_firmwareversant_kpcr_molecular_system_firmwareacuson_x700_firmwarewindows_server_2012tissue_preparation_systemversant_kpcr_sample_prep_firmwareacuson_p300windows_server_2008acuson_p300_firmwarewindows_10_1607syngo_sc2000_firmwareacuson_sc2000acuson_x700acuson_p500acuson_sc2000_firmwarewindows_10_1507windows_server_2016windows_rt_8.1Windows SMBSMBv1 server
CVE-2022-34659
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-0.55% / 42.89%
||
7 Day CHG~0.00%
Published-10 Aug, 2022 | 11:17
Updated-14 Jul, 2026 | 10:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_star-ccm\+_viewerSimcenter STAR-CCM+
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-32253
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.9||MEDIUM
EPSS-0.57% / 43.82%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-03 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). Due to improper input validation, the OpenSSL certificate's password could be printed to a file reachable by an attacker.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-20
Improper Input Validation
CVE-2016-9154
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-1.50% / 71.60%
||
7 Day CHG~0.00%
Published-23 Dec, 2016 | 05:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2 for Desigo PX automation controllers PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D (All firmware versions < V6.00.046) and Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2 for Desigo PX automation controllers PXC00-U, PXC64-U, PXC128-U (All firmware versions < V6.00.046) use a pseudo random number generator with insufficient entropy to generate certificates for HTTPS, potentially allowing remote attackers to reconstruct the corresponding private key.

Action-Not Available
Vendor-n/aSiemens AG
Product-desigo_web_module_pxa40-w1desigo_web_module_pxa30-w0desigo_web_module_pxa30-w2_firmwaredesigo_web_module_pxa40-w2_firmwaredesigo_web_module_pxa30-w0_firmwaredesigo_web_module_pxa40-w0desigo_web_module_pxa30-w1desigo_web_module_pxa40-w2desigo_web_module_pxa30-w2desigo_web_module_pxa40-w0_firmwaredesigo_web_module_pxa40-w1_firmwaredesigo_web_module_pxa30-w1_firmwareDesigo PX Web modules with all firmware versions < V6.00.046
CWE ID-CWE-332
Insufficient Entropy in PRNG
CVE-2016-9155
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.33% / 81.77%
||
7 Day CHG~0.00%
Published-22 Nov, 2016 | 11:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The following SIEMENS branded IP Camera Models CCMW3025, CVMW3025-IR, CFMW3025 prior to version 1.41_SP18_S1; CCPW3025, CCPW5025 prior to version 0.1.73_S1; CCMD3025-DN18 prior to version v1.394_S1; CCID1445-DN18, CCID1445-DN28, CCID1145-DN36, CFIS1425, CCIS1425, CFMS2025, CCMS2025, CVMS2025-IR, CFMW1025, CCMW1025 prior to version v2635_SP1 could allow an attacker with network access to the web server to obtain administrative credentials under certain circumstances.

Action-Not Available
Vendor-n/aSiemens AG
Product-ccis1425_firmwarecvmw3025-ir_firmwareccid1445-dn28cfmw1025_firmwareccpw3025ccms2025_firmwarecfmw1025cfmw3025ccid1445-dn36ccmw1025ccpw3025_firmwarecfmw3025_firmwareccid1445-dn18_firmwareccms2025ccmw1025_firmwareccid1445-dn28_firmwarecvmw3025-ircfms2025ccid1445-dn36_firmwarecvms2025-ir_firmwareccis1425cfis1425_firmwareccmw3025ccmd3025-dn18_firmwareccid1445-dn18ccmw3025_firmwarecfis1425ccmd3025-dn18cfms2025_firmwarecvms2025-irSIEMENS-branded IP Cameras
CWE ID-CWE-284
Improper Access Control
CVE-2016-8672
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-1.85% / 76.93%
||
7 Day CHG~0.00%
Published-23 Nov, 2016 | 11:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server delivers cookies without the "secure" flag. Modern browsers interpreting the flag would mitigate potential data leakage in case of clear text transmission.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_cp_443-1simatic_cp_343-1simatic_s7_300_cpusimatic_cp_443-1_firmwaresimatic_s7_300_cpu_firmwaresimatic_cp_343-1_firmwaresimatic_s7_400_cpu_firmwaresimatic_s7_400_cpun/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-49997
Matching Score-8
Assigner-kernel.org
ShareView Details
Matching Score-8
Assigner-kernel.org
CVSS Score-7.5||HIGH
EPSS-1.09% / 61.86%
||
7 Day CHG~0.00%
Published-21 Oct, 2024 | 18:02
Updated-12 May, 2026 | 12:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
net: ethernet: lantiq_etop: fix memory disclosure

In the Linux kernel, the following vulnerability has been resolved: net: ethernet: lantiq_etop: fix memory disclosure When applying padding, the buffer is not zeroed, which results in memory disclosure. The mentioned data is observed on the wire. This patch uses skb_put_padto() to pad Ethernet frames properly. The mentioned function zeroes the expanded buffer. In case the packet cannot be padded it is silently dropped. Statistics are also not incremented. This driver does not support statistics in the old 32-bit format or the new 64-bit format. These will be added in the future. In its current form, the patch should be easily backported to stable versions. Ethernet MACs on Amazon-SE and Danube cannot do padding of the packets in hardware, so software padding must be applied.

Action-Not Available
Vendor-Siemens AGLinux Kernel Organization, Inc
Product-linux_kernelLinuxSIPLUS S7-1500 CPU 1518-4 PN/DP MFPRUGGEDCOM RST2428PSIMATIC S7-1500 CPU 1518F-4 PN/DP MFPSIMATIC S7-1500 CPU 1518-4 PN/DP MFPSCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 familySCALANCE XCM-/XRM-/XCH-/XRH-300 familySIMATIC S7-1500 TM MFP - GNU/Linux subsystem
CWE ID-CWE-212
Improper Removal of Sensitive Information Before Storage or Transfer
CVE-2024-50310
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.47% / 38.11%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 12:49
Updated-13 Nov, 2024 | 23:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC CP 1543-1 V4.0 (6GK7543-1AX10-0XE0) (All versions >= V4.0.44 < V4.0.50). Affected devices do not properly handle authorization. This could allow an unauthenticated remote attacker to gain access to the filesystem.

Action-Not Available
Vendor-Siemens AG
Product-simatic_cp_1543-1simatic_cp_1543-1_firmwareSIMATIC CP 1543-1 V4.0simatic_cp_1543-1
CWE ID-CWE-863
Incorrect Authorization
CVE-2022-32285
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.95% / 57.70%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-03 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix SAML Module (Mendix 7 compatible) (All versions < V1.16.6), Mendix SAML Module (Mendix 8 compatible) (All versions < V2.2.2), Mendix SAML Module (Mendix 9 compatible) (All versions < V3.2.3). The affected module is vulnerable to XML External Entity (XXE) attacks due to insufficient input sanitation. This may allow an attacker to disclose confidential data under certain circumstances.

Action-Not Available
Vendor-mendixSiemens AG
Product-samlMendix SAML Module (Mendix 8 compatible)Mendix SAML Module (Mendix 7 compatible)Mendix SAML Module (Mendix 9 compatible)
CWE ID-CWE-611
Improper Restriction of XML External Entity Reference
CVE-2022-32258
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.83% / 53.74%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-03 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains an older feature that allows to import device configurations via a specific endpoint. An attacker could use this vulnerability for information disclosure.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-448
Obsolete Feature in UI
CVE-2016-4784
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-2.68% / 84.23%
||
7 Day CHG~0.00%
Published-31 May, 2016 | 01:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.

Action-Not Available
Vendor-n/aSiemens AG
Product-siprotec_4_en100siprotec_compact_model_7sk81siprotec_compact_model_7rw80siprotec_compact_model_7sd80siprotec_compact_model_en100siprotec_compact_model_7sk80siprotec_compact_model_7sj81siprotec_firmwaresiprotec_compact_model_7sj80n/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-32254
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.79% / 52.41%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-03 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-532
Insertion of Sensitive Information into Log File
CVE-2017-12737
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-1.74% / 75.42%
||
7 Day CHG~0.00%
Published-15 Nov, 2017 | 08:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the network.

Action-Not Available
Vendor-n/aSiemens AG
Product-sm-2556sm-2556_firmwareSiemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-16417
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-3.35% / 87.40%
||
7 Day CHG~0.00%
Published-30 Oct, 2019 | 16:26
Updated-05 Aug, 2024 | 10:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-w1750d_firmwareinstantw1750dn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-15473
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5.9||MEDIUM
EPSS-98.63% / 99.92%
||
7 Day CHG~0.00%
Published-17 Aug, 2018 | 00:00
Updated-17 Dec, 2025 | 22:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

OpenSSH through 7.7 is prone to a user enumeration vulnerability due to not delaying bailout for an invalid authenticating user until after the packet containing the request has been fully parsed, related to auth2-gss.c, auth2-hostbased.c, and auth2-pubkey.c.

Action-Not Available
Vendor-n/aDebian GNU/LinuxSiemens AGOracle CorporationRed Hat, Inc.NetApp, Inc.OpenBSDCanonical Ltd.
Product-debian_linuxoncommand_unified_manageraff_baseboard_management_controllercloud_backupvasa_providercn1610_firmwareservice_processoropensshsun_zfs_storage_appliance_kitenterprise_linux_workstationfas_baseboard_management_controllerscalance_x204rna_firmwareclustered_data_ontapontap_select_deployvirtual_storage_consoleenterprise_linux_desktopubuntu_linuxdata_ontapenterprise_linux_serverdata_ontap_edgesteelstore_cloud_integrated_storagecn1610scalance_x204rnastorage_replication_adaptern/a
CWE ID-CWE-362
Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
CVE-2024-41904
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.54% / 42.16%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 07:54
Updated-14 Aug, 2024 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not properly enforce restriction of excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys.

Action-Not Available
Vendor-Siemens AG
Product-sinec_traffic_analyzerSINEC Traffic Analyzersinec_traffic_analyzer
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2018-13812
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-3.57% / 88.16%
||
7 Day CHG~0.00%
Published-13 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 09:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_hmi_ktp_mobile_panels_ktp700fsimatic_hmi_ktp_mobile_panels_ktp900_firmwaresimatic_hmi_tpsimatic_hmi_ktp_mobile_panels_ktp900fsimatic_hmi_tp_firmwaresimatic_hmi_ktp_mobile_panels_ktp400fsimatic_hmi_comfort_outdoor_panelssimatic_hmi_comfort_outdoor_panels_firmwaresimatic_wincc_\(tia_portal\)simatic_hmi_ktp_mobile_panels_ktp700simatic_hmi_ktp_mobile_panels_ktp700f_firmwaresimatic_wincc_runtimesimatic_hmi_op_firmwaresimatic_hmi_mp_firmwaresimatic_hmi_ktp_mobile_panels_ktp900f_firmwaresimatic_hmi_ktp_mobile_panels_ktp400f_firmwaresimatic_hmi_opsimatic_hmi_ktp_mobile_panels_ktp900simatic_hmi_comfort_panelssimatic_hmi_comfort_panels_firmwaresimatic_hmi_mpsimatic_hmi_ktp_mobile_panels_ktp700_firmwareSIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2015-1357
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-1.05% / 60.80%
||
7 Day CHG~0.00%
Published-02 Feb, 2015 | 15:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allow context-dependent attackers to discover password hashes by reading (1) files or (2) security logs.

Action-Not Available
Vendor-n/aSiemens AG
Product-ruggedcom_win5100ruggedcom_win7000ruggedcom_win5200ruggedcom_firmwareruggedcom_win7200n/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2015-1358
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-2.69% / 84.33%
||
7 Day CHG~0.00%
Published-18 Feb, 2015 | 02:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to determine cleartext credentials by sniffing the network and conducting a decryption attack.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccn/a
CVE-2022-27241
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-1.33% / 68.13%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:08
Updated-03 Aug, 2024 | 05:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information.

Action-Not Available
Vendor-mendixSiemens AG
Product-mendixMendix Applications using Mendix 7Mendix Applications using Mendix 9 (V9.6)Mendix Applications using Mendix 8Mendix Applications using Mendix 9
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-27480
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-2.45% / 82.65%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:08
Updated-03 Aug, 2024 | 05:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM A8000 CP-8031 (All versions < V4.80), SICAM A8000 CP-8050 (All versions < V4.80). Affected devices do not require an user to be authenticated to access certain files. This could allow unauthenticated attackers to download these files.

Action-Not Available
Vendor-Siemens AG
Product-sicam_a8000_cp-8031sicam_a8000_cp-8050sicam_a8000_cp-8031_firmwaresicam_a8000_cp-8050_firmwareSICAM A8000 CP-8050SICAM A8000 CP-8031
CWE ID-CWE-862
Missing Authorization
CWE ID-CWE-425
Direct Request ('Forced Browsing')
CVE-2014-8552
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-2.05% / 79.21%
||
7 Day CHG~0.00%
Published-26 Nov, 2014 | 11:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_winccsimatic_pcs7simatic_tiaportalsimatic_pcs_7n/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-24044
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.84% / 54.21%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:46
Updated-03 Aug, 2024 | 03:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The login functionality of the application does not employ any countermeasures against Password Spraying attacks or Credential Stuffing attacks. An attacker could obtain a list of valid usernames on the device by exploiting the issue and then perform a precise Password Spraying or Credential Stuffing attack in order to obtain access to at least one account.

Action-Not Available
Vendor-Siemens AG
Product-desigo_dxr2desigo_pxc3_firmwaredesigo_pxc4desigo_dxr2_firmwaredesigo_pxc5_firmwaredesigo_pxc4_firmwaredesigo_pxc3desigo_pxc5Desigo PXC5Desigo PXC3Desigo DXR2Desigo PXC4
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2024-41792
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.2||CRITICAL
EPSS-0.57% / 43.63%
||
7 Day CHG~0.00%
Published-08 Apr, 2025 | 08:22
Updated-23 Sep, 2025 | 16:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices contains a path traversal vulnerability. This could allow an unauthenticated attacker it to access arbitrary files on the device with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-7kt_pac1260_data_manager7kt_pac1260_data_manager_firmwareSENTRON 7KT PAC1260 Data Manager
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-35210
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.1||MEDIUM
EPSS-0.15% / 4.58%
||
7 Day CHG~0.00%
Published-11 Jun, 2024 | 11:15
Updated-11 Feb, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server is not enforcing HSTS. This could allow an attacker to perform downgrade attacks exposing confidential information.

Action-Not Available
Vendor-Siemens AG
Product-sinec_traffic_analyzerSINEC Traffic Analyzersinec_traffic_analyzer
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2024-39888
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.24% / 15.69%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix Encryption (All versions >= V10.0.0 < V10.0.2). Affected versions of the module define a specific hard-coded default value for the EncryptionKey constant, which is used in projects where no individual EncryptionKey was specified. This could allow to an attacker to decrypt any encrypted project data, as the default encryption key can be considered compromised.

Action-Not Available
Vendor-Siemens AG
Product-Mendix Encryptionmendix_encryption
CWE ID-CWE-547
Use of Hard-coded, Security-relevant Constants
CVE-2024-39873
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.45% / 36.38%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-27 Aug, 2025 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2024-39874
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.41% / 33.48%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-27 Aug, 2025 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2024-35212
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-0.34% / 27.05%
||
7 Day CHG~0.00%
Published-11 Jun, 2024 | 11:15
Updated-11 Feb, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected application lacks input validation due to which an attacker can gain access to the Database entries.

Action-Not Available
Vendor-Siemens AG
Product-sinec_traffic_analyzerSINEC Traffic Analyzersinec_traffic_analyzer
CWE ID-CWE-20
Improper Input Validation
CVE-2024-38879
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.77% / 51.78%
||
7 Day CHG~0.00%
Published-02 Aug, 2024 | 10:36
Updated-03 Nov, 2025 | 22:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application.

Action-Not Available
Vendor-Siemens AG
Product-omnivise_t3000_application_serverOmnivise T3000 R8.2 SP4Omnivise T3000 R8.2 SP3Omnivise T3000 Application Server R9.2omnivise_t3000_application_serveromnivise_t3000
CWE ID-CWE-20
Improper Input Validation
CVE-2024-37370
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.75% / 51.13%
||
7 Day CHG~0.00%
Published-28 Jun, 2024 | 00:00
Updated-14 Jul, 2026 | 12:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In MIT Kerberos 5 (aka krb5) before 1.21.3, an attacker can modify the plaintext Extra Count field of a confidential GSS krb5 wrap token, causing the unwrapped token to appear truncated to the application.

Action-Not Available
Vendor-n/aSiemens AGMIT (Massachusetts Institute of Technology)
Product-kerberos_5n/aSIMATIC S7-1500 CPU 1518F-4 PN/DP MFPSIMATIC S7-1500 CPU 1518-4 PN/DP MFPSIPLUS S7-1500 CPU 1518-4 PN/DP MFP
CWE ID-CWE-345
Insufficient Verification of Data Authenticity
CVE-2022-2097
Matching Score-8
Assigner-OpenSSL Software Foundation
ShareView Details
Matching Score-8
Assigner-OpenSSL Software Foundation
CVSS Score-5.3||MEDIUM
EPSS-4.42% / 90.36%
||
7 Day CHG~0.00%
Published-05 Jul, 2022 | 10:30
Updated-17 Sep, 2024 | 01:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
AES OCB fails to encrypt some bytes

AES OCB mode for 32-bit x86 platforms using the AES-NI assembly optimised implementation will not encrypt the entirety of the data under some circumstances. This could reveal sixteen bytes of data that was preexisting in the memory that wasn't written. In the special case of "in place" encryption, sixteen bytes of the plaintext would be revealed. Since OpenSSL does not support OCB based cipher suites for TLS and DTLS, they are both unaffected. Fixed in OpenSSL 3.0.5 (Affected 3.0.0-3.0.4). Fixed in OpenSSL 1.1.1q (Affected 1.1.1-1.1.1p).

Action-Not Available
Vendor-Debian GNU/LinuxSiemens AGOpenSSLNetApp, Inc.Fedora Project
Product-sinec_insdebian_linuxopensslh500sh410s_firmwarefedorah300s_firmwareactive_iq_unified_managerh500s_firmwareclustered_data_ontap_antivirus_connectorh700s_firmwareh410sh410c_firmwareh410ch700sOpenSSLontap_antivirus_connectorsinec_inssmi-s_providerdebian_linuxopensslontap_select_deploy_administration_utilityoncommand_insightfedorahci_baseboard_management_controlleractive_iq_unified_manager_for_vmware_vspherebrocade_fabric_operating_system_firmwaresnapcenter
CWE ID-CWE-327
Use of a Broken or Risky Cryptographic Algorithm
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 10
  • 11
  • Next
Details not found